Search NASA⌕ Search

SEARCH · Search NASA

Results for “phantom”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Enhanced Monte Carlo Simulation of the Voxel Phantom Lattice Submersed in a Contaminated Air Environment

External dose coefficient calculations reported for submersions in semi-infinite clouds, as in the Environmental Protection Agency: Federal Guidance Report 12, assume a person standing on the ground submerged in a radioactive cloud. In the scope of the work presented here, Oak Ridge National Laboratory's Center for Radiation Protection Knowledge has computed dose coefficients for monoenergetic photons, electrons, and positrons for worker exposures in three rooms of finite sizes representing an office, laboratory, and warehouse. In the process of simulating these exposures, International Commission on Radiological Protection (ICRP) Publication 110 reference adult male and female voxel phantom lattices were placed in the rooms filled with contaminated air. It was apparent that additional simulations were need to treat the non-tissue voxels surrounding the phantoms as containing the contaminated air. Dose coefficients for three room sizes representing an office, laboratory, and warehouse were computed. The coefficients for electrons exhibit little dependence on room size for most energies. However, for organs within the range of electron transport, the dose from source activity within the non-tissue voxels of the lattice surrounding the phantom becomes increasingly important. The photon dose coefficients vary based on room size because of longer mean free paths. It is important to include the air surrounding the voxel phantom within the voxel lattice in the calculations, when simulating a voxel phantom submersed in air for source particle energies below 200-300 keV, otherwise, the organ dose coefficient would be underestimated. Organ and effective dose coefficients for each gender, energy, and room size will be tabulated on the Oak Ridge National Laboratory - Center for Radiation Protection Knowledge website: http://ornl.gov/crpk.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Livermore Phantom History and Supplementation

In vivo monitoring facilities determine the absence or presence of internally entrained radionuclides. To be of greatest utility, the detection systems must detect and quantify the nuclides of interest at levels of interest. Phantoms have been developed to improve measurements at in vivo monitoring facilities. Since the 1970s, the Lawrence Livermore National Laboratory (LLNL, or simply "Livermore") phantom continues to be a well-used tool at lung monitoring facilities, especially for the detection of low-energy emissions from transuranics. The history of its development from need, through design development and current availability, is summarized. The authors have taken the LLNL phantom one step further by scanning the phantom surface and announce the availability of the scan files on the internet.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparing Effective Doses During Image-Guided Core Needle Biopsies with Computed Tomography Versus C-Arm Cone Beam CT Using Adult and Pediatric Phantoms

PurposeTo compare the effective doses of needle biopsies based on dose measurements and simulations using adult and pediatric phantoms, between cone beam c-arm CT (CBCT) and CT.MethodEffective doses were calculated and compared based on measurements and Monte Carlo simulations of CT- and CBCT-guided biopsy procedures of the lungs, liver, and kidney using pediatric and adult phantoms.ResultsThe effective doses for pediatric and adult phantoms, using our standard protocols for upper, middle and lower lungs, liver, and kidney biopsies, were significantly lower under CBCT guidance than CT. The average effective dose for a 5-year old for these five biopsies was 0.36 ± 0.05 mSv with the standard CBCT exposure protocols and 2.13 ± 0.26 mSv with CT. The adult average effective dose for the five biopsies was 1.63 ± 0.22 mSv with the standard CBCT protocols and 8.22 ± 1.02 mSv using CT. The CT effective dose was higher than CBCT protocols for child and adult phantoms by 803 and 590 % for upper lung, 639 and 525 % for mid-lung, and 461 and 251 % for lower lung, respectively. Similarly, the effective dose was higher by 691 and 762 % for liver and 513 and 608 % for kidney biopsies.ConclusionsBased on measurements and simulations with pediatric and adult phantoms, radiation effective doses during image-guided needle biopsies of the lung, liver, and kidney are significantly lower with CBCT than with CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Particle Imaging Guided Real-Time Percutaneous Transluminal Angioplasty in a Phantom Model

