Search NASA⌕ Search

SEARCH · Search NASA

Results for “oxygen activation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Mutagenicity of arsenic in mammalian cells: role of reactive oxygen species

Arsenite, the trivalent form of arsenic present in the environment, is a known human carcinogen that lacked mutagenic activity in bacterial and standard mammalian cell mutation assays. We show herein that when evaluated in an assay (AL cell assay), in which both intragenic and multilocus mutations are detectable, that arsenite is in fact a strong dose-dependent mutagen and that it induces mostly large deletion mutations. Cotreatment of cells with the oxygen radical scavenger dimethyl sulfoxide significantly reduces the mutagenicity of arsenite. Thus, the carcinogenicity of arsenite can be explained at least in part by it being a mutagen that depends on reactive oxygen species for its activity.

Non-NASA Center↗

Accretion and primary differentiation of Mars

In collecting samples from Mars to address questions such as whether Mars accreted homogeneously or heterogeneously, how Mars segregated into a metallic core and silicate mantle, and whether Mars outgassed catastrophically coincident with accretion or more serenely on a longer timescale, we must be guided by our experience in addressing these questions for the Earth, Moon, and igneous meteorite parent bodies. A key measurement to be made on any sample returned from Mars is its oxygen isotopic composition. A single measurement will suffice to bind the SNC meteorites to Mars or demonstrate that they cannot be samples of that planet. A positive identification of Mars as the SNC parent planet will permit all that has been learned from the SNC meteorites to be applied to Mars with confidence. A negative result will perhaps be more exciting in forcing us to look for another object that has been geologically active in the recent past. If the oxygen isotopic composition of Earth and Mars are established to be distinct, accretion theory must provide for different compositions for two planets now separated by only 0.5 AU.

Drake, Michael J.↗

Oxygen desaturations triggered by partial seizures: implications for cardiopulmonary instability in epilepsy

PURPOSE: The occurrence of hypoxemia in adults with partial seizures has not been systematically explored. Our aim was to study in detail the temporal dynamics of this specific type of ictal-associated hypoxemia. METHODS: During long-term video/EEG monitoring (LTM), patients underwent monitoring of oxygen saturation using a digital Spo2 (pulse oximeter) transducer. Six patients (nine seizures) were identified with oxygen desaturations after the onset of partial seizure activity. RESULTS: Complex partial seizures originated from both left and right temporal lobes. Mean seizure duration (+/-SD) was 73 +/- 18 s. Mean Spo2 desaturation duration was 76 +/- 19 s. The onset of oxygen desaturation followed seizure onset with a mean delay of 43 +/- 16 s. Mean (+/-SD) Spo2 nadir was 83 +/- 5% (range, 77-91%), occurring an average of 35 +/- 12 s after the onset of the desaturation. One seizure was associated with prolonged and recurrent Spo2 desaturations. CONCLUSIONS: Partial seizures may be associated with prominent oxygen desaturations. The comparable duration of each seizure and its subsequent desaturation suggests a close mechanistic (possibly causal) relation. Spo2 monitoring provides an added means for seizure detection that may increase LTM yield. These observations also raise the possibility that ictal ventilatory dysfunction could play a role in certain cases of sudden unexpected death in epilepsy in adults with partial seizures.

NASA Program Biomedical Research and Countermeasur↗

Multiple Hollow Cathode Wear Testing

A hollow cathode-based plasma contactor has been baselined for use on the Space Station to reduce station charging. The plasma contactor provides a low impedance connection to space plasma via a plasma produced by an arc discharge. The hollow cathode of the plasma contactor is a refractory metal tube, through which xenon gas flows, which has a disk-shaped plate with a centered orifice at the downstream end of the tube. Within the cathode, arc attachment occurs primarily on a Type S low work function insert that is next to the orifice plate. This low work function insert is used to reduce cathode operating temperatures and energy requirements and, therefore, achieve increased efficiency and longevity. The operating characteristics and lifetime capabilities of this hollow cathode, however, are greatly reduced by oxygen bearing contaminants in the xenon gas. Furthermore, an optimized activation process, where the cathode is heated prior to ignition by an external heater to drive contaminants such as oxygen and moisture from the insert absorbed during exposure to ambient air, is necessary both for cathode longevity and a simplified power processor. In order to achieve the two year (approximately 17,500 hours) continuous operating lifetime requirement for the plasma contactor, a test program was initiated at NASA Lewis Research Center to demonstrate the extended lifetime capabilities of the hollow cathode. To date, xenon hollow cathodes have demonstrated extended lifetimes with one test having operated in excess of 8000 hours in an ongoing test utilizing contamination control protocols developed by Sarver-Verhey. The objectives of this study were to verify the transportability of the contamination control protocols developed by Sarver-Verhey and to evaluate cathode contamination control procedures, activation processes, and cathode-to-cathode dispersions in operating characteristics with time. These were accomplished by conducting a 2000 hour wear test of four hollow cathodes with different xenon gas purities and activation processes. The following will be presented: a description of the facility and test hardware, testing procedures and operating conditions, a discussion of test results, and conclusions.

