Search NASA⌕ Search

SEARCH · Search NASA

Results for “power cable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Application of Principal Component Analysis for the Monitoring of the Aging Process of Nuclear Electrical Cable Insulation

To ensure the safe operation of nuclear power plants (NPPs), it is critical to understand how NPP electrical cable insulation will degrade under different service environments. In this study, various nondestructive examination methods were selected to evaluate degradation of electrical cable insulation after aging. Elongation at break, indenter modulus, relaxation constant, mass change, total color difference, and carbonyl index were collected stepwise on cross-linked polyethylene (XLPE) cable insulations after predetermined exposure intervals. Three different insulation aging scenarios were investigated: 1) simultaneous irradiation and heating at 150°C, 2) heating at 150°C followed by corresponding times of irradiation at ambient temperature, and 3) irradiation at ambient temperature followed by heating at 150°C for the same duration. A constant dose rate of 300 Gy/hr was selected with a total gamma irradiation absorbed dose up to 320 kGy. To gain insight into the long-term performance of NPP electrical cable insulation, principal component analysis (PCA), a data-driven approach, was utilized to identify key indicators of cable insulation degradation. By reducing the dimensionality of the data while retaining degradation information, PCA was used to highlight the changes in the measured properties under gamma irradiation according to total absorbed dose and the different aging scenarios.

Li, Donghui↗

Reusable Hot-Wire Cable Cutter

During the early development stage of balloon deployment systems for missions, nichrome wire cable cutters were often used in place of pyro-actuated cutters. Typically, a nichrome wire is wrapped around a bundle of polymer cables with a low melting point and connected to a relay-actuated electric circuit. The heat from the nichrome reduces the strength of the cable bundle, which quickly breaks under a mechanical load and can thus be used as a release mechanism for a deployment system. However, the use of hand-made heated nichrome wire for cutters is not very reliable. Often, the wrapped nichrome wire does not cut through the cable because it either pulls away from its power source or does not stay in contact with the cable being cut. Because nichrome is not readily soldered to copper wire, unreliable mechanical crimps are often made to connect the nichrome to an electric circuit. A self-contained device that is reusable and reliable was developed to sever cables for device release or deployment. The nichrome wire in this new device is housed within an enclosure to prevent it from being damaged by handling. The electric power leads are internally connected within the unit to the nichrome wire using a screw terminal connection. A bayonet plug, a quick and secure method of connecting the cutter to the power source, is used to connect the cutter to the power leads similar to those used in pyro-cutter devices. A small ceramic tube [0.25-in. wide 0.5-in. long (.6.4-mm wide 13-mm long)] houses a spiraled nichrome wire that is heated when a cable release action is required. The wire is formed into a spiral coil by wrapping it around a mandrel. It is then laid inside the ceramic tube so that it fits closely to the inner surface of the tube. The ceramic tube provides some thermal and electrical insulation so that most of the heat generated by the wire is directed toward the cable bundle in the center of the spiral. The ceramic tube is cemented into an aluminum block, which holds it in position. The leads of the nichrome wire are attached to screw terminals that connect them to power leads. A bayonet plug mounted at the bottom of the rectangular block connects the power leads to a relay circuit. A thin aluminum shell encloses the entire structure, leaving access points to attach to the bayonet plug and to feed a cable into the cylinder. The access holes for the deployment cable are a smaller diameter than the nichrome coil to prevent the cable from coming in direct contact with the nichrome when loaded. It uses the same general method of severing a cable with a heated wire as was used previously, but implements it in such a way that it is more reliable and less prone to failure. It creates a mechanism to create repeatability that was nonexistent in the previous method.

Pauken, Michael T.↗

Evolution of integrated panel structural design and interfaces for PV power plants

The evolution of integrated photovoltaic (PV) panel design at ARCO Solar is discussed. Historically, framed PV modules of about 1 x 4-ft size were individually mounted in the field on fixed support structures and interconnected electrically with cables to build higher-power arrays. When ARCO Solar saw the opportunity in 1982 to marry its PV modules with state-of-the-art heliostat trackers developed by ARCO Power Systems, it became obvious that mounting individual modules was impractical. For this project, the framed modules were factory-assembled into panels and interconnected with cables before being mounted on the trackers. Since then, ARCO Solar made considerable progress and gained substantial experience in the design and fabrication of large PV panels. Constraints and criteria considered in these design activities included static and dynamic loads; assembly and transportation equipment and logistics, structural and electrical interfaces, and safety and grounding concerns.

