Search NASA⌕ Search

SEARCH · Search NASA

Results for “photodetector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Evidence for ionization damage in mid-wave infrared nBn detectors

The effects of 63 MeV proton and 60Co gamma irradiation on the operation of 4.3 μm cutoff nBn photodetectors are demonstrated separately, and both are shown to yield a total ionizing dose (TID) effect. The effect is shown here in an InAsSbBi nBn detector and has been observed in other bulk alloy nBn detectors, and is unusual as it is notably absent in superlattice nBn detectors. The non-antireflection coated detectors exhibit a pre-radiation quantum efficiency of 17% at 3.3 μm wavelength and a dark current density of 50 μA/cm2, or roughly 300× the Rule 07 expectation, at their ideal operating voltage of −0.4 V bias at 150 K. Step-wise proton irradiation and in situ measurement indicate that the dark current increases to about 400× Rule 07 at the highest proton dose level of 150 krad(Si) (9.10 × 1011 p+/cm2), while the quantum efficiency is degraded at a relatively faster rate than the majority of analogous detectors characterized by our lab. Both the photocurrent and dark current are also shown to exhibit a turn-on voltage magnitude reduction of 100 mV following either gamma or proton irradiation, a trend which is attributable to negative trapped charge at the barrier interface (TID effect). This theory is further supported by an observed capacitance density magnitude reduction with dose and affirmed with Silvaco TCAD simulations. Following both proton exposure and subsequent anneal and gamma exposure and subsequent anneal; dark current, photocurrent, and CV all approach their pre-radiation baseline values.

Physics↗

Fast photodiode arrays for high frequency fluctuation measurements of reconnecting flux ropes

An array of compact, high-bandwidth (>200 MHz) and low-cost optical photodiodes has been developed and implemented on the PHASe MApping (PHASMA) experiment. Using purpose-built electronics, an array of 16 photodetectors was constructed and used to monitor broadband (1–5 MHz) fluctuations in light intensity emitted by flux ropes undergoing electron-only magnetic reconnection. These measurements reveal a swath of oscillatory behavior, including wave propagation inward toward the diffusion region at approximately the local electron Alfvén speed. Custom 3D-printed collection optics and mounting hardware allow quick reconfiguration of the array for radial or axial measurements. The electronics design is flexible enough to be used with other current-sourcing transducers, such as avalanche photodiodes; silicon photomultipliers; and infrared, x-ray, and UV photodiodes. A noise-rejecting electrical layout allows for low-noise operation close to pulsed plasma discharges. A 16-channel, 64-pixel tomographic array was constructed and initial reconstructions are presented.

Instruments & Instrumentation↗

Fast and efficient Sb-based type-II phototransistors integrated on silicon

Increasing the energy efficiency and reducing the footprint of on-chip photodetectors enable dense optical interconnects for emerging computational and sensing applications. While heterojunction phototransistors (HPTs) exhibit high energy efficiency and negligible excess noise factor, their gain-bandwidth product (GBP) has been inferior to that of avalanche photodiodes at low optical powers. Here, we demonstrate that utilizing type-II energy band alignment in an Sb-based HPT results in six times smaller junction capacitance per unit area and a significantly higher GBP at low optical powers. These type-II HPTs were scaled down to 2 μm in diameter and fully integrated with photonic waveguides on silicon. Thanks to their extremely low dark current and high internal gain, these devices exhibit a GBP similar to the best avalanche devices (∼270 GHz) but with one order of magnitude better energy efficiency. Their energy consumption is about 5 fJ/bit at 3.2 Gbps, with an error rate below 10−9 at −25 dBm optical power at 1550 nm. These features suggest new opportunities for creating highly efficient and compact optical receivers based on phototransistors with type-II band alignment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge transfer in transition metal dichalcogenide alloy heterostructures