Soulas, George C.↗

Spacecraft material flammability testing and configurations

Material and configuration testing for the Space Shuttle is mainly at 30 percent oxygen concentration at 70 kPa (10.2 psia). This is the worst case atmosphere during a mission and occurs 10 hours prior to extravehicular activity. The pressure is reduced from the nominal 101 kPa (14.7 paia) and the oxygen concentration is increased to 30 percent for medical reasons to prevent the bends during the extravehicular activity. NASA has tested many materials at 23.8, 25.9 and 30 percent oxygen levels for the Shuttle program. Data is given to show how flammability of material is affected by percentage of oxygen for those materials that would be considered for spacecraft applications.

Ledoux, Paul W.↗

Studies of the kinetics and mechanisms of perfluoroether reactions on iron and oxidized iron surfaces

Polymeric perfluoroalkylethers are being considered for use as lubricants in high temperature applications, but have been observed to catalytically decompose in the presence of metals. X-ray photoelectron spectroscopy (XPS) and temperature programmed desorption (TPD) were used to explore the decomposition of three model fluorinated ethers on clean polycrystalline iron surfaces and iron surfaces chemically modified with oxygen. Low temperature adsorption of the model fluorinated ethers on the clean, oxygen modified and oxidized iron surfaces was molecular. Thermally activated defluorination of the three model compounds was observed on the clean iron surface at remarkably low temperatures, 155 K and below, with formation of iron fluoride. Preferential C-F bond scission occurred at the terminal fluoromethoxy, CF3O, of perfluoro-1-methoxy-2-ethoxy ethane and perfluoro-1-methoxy-2-ethoxy propane and at CF3/CF2O of perfluoro-1,3-diethoxy propane. The reactivity of the clean iron toward perfluoroalkylether decomposition when compared to other metals is due to the strength of the iron fluoride bond and the strong electron donating ability of the metallic iron. Chemisorption of an oxygen overlayer lowered the reactivity of the iron surface to the adsorption and decomposition of the three model fluorinated ethers by blocking active sites on the metal surface. Incomplete coverage of the iron surface with chemisorbed oxygen results in a reaction which resembles the defluorination reaction observed on the clean iron surface. Perfluoro-1-methoxy-2-ethoxy ethane reacts on the oxidized iron surface at 138 K, through a Lewis acid assisted cleavage of the carbon oxygen bond, with preferential attack at the terminal fluoromethoxy, CF3O. The oxidized iron surface did not passivate, but became more reactive with time. Perfluoro-1-methoxy-2-ethoxy propane and perfluoro-1,3-diethoxy propane desorbed prior to the observation of decomposition on the oxidized iron surface.

Napier, Mary E.↗

A survey of X-ray line emission from the supernova remnant Puppis A

Initial results from the first high-resolution study of the X-ray spectrum of a supernova remnant are reported. The spectrum of Puppis A between 500 and 1100 eV has been surveyed with the Focal Plane Crystal Spectrometer on the Einstein Observatory and the flux in eight lines and three line blends from various transitions of highly ionized nitrogen, oxygen, neon, and iron has been measured. The spectrum resembles that of active regions in the solar corona, but the neon lines seem enhanced relative to the oxygen lines, and both are enhanced relative to iron. The observed line strengths serve as diagnostics of the physical conditions in the emitting material. Without a priori assumptions, the ionization temperatures of O (2.2 million K) and Ne (4 million K) and the dominant ionization stage of Fe (Fe XVII) are deduced. Isothermal equilibrium plasmas or homogeneous nonequilibrium plasmas as descriptions of the source are ruled out. It is concluded that Puppis A must contain plasma over a temperature range 2-million to 5-million K with an intervening absorption column of 4 x 10 to the 21st/sq cm.