PurposeTo investigate the potential of real-time magnetic particle imaging (MPI) to guide percutaneous transluminal angioplasty (PTA) of vascular stenoses in a phantom model.Materials and MethodsExperiments were conducted on a custom-built MPI scanner. Vascular stenosis phantoms consisted of polyvinyl chloride tubes (inner diameter 8 mm) prepared with a centrally aligned cable tie to form ~ 50% stenoses. MPI angiography for visualization of stenoses was performed using the superparamagnetic iron oxide nanoparticle-based contrast agent Ferucarbotran (10 mmol (Fe)/l). Balloon catheters and guidewires for PTA were visualized using custom-made lacquer markers based on Ferucarbotran. Stenosis dilation (n = 3) was performed by manually inflating the PTA balloon with diluted Ferucarbotran. An online reconstruction framework was implemented for real-time imaging with very short latency time.ResultsVisualization of stenosis phantoms and guidance of interventional instruments in real-time (4 frames/s, ~ 100 ms latency time) was possible using an online reconstruction algorithm. Labeling of guidewires and balloon catheters allowed for precise visualization of instrument positions.ConclusionReal-time MPI-guided PTA in a phantom model is feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of neutron cross-section resonances on organ/tissue equivalent and effective dose coefficients for the ICRP voxel phantoms

The materials which compose the ICRP Voxel phantoms used in the computation of conversion coefficients involve neutron interaction cross-sections that have resonances at specific energies. Depending on the energy bin structure used in the computations, these cross-section resonances may occur at energies that fall between energies at which dose coefficients are computed, thus their effects may not be completely accounted for in the reported coefficients. Here In this study, a highly refined energy grid that closely follows the resonance structure in the phantom material cross-sections was identified and used to calculate dose coefficients. Both the equivalent organ/tissue doses for male and female voxel phantoms were computed as well as their summation to obtain the effective dose coefficients. The used refined energy grid tracks very closely the cross-sections in the vicinity of the resonances. The resulting refined energy grid coefficients are compared to coefficients for the coarser energy grid used in ICRP Publication 116. Additionally, reference spectra have been folded with both the fine and coarse sets of conversion coefficients. The resulting total effective doses for these reference spectra are used to assess the adequacy of the dose coefficients calculated on the original ICRP 116 energy grid. The dose coefficients were similarly computed for the local skin dose on the trunk of the body using the ICRU Report 95 phantom. The overall impact of the resonances on the organ/tissue equivalent dose, the effective dose, and the local skin dose are presented and discussed. In general, it was found that resonances can impact neutron dose coefficients, but in most cases the wide range of neutron energies encountered minimized this effect. The impact of resonances was further limited when computing effective dose due to organ/tissue summing and sex-averaging. For the neutron fields studied here, the impact was below 5%.

36 MATERIALS SCIENCE↗

Characterization of responses of 2d array seven29 detector and its combined use with octavius phantom for the patient-specific quality assurance in rapidarc treatment delivery

A commercial 2D array seven29 detector has been characterized and its performance has been evaluated. 2D array ionization chamber equipped with 729 ionization chambers uniformly arranged in a 27 Multiplication-Sign 27 matrix with an active area of 27 Multiplication-Sign 27 cm{sup 2} was used for the study. An octagon-shaped phantom (Octavius Phantom) with a central cavity is used to insert the 2D ion chamber array. All measurements were done with a linear accelerator. The detector dose linearity, reproducibility, output factors, dose rate, source to surface distance (SSD), and directional dependency has been studied. The performance of the 2D array, when measuring clinical dose maps, was also investigated. For pretreatment quality assurance, 10 different RapidArc plans conforming to the clinical standards were selected. The 2D array demonstrates an excellent short-term output reproducibility. The long-term reproducibility was found to be within {+-}1% over a period of 5 months. Output factor measurements for the central chamber of the array showed no considerable deviation from ion chamber measurements. We found that the 2D array exhibits directional dependency for static fields. Measurement of beam profiles and wedge-modulated fields with the 2D array matched very well with the ion chamber measurements in the water phantom. The study shows that 2D array seven29 is a reliable and accurate dosimeter and a useful tool for quality assurance. The combination of the 2D array with the Octavius phantom proved to be a fast and reliable method for pretreatment verification of rotational treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of setup error using different reference images: a phantom and lung cancer patients study

