Search NASA⌕ Search

SEARCH · Search NASA

Results for “potable water”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Wautersia: The Contingency Water Container Bacterial Contamination Investigation

The Orbiter delivers water to the International Space Station (ISS) in Contingency Water Containers (CWCs) on each flight to the ISS. These CWCs are routinely sampled during each mission to verify the quality of the delivered water. Of the 5 samples returned on STS118/ 13A.1 in August 2007, two exhibited microbial growth exceeding potable water acceptability limits and historical data by orders of magnitude . The microbe was identified as Wautersia species and an investigation was launched to find the source of the contamination. Since then, samples collected on subsequent flights indicated additional CWCs had the same bacteria, as well as several on-orbit systems. An investigation was launched to try to find and address the source of the bacterial contamination. This paper will discuss how Wautersia was found, what Wautersia is, the investigation, and resolution.

Shkedi, Brienne↗

Development of water quality standards criteria

Qualitative and semiquantitative analyses were made of volatile organic compounds in water supplies collected at various stages of processing in the space station prototype vacuum compression distillation unit to evaluate the process and the product water. Additional evaluation was made of specific ingredients required to adequately enhance the taste of the reclaimed water. A concept for the in-flight addition of these ingredients was developed. Revisions to previously recommended potable water criteria and specifications are included.

Source record↗

Hollow-Fiber Spacesuit Water Membrane Evaporator

The hollow-fiber spacesuit water membrane evaporator (HoFi SWME) is being developed to perform the thermal control function for advanced spacesuits and spacecraft to take advantage of recent advances in micropore membrane technology in providing a robust, heat-rejection device that is less sensitive to contamination than is the sublimator. After recent contamination tests, a commercial-off-the-shelf (COTS) micro porous hollow-fiber membrane was selected for prototype development as the most suitable candidate among commercial hollow-fiber evaporator alternatives. An innovative design that grouped the fiber layers into stacks, which were separated by small spaces and packaged into a cylindrical shape, was developed into a full-scale prototype for the spacesuit application. Vacuum chamber testing has been performed to characterize heat rejection as a function of inlet water temperature and water vapor back-pressure, and to show contamination resistance to the constituents expected to be found in potable water produced by the wastewater reclamation distillation processes. Other tests showed tolerance to freezing and suitability to reject heat in a Mars pressure environment. In summary, HoFi SWME is a lightweight, compact evaporator for heat rejection in the spacesuit that is robust, contamination- insensitive, freeze-tolerant, and able to reject the required heat of spacewalks in microgravity, lunar, and Martian environments. The HoFi is packaged to reject 810 W of heat through 800 hours of use in a vacuum environment, and 370 W in a Mars environment. The device also eliminates free gas and dissolved gas from the coolant loop.

Bue, Grant↗

Iodine generator for reclaimed water purification

The system disclosed is for controlling the iodine level in a water supply in a spacecraft. It includes an iodine accumulator which stores crystalline iodine, an electrochemical valve to control the input of iodine to the drinking water and an iodine dispenser. A pump dispenses fluid through the iodine dispenser and an iodine sensor to a potable water tank storage. The iodine sensor electronically detects the iodine level in the water, and through electronic means, produces a correction current control. The correction current control operates the electro-chemical iodine valve to release iodine from the iodine accumulator into the iodine dispenser.