Winkler, P. F.↗

Biochemical, endocrine, and hematological factors in human oxygen tolerance extension: Predictive studies 6

The Predictive Studies VI (Biochemical, endocrine, and hematological factors in human oxygen tolerance extension) Program consisted of two related areas of research activity, integrated in design and performance, that were each based on an ongoing analysis of human organ oxygen tolerance data obtained for the continuous oxygen exposures of the prior Predictive Studies V Program. The two research areas effectively blended broad investigation of systematically varied intermittent exposure patterns in animals with very selective evaluation of specific exposure patterns in man.

Lambertsen, C. J.↗

Cascade Storage and Delivery System for a Multi Mission Space Exploration Vehicle (MMSEV)

NASA is developing a Multi Mission Space Exploration Vehicle (MMSEV) for missions beyond Low Earth Orbit (LEO). The MMSEV is a pressurized vehicle used to extend the human exploration envelope for Lunar, Near Earth Object (NEO), and Deep Space missions. The Johnson Space Center is developing the Environmental Control and Life Support System (ECLSS) for the MMSEV. The MMSEV s intended use is to support longer sortie lengths with multiple Extra Vehicular Activities (EVAs) on a higher magnitude than any previous vehicle. This paper presents an analysis of a high pressure oxygen cascade storage and delivery system that will accommodate the crew during long duration Intra Vehicular Activity (IVA) and capable of multiple high pressure oxygen fills to the Portable Life Support System (PLSS) worn by the crew during EVAs. A cascade is a high pressure gas cylinder system used for the refilling of smaller compressed gas cylinders. Each of the large cylinders are filled by a compressor, but the cascade system allows small cylinders to be filled without the need of a compressor. In addition, the cascade system is useful as a "reservoir" to accommodate low pressure needs. A regression model was developed to provide the mechanism to size the cascade systems subject to constraints such as number of crew, extravehicular activity duration and frequency, and ullage gas requirements under contingency scenarios. The sizing routine employed a numerical integration scheme to determine gas compressibility changes during depressurization and compressibility effects were captured using the Soave-Redlich-Kwong (SRK) equation of state. A multi-dimensional nonlinear optimization routine was used to find the minimum cascade tank system mass that meets the mission requirements. The sizing algorithms developed in this analysis provide a powerful framework to assess cascade filling, compressor, and hybrid systems to design long duration vehicle ECLSS architecture. 1

Yagoda, Evan↗

International Space Station (ISS) Oxygen High Pressure Storage Management

High pressure oxygen onboard the ISS provides support for Extra Vehicular Activities (EVA) and contingency metabolic support for the crew. This high pressure 02 is brought to the ISS by the Space Shuttle and is transferred using the Oxygen Recharge Compressor Assembly (ORCA). There are several drivers that must be considered in managing the available high pressure 02 on the ISS. The amount of O2 the Shuttle can fly up is driven by manifest mass limitations, launch slips, and on orbit Shuttle power requirements. The amount of 02 that is used from the ISS high pressure gas tanks (HPGT) is driven by the number of Shuttle docked and undocked EVAs, the type of EVA prebreath protocol that is used and contingency use of O2 for metabolic support. Also, the use of the ORCA must be managed to optimize its life on orbit and assure that it will be available to transfer the planned amount of O2 from the Shuttle. Management of this resource has required long range planning and coordination between Shuttle manifest on orbit plans. To further optimize the situation hardware options have been pursued.

Lewis, John R.↗

Dual-cycle ergometry as an exercise modality during prebreathe with 100 percent oxygen

In an effort to reduce prebreathe time requirements prior to extravehicular activities and high-altitude flights, a combined arm and leg exercise task proposes to enhance denitrogenation by incorporation of both upper and lower body musculature at a moderately high work intensity during prebreathe with 100% oxygen. Preliminary findings indicated peak oxygen consumption (VO2peak) levels attained on the dual-cycle ergometer do not differ significantly from those levels attained on the treadmill. Eight male subjects were exercised to VO2peak using leg-only cycle ergometry and dual-cycle ergometry on separate days. Preliminary data during dual-cycle ergometry showed arm work equaling 30% of the leg workrate at each stage of the incremental test resulted in arm fatigue in several subjects and a reduced VO2peak compared to dual-cycle ergometry with arm work at 20%. Thus, the 20% workrate was used during the dual-cycle VO2peak trial. On a third experimental day, subjects performed a 10 minute exercise test at a workrate required to elicit 75% of VO2peak for each subject on the dual-cycle ergometer. Blood lactate response to the exercise was monitored as an objective measure of fatigue. Peak VO2 levels attained on the leg-only and the dual-cycle ergometry tasks were not significantly different. Blood lactate levels were significantly elevated following the dual-cycle ergometry at 75% VO2peak. However, lactate levels show the expected rate of decline during recovery and, as demonstrated in the literature, should return to baseline levels within 30 minutes following exercise cessation. Thus, dual-cycle ergometry at 75% VO2peak appears to be a valid exercise for use during prebreathe and should not contribute to fatigue during subsequent EVA's.