The purpose of this study was to compare setup errors obtained with kilovoltage cone-beam computed tomography (CBCT) and 2 different kinds of reference images, free-breathing 3D localization CT images (FB-CT) and the average images of 4-D localization CT images (AVG-CT) for phantom and lung cancer patients. This study also explored the correlation between the difference of translational setup errors and the gross tumor volume (GTV) motion. A respiratory phantom and 14 patients were enrolled in this study. For phantom and each patient, 3D helical CT and 4D CT images were acquired, and AVG-CT images were generated from the 4D CT. The setup errors were determined based on the image registration between the CBCT and the 2 different reference images, respectively. The data for both translational and rotational setup errors were analyzed and compared. The GTV centroid movement as well as its correlation with the translational setup error differences was also evaluated. In the phantom study, the AVG-CT method was more accurate than the FB-CT method. For patients, the translational setup errors based on FB-CT were significantly larger than those from AVG-CT in the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) directions (p < 0.05). Translational setup errors differed by >1 mm in 32.6% and >2 mm in 12.9% of CBCT scans. The rotational setup errors from FB-CT were significantly different from those from AVG-CT in the LR and AP directions (p < 0.05). The correlation coefficient of the translational setup error differences and the GTV centroid movement in the LR, SI, and AP directions was 0.515 (p = 0.060), 0.902 (p < 0.001), and 0.510 (p = 0.062), respectively. For lung cancer patients, respiration may affect the on-line target position location. AVG-CT provides different reference information than FB-CT. The difference in SI direction caused by the 2 methods increases with the GTV movement. Therefore, AVG-CT should be the prefered choice of reference images.

61 RADIATION PROTECTION AND DOSIMETRY↗

A fast and reliable method for daily quality assurance in spot scanning proton therapy with a compact and inexpensive phantom

In a radiotherapy center, daily quality assurance (QA) measurements are performed to ensure that the equipment can be safely used for patient treatment on that day. In a pencil beam scanning (PBS) proton therapy center, spot positioning, spot size, range, and dose output are usually verified every day before treatments. We designed, built, and tested a new, reliable, sensitive, and inexpensive phantom, coupled with an array of ionization chambers, for daily QA that reduces the execution times while preserving the reliability of the test. The phantom is provided with 2 pairs of wedges to sample the Bragg peak at different depths to have a transposition on the transverse plane of the depth dose. Three “boxes” are used to check spot positioning and delivered dose. The box thickness helps spread the single spot and to fit a Gaussian profile on a low resolution detector. We tested whether our new QA solution could detect errors larger than our action levels: 1 mm in spot positioning, 2 mm in range, and 10% in spot size. Execution time was also investigated. Our method is able to correctly detect 98% of spots that are actually in tolerance for spot positioning and 99% of spots out of 1 mm tolerance. All range variations greater than the threshold (2 mm) were correctly detected. The analysis performed over 1 month showed a very good repeatability of spot characteristics. The time taken to perform the daily quality assurance is 20 minutes, a half of the execution time of the former multidevice procedure. This “in-house build” phantom substitutes 2 very expensive detectors (a multilayer ionization chamber [MLIC] and a strip chamber, reducing by 5 times the cost of the equipment. We designed, built, and validated a phantom that allows for accurate, sensitive, fast, and inexpensive daily QA procedures in proton therapy with PBS.