Two-dimensional (2D) transition metal dichalcogenides and their alloys provide a unique platform for exploring interlayer charge transfer in van der Waals heterostructures. These structures are crucial for advancing the next-generation electronic, optoelectronic, and quantum devices. In this study, interlayer charge transfer in heterostructures composed of MoSe 2 , MoS 2 , and their alloy, MoSSe, is investigated using transient absorption, Raman, and photoluminescence spectroscopy. The experimental results reveal that electron transfer in the alloy heterostructures, MoSSe/MoS 2 and MoSe 2 /MoSSe, is faster than in the pure MoSe 2 /MoS 2 heterostructure, despite the smaller conduction band offsets of the alloy systems. Raman spectroscopy confirms that alloy layers support phonon modes matching those of the pure layers, aligning with theoretical models of phonon-assisted interlayer charge transfer. Additionally, efficient hole transfer is observed in both alloy heterostructures. The findings suggest transition metal dichalcogenides alloys can be used for engineering heterostructures with desired charge transfer properties. By leveraging compositionally tunable band gaps and optical properties, alloy-based heterostructures offer opportunities for designing tailored materials suitable for diverse applications such as photodetectors, light-emitting devices, and flexible electronics. Furthermore, the ultrafast charge transfer observed in these systems provides insights into the fundamental mechanisms governing interlayer interactions in 2D materials.

2D material↗

Comparison of time-resolved photoluminescence and deep-level transient spectroscopy defect evaluations in an InAs nBn detector subjected to in situ and ex situ 63 MeV proton irradiation

Deep-level transient spectroscopy and temperature-dependent time-resolved photoluminescence experiments are performed on identical InAs nBn photodetector structures as a function of in situ and ex situ 63 MeV proton irradiation to assess their generation and recombination dynamics. Pre-irradiation, the n-type InAs absorbing region, exhibits a steadily increasing minority carrier lifetime with increasing temperature, providing evidence that excited minority carriers may be recombining via shallow defect levels. From deep-level transient spectroscopy, two features are found between 10 and 275 K: a low temperature broad “shoulder,” which suggests emission from multiple shallow electron defect levels with energies <29 meV and a high temperature minimum occurring at ∼230 K with an activation energy of 539 meV, which suggests a defect in the barrier layer in the device. Two similar nBn detectors are then subjected to 63 MeV proton irradiation in step doses and measured between steps. One experiment is performed in situ with an nBn held at ∼10 K during dosing, and the other experiment is performed ex situ with a similar nBn held at room temperature for dosing. The ex situ dosing results in an evaluation of the defect introduction rate that is three to four times lower than in situ due to partial annealing of the proton-induced displacement damage at room temperature. The results of these two experiments are then compared with the dose-dependent recombination rate analysis, resulting in an estimated recombination defect cross section of 1.6 × 10 −13 cm 2 for the shallow shoulder defect.

Carrasco, Rigo A. [Air Force Research Laboratory (↗

Molecular surface programming of rectifying junctions between InAs colloidal quantum dot solids

Heavy-metal-free III–V colloidal quantum dots (CQDs) show promise in optoelectronics: Recent advancements in the synthesis of large-diameter indium arsenide (InAs) CQDs provide access to short-wave infrared (IR) wavelengths for three-dimensional ranging and imaging. In early studies, however, we were unable to achieve a rectifying photodiode using CQDs and molybdenum oxide/polymer hole transport layers, as the shallow valence bandedge (5.0 eV) was misaligned with the ionization potentials of the widely used transport layers. This occurred when increasing CQD diameter to decrease the bandgap below 1.1 eV. Here, we develop a rectifying junction among InAs CQD layers, where we use molecular surface modifiers to tune the energy levels of InAs CQDs electrostatically. Previously developed bifunctional dithiol ligands, established for II-VI and IV-VI CQDs, exhibit slow reaction kinetics with III-V surfaces, causing the exchange to fail. Here, we study carboxylate and thiolate binding groups, united with electron-donating free end groups, that shift upward the valence bandedge of InAs CQDs, producing valence band energies as shallow as 4.8 eV. Photophysical studies combined with density functional theory show that carboxylate-based passivants participate in strong bidentate bridging with both In and As on the CQD surface. The tuned CQD layer incorporated into a photodiode structure achieves improved performance with EQE (external quantum efficiency) of 35% (>1 μm) and dark current density < 400 nA cm -2 , a >25% increase in EQE and >90% reduced dark current density compared to the reference device. This work represents an advance over previous III-V CQD short-wavelength IR photodetectors (EQE < 5%, dark current > 10,000 nA cm -2 ).