Heaps, Cristine L.↗

The Venus atmospheric response to solar cycle variations

Atmospheric drag measurements from the orbital decay of the Pioneer Venus Orbiter and Magellan spacecraft have recently been obtained of the Venus dayside and nightside atmosphere between 130 and 210 km during a period of low solar activity. These new measurements, combined with the earlier Pioneer Venus drag measurements (1978-80) obtained near the maximum of the 11-year solar cycle, have allowed the detection of the detailed response of temperature, atomic oxygen and carbon dioxide to solar variations. We have found a weak but detectable temperature response on the dayside which is in accord with the response predicted by Keating and Bougher when they assumed very strong CO2 radiative cooling resulting from atomic oxygen exciting CO2 into 15 micron emission. This same radiative process may cause strong cooling in the Earth's upper atmosphere with the doubling of CO2 in the future. With decreasing solar activity, the O/CO2 ratio in the lower thermosphere is found to decrease, apparently due to decreased photodissociation of CO2 and lower temperatures. The percent decrease in atomic oxygen with decreasing solar activity on the dayside is found to be approximately the same as the percent decreases of atomic oxygen transported to the nightside. A very weak response of nightside temperatures to solar activity variations has also been detected.

Keating, Gerald M.↗

The Venus Atmospheric Response to Solar Cycle Variations

Atmospheric drag measurements from the orbital decay of the Pioneer Venus Orbiter and Magellan spacecraft have recently been obtained of the Venus dayside and nightside atmosphere between 130 and 210 km during a period of low solar activity. These new measurements, combined with the earlier Pioneer Venus drag measurements (1978-80) obtained near the maximum of the 11-year solar cycle, have allowed the detection of the detailed response of temperature, atomic oxygen and carbon dioxide to solar variations. We have found a weak but detectable temperature response on the dayside which is in accord with the response predicted by Keating and Bougher when they assumed very strong CO2 radiative cooling resulting from atomic oxygen exciting CO2 into 15 micron emission. This same radiative process may cause strong cooling in the Earth's upper atmosphere with the doubling of CO2 in the future. With decreasing solar activity, the O/CO2 ratio in the lower thermosphere is found to decrease, apparently due to decreased photodissociation of CO2 and lower temperatures. The percent decrease in atomic oxygen with decreasing solar activity on the dayside is found to be approximately the same as the percent decreases of atomic oxygen transported to the nightside. A very weak response of nightside temperatures to solar activity variations has also been detected.

Keating, Gerald M.↗

Relative rates of nitric oxide and nitrous oxide production by nitrifiers, denitrifiers, and nitrate respirers

An account is given of the atmospheric chemical and photochemical effects of biogenic nitric and nitrous oxide emissions. The magnitude of the biogenic emission of NO is noted to remain uncertain. Possible soil sources of NO and N2O encompass nitrification by autotropic and heterotropic nitrifiers, denitrification by nitrifiers and denitrifiers, nitrate respiration by fermenters, and chemodenitrification. Oxygen availability is the primary determinant of these organisms' relative rates of activity. The characteristics of this major influence are presently investigated in light of the effect of oxygen partial pressure on NO and N2O production by a wide variety of common soil-nitrifying, denitrifying, and nitrate-respiring bacteria under laboratory conditions. The results obtained indicate that aerobic soils are primary sources only when there is sufficient moisture to furnish anaerobic microsites for denitrification.

Anderson, I. C.↗

Oxygen Plasma Modification of Poss-Coated Kapton(Registered TradeMark) HN Films

The surface energy of a material depends on both surface composition and topographic features. In an effort to modify the surface topography of Kapton(Registered TradeMark) HN film, organic solutions of a polyhedral oligomeric silsesquioxane, octakis(dimethylsilyloxy)silsesquioxane (POSS), were spray-coated onto the Kapton(Registered TradeMark) HN surface. Prior to POSS application, the Kapton(Registered TradeMark) HN film was activated by exposure to radio frequency (RF)-generated oxygen plasma. After POSS deposition and solvent evaporation, the films were exposed to various durations of RF-generated oxygen plasma to create a topographically rich surface. The modified films were characterized using optical microscopy, attenuated total reflection infrared (ATR-IR) spectroscopy, and high-resolution scanning electron microscopy (HRSEM). The physical properties of the modified films will be presented.