61 RADIATION PROTECTION AND DOSIMETRY↗

On the Applicability of the Thermal Dose Cumulative Equivalent Minutes Metric to the Denaturation of Bovine Serum Albumin in a Polyacrylamide Tissue Phantom

Thermal dose has been proposed for various hyperthermic cancer treatment modalities as a measure of heat-induced tissue damage. However, the applicability of current thermal dose metrics to tissue is not well understood, particularly at the temperatures and rates of heating relevant to ablative cancer therapy using High-Intensity Focussed Ultrasound (HIFU). In this work, we assess whether the most widely employed thermal dose metric, Cumulative Equivalent Minutes (CEM), can adequately quantify heat-induced denaturation in a tissue-mimicking material (phantom) consisting of Bovine Serum Albumin (BSA) proteins embedded in a polyacrylamide matrix. The phantom is exposed to various temperature profiles and imaged under controlled lighting conditions against a black background as it denatures and becomes progressively more opaque. Under the assumption that the mean backscattered luminous intensity provides a good measure of the extent of BSA denaturation, we establish a relationship between the amount of thermal damage caused to the phantom, exposure time, and temperature. We demonstrate that, for monotonically increasing and bounded temperature profiles, the maximal degree to which the phantom can denature is dependent on the peak temperature it reaches, irrespective of exposure duration. We also show that when the CEM is computed using the commonly employed piecewise-constant approximation of the parameter R, the CEM values corresponding to the same degree of damage delivered using different temperature profiles do not agree well with each other in general.

60 APPLIED LIFE SCIENCES↗

Multiparameter double hole contrast detail phantom: Ability to detect image displacement due to off position anode stem

Contrast Detail phantom is a quality control tool to analyze the performance of imaging devices. Currently, its function is solely to evaluate the contrast detail characteristic of imaging system. It consists of drilled hole which gives effect to the penetration of x-ray beam divergence to pass through the base of each hole. This effect will lead to false appearance of image from its original location but it does not being visualized in the radiograph. In this study, a new design of Contrast Detail phantom’s hole which consists of double hole construction has been developed. It can detect the image displacement which is due to off position of anode stem from its original location. The double hole differs from previous milled hole, whereby it consists of combination of different hole diameters. Small hole diameter (3 mm) is positioned on top of larger hole diameter (10 mm). The thickness of double hole acrylic blocks is 13 mm. Result revealed that Multiparameter Double Hole Contrast Detail phantom can visualize the shifted flaw image quality produced by x-ray machine due to improper position of the anode stem which is attached to rotor and stator. The effective focal spot of x-ray beam also has been shifted from the center of collimator as a result of off-position anode stem. As a conclusion, the new design of double hole Contrast Detail phantom able to measure those parameters in a well manner.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Liquid optical phantoms mimicking spectral characteristics of laboratory mouse biotissues

Optical phantoms mimicking optical properties of real biotissues in the visible and IR spectral regions are developed based on measurements of the spectral characteristics of ex vivo samples of laboratory mouse biotissues. The phantoms are composed of aqueous solutions of Lipofundin, Indian ink and red ink with different spectral characteristics. The deviations of the measured absorption and scattering coefficients of phantoms in the wavelength range 480 – 580 nm from the corresponding values for real biotissues do not exceed 25% and 2%, respectively. For phantoms in the wavelength region 580 – 880 nm, the deviations of the absorption coefficient do not exceed 40% and the deviations of the scattering coefficient do not exceed 25%. These values, in general, fall within the range of variations for different individual mice of one strain. (laser biophotonics)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamics of interacting phantom scalar field dark energy in loop quantum cosmology

We study the dynamics of a phantom scalar field dark energy interacting with dark matter in loop quantum cosmology. Two kinds of coupling of the form {alpha}{rho}{sub m}{phi} (case I) and 3{beta}H({rho}{sub {phi}}+{rho}{sub m}) (case II) between the phantom energy and dark matter are examined with the potential for the phantom field taken to be exponential. For both kinds of interactions, we find that the future singularity appearing in the standard Friedmann-Robertson-Walker cosmology can be avoided by loop quantum gravity effects. In case II, if the phantom field is initially rolling down the potential, the loop quantum effect has no influence on the cosmic late time evolution and the universe will accelerate forever with a constant energy ratio between the dark energy and dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phantom energy accretion onto black holes in a cyclic universe

Black holes pose a serious problem in cyclic or oscillating cosmology. It is speculated that, in the cyclic universe with phantom turnarounds, black holes will be torn apart by phantom energy prior to turnaround before they can create any problems. In this paper, using the mechanism of phantom accretion onto black holes, we find that black holes do not disappear before phantom turnaround. But the remanent black holes will not cause any problems due to Hawking evaporation.