36 MATERIALS SCIENCE↗

Thermoelectric properties of antimony selenide hexagonal nanotubes

Antimony selenide (Sb 2 Se 3 ) is a material widely used in photodetectors and relatively new as a possible material for thermoelectric applications. Taking advantage of the new properties after nanoscale fabrication, this material shows great potential for the development of efficient low temperature thermoelectric devices. Here, for this paper, we study the synthesis, the crystal properties and the thermal and thermoelectric transport response of Sb 2 Se 3 hexagonal nanotubes (HNT) in the temperature range between 120 and 370 K. HNT have a moderate electrical conductivity ~10 2 S m -1 while maintaining a reasonable Seebeck coefficient ~430 μV K -1 at 370 K. The electrical conductivity in Sb 2 Se 3 HNT is about 5 orders of magnitude larger and its thermal conductivity one half of what is found in bulk. Moreover, the calculated figure of merit (ZT) at room temperature is the largest value reported in antimony selenide 1D structures.

36 MATERIALS SCIENCE↗

Revealing charge carrier dynamics and transport in Te-doped GaAsSb and GaAsSbN nanowires by correlating ultrafast terahertz spectroscopy and optoelectronic characterization

Recent advances in the growth of III-V semiconductor nanowires (NWs) hold great promise for nanoscale optoelectronic device applications. It is established that a small amount of nitrogen (N) incorporation in III-V semiconductor NWs can effectively red-shift their wavelength of operation and tailor their electronic properties for specific applications. Still, understanding the impact of N incorporation on non-equilibrium charge carrier dynamics and transport in semiconducting NWs is critical in achieving efficient semiconducting NW devices. In this work, ultrafast optical pump-terahertz probe spectroscopy has been used to study non-equilibrium carrier dynamics and transport in Te-doped GaAsSb and dilute nitride GaAsSbN NWs, with the goal of correlating these results with electrical characterization of their equilibrium photo-response under bias and low-frequency noise characteristics. Nitrogen incorporation in GaAsSb NWs led to a significant increase in the carrier scattering rate, resulting in a severe reduction in carrier mobility. Carrier recombination lifetimes of 33 ± 1 picoseconds (ps) and 147 ± 3 ps in GaAsSbN and GaAsSb NWs, respectively, were measured. The reduction in the carrier lifetime and photoinduced optical conductivities are due to the presence of N-induced defects, leading to deterioration in the electrical and optical characteristics of dilute nitride NWs relative to the non-nitride NWs. Finally, we observed a very fast rise time of ~2 ps for both NW materials, directly impacting their potential use as high-speed photodetectors.

36 MATERIALS SCIENCE↗

Reflectivity and PDE of VUV4 Hamamatsu SiPMs in liquid xenon

Considering reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE . Little information is currently available about reflectivity and PDE in liquid noble gases, because such measurements are difficult to conduct in a cryogenic environment and at short enough wavelengths. Here we report a measurement of specular reflectivity and relative PDE of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 μ m micro-cells conducted with xenon scintillation light ( ~ 175 nm) in liquid xenon. The specular reflectivity at 15 o incidence of three samples of VUV4 SiPMs is found to be 30.4 ± 1.4%, 28.6 ± 1.3%, and 28.0 ± 1.3%, respectively. The PDE at normal incidence differs by ± 8% (standard deviation) among the three devices. The angular dependence of the reflectivity and PDE was further measured for one of the SiPMs. Both the reflectivity and PDE decrease as the angle of incidence increases. This is the first measurement of an angular dependence of PDE and reflectivity of a SiPM in liquid xenon.

47 OTHER INSTRUMENTATION↗

Measurement of Liquid Argon Scintillation Light Properties by means of an Alpha Source placed inside the CERN 10-PMT LAr Detection System

A particle detection system that exploits the scintillation light produced by ionizing particles in liquid argon (LAr) has been assembled at CERN. The system is based on 10 large-area photomultiplier tubes (PMT) immersed in a 1500-liter dewar filled with liquid argon and equipped with an extendible feed-through and mechanical support for an alpha source (241Am). The position of the source can be changed with respect to the PMT plane in vertical and horizontal directions. Arrays of silicon photomultiplier (SiPM) photodetectors, integrated in the source support, are used for the data acquisition trigger and to define the t0 of the light generation. PMT and SiPM signals can be recorded at different distances and different positions allowing the measurement of some of the LAr scintillation light properties. The system was studied and characterized in detail, and physics results on LAr scintillation properties are expected soon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and calibration of an optically segmented single volume scatter camera for neutron imaging