Arnett, J. C.↗

Non-Rocket Missile Rope Launcher

The method, installation, and estimation for delivering payload and missiles into outer space are presented. This method uses, in general, the engines and straight or closed-loop cables disposed on a planet surface. The installation consists of a space apparatus, power drive stations located along trajectory of the apparatus, the cables connected to the apparatus and to the power stations, a system for suspending the cable, and disconnected device. The drive stations accelerate the apparatus up to hypersonic speed. The estimations and computations show the possibility of making these projects a reality in a short period of time (see attached project: launcher for missiles and loads). The launch will be very cheap $1-$2 per LB. We need only light strong cable, which can be made from artificial fibers, whiskers, nanotubes, which exist in industry and scientific laboratories.

Bolonkin, Alexander↗

Application of Cable Condition Monitoring Technologies to Assess Age-Related Degradation of Industrial Cables Installed in Harsh Environments

The aging of electrical cables has been the subject of substantial research and development (R&D) projects performed by national and international laboratories, universities, and private organizations for many years. This R&D was conducted to develop guidance, equipment, and techniques to support aging management of in-service cables in industrial facilities such as nuclear power plants, research reactors, waste facilities, and fuel fabrication plants. Through these research efforts, condition monitoring technologies have been developed that can determine the severity of age-related degradation that occurs in industrial cables and insulation polymers during service. This paper summarizes the results of aging assessments that were performed for cables installed in two U.S. nuclear power plants, one a pressurized water reactor and one a boiling water reactor. These cables had been in service for over 40 years and during plant operation were exposed to harsh environmental conditions including elevated temperatures and radiation. For these assessments, a comprehensive series of measurements was performed to assess the aged condition of the cables. These cables came from different manufacturers, were manufactured in different years, and were constructed with a variety of jacket and insulation polymers including chloro-sulfonated polyethylene (CSPE), cross-linked polyethylene (XLPE)/cross-linked polyolefin (XLPO), neoprene, and ethylene propylene rubber (EPR). The goal of these assessments was to determine the current aged condition of the cable polymers and provide an estimate of how long the cable insulation materials could remain exposed to their in-service environmental conditions before reaching their end-of-life condition. Both nuclear power plants have received license renewals to extend their operation from 40 to 60 years, and the utilities need objective evidence to show that critical components such as cables will be able to function safely and reliably during the extended operating period. Furthermore, the results of these assessments showed that the cables exhibited different aged conditions depending on the type of polymers they were constructed with and the environment they were exposed to during service. Some of the cables and insulation polymers showed signs of significant age-related degradation and were estimated to have approximately 5 years of remaining service life. Other cables exhibited no signs of significant age-related degradation and were estimated to have 50 years or more of remaining service life. Using the results of these cable aging assessments, plant personnel were able to (1) determine the overall aged condition of cables and insulation polymers using objective test results, (2) identify aged or degraded cables before they caused operability issues, and (3) avoid unnecessary and costly replacement of cables that can continue to operate safely and reliably.

36 MATERIALS SCIENCE↗

Continuous-Flow System Produces Medical-Grade Water

A continuous-flow system utilizes microwave heating to sterilize water and to thermally inactivate endotoxins produced in the sterilization process. The system is designed for use in converting potable water to medical-grade water. Systems like this one could be used for efficient, small-scale production of medical- grade water in laboratories, clinics, and hospitals. This system could be adapted to use in selective sterilization of connections in ultra-pure-water-producing equipment and other equipment into which intrusion by microorganisms cannot be tolerated. Lightweight, port - able systems based on the design of this system could be rapidly deployed to remote locations (e.g., military field hospitals) or in response to emergencies in which the normal infrastructure for providing medical-grade water is disrupted. Larger systems based on the design of this system could be useful for industrial production of medical-grade water. The basic microwave-heating principle of this system is the same as that of a microwave oven: An item to be heated, made of a lossy dielectric material (in this case, flowing water) is irradiated with microwaves in a multimode microwave cavity. The heating is rapid and efficient because it results from absorption of microwave power throughout the volume of the lossy dielectric material. In this system, a copper tube having a length of 49.5 cm and a diameter of 2.25 cm serves as both the microwave cavity and the sterilization chamber. Microwave power is fed via a coaxial cable to an antenna mounted inside the tube at mid-length (see figure). Efficient power transfer occurs due to the shift in wavelength associated with the high permittivity of water combined with the strong coupling of 2.45-GHz microwaves with rotational-vibrational transitions of the dipolar water molecule.

