Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase two”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Numerical Analysis of Cavitation-Induced Two-Phase Fluid Transients in Cryogenic Feedlines Using Finite Volume Procedure

This article presents a numerical investigation of the cavitation induced fluid transient in cryogenic feedline due to sudden closure of the valve A one dimensional numerical model based on finite volume procedure consisting of nodes and branches using Generalized Fluid System Simulation Program ( has been employed for the prediction of pressure variations The unsteady friction formulation accurately determines wall shear stress, and a homogeneous mixture model is used for two phase flow modeling Numerical results obtained with the present formulation are compared with experimental results and Method of Characteristic ( based results It is observed that low residual in flow variable calculation improves the solution providing numerically stable results GFSSP is able to reproduce the fluid transient peak due to vapor collapse Subsequently, it can retain the shape of pressure wave for two phase fluid transients, but it is dampening faster compared to experiments Further investigation is required with set of experiments to validate the present numerical approach for different experimental data.

Fluid Transient↗

Two-phase flow

An experimental program to characterize the spray from candidate nozzles for icing-cloud simulation is discussed. One canidate nozzle, which is currently used for icing research, has been characterized for flow and drop size. The median-volume diameter (MVD) from this air-assist nozzle is compared with correlations in the literature. The new experimental spray facility is discussed, and the drop-size instruments are discussed in detail. Since there is no absolute standard for drop-size measurements and there are other limitations, such as drop -size range and velocity range, several instruments are used and results are compared. A two-phase model was developed at Pennsylvania State University. The model uses the k-epsilon model of turbulence in the continous phase. Three methods for treating the discrete phase are used: (1) a locally homogeneous flow (LHF) model, (2) a deterministic separated flow (DSF) model, and (3) a stochastic separated flow (SSF) model. In the LHF model both phases have the same velocity and temperature at each point. The DSF model provides interphase transport but ignores the effects of turbulent fluctuations. In the SSF model the drops interact with turbulent eddies whose properties are determined by the k-epsilon turbulence model. The two-phase flow model has been extended to include the effects of evaporation and combustion.

Tacina, Robert R.↗

Analytical investigation of two-phase heat transfer in a porous matrix.

One-dimensional two-phase flow transpiration cooling through porous metals is studied analytically. The differential energy equations for the solid and for the liquid with temperature dependent properties are solved simultaneously with a semi-empirical pressure drop correlation. Formulation of the problem both assuming thermal equilibrium (assumes Clausius-Claperyon equation pertains) and nonequilibrium (defines a parameter representing fraction of energy transferred to mixture which contributes to evaporation) is given. Representative solutions showing the influences and significance of the controlling dimensionless parameters are presented.

Frost, W.↗

Experimental investigation of two-phase heat transfer in a porous matrix.

One-dimensional two-phase flow transpiration cooling through porous metal is studied experimentally. The experimental data is compared with a previous one-dimensional analysis. Good agreement with calculated temperature distribution is obtained as long as the basic assumptions of the analytical model are satisfied. Deviations from the basic assumptions are caused by nonhomogeneous and oscillating flow conditions. Preliminary derivation of nondimensional parameters which characterize the stable and unstable flow conditions is given. Superheated liquid droplets observed sputtering from the heated surface indicated incomplete evaporation at heat fluxes well in access of the latent energy transport. A parameter is developed to account for the nonequilibrium thermodynamic effects. Measured and calculated pressure drops show contradicting trends which are attributed to capillary forces.

Von Reth, R.↗

Coal-Face Fracture With A Two-Phase Liquid

In new method for mining coal without explosive, two-phase liquid such as CO2 and water, injected at high pressure into deeper ends of holes drilled in coal face. Liquid permeates coal seam through existing microfractures; as liquid seeps back toward face, pressure eventually drops below critical value at which dissolved gas flashvaporizes, breaking up coal.

