A method for correcting aspect solution errors in ROSAT HRI observations of compact sources

X-ray point sources observed with the ROSAT High Resolution Imager (HRI) often appear elongated over scales of approximately 5 sec-10 sec from the image core. This elongation has been attributed to errors in the attitude correction as the satellite is wobbled during the observations, and affects sources with both soft and hard X-ray spectra. In this paper, I report the results of an attempt to rid a high signal-to-noise observation of the soft X-ray point source HZ 43 of its characteristic elongation. I divided the observation into 181 separate images, each containing photons from only a small region on the detector through which the source passed during the satellite's wobble. By measuring the positions of the individual image centroids, I found clear evidence for systematic offsets from a common mean by up to approximately +/- 3 sec in both right ascension and declination as a function of phase in the satellite wobble. Shifting the subimages to a common center and then restacking them into a single image measurably improved the symmetry of the point-spread function. HRI observations are wobbled primarily to smooth out variations in the pixel-to-pixel sensitivity of the detector and also to extend the lifetime of the microchannel plates in the detector since these decay at a given location as a function of the number of photons detected. However, the elongations introduced by the aspect errors inhibit the identification of possible extended X-ray emission associated with sources such as pulsars and active galactic nuclei. In light of these results, I suggest that until the aspect errors are understood, observations of compact sources, where this effect may be important, should not be wobbled.

Morse, Jon A.↗

SCA Test Report: H4RG-20828 WFIRST

This report summarizes the measured performance for the Sensor Chip Assembly (SCA), which is identified in Table 1. The SCA architecture is a substrate-removed HgCdTe detector with an area of4096x4096 pixels (with a reference pixel area of four pixels deep around all four sides, available to substitute corresponding image pixels) and a pixel pitch of 10 μm. This SCA has been tested at the Goddard Space Flight Center (GSFC/NASA) Detector Characterization Laboratory (DCL). Teledyne (the vendor) classifies its detectors into different grades based on testing performed at its facility. The classification of this SCA and the tested dates are included in Table 1 below.The tests performed on this array are derived from the document WFIRST-PROC-09220_WFIRST-SCA-ATP_-.docx. A summary of the test parameters, requirements, and test results is presented in Table 2. The details of each test are subsequently described in the report. In the Summary (Table 2), SCA results are reported at an operating temperature of 95K, and 1.0 V bias voltage. In the detailed section of each test, the results for 90 K (1.0V bias voltage) and 95 K (0.5V bias voltage) are also reported. For all cases, the frame time used is 2.764 seconds. Reference pixel correction was applied to every raw frame.

Laddawan Miko↗

Progress Towards High-Sensitivity Arrays of Detectors of Sub-mm Radiation Using Superconducting Tunnel Junctions with Integrated Radio Frequency Single-Electron Transistors

For high resolution imaging and spectroscopy in the FIR and submillimeter, space observatories will demand sensitive, fast, compact, low-power detector arrays with 104 pixels and sensitivity less than 10(exp -20) W/Hz(sup 0.5). Antenna-coupled superconducting tunnel junctions with integrated rf single-electron transistor readout amplifiers have the potential for achieving this high level of sensitivity, and can take advantage of an rf multiplexing technique. The device consists of an antenna to couple radiation into a small superconducting volume and cause quasiparticle excitations, and a single-electron transistor to measure current through junctions contacting the absorber. We describe optimization of device parameters, and results on fabrication techniques for producing devices with high yield for detector arrays. We also present modeling of expected saturation power levels, antenna coupling, and rf multiplexing schemes.

Stevenson, T. R.↗

Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing

A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe 44+ , Xe 47+ , and Xe 51+ , based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.