Akse, James R.↗

Development of a Field-Deployable Microphone Phased Array for Airframe Noise Flyover Measurements

This technical memorandum describes in detail the construction and use of a large channel-count, field-deployable microphone phased array designed for airframe noise flyover measurements for a range of aircraft types and scales. The array incorporated 185 hardened, weather-resistant sensors suitable for outdoor use. A custom 4-mA current loop receiver circuit with temperature compensation was developed to power the sensors over extended cable lengths with minimal loss of signal-to-noise. Extensive calibrations and performance testing of the sensors were conducted to verify the design specifications. A compact data system combining sensor power, signal conditioning, and digitization was assembled for use with the array. Complementing the data system was a robust analysis system capable of near real-time presentation of beamformed and deconvolved contour plots and integrated spectra obtained from data acquired during flyover passes of the array. Additional instrumentation systems needed to process the array data were also developed, including a commercial 10-meter weather station comprised of a sonic anemometer, aspirated temperature/humidity probe and pressure sensor. Unique methods for assessing the health of the array in-situ were developed and demonstrated. A detailed mock-up of the instrumentation suite (phased array, weather station, and data processor) was performed in the NASA Langley Acoustic Development Laboratory in 2014 to vet the system performance. Issues with the sensors and electronics were identified during the mock-up and subsequently corrected. The array was then deployed for preliminary field testing at Fort A.P. Hill in Virginia in 2015 followed by the array being utilized in three separate full-scale airframe noise test campaigns at Edwards Air Force Base in California from 2016 to 2018 where the system was used to characterize the noise generated by both baseline and treated flaps and main landing gear on a commercial transport-sized vehicle.

Phased Array↗

Design and Fabrication of the Mu2e Cryogenic Distribution System

The muon-to-electron conversion (Mu2e) experiment at Fermilab will be used to search for the charged lepton flavor-violating conversion of muons to electrons in the field of an atomic nucleus. The Mu2e experiment is currently in the design and construction stage and is expected to begin operations in 2022. The Mu2e experiment uses four large superconducting solenoid magnets including a Production Solenoid (PS), an Upstream and Downstream Transport Solenoid (TSu and TSd) and a Detector Solenoid (DS). This paper will focus on the cryogenic distribution system for these four solenoid magnets. Liquid helium will be supplied from two re-purposed Tevatron satellite refrigerators. A large cryogenic distribution box (DB) is located in the Mu2e building to distribute the required cryogens to each of the four solenoid magnets. Each solenoid magnet will have a dedicated transfer line and cryogenic feed box (FB). The solenoid magnets each require two liquid helium circuits and two liquid nitrogen circuits. The most unique feature about this cryogenic system is that the assemblies for the start of the superconducting portion of the power leads are mounted in feed boxes that are in the range of 23 m to 31 m away from the solenoid magnets. The cryogenic feed boxes are located remotely to provide protection from radiation damage and high magnetic fields. The power leads are NbTi superconducting cable stabilized with high conductivity aluminum. The 6061-T6 aluminum grade was selected for the transfer line piping so that the piping would thermally contract at the same rate as the power lead. A major concern for this transfer line is that a small helium leak could create an electric discharge arc due to the Paschen effect. This paper includes a description of the design features and testing done to ensure that the power leads are protected from the Paschen effect while still being adequately cooled to liquid helium temperatures.