Collins, E. R., Jr.↗

A Von Karman integral approach to a two phase boundary layer problem

A Von Karman integral approximation of a two phase boundary layer is developed for bodies of arbitrary shape. The flow field considered is that of the injection of water through a porous airfoil. A solution for the special case of a flat plate is presented. The equations for the airfoil solution are developed and possible effects on airflow separation are discussed.

Henry, R.↗

Two-Phase Bidirectional Heat Exchanger

Heat exchanger transfers heat from one two-phase thermal loop to another. Condenses vapor in one loop while evaporating liquid in other. Transfers heat with very small drops in temperature and pressure, and efficiently joins heat pipes thermally without mixing of their working fluids. Several such heat exchangers used to build long, complex multiloop heat-control systems. Exchanger bidirectional: transfers heat in reverse, condensing on normally evaporating side, and vice versa. Can warm equipment it normally cools, without using auxiliary heater. In reverse transfer, wicks on evaporating side supply liquid continuously by capillary action; reverse-flow pump not needed. Design modified for other working fluids and larger heat-transfer rates.

Kroliczek, Edward↗

Two-Phase Cryogenic Heat Exchanger for the Thermodynamic Vent System

A two-phase cryogenic heat exchanger for a thermodynamic vent system was designed and analyzed, and the predicted performance was compared with test results. A method for determining the required size of the Joule-Thomson device was also developed. Numerous sensitivity studies were performed to show that the design was robust and possessed a comfortable capacity margin. The comparison with the test results showed very similar heat extraction performance for similar inlet conditions. It was also shown that estimates for Joule- Thomson device flow rates and exit quality can vary significantly and these need to be accommodated for with a robust system design.

Christie, Robert J.↗

Interaction terms in gas-solid two-phase flows

From both experimental data and theoretical results of the two-phase flow, the complete expression of the interaction force between a gas and solid particles at low Reynolds number flow is obtained. The interaction force contains two terms: one is proportional to the difference between the velocities of the gas and the solid particle with a coefficient as a function of volume fraction Z and the other is proportional to the product of the total pressure of the mixture and the gradient of solid volume fraction. The second term is new. When Z tends to 0, the completion expression of interaction force reduces to the well-known Stokes formula.

Pai, S. I.↗

Conceptual design for spacelab two-phase flow experiments

KC-135 aircraft tests confirmed the gravity sensitivity of two phase flow correlations. The prime component of the apparatus is a 1.5 cm dia by 90 cm fused quartz tube test section selected for visual observation. The water-cabin air system with water recycle was a clear choice for a flow regime-pressure drop test since it was used satisfactorily on KC-135 tests. Freon-11 with either overboard dump or with liquid-recycle will be used for the heat transfer test. The two experiments use common hardware. The experimental plan covers 120 data points in six hours with mass velocities from 10 to 640 kg/sec-sq m and qualities 0.01 to 0.64. The apparatus with pump, separator, storage tank and controls is mounted in a double spacelab rack. Supporting hardware, procedures, measured variables and program costs are defined.

Bradshaw, R. D.↗

Cryogenic Two-Phase Flight Experiment: Results overview

This paper focuses on the flight results of the Cryogenic Two-Phase Flight Experiment (CRYOTP), which was a Hitchhiker based experiment that flew on the space shuttle Columbia in March of 1994 (STS-62). CRYOTP tested two new technologies for advanced cryogenic thermal control; the Space Heat Pipe (SHP), which was a constant conductance cryogenic heat pipe, and the Brilliant Eyes Thermal Storage Unit (BETSU), which was a cryogenic phase-change thermal storage device. These two devices were tested independently during the mission. Analysis of the flight data indicated that the SHP was unable to start in either of two attempts, for reasons related to the fluid charge, parasitic heat leaks, and cryocooler capacity. The BETSU test article was successfully operated with more than 250 hours of on-orbit testing including several cooldown cycles and 56 freeze/thaw cycles. Some degradation was observed with the five tactical cryocoolers used as thermal sinks, and one of the cryocoolers failed completely after 331 hours of operation. Post-flight analysis indicated that this problem was most likely due to failure of an electrical controller internal to the unit.

Swanson, T.↗