Wynveen, R. A.↗

Continuous-Flow System Produces Medical-Grade Water

A continuous-flow system utilizes microwave heating to sterilize water and to thermally inactivate endotoxins produced in the sterilization process. The system is designed for use in converting potable water to medical-grade water. Systems like this one could be used for efficient, small-scale production of medical- grade water in laboratories, clinics, and hospitals. This system could be adapted to use in selective sterilization of connections in ultra-pure-water-producing equipment and other equipment into which intrusion by microorganisms cannot be tolerated. Lightweight, port - able systems based on the design of this system could be rapidly deployed to remote locations (e.g., military field hospitals) or in response to emergencies in which the normal infrastructure for providing medical-grade water is disrupted. Larger systems based on the design of this system could be useful for industrial production of medical-grade water. The basic microwave-heating principle of this system is the same as that of a microwave oven: An item to be heated, made of a lossy dielectric material (in this case, flowing water) is irradiated with microwaves in a multimode microwave cavity. The heating is rapid and efficient because it results from absorption of microwave power throughout the volume of the lossy dielectric material. In this system, a copper tube having a length of 49.5 cm and a diameter of 2.25 cm serves as both the microwave cavity and the sterilization chamber. Microwave power is fed via a coaxial cable to an antenna mounted inside the tube at mid-length (see figure). Efficient power transfer occurs due to the shift in wavelength associated with the high permittivity of water combined with the strong coupling of 2.45-GHz microwaves with rotational-vibrational transitions of the dipolar water molecule.

Akse, James R.↗

Assessment of the Vapor Phase Catalytic Ammonia Removal (VPCAR) Technology at the MSFC ECLS Test Facility

The Vapor Phase Catalytic Ammonia. Removal (VPCAR) technology has been previously discussed as a viable option for. the Exploration Water Recovery System. This technology integrates a phase change process with catalytic oxidation in the vapor phase to produce potable water from exploration mission wastewaters. A developmental prototype VPCAR was designed, built and tested under funding provided by a National Research. Announcement (NRA) project. The core technology, a Wiped Film Rotating Device (WFRD) was provided by Water Reuse Technologies under the NRA, whereas Hamilton Sundstrand Space Systems International performed the hardware integration and acceptance test. of the system. Personnel at the-Ames Research Center performed initial systems test of the VPCAR using ersatz solutions. To assess the viability of this hardware for Exploration. Life Support (ELS) applications, the hardware has been modified and tested at the MSFC ECLS Test facility. This paper summarizes the hardware modifications and test results and provides an assessment of this technology for the ELS application.

Tomes, Kristin↗

The Impact of Apollo-Era Microbiology on Human Space Flight

The microbiota of crewmembers and the spacecraft environment contributes significant risk to crew health during space flight missions. NASA reduces microbial risk with various mitigation methods that originated during the Apollo Program and continued to evolve through subsequent programs: Skylab, Shuttle, and International Space Station (ISS). A quarantine of the crew and lunar surface samples, within the Lunar Receiving Laboratory following return from the Moon, was used to prevent contamination with unknown extraterrestrial organisms. The quarantine durations for the crew and lunar samples were 21 days and 50 days, respectively. A series of infections among Apollo crewmembers resulted in a quarantine before launch to limit exposure to infectious organisms. This Health Stabilization Program isolated the crew for 21 days before flight and was effective in reducing crew illness. After the program developed water recovery hardware for Apollo spacecraft, the 1967 National Academy of Science Space Science Board recommended the monitoring of potable water. NASA implemented acceptability limits of 10 colony forming units (CFU) per mL and the absence of viable E. coli, anaerobes, yeasts, and molds in three separate 150 mL aliquots. Microbiological investigations of the crew and spacecraft environment were conducted during the Apollo program, including the Apollo-Soyuz Test Project and Skylab. Subsequent space programs implemented microbial screening of the crew for pathogens and acceptability limits on spacecraft surfaces and air. Microbiology risk mitigation methods have evolved since the Apollo program. NASA cancelled the quarantine of the crew after return from the lunar surface, reduced the duration of the Health Stabilization Program; and implemented acceptability limits for spacecraft surfaces and air. While microbial risks were not a main focus of the early Mercury and Gemini programs, the extended duration of Apollo flights resulted in the increased scrutiny of impact of the space flight environment on crew health. The lessons learned during that era of space flight continue to impact microbiology risk mitigation in space programs today.