47 OTHER INSTRUMENTATION↗

Image Alignment and Flat-Field Correction of Film and Computed Radiography Images on the LLNL Flash Testbed

Computed radiography (CR) imaging plates and film are used in HEAF firing tanks and in the NDE group. The imaging plates allow for the creation of high-resolution digital images with flash X-ray (FXR). A typical treatment of flash X-ray radiographs is flat-field correction, where the image from an experiment is normalized by a “flat-field” or “bright-field” image. This flat-field image is taken in an identical configuration to the experimental image, but without the object or experiment in the field of view (FOV). This treatment reduces spatial effects from the FXR spot size and detector misalignment, as each pixel value in the corrected image represents a ratio of collected radiation with the object in FOV to the collected radiation without the object in FOV. One challenge in the creation of a corrected image is the misalignment of the CR plate or film pack between capturing the flat-field image and the experimental image. Fiducial structures can remedy this issue. Small (3.18mm) stainless steel ball bearings serve as good fiducial structures due to their small size and high radiographic contrast. Spheres are view-agnostic geometry, always presenting a circular cross section no matter the orientation. This process was developed for images from the flash X-ray testbed. The flash testbed was used to compare the X-ray transmission at different thicknesses of aluminum and copper step wedges. Each step wedge section is a rectangular shape, so evaluation is made much simpler if the rectangles are not rotated with respect to the image. This alignment process aligns the object and flat-field images together and leaves the rectangles of each step aligned with the image.

36 MATERIALS SCIENCE↗

A large imaging array CCD program

Test results on charge coupled device (CCD) imaging arrays (100 x 160 pixel and 400 x 400 pixel) employed as imaging detectors are reported, along with expected low light level (LLL) performance. Reasons for selection of a thinned backside-illuminated buried-channel three-phase CCD variant are indicated. The LLL performance and long storage time capability of the CCD imaging array recommend it for stellar photometry, detection and tracking of faint objects, and other astronomical applications.

Vescelus, F. E.↗

Wavelength error analysis in a multiple-beam Fizeau laser wavemeter having a linear diode array readout

An estimate of the wavelength accuracy of a laser wavemeter is performed for a system consisting of a multiple-beam Fizeau interferometer and a linear photosensor array readout. The analysis consists of determining the fringe position errors which result when various noise sources are included in the fringe forming and detection process. Two methods of estimating the fringe centers are considered: (1) maximum pixel current location, and (2) average pixel location for two detectors with nearly equal output currents. Wavelength error results for these two methods are compared for some typical wavemeter parameters.

Robinson, D. M.↗

A 58 x 62 pixel Si:Ga array camera for 5 - 14 micron astronomical imaging

A new infrared array camera system has been successfully applied to high background 5 - 14 micron astronomical imaging photometry observations, using a hybrid 58 x 62 pixel Si:Ga array detector. The off-axis reflective optical design incorporating a parabolic camera mirror, circular variable filter wheel, and cold aperture stop produces diffraction-limited images with negligible spatial distortion and minimum thermal background loading. The camera electronic system architecture is divided into three subsystems: (1) high-speed analog front end, including 2-channel preamp module, array address timing generator, bias power suppies, (2) two 16 bit, 3 microsec per conversion A/D converters interfaced to an arithmetic array processor, and (3) an LSI 11/73 camera control and data analysis computer. The background-limited observational noise performance of the camera at the NASA/IRTF telescope is NEFD (1 sigma) = 0.05 Jy/pixel min exp 1/2.

Gezari, D. Y.↗

The AstroBiology Explorer (ABE) MIDEX Mission

The Astrobiology Explorer (ABE) is a Medium-Class Explorer (MIDEX) mission concept currently under study at NASA's Ames Research Center. ABE will conduct infrared (IR) spectroscopic observations with much better sensitivity than Infrared Space Observatory (ISO) or the Stratospheric Observatory for Infrared Astronomy program (SOFIA) in order to address outstanding astrobiologically important problems in astrochemistry as well as important astrophysical investigations. The core observational astrobiology program would make fundamental scientific progress in understanding the cosmic history of molecular carbon, the distribution of organic matter in the diffuse interstellar medium, tracing the chemical history of complex organic molecules in the interstellar medium, and the evolution of organic ices in young planetary systems. The ABE instrument concept includes a 0.5 m aperture Cassegrain telescope and a suite of three moderate resolution (R = 1000 - 4000) spectrographs which cover the entire lambda = 2.5-20 micron spectral region. Use of large format (1024 x 1024 pixel or larger) IR detector arrays will allow each spectrograph to cover an entire octave of spectral range per exposure without any moving parts. The telescope is passively cooled by a sun shade to below 65 K, and the detectors are cooled with solid H2 cryogen to approximately 8 K. ABE will be placed in an Earth-trailing one AU solar orbit by a Delta II launch vehicle. This energetically favorable orbit provides a low thermal background, affords good access to the entire sky over the one year mission lifetime, and allows adequate communications bandwidth. The spacecraft will be stabilized in three axes and will be pointed to an accuracy of approximately one arcsecond at ABE's several thousand individual scientific targets.