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5mm &#x00d7; 5mm &#x00d7; 200mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6x6mm J-Series sensors arranged in an 8 &#x00d7; 8 array. We report on the design details, including component selections, mechanical design and assembly, and the electronics system. The described design leveraged existing off-the-shelf solutions to support the rapid development of a phase 1 prototype. Several valuable lessons were learned from component and system testing, including those related to the detector's mechanical structure and electrical crosstalk that we conclude originates in the commercial photodetector arrays and the associated custom breakout cards. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 3090ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using 22 Na and 90 Sr, respectively, reporting an average resolution of 12.07±0.03mm for energy depositions between 900keVee and 1000keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of 14.86+-0.29mm for depositions between 900keVee and 1000keVee. The coincident time resolution reported between pairs of bars measured up to 400ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.

47 OTHER INSTRUMENTATION↗

Single photoelectron identification with Incom LAPPD 38

Incom Inc. Large Area Picosecond Photodetector (LAPPD) 38 has been tested at Jefferson Lab to identify single-photoelectron signals to assess the potential of this type of device for future applications in Cherenkov light detection. Here, single-photoelectron signals were clearly detected if a tight masking of photons impinging on the photocathode was used compared to the pixelation of the charge collection signal board.

47 OTHER INSTRUMENTATION↗

Performance of photosensors in a high-rate environment for gas Cherenkov detectors

We report the solenoidal large intensity device (SoLID) at Jefferson Lab will push the boundaries of luminosity for a large-acceptance detector, which necessitates the use of a light-gas threshold Cherenkov counter for online event selection. Due to the high luminosity, the single-photon background rate in this counter can exceed 160 kHz/cm 2 at the photosensors. Therefore, it is essential to validate the high-rate limits of the planned photosensors and readout electronics in order to mitigate the risk of failure. We report on the design and an early set of studies carried out using a small Cherenkov counter in a high-rate environment up to 60 kHz/cm 2 , in Hall C at Jefferson Lab. Commercially available multi-anode photomultipliers (MaPMT) and low-cost large-area picosecond photodetectors (LAPPD) were tested using the JLab FADC250 modules for readout. The test beam results show that the MaPMT array and the internal stripline LAPPD can detect and identify single-electron and pair-production events in high-rate environments. Due to its higher quantum efficiency, the MaPMT array provided a better separation between the single-electron and the pair-production events compared to the internal stripline LAPPD. A GEANT4 simulation confirms the beam test performance of our counter device.

47 OTHER INSTRUMENTATION↗

Advances in the Large Area Picosecond Photo-Detector (LAPPD TM ): 8" × 8" MCP-PMT with Capacitively Coupled Readout

Abstract We present advances made in the Large Area Picosecond Photodetector (LAPPD), an 8" × 8" microchannel plate photomultiplier tube (MCP-PMT), since pilot production was initiated at Incom, Inc. in 2018. The Gen-I LAPPD utilizes a stripline anode for direct charge readout. The novel Gen-II LAPPD employs an internal resistive thin-film which capacitively couples to a customizable external signal readout board, streamlining production and increasing customer flexibility. The Gen-II LAPPD, with an active area of 373 cm 2 , is capable of high single photoelectron (PE) gain of ∼10 7 , low dark rates (∼1 kHz/cm 2 ), single PE (SPE) timing resolution of ∼65 ps, and 𝒪(mm) position resolution. Coupled with a UV-grade fused silica window, the LAPPD features a high quantum efficiency (QE) bialkali photocathode of >30% at 365 nm with spectral response down to ∼165 nm. The LAPPD is an excellent candidate for electromagnetic calorimeter (ECAL) timing layers, photon-based neutrino detectors, high energy collider experiments, medical imaging systems, and nuclear non-proliferation applications.