Wohl, C. J.↗

The use of rice hulls for sustainable control of NOx emissions in deep space missions

The use of the activated carbon produced from rice hulls to control NOx emissions for future deep space missions has been demonstrated. The optimal carbonization temperature range was found to be between 600 and 750 degrees C. A burnoff of 61.8% was found at 700 degrees C in pyrolysis and 750 degrees C in activation. The BET surface area of the activated carbon from rice hulls was determined to be 172 m2/g when prepared at 700 degrees C. The presence of oxygen in flue gas is essential for effective adsorption of NO by activated carbon. On the contrary, water vapor inhibits the adsorption efficiency of NO. Consequently, water vapor in flue gas should be removed by drying agents before adsorption to ensure high NO adsorption efficiency. All of the NO in the flue gas was removed for more than 1.5 h when 10% oxygen was present and the ratio of the carbon weight to the flue gas flow rate (W/F) was 15.4 g min/L. Reduction of the adsorbed NO to form N2 could be effectively accomplished under anaerobic conditions at 550 degrees C. The adsorption capacity of NO on the activated carbon was found to be 5.02 mg of NO/g of carbon. The loss of carbon mass was determined to be about 0.16% of the activated carbon per cycle of regeneration if the regeneration occurred when the NO in the flue gas after the carbon bed reached 4.8 ppm, the space maximum allowable concentration. The reduction of the adsorbed NO also regenerated the activated carbon, and the regenerated activated carbon exhibited an improved NO adsorption efficiency.

NASA Program Advanced Human Support Technology↗

Space Suit Portable Life Support System Oxygen Regulator History, Development, & Testing Results

An oxygen regulator has been in development for the space suit Exploration Extravehicular Mobility Unit (xEMU) Portable Life Support System (PLSS). The regulator provides the necessary oxygen pressure for the crew member during pre-breathe, extra-vehicular activity (EVA), post EVA airlock operations, and decompression sickness treatment. The last time a spacesuit oxygen regulator was designed was for the Space Shuttle Program EMU. The regulator & EMU were then used on the International Space Station (ISS) with no significant changes to the regulator throughout its life. This xEMU PLSS spacesuit oxygen regulator implements many elements of the previous EMU Secondary Oxygen Pack (SOP) design while integrating numerous new improvements and changes. There are changes both to the high-level regulator architecture approach in the suit itself, in addition to modernizations with electrical motor control & sensing. For architecture, there are two oxygen regulators for each space suit, a primary and secondary that are nearly identical to each other and have the same maximum design pressure of 3750 Pounds per Square Inch Absolute (PSIA). The primary regulator provides nominal pressure during EVA, while the secondary provides a backup pressure only in case of primary regulator failure or if an emergency purge of the suit oxygen is required. The design was based originally off of the secondary oxygen regulator on the EMU which utilizes a two-stage regulator to improve safety and controllability. The xEMU PLSS Oxygen Regulator development started with a modification to add a linear actuator to the design to control the downstream pressure electronically instead of a manual control with a wire linkage system used with the EMU. The design was iterated to include a Monel body for oxygen fire safety, and sensors for pressure verification at each stage. Then the regulator design was packaged to fit into the xEMU PLSS envelope. Development included extensive testing which brought to light some issues with the design which were addressed at each stage of development. This paper will review the design history, development, testing results, and lessons learned designing the xEMU PLSS Oxygen Regulator.

Ryan Ogilvie↗

Biosensors for EVA: Muscle Oxygen and pH During Walking, Running and Simulated Reduced Gravity

During lunar excursions in the EVA suit, real-time measurement of metabolic rate is required to manage consumables and guide activities to ensure safe return to the base. Metabolic rate, or oxygen consumption (VO2), is normally measured from pulmonary parameters but cannot be determined with standard techniques in the oxygen-rich environment of a spacesuit. Our group developed novel near infrared spectroscopic (NIRS) methods to calculate muscle oxygen saturation (SmO2), hematocrit, and pH, and we recently demonstrated that we can use our NIRS sensor to measure VO2 on the leg during cycling. Our NSBRI-funded project is looking to extend this methodology to examine activities which more appropriately represent EVA activities, such as walking and running and to better understand factors that determine the metabolic cost of exercise in both normal and lunar gravity. Our 4 year project specifically addresses risk: ExMC 4.18: Lack of adequate biomedical monitoring capability for Constellation EVA Suits and EPSP risk: Risk of compromised EVA performance and crew health due to inadequate EVA suit systems.

Lee, S. M. C.↗