43 PARTICLE ACCELERATORS↗

SSTDR and FDR Detection of Un-Energized and Energized Cable Anomalies Including Thermal Degradation Using Machine Learning

Historically, cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages. A related technology that has found some acceptance in the aircraft and rail industry is spread spectrum time domain reflectometry (SSTDR). This technology has been implemented with a custom commercial instrument by LiveWire Innovation that is designed to operate on live cables up to 1000 volts and with a bandwidth of 48 MHz. Initial evaluation by the Pacific Northwest National Laboratory (PNNL) of the Live Wire system indicated that a broader bandwidth (BW) SSTDR may be better for many kinds of flaws. This led PNNL to develop an SSTDR laboratory instrument suitable for tests up to 500 MHz bandwidth. Testing on energized cables is also desirable for online monitoring systems so an inductive clamshell coupler was developed that allows energized cables to be tested up to at least 5 kV and likely higher voltage levels. Dielectric spectroscopy and tan delta testing plus various laboratory destructive tests were included in this data acquisition campaign directed to feed a machine learning (ML) study. With these kinds of developments, online energized cable tests may be possible with industrial adoption of such hardware advances but it will be completely impractical to have highly skilled data analysts continually examine these complex signals for indications of damage or compromised conditions. If online testing is to be implemented in new test hardware, it must be accompanied by software that can interpret the signals and alert plant operators of changing or degraded conditions. The thermally aged, shielded cable investigated here was separately treated for ML analysis. Visual analysis of electrical data showed generally increasing peaks where the cable entered and exited the oven. These peaks were not exactly aligned with expected locations, but these differences were attributed to velocity of propagation calibration errors. Only supervised ML was applied to the thermally aged data as this data was only available shortly before the committed publication date of this report. The supervised ML was structured to divide the 0 to 70-day responses as ‘normal’ from 0 to 35 days or ‘anomalous’ from 36 to 70 days, based on cable tensile elongation at break (EAB) insulation characterization. Using 80% of the data for training and 20% for testing, the supervised ML predicted normal versus anomalous was 70% accurate. Important conclusions include: • Accuracy to predict the presence of cable damage is improved from the 2023 effort by more training data. Weighted accuracies for comparisons among the instruments ranged from 67 to 89 % for unsupervised ML and 71 to 99% for supervised ML. • Based on the synthetic data tests, the unsupervised models are more generalizable to unseen anomalies. The Multi-Layer Perceptron classifier (MLP) model reported as high as 99.7% accuracy on the test data, but this dropped to 58.3% when tested on the synthetic data. In contrast, the unsupervised Pointwise model only achieved 89.7% accuracy on the experimental data but reported 78.3% accuracy on the synthetic data. • The best anomaly indicators are higher frequency (400 MHz BW) FDR data. Other tests may be interesting but for this study, this was the best predicter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of the NEPTUNE power system

The NEPTUNE power system is required to make available at each location the largest amount of power possible, using conventional submarine telecommunications cable.

NEPTUNE power underwater converter↗

Development and Calibration of a Field-Deployable Microphone Phased Array for Propulsion and Airframe Noise Flyover Measurements

A new aeroacoustic measurement capability has been developed consisting of a large channelcount, field-deployable microphone phased array suitable for airframe noise flyover measurements for a range of aircraft types and scales. The array incorporates up to 185 hardened, weather-resistant sensors suitable for outdoor use. A custom 4-mA current loop receiver circuit with temperature compensation was developed to power the sensors over extended cable lengths with minimal degradation of the signal to noise ratio and frequency response. Extensive laboratory calibrations and environmental testing of the sensors were conducted to verify the design's performance specifications. A compact data system combining sensor power, signal conditioning, and digitization was assembled for use with the array. Complementing the data system is a robust analysis system capable of near real-time presentation of beamformed and deconvolved contour plots and integrated spectra obtained from array data acquired during flyover passes. Additional instrumentation systems needed to process the array data were also assembled. These include a commercial weather station and a video monitoring / recording system. A detailed mock-up of the instrumentation suite (phased array, weather station, and data processor) was performed in the NASA Langley Acoustic Development Laboratory to vet the system performance. The first deployment of the system occurred at Finnegan Airfield at Fort A.P. Hill where the array was utilized to measure the vehicle noise from a number of sUAS (small Unmanned Aerial System) aircraft. A unique in-situ calibration method for the array microphones using a hovering aerial sound source was attempted for the first time during the deployment.