Instruments & Instrumentation↗

Performance of a coarsely pixelated LAPPD photosensor for the SoLID gas Cherenkov detectors

The SoLID spectrometer's gas Cherenkov counters require photosensors that operate in a high luminosity and high background environment. The reference design features arrays of 9 or 16 tiled multi-anode photomultipliers (MaPMTs), distributed across 32 sectors, to serve the light-gas and heavy-gas Cherenkov counters, respectively. To assess the viability of a pixelated INCOM Large Area Picosecond Photodetector (LAPPD TM ) as an alternative photosensor to replace MaPMT arrays in either detector, we evaluated its performance under realistic SoLID running conditions in Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). The results of this test confirmed that the coarse-pixelated (2.5 × 2.5 cm 2 pixel size) LAPPD is capable of handling the total projected signal and background rates of the three pillar SoLID experiments. The tested photosensor detected Cherenkov signals with the capability of separating single-electron events from pair production events while rejecting background. Although the design was not aimed at ring-imaging Cherenkov detectors, Cherenkov disk images were captured in two different gas radiators. Through a direct comparison with a GEANT4 simulation, we confirmed the experimental performance of the LAPPD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GRAPH — an readout ASIC for large MCP based detectors

We present a programmable 16 channel, mixed signal, low power readout ASIC, having the project historically named Gigasample Recorder of Analog waveforms from a PHotodetector (GRAPH). It is designed to read large aperture single photon imaging detectors using micro channel plates for charge multiplication, and measuring the detector's response on crossed strips anodes to extrapolate the incoming photon position. Each channel consists of a fast, low power and low noise charge sensitive amplifier, which provides a myriad of coarse and fine programmable options for gain and shaping settings. Further, the amplified signal is recorded using, to our knowledge novel, the Hybrid Universal sampLing Architecture (HULA) ADC. A kind of mixed signal double buffer memory, that enables concurrent waveform recording, and selected event digitized data extraction. The sampling frequency is freely adjustable between few kHz up to 125 MHz, while the chip's internal digital memory holds a history 2048 samples for each channel, with a digital headroom of 12 bits. An optimized region of interest sample-read algorithm allows to extract the information just around the event pulse peak, while selecting the next event, thus substantially reducing the operational dead time. The chip is designed in 130 nm TSMC CMOS technology, and its power consumption is around 47 mW per channel.

47 OTHER INSTRUMENTATION↗

First light from beam neutrinos on an LAPPD in ANNIE

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is both a physics experiment and a technology testbed for next-generation light-based neutrino detection. In this paper, we report the first demonstration of a fully integrated Large Area Picosecond Photodetector (LAPPD) operating in a running neutrino beam experiment. Particular focus is given to the design, commissioning, and successful deployment of the Packaged ANNIE LAPPD (PAL), a waterproof, self-triggering module incorporating fast waveform digitization and precision timing synchronized to the ANNIE detector subsystems. We identify beam-correlated LAPPD data frames consistent with charged-current neutrino interactions observed in multiple detector subsystems, establishing the first detection of neutrino-induced Cherenkov light with an LAPPD. These results validate the system-level performance of LAPPDs under realistic experimental conditions — including long-term stability, timing synchronization, and event matching with conventional PMT and muon detector systems — marking a critical step toward their deployment in future large-scale neutrino and particle detectors.

Cherenkov detectors↗

Reconstruction of neutrino events in the Accelerator Neutrino Neutron Interaction Experiment. Part I

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) was designed to reconstruct neutrino events from the Fermilab Booster Neutrino Beam (BNB) with the parallel goals of measuring neutron production in interactions with oxygen and serving as a testbed for new technology. The ANNIE detector consists of a 26-ton water Cherenkov target tank instrumented with conventional photomultiplier tubes (PMTs), a downstream tracking muon spectrometer, and an upstream double wall of plastic scintillator to serve to veto charged particles incoming from neutrino events that occur upstream of the experimental setup. ANNIE has also deployed multiple Large-Area Picosecond PhotoDetectors (LAPPDs) and a test vessel of water-based liquid scintillator (WbLS). This paper describes the event reconstruction performance of the detector before implementation of these novel technologies, which will serve as a baseline against which their impact can be measured. That said, even the techniques used for event reconstruction using only the conventional PMT array and muon spectrometer are significantly different than those used in other water Cherenkov detectors due to the small size of ANNIE (which makes nanosecond-scale timing not as useful as in a large detector) and the availability of reconstruction information from the tracking muon spectrometer. We demonstrate that combining the information from these two elements into a single fit using only pattern recognition yields a muon vertex uncertainty of 60 cm, a directional uncertainty of 13.2 degrees, and energy reconstruction uncertainty of about 10% for BNB muon neutrino Charged Current Zero Pion (CC0π) events.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