79 ASTRONOMY AND ASTROPHYSICS↗

Use of a line-pair resolution phantom for comprehensive quality assurance of electronic portal imaging devices based on fundamental imaging metrics

Image guided radiation therapy solutions based on megavoltage computed tomography (MVCT) involve the extension of electronic portal imaging devices (EPIDs) from their traditional role of weekly localization imaging and planar dose mapping to volumetric imaging for 3D setup and dose verification. To sustain the potential advantages of MVCT, EPIDs are required to provide improved levels of portal image quality. Therefore, it is vital that the performance of EPIDs in clinical use is maintained at an optimal level through regular and rigorous quality assurance (QA). Traditionally, portal imaging QA has been carried out by imaging calibrated line-pair and contrast resolution phantoms and obtaining arbitrarily defined QA indices that are usually dependent on imaging conditions and merely indicate relative trends in imaging performance. They are not adequately sensitive to all aspects of image quality unlike fundamental imaging metrics such as the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) that are widely used to characterize detector performance in radiographic imaging and would be ideal for QA purposes. However, due to the difficulty of performing conventional MTF measurements, they have not been used for routine clinical QA. The authors present a simple and quick QA methodology based on obtaining the MTF, NPS, and DQE of a megavoltage imager by imaging standard open fields and a bar-pattern QA phantom containing 2 mm thick tungsten line-pair bar resolution targets. Our bar-pattern based MTF measurement features a novel zero-frequency normalization scheme that eliminates normalization errors typically associated with traditional bar-pattern measurements at megavoltage x-ray energies. The bar-pattern QA phantom and open-field images are used in conjunction with an automated image analysis algorithm that quickly computes the MTF, NPS, and DQE of an EPID system. Our approach combines the fundamental advantages of linear systems metrics such as robustness, sensitivity across the full spatial frequency range of interest, and normalization to imaging conditions (magnification, system gain settings, and exposure), with the simplicity, ease, and speed of traditional phantom imaging. The algorithm was analyzed for accuracy and sensitivity by comparing with a commercial portal imaging QA method (PIPSPRO, Standard Imaging, Middleton, WI) on both first-generation lens-coupled and modern a-Si flat-panel based clinical EPID systems. The bar-pattern based QA measurements were found to be far more sensitive to even small levels of degradation in spatial resolution and noise. The bar-pattern based QA methodology offers a comprehensive image quality assessment tool suitable for both commissioning and routine EPID QA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid Water as phantom material for dosimetry of electron backscatter using low-energy electron beams: A Monte Carlo evaluation