Greene, Thomas↗

ATIC Flight Data Processing

The first flight of the Advanced Thin Ionization Calorimeter (ATIC) experiment from McMurdo, Antarctica lasted for 16 days, starting in December, 2000. The ATIC instrument consists of a fully active 320-crystal, 960-channel Bismuth Germanate (BGO) calorimeter, 202 scintillator strips in 3 hodoscopes interleaved with a graphite target, and a 4480-pixel silicon matrix charge detector. We have developed an Object Oriented data processing package based on ROOT. In this paper, we will describe the data processing scheme used in handling the accumulated 45 GB of flight data. We will also discuss trigger issues by comparing the measured energy-dependent trigger efficiency with its simulation and calibration issues by considering the time-dependence of housekeeping information, etc.

Ahn, H. S.↗

ATIC Flight Data Processing

The first flight of the Advanced Thin Ionization Calorimeter (ATIC) experiment from McMurdo, Antarctica lasted for 16 days, starting on December 28, 2000. The ATIC instrument consists of a fully active 320-crystal, 960-channel Bismuth Germanate (BGO) calorimeter, 202 scintillator strips (808 channels) in 3 hodoscopes, interleaved with graphite target layers, and a 4480-pixel silicon matrix charge detector. We have developed an object-oriented data processing package based on ROOT. In this paper, we describe the data processing scheme used in handling the accumulated 45 GB of flight data. We discuss calibration issues, particularly the time-dependence of housekeeping information.

Ahn, H. S.↗

The AstroBiology Explorer (ABE) MIDEX Mission Concept

The Astrobiology Explorer (ABE) is a MIDEX mission concept under study at NASA's Ames Research Center in collaboration with Ball Aerospace & Technologies, Corp. ABE will conduct IR spectroscopic observations to address important problems in astrobiology, astrochemistry, and astrophysics. The core observational program would make fundamental scientific progress in understanding the distribution, identity, and evolution of ices and organic matter in dense molecular clouds, young forming stellar systems, stellar outflows, the general diffuse ISM, HII regions, Solar System bodies, and external galaxies. The ABE instrument concept includes a 0.6 m aperture Cassegrain telescope and two moderate resolution (R = 2000-3000) spectrographs covering the 2.5-16 micron spectral region. Large format (1024x 1024 pixel or larger) IR detector arrays and bandpass filters will allow each spectrograph to cover an entire octave of spectral range or more per exposure without any moving parts. The telescope will be cooled below 50K by a cryogenic dewar shielded by a sunshade. The detectors will be cooled to approximately 8K. The optimum orbital configuration for achieving the scientific objectives of the ABE mission is a low background, 1 AU Earth driftaway orbit requiring a Delta II launch vehicle. This configuration provides a low thermal background and allows adequate communications bandwidth and good access to the entire sky over the approximate 1-2 year mission lifetime.

Ennico, Kimberly↗

NTD-GE Based Microcalorimeter Performance

Our group has been developing x-ray microcalorimeters consisting of neutron transmutation doped (NTD) germanium thermistors attached to superconducting tin absorbers. We discuss the performance of single pixel x-ray detectors, and describe an array technology. In this paper we describe the read-out circuit that allows us to measure fast signals in our detectors as this will be important in understanding the primary cause of resolution broadening. We describe briefly a multiplexing scheme that allows a number of different calorimeters to be read out using a single JFET. We list the possible causes of broadening and give a description of the experiment which best demonstrates the cause of the primary broadening source. We mention our strategy for finding a suitable solution to this problem and describe briefly a technology for building arrays of these calorimeters.