Elliott, T. F↗

Health significance and occurrence of injured bacteria in drinking water

Enteropathogenic and indicator bacteria become injured in drinking water with exposure to sublethal levels of various biological, chemical and physical factors. One manifestation of this injury is the inability to grow and form colonies on selective media containing surfactants. The resulting underestimation of indicator bacteria can lead to a false estimation of water potability. m-T7 medium was developed specifically for the recovery of injured coliforms (both "total" and fecal) in drinking water. The m-T7 method was used to survey operating drinking water treatment and distribution systems for the presence of injured coliforms that were undetected with currently used media. The mean recovery with m-Endo LES medium was less than 1/100 ml while it ranged between 6 and 68/100ml with m-T7 agar. The majority of samples giving positive results with m-T7 medium yielded no detectable coliforms with m-Endo LES agar. Over 95% of the coliform bacteria in these samples were injured. Laboratory experiments were also done to ascribe the virulence of injured waterborne pathogens. Enteropathogens including Salmonella typhimurium, Yersinia enterocolitica and Shigella spp. required up to 20 times the chlorine levels to produce the same injury in enterotoxigenic Escherichia coli (ETEC) and nonpathogenic coliforms. Similar results were seen with Y. enterocolitica exposed to copper. The recovery of ETEC was followed by delayed enterotoxin production, both in vitro and in the gut of experimental animals. This indicates that injured waterborne enteropathogenic bacteria can be virulent.

NASA Discipline Number 13-40↗

Soyuz 22 Return Samples: Assessment of Air Quality Aboard the International Space Station

Three mini-grab sample containers (m-GSCs) were returned aboard Soyuz 22 because of concerns that new air pollutants were present in the air and these were getting into the water recovery system. The Total Organic Carbon Analyzer had been giving increasing readings of total organic carbon (TOC) in the potable water, and it was postulated that an increased load into the system was responsible. The toxicological assessment of 3 m-GSCs from the ISS is shown in Table 1. The recoveries of the 3 standards (as listed above) from the GSCs averaged 103, 95 and 76%, respectively. Recovery from formaldehyde control badges were 90 and 91%.

Jams, John T.↗

Soyuz 23 Return Samples: Assessment of Air Quality Aboard the International Space Station

Six mini-grab sample containers (m-GSCs) were returned aboard Soyuz 23 because of concerns that new air pollutants had been present in the air and these were getting into the water recovery system. The Total Organic Carbon Analyzer had been giving increasing readings of total organic carbon (TOC) in the potable water, and it was postulated that an increased load into the system was responsible. The TOC began to decline in late October, 2010. The toxicological assessment of 6 m-GSCs from the ISS is shown in Table 1. The recoveries of 13C-acetone, fluorobenzene, and chlorobenzene from the GSCs averaged 73, 82, and 59%, respectively. We are working to understand the sub-optimal recovery of chlorobenzene.

James, John T.↗

Method Development for In Situ Microbiome Profiling of the Water Recovery System’s Wastewater Tank Onboard the International Space Station

A distinctive microbial community has inhabited the wastewater tank within the International Space Station Water Recovery System (WRS) for over 14 years and experienced the stressors associated with the microgravity environment. The WRS generates potable water for the crew from urine distillate, humidity condensate, Sabatier product water, and the occasional off-loading of ground-supplied water. The reservoir for these products, the wastewater tank, does not have a means of microbial control. While samples are occasionally collected for analysis, the time between sample collection and the return to Earth, as well as the lack of preservation, results in a skewed depiction of the microbiome. Routinely observed from these returned samples are high counts (105 – 106 colony forming units per mL) and two prevailing genera, Burkholderia and Ralstonia. The wastewater tank likely contains a more diverse microbiome, as a higher diversity of bacteria and fungus has been noted upstream and downstream of the tank. To characterize the microbial profile of the tank, analysis needs to occur at the time of sample collection. Toward this goal, a method for in situ analysis based on nanopore sequencing was developed. The filter-to-sequencer method evolved from previous work that has been validated onboard the ISS (BEST payload and the BioMole Crew Health Care Systems Facility). The method, including filtration, DNA extraction, purification, amplification, library preparation, and nanopore sequencing will be described. Additionally, data collected with this method from both ISS and terrestrial samples will be detailed. The consumables needed to support in situ analysis of the tank are set to the launch to the ISS in the spring of 2023. This investigation will allow for the first accurate characterization of the microbiome of the tank providing insight for crew health, planetary protection, and has the potential to enable engineering controls for future space station water systems.