This study evaluated the dosimetry of electron backscatter when Solid Water is used to substitute water as phantom in electron radiotherapy. Monte Carlo simulation (EGSnrc-based code) was employed to predict electron energy spectra and depth doses for the 0.5 and 1 cm of Solid Water and water slabs above 3 mm of lead (Pb) layers using electron beams with energies of 4 and 6 MeV. For comparison, Monte Carlo simulations were repeated with Pb layers taken out from the phantoms using the same experimental configuration. Analyses on electron energy spectra for the 4 and 6 MeV electron beams showed that deviations of electron energy distributions between the Solid Water and water phantom were more significant in the high-energy range (i.e., close to the maximal electron energy) than the lower range corresponding to the electron backscatter. These deviations of electron energy spectra varied with depth and were mainly due to the electron fluence or beam attenuation. Dosimetry results from Monte Carlo simulations showed that the Solid Water phantom had lower depth dose compared to water with the same experimental setup. For the 4 MeV electron beams with 0.5 cm of Solid Water, depth doses were 1.8%-3.9% and 2.3%-4.4% lower than those in water, with and without the Pb layer underneath, respectively. Thicker Solid Water of 1 cm resulted in different decreases in depth doses of 1.8%-4.6% (with Pb) and 2.3%-4.4% (without Pb) compared to water. For higher nominal electron beam energy of 6 MeV with 0.5 cm of Solid Water, depth doses decreased 1.7%-2.9% (with Pb) and 1.6%-2.1% (without Pb) compared to water. These decreases in depth doses changed to 1.7%-3.7% (with Pb) and 1.7%-3% (without Pb) when the thickness of Solid Water was increased to 1 cm. The dosimetry data in this study are useful in determining the correction factor when using Solid Water to substitute water for the electron backscatter measurement in electron radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy

The objective of this work is to assess the suitability and performance of a new dosimeter system with a novel geometry for the quality assurance (QA) of volumetric modulated arc therapy (VMAT). The new dosimeter system consists of a hollow cylinder (15 and 25 cm inner and outer diameters) with 124 diodes embedded in the phantom's cylindrical wall forming four rings of detectors. For coplanar beams, the cylindrical geometry and the ring diode pattern offer the advantage of invariant perpendicular incidence on the beam central axis for any gantry angle and also have the benefit of increasing the detector density as both walls of the cylinder sample the beam. Other advantages include real-time readout and reduced weight with the hollow phantom shape. A calibration method taking into account the variation in radiation sensitivity of the diodes as a function of gantry angle was developed and implemented. In this work, the new dosimeter system was used in integrating mode to perform composite dose measurements along the cylindrical surface supporting the diodes. The reproducibility of the dosimeter response and the angular dependence of the diodes were assessed using simple 6 MV photon static beams. The performance of the new dosimeter system for VMAT QA was then evaluated using VMAT plans designed for a head and neck, an abdominal sarcoma, and a prostate patient. These plans were optimized with 90 control points (CPs) and additional versions of each plan were generated by increasing the number of CPs to 180 and 360 using linear interpolation. The relative dose measured with the dosimeter system for the VMAT plans was compared to the corresponding TPS dose map in terms of relative dose difference (%{Delta}D) and distance to agreement (DTA). The dosimeter system's sensitivity to gantry rotation offset and scaling errors as well as setup errors was also evaluated. For static beams, the dosimeter system offered good reproducibility and demonstrated small residual diode angular dependence after calibration. For VMAT deliveries, the agreement between measured and calculated doses was good with {>=}86.4% of the diodes satisfying 3% of %{Delta}D or 2 mm DTA for the 180 CP plans. The phantom offered sufficient sensitivity for the detection of small gantry rotation offset (3 deg.) and scaling errors (1 deg.) as well as phantom setup errors of 1 mm, although the results were plan dependent. With its novel geometry, the dosimeter system was also able to experimentally demonstrate the discretization effect of the number of CPs used in the TPS to simulate a continuous arc. These results demonstrate the suitability of the new dosimeter system for the patient-specific QA of VMAT plans and suggest that the dosimeter system can be an effective tool in the routine QA and commissioning of treatment machines capable of VMAT delivery and cone-beam CT image guidance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computerized method for evaluating diagnostic image quality of calcified plaque images in cardiac CT: Validation on a physical dynamic cardiac phantom