Bandler, Simon↗

Atic Experiment: Flight Data Processing

The Advanced Thin Ionization Calorimeter (ATIC) is a balloon borne experiment to measure the composition and energy spectra of Z = 1 to 28 cosmic rays over the energy range approx. 30 GeV - 100 TeV. The instrument consists of a fully active 320-crystal Bismuth Germanate (BGO) calorimeter, 202 scintillator strips in 3 hodoscopes interleaved with a graphite target, and a 4480-pixel silicon matrix charge detector. ATIC has had two successful Long Duration Balloon flights from McMurdo, Antarctica: from 12/28/00 to 01/13/01 and from 12/29/02 to 01/18/03. We have developed the ATIC Data Processing System (ADPs), which is an Object Oriented data processing program based on ROOT. In this paper, we describe the processing scheme used in handling the flight data, especially the calibration method and the event reconstruction algorithm.

Ahn, H. S.↗

X-ray Polarimetry with an Active-Matrix Pixel Proportional Counter

We report the first results from an X-ray polarimeter with a micropattern gas proportional counter using an amorphous silicon active matrix readout. With 100% polarized X-rays at 4.5 keV, we obtain a modulation factor of 0.33+/- 0.03, confirming previous reports of the high polarization sensitivity of a finely segmented pixel proportional counter. The detector described here has a geometry suitable for the focal plane of an astronomical X-ray telescope. Amorphous silicon readout technology will enable additional extensions and improvements.

Black, J. K.↗

GOES SXI Monthly Project Status Report Lockheed Martin Advanced Technology Center Month of October 2004

The Lockheed Martin Missiles and Space Advanced Technology Center (LMATC) is developing three Solar X-ray Imager (SXI) instruments. Two are being built for flights on the National Oceanic and Atmospheric Administration's (NOAA) Geostationary Operational Environmental Satellites (GOES) N and O, and one will be a flight spare. The SXI development is being managed by the NASA Goddard Space Flight Center. The SXI will image the full sun at wavelengths between approximately 6 and 60 A with a detector having 5 arcsec pixels. The launch of the first SXI will be on GOES N and the second SXI is to be launched on on GOES O or P.

Morrison, Mons D.↗

The Infrared Spectrograph on the Spitzer Space Telescope

The Infrared Spectrograph (IRS) instrument on the Spitzer Space Telescope covered the 5 to 38 micron wavelength range at low and medium spectral resolutions. The instrument was very popular during Spitzers 5.7 year-long cold mission. Every year it attracted the most proposals, and garnered more observing hours, of any of the science instruments. This success was the culmination of a very long development period, where the instrument design changed radically. When the instrument was first selected by NASA in 1984 it was very complicated. As part of the overall reduction of the size of the SIRTF Observatory following its recovery from the missions cancellation in 1991 the IRS became smaller and much, much simpler. The only aspect of the instrument that increased from the original design was the pixel count of the detectors.

SIRTF↗

The Infrared Spectrograph on the Spitzer Space Telescope

The Infrared Spectrograph (IRS) instrument on the Spitzer Space Telescope covered the 5 to 38 micron wavelength range at low and medium spectral resolutions. The instrument was very popular during Spitzer’s 5.7 year-long cold mission. Every year it attracted the most proposals, and garnered more observing hours, of any of the science instruments. This success was the culmination of a very long development period, where the instrument design changed radically. When the instrument was first selected by NASA in 1984 it was very complicated. As part of the overall reduction of the size of the SIRTF Observatory following its recovery from the mission’s cancellation in 1991 the IRS became smaller and much, much simpler. The only aspect of the instrument that increased from the original design was the pixel count of the detectors. The new, lean, IRS based on eight axioms: (1) SIRTF is a cost-driven mission; (2) Only Boeing Si:As and Si:Sb 128x128 BIB arrays shall be used; (3) The IRS has all Aluminum housing and optics; (4) Simple optics consisting of surfaces of revolution, flat gratings, and “bolt-and-go” tolerances; (5) No moving parts; (6) Redundancy only for credible single-point failures; (7) Strive for an observing efficiency of 80%; (8) The IRS shall be capable of internal health assessment. This led to a simple, robust, but still extremely powerful final instrument composed of four distinct modules. Many of the features developed for the IRS were subsequently employed in other spacecraft and SOFIA science instrumentation. This presentation will cover the developmental history of the IRS instrument, its final design and performance, and will especially highlight the sage decisions that Jim Houck made along the way that led to its highly successful career on the Spitzer Space Telescope.

Roellig, Thomas L.↗