Humphreys, William M., Jr.↗

Cable Tester Box

Cables are very important electrical devices that carry power and signals across multiple instruments. Any fault in a cable can easily result in a catastrophic outcome. Therefore, verifying that all cables are built to spec is a very important part of Electrical Integration Procedures. Currently, there are two methods used in lab for verifying cable connectivity. (1) Using a Break-Out Box and an ohmmeter this method is time-consuming but effective for custom cables and (2) Commercial Automated Cable Tester Boxes this method is fast, but to test custom cables often requires pre-programmed configuration files, and cables used on spacecraft are often uniquely designed for specific purposes. The idea is to develop a semi-automatic continuity tester that reduces human effort in cable testing, speeds up the electrical integration process, and ensures system safety. The JPL-Cable Tester Box is developed to check every single possible electrical connection in a cable in parallel. This system indicates connectivity through LED (light emitting diode) circuits. Users can choose to test any pin/shell (test node) with a single push of a button, and any other nodes that are shorted to the test node, even if they are in the same connector, will light up with the test node. The JPL-Cable Tester Boxes offers the following advantages: 1. Easy to use: The architecture is simple enough that it only takes 5 minutes for anyone to learn how operate the Cable Tester Box. No pre-programming and calibration are required, since this box only checks continuity. 2. Fast: The cable tester box checks all the possible electrical connections in parallel at a push of a button. If a cable normally takes half an hour to test, using the Cable Tester Box will improve the speed to as little as 60 seconds to complete. 3. Versatile: Multiple cable tester boxes can be used together. As long as all the boxes share the same electrical potential, any number of connectors can be tested together.

Lee, Jason H.↗

Testing of a Line Driver With Configurable Pre-Emphasis on Lossy Transmission Lines

Rare-event physics experiments such as the Deep Underground Neutrino Experiment (DUNE) or the next Enriched Xenon Observatory (nEXO) experiment search for rare, low-energy events, detected by sensitive detectors immersed in a cryogenic noble liquid (e.g., liquid argon or xenon). Readout electronics used within such detectors must consume minimal power while operating reliably in cryogenic environments. Furthermore, in the case of nEXO, maximizing the radiopurity of the environment is vital to minimize background noise, thus placing strict limits on the volume of dielectric materials, leading to high-loss data cables spanning distances up to 12 m. Such cables cause high attenuation and intersymbol interference (ISI), resulting in a high bit-error rate (BER). These issues were addressed by developing an integrated line driver with configurable pre-emphasis in a 65-nm CMOS process. The pre-emphasis parameters can be programmed to minimize BER for specific cables and data rates under power constraints. Here, the driver was tested at both room and cryogenic temperatures. In both cases, the output BER was found to be strongly correlated with the pre-emphasis settings. Furthermore, analysis and simulation showed that adapting the pre-emphasis settings based on the incoming bit sequence can further improve performance with minimal changes to the current solution.

47 OTHER INSTRUMENTATION↗

Regenerative Performance of the NASA Symmetrical Solid Oxide Fuel Cell Design

The NASA Glenn Research Center is developing both a novel cell design (BSC) and a novel ceramic fabrication technique to produce fuel cells predicted to exceed a specific power density of 1.0 kW/kg. The NASA Glenn cell design has taken a completely different approach among planar designs by removing the metal interconnect and returning to the use of a thin, doped LaCrO3 interconnect. The cell is structurally symmetrical. Both electrodes support the thin electrolyte and contain micro-channels for gas flow-- a geometry referred to as a bi-electrode supported cell or BSC. The cell characteristics have been demonstrated under both SOFC and SOE conditions. Electrolysis tests verify that this cell design operates at very high electrochemical voltage efficiencies (EVE) and high H2O conversion percentages, even at the low flow rates predicted for closed loop systems encountered in unmanned aerial vehicle (UAV) applications. For UAVs the volume, weight and the efficiency are critical as they determine the size of the water tank, the solar panel size, and other system requirements. For UAVs, regenerative solid oxide fuel cell stacks (RSOFC) use solar panels during daylight to generate power for electrolysis and then operate in fuel cell mode during the night to power the UAV and electronics. Recent studies, performed by NASA for a more electric commercial aircraft, evaluated SOFCs for auxiliary power units (APUs). System studies were also conducted for regenerative RSOFC systems. One common requirement for aerospace SOFCs and RSOFCs, determined independently in each application study, was the need for high specific power density and volume density, on the order of 1.0 kW/kg and greater than 1.0 kW/L. Until recently the best reported performance for SOFCs was 0.2 kW/kg or less for stacks. NASA Glenn is working to prototype the light weight, low volume BSC design for such high specific power aerospace applications.