Purpose: In cardiac computed tomography (CT), important clinical indices, such as the coronary calcium score and the percentage of coronary artery stenosis, are often adversely affected by motion artifacts. As a result, the expert observer must decide whether or not to use these indices during image interpretation. Computerized methods potentially can be used to assist in these decisions. In a previous study, an artificial neural network (ANN) regression model provided assessability (image quality) indices of calcified plaque images from the software NCAT phantom that were highly agreeable with those provided by expert observers. The method predicted assessability indices based on computer-extracted features of the plaque. In the current study, the ANN-predicted assessability indices were used to identify calcified plaque images with diagnostic calcium scores (based on mass) from a physical dynamic cardiac phantom. The basic assumption was that better quality images were associated with more accurate calcium scores. Methods: A 64-channel CT scanner was used to obtain 500 calcified plaque images from a physical dynamic cardiac phantom at different heart rates, cardiac phases, and plaque locations. Two expert observers independently provided separate sets of assessability indices for each of these images. Separate sets of ANN-predicted assessability indices tailored to each observer were then generated within the framework of a bootstrap resampling scheme. For each resampling iteration, the absolute calcium score error between the calcium scores of the motion-contaminated plaque image and its corresponding stationary image served as the ground truth in terms of indicating images with diagnostic calcium scores. The performances of the ANN-predicted and observer-assigned indices in identifying images with diagnostic calcium scores were then evaluated using ROC analysis. Results: Assessability indices provided by the first observer and the corresponding ANN performed similarly (AUC{sub OBS1}=0.80 [0.73,0.86] vs AUC{sub ANN1}=0.88 [0.82,0.92]) as that of the second observer and the corresponding ANN (AUC{sub OBS2}=0.87 [0.83,0.91] vs AUC{sub ANN2}=0.90 [0.85,0.94]). Moreover, the ANN-predicted indices were generated in a fraction of the time required to obtain the observer-assigned indices. Conclusions: ANN-predicted assessability indices performed similar to observer-assigned assessability indices in identifying images with diagnostic calcium scores from the physical dynamic cardiac phantom. The results of this study demonstrate the potential of using computerized methods for identifying images with diagnostic clinical indices in cardiac CT images.

60 APPLIED LIFE SCIENCES↗

Alanine/EPR dosimetry applied to the verification of a total body irradiation protocol and treatment planning dose calculation using a humanoid phantom

Purpose: To avoid complications in total body irradiation (TBI), it is important to achieve a homogeneous dose distribution throughout the body and to deliver a correct dose to the lung which is an organ at risk. The purpose of this work was to validate the TBI dose protocol and to check the accuracy of the 3D dose calculations of the treatment planning system. Methods: Dosimetry based on alanine/electron paramagnetic resonance (EPR) was used to measure dose at numerous locations within an anthropomorphic phantom (Alderson) that was irradiated in a clinical TBI beam setup. The alanine EPR dosimetry system was calibrated against water calorimetry in a Co-60 beam and the absorbed dose was determined by the use of ''dose-normalized amplitudes'' A{sub D}. The dose rate of the TBI beam was checked against a Farmer ionization chamber. The phantom measurements were compared to 3D dose calculations from a treatment planning system (Pinnacle) modeled for standard dose calculations. Results: Alanine dosimetry allowed accurate measurements which were in accordance with ionization chamber measurements. The combined relative standard measurement uncertainty in the Alderson phantom was U{sub r}(A{sub D})=0.6%. The humanoid phantom was irradiated to a reference dose of 10 Gy, limiting the lung dose to 7.5 Gy. The ratio of the average measured dose midplane in the craniocaudal direction to the reference dose was 1.001 with a spread of {+-}4.7% (1 sd). Dose to the lung was measured in 26 locations and found, in average, 1.8% lower than expected. Lung dose was homogeneous in the ventral-dorsal direction but a dose gradient of 0.10 Gy cm{sup -1} was observed in the craniocaudal direction midline within the lung lobe. 3D dose calculations (Pinnacle) were found, in average, 2% lower compared to dose measurements on the body axis and 3% lower for the lungs. Conclusions: The alanine/EPR dosimetry system allowed accurate dose measurements which enabled the authors to validate their TBI dose protocol. Dose calculations based on a collapsed cone convolution dose algorithm modeled for regular treatments are accurate within 3% and can further be improved when the algorithm is modeled for TBI.

61 RADIATION PROTECTION AND DOSIMETRY↗