Sarah Stahl-Rommel↗

Water system microbial check valve development

A residual iodine microbial check valve (RIMCV) assembly was developed and tested. The assembly is designed to be used in the space shuttle potable water system. The RIMCV is based on an anion exchange resin that is supersaturated with an iodine solution. This system causes a residual to be present in the effluent water which provides continuing bactericidal action. A flight prototype design was finalized and five units were manufactured and delivered.

Colombo, G. V.↗

Microbial distribution in the Environmental Control and Life Support System water recovery test conducted at NASA, MSFC

NASA/MSFC is developing a physical/chemical treatment system to reclaim wastewater for reuse on Space Station Freedom (SSF). Integrated testing of hygiene and potable water subsystems assessed the capability to reclaim water to SSF specifications. The test was conducted from May through July 1990 with a total of 47 days of system test operation. Water samples were analyzed using standard cultural methods employing membrane filtration and spread plate techniques and epifluorescence microscopy. Fatty acid methyl ester and biochemical profiles were used for microbial identification. Analysis of waste and product water produced by the subsystems demonstrated the effective reduction of viable microbial populations greater than 8.0E + 06 colony forming units (CFU) per 100 mL to an average of 5 CFU/100 mL prior to distribution into storage tanks.

Gauthier, J. J.↗

Upgrading and extended testing of the MSC integrated water and waste management hardware

The results are presented of upgrading and testing an integrated water and waste management system, which uses the compression distillation, reverse osmosis, adsorption filtration and ion-exchange processes to recover potable water from urine, flush water and used wash water. Also included is the development of techniques for extending the useful biological life of biological filters, activated carbon filters and ion-exchange resins to at least 30 days, and presterilizing ion-exchange resins so that sterile water can be recovered from waste water. A wide variety of reverse osmosos materials, surfactants and germicides were experimentally evaluated to determine the best combination for a wash water subsystem. Full-scale module tests with real wash water demonstrated that surface fouling is a major problem.

Bambenek, R. A.↗

Organics in water contamination analyzer, phase 1

The requirements which would result in identifying the components of an automatic analytical system for the analysis of specific organic compounds in the space station potable water supply are defined. The gas chromatographic system for such an analysis is limited to commercially available off-the-shelf hardware and includes the sample inlet, an ionization detector, capillary columns as well as computerized compound identification. The sampling system will be a special variation of the purge and trap Tenax mode using six-port valves and a 500 microliter water sample. Capillary columns used for the separating of contaminants will be bonded phase fused silica with a silicone stationary phase. Two detectors can be used: photoionization and far ultraviolet, since they are sensitive and compatible with capillary columns. A computer system evaluation and program with the principle of compound identification based on the retention index is presented.

Source record↗

Iodine sorption study on the proposed use of Viton A in a shuttle galley water accumulator

The installation of a Viton A accumulator in the Shuttle galley has been proposed to prevent overpressurization of the hot water supply system. A laboratory study has been conducted to determine if there would be any interaction between the Viton A material and the iodine used to disinfect the water. Coupons of Viton A were exposed for 24 hours to aqueous iodine solutions similar in quality to the Shuttle's potable water. Changes in the iodine residual were monitored to determine the rate of iodine sorption by the coupon. Total organic carbon (TOC) was monitored to determine the rate of desorption of organic materials from the Viton A. The same coupons were then soaked in reagent-grade water for 24 hours, and iodine was monitored to determine the rate of iodine desorption. The coupons were again exposed to iodine solutions for 24 hours and iodine and TOC were monitored. No significant change in the iodine sorption rate was detected between the first and second exposures. A triangle taste test indicated at a 1 percent confidence level that the water exposed to Viton A had a different taste which was less acceptable to the panelists.

Gibbons, Randall E.↗