Cable, Thomas L.↗

Inverted Geometry Ceramic Insulators in High Voltage DC Electron Guns for Accelerators

A direct current (dc) high voltage photo-emission electron gun operating at 130 kV is utilized at the Jefferson Lab (JLab) Continuous Electron Beam Accelerator Facility to generate spin-polarized electrons for nuclear physics experiments. Over the past decade, JLab has tested and implemented inverted-geometry ceramic insulators in photoguns, connecting the cathode electrode in vacuum to the high voltage power supply using commercial high voltage cables. This contribution reports on tests performed up to 375 kV dc, implementation of inverted insulators in a 300 kV dc photogun generating magnetized electron beams, and describes plans to develop a reliable insulator-cable connector for applying 500 kV dc to a future polarized beam photogun operating reliably and without field emission at 350 kV.

Hernandez-Garcia, C.↗

Spread spectrum time domain reflectometry (SSTDR) and frequency domain reflectometry (FDR) cable inspection using machine learning

Cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, justification for continued cable use must shift to a condition-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. The Pacific Northwest National Laboratory (PNNL) Accelerated and Real Time Experimental Nodal Analysis (ARENA) cable motor test bed was used to test the response of a commercial spread spectrum time domain reflectometry (SSTDR) system, a laboratory instrument software-controlled SSTDR, and a vector network analyzer-based frequency domain reflectometry (FDR) system to various cable anomalies. The three instrument systems were able to interrogate cables over a range of frequency bandwidths that can be helpful for human data analysis. Data were subjected to supervised and unsupervised machine learning (ML) analyses to distinguish normal undamaged cable responses from anomalous cable responses. Both supervised and unsupervised ML approaches produced encouraging results with an undamaged/anomalous prediction accuracy from 0.69% to 0.87%. Recommendations for further development and field implementation include increased and more balanced sample sets particularly including more training data.

SSTDR, FDR, Reflectometry, Machine Learning, ARENA↗

Description of a 20 Kilohertz power distribution system

A single phase, 440 VRMS, 20 kHz power distribution system with a regulated sinusoidal wave form is discussed. A single phase power system minimizes the wiring, sensing, and control complexities required in a multi-sourced redundantly distributed power system. The single phase addresses only the distribution link; mulitphase lower frequency inputs and outputs accommodation techniques are described. While the 440 V operating potential was initially selected for aircraft operating below 50,000 ft, this potential also appears suitable for space power systems. This voltage choice recognizes a reasonable upper limit for semiconductor ratings, yet will direct synthesis of 220 V, 3 power. A 20 kHz operating frequency was selected to be above the range of audibility, minimize the weight of reactive components, yet allow the construction of single power stages of 25 to 30 kW. The regulated sinusoidal distribution system has several advantages. With a regulated voltage, most ac/dc conversions involve rather simple transformer rectifier applications. A sinusoidal distribution system, when used in conjunction with zero crossing switching, represents a minimal source of EMI. The present state of 20 kHz power technology includes computer controls of voltage and/or frequency, low inductance cable, current limiting circuit protection, bi-directional power flow, and motor/generator operating using standard induction machines. A status update and description of each of these items and their significance is presented.

Hansen, I. G.↗

Description of a 20 kilohertz power distribution system

A single phase, 440 VRMS, 20 kHz power distribution system with a regulated sinusoidal wave form is discussed. A single phase power system minimizes the wiring, sensing, and control complexities required in a multi-sourced redundantly distributed power system. The single phase addresses only the distribution links multiphase lower frequency inputs and outputs accommodation techniques are described. While the 440 V operating potential was initially selected for aircraft operating below 50,000 ft, this potential also appears suitable for space power systems. This voltage choice recognizes a reasonable upper limit for semiconductor ratings, yet will direct synthesis of 220 V, 3 power. A 20 kHz operating frequency was selected to be above the range of audibility, minimize the weight of reactive components, yet allow the construction of single power stages of 25 to 30 kW. The regulated sinusoidal distribution system has several advantages. With a regulated voltage, most ac/dc conversions involve rather simple transformer rectifier applications. A sinusoidal distribution system, when used in conjunction with zero crossing switching, represents a minimal source of EMI. The present state of 20 kHz power technology includes computer controls of voltage and/or frequency, low inductance cable, current limiting circuit protection, bi-directional power flow, and motor/generator operating using standard induction machines. A status update and description of each of these items and their significance is presented.

Hansen, I. G.↗