Synchronous Wind: Evaluating the Grid Impact of Inverterless Grid-Forming Wind Power Plants

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators has attracted substantial attention in power systems research; however, the limited over-current capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. This paper develops the generic model of synchronous wind power generators, also known as Type-5 wind turbines, for power system integration studies. The Type-5 wind turbine interfaces with the electric grid through a synchronous generator; hence, its operation and consequent grid impacts are similar to a conventional power plant. Based on the developed model, a Type-5 wind power plant is integrated into the IEEE 14-bus test bed to evaluate its control and operation with a bulk power system. Finally, the stability properties of Type-5 wind turbine generators are compared with Type-3 wind turbines in GFM control mode through impedance characterization.

grid strength↗

Synchronous Wind: Evaluating the Grid Impact of Inverterless Grid-Forming Wind Power Plants: Preprint

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators have attracted substantial attention in power system research. However, the limited over-current capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. This paper developed the generic model of synchronous wind power generators, also known as Type-5 wind turbines, for the power system integration studies. The Type-5 wind turbine interface to the grid through a synchronous generator; hence, its operation and consequent grid impacts are similar to a conventional power plant. Based on the developed model, a Type-5 wind power plant is integrated into IEEE 14-bus testbed to evaluate its control and operation with a bulk power system. Finally, the stability properties of Type-5 wind turbine generators are compared with Type-3 wind turbines in GFM control mode through impedance characterization.

grid strength↗

Applying Quantum Computing to Simulate Power System Dynamics

Power system dynamics are generally modeled by high dimensional nonlinear differential-algebraic equations due to a large number of generators, loads, and transmission lines. Thus, its computational complexity grows exponentially with the system size. This paper demonstrates the potential use of quantum computing algorithms to model the power system dynamics. Leveraging a symbolic programming framework, we equivalently convert the power system dynamics’ differential algebraic equations (DAEs) into ordinary differential equations (ODEs), where the data of the state vector can be encoded into quantum computers via amplitude encoding. The system's nonlinearity is captured by Taylor polynomial expansion, the quantum state tensor, and Hamiltonian simulation, whereas state variables can be updated by a quantum linear equation solver. Our results show that quantum computing can simulate the dynamics of the power system with high accuracy, whereas its complexity is polynomial in the logarithm of the system dimension. Our work also illustrates the use of scientific machine learning tools for implementing scientific computing concepts, e.g., Taylor expansion, DAEs/ODEs transform, and quantum computing solver, in the field of power engineering.

Tran, Huynh↗

A 20-kW DC Oak Ridge Converter with Integrated AC & DC Sources for Grid Services and Energy Storage Systems

This paper proposes a wireless power transfer (WPT) platform with integrated energy conversion that has the capability for 1) recharging the energy storage systems (ESSs) from the grid systems, including renewable energy sources such as wind, solar, etc., 2) off grid systems recharging the ESSs from dc grid systems, 3) grid recharging of electric vehicles (EVs), and 4) off grid recharging of EVs from ESSs. The unique aspect of the method is the use of multi-interface power electronic converter for the grid and ESSs and EVs that can support a range of applications with ac / dc and dc / dc energy conversion ability in a single converter system. The key enabling technology to achieve these functionalities is Oak Ridge Converter (ORC) with polyphase coupler coil system both developed at ORNL. This new technology enables higher power density WPT systems while allowing the coils to interface from ac grid at 60 Hz frequency or dc source directly merging with 85 kHz operating frequency of switching component. The experimental results of the proposed system are presented for 20 kW output power with the system overall efficiency around 95.4% from dc source and 93% overall efficiency from ac grid achieving 9-10% current total harmonic distortion (THD) and 0.98-0.99 power factor (PF).

Asa, Erdem↗

Theoretical Analysis and Experimental Validation of Flying-Capacitor Multilevel Converters Under Short-Circuit Fault Conditions

Addressing the increasing demand for high- efficiency and high-power-density converters, the flying-capacitor multilevel converter has shown itself as a promising topology. A key advantage of this topology is the reduced voltage rating of the switches, though also makes it vulnerable to device failure during short-circuit conditions. Despite large interest in fault-tolerant operation of these converters, alongside detailed descriptions of flying capacitor balancing, little research has focused on the converter short-circuit fault analysis, which may cause a switch failure if not properly designed for. Therefore, this work presents a comprehensive model describing the large- signal short-circuit switching behavior of a general N -level flying- capacitor multilevel converter. Highly simplified models used to predict the evolution of the switch current and voltage stress during the fault are proposed, targeted at practicing engineers for conservative design guidelines. These models are used to determine the critical time for remedial action of the converter before reaching some predefined maximum conditions. A 2-to-10- level fully-configurable flying-capacitor multilevel converter and a fault circuit hardware prototype are used to experimentally perform different short-circuit tests that show a good match to the measured behavior.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Review: Indirect Optimal Control of Wave Energy Converters

Wave energy conversion has been the subject of interest in the past several years. While there are several concepts for converting wave power into electric power, the cost of the electric power harvested from ocean waves remains high. One of the main challenges, though it receives less attention, is the control of the wave energy converter (WEC). This paper presents a treatment for the WEC control problem within the context of optimal control theory. The result is systematic development for an explicit expression for a control that maximizes the harvested energy while meeting operational constraints such as the maximum device stroke and the maximum control force. The control presented here can also be adjusted to meet device design constraints such as a limitation on the amount of reactive power available from the power take-off (PTO) unit; this feature enables a control co-design for the PTO unit. Numerical simulations are presented in this paper for demonstration.

control design↗

Solving differential‐algebraic equations in power system dynamic analysis with quantum computing

Abstract Power system dynamics are generally modeled by high dimensional non‐linear differential‐algebraic equations (DAEs) given a large number of components forming the network. These DAEs' complexity can grow exponentially due to the increasing penetration of distributed energy resources, whereas their computation time becomes sensitive due to the increasing interconnection of the power grid with other energy systems. This paper demonstrates the use of quantum computing algorithms to solve DAEs for power system dynamic analysis. We leverage a symbolic programming framework to equivalently convert the power system's DAEs into ordinary differential equations (ODEs) using index reduction methods and then encode their data into qubits using amplitude encoding. The system non‐linearity is captured by Hamiltonian simulation with truncated Taylor expansion so that state variables can be updated by a quantum linear equation solver. Our results show that quantum computing can solve the power system's DAEs accurately with a computational complexity polynomial in the logarithm of the system dimension. We also illustrate the use of recent advanced tools in scientific machine learning for implementing complex computing concepts, that is, Taylor expansion, DAEs/ODEs transformation, and quantum computing solver with abstract representation for power engineering applications.

computational complexity↗

Decentralized Carrier Phase Shifting for Optimal Harmonic Minimization in Asymmetric Parallel-Connected Inverters

This paper presents a carrier phase shifting technique for minimizing the aggregate harmonics in networks of asymmetric parallel-connected inverters for distributed power generation system applications. The proposed technique is: 1) implemented in a decentralized manner, relying only on local voltage and current measurements, and 2) optimal in the sense that it minimizes a cost function representing the carrier-frequency current harmonics. The analysis indicates that the proposed optimal carrier phase shifting technique can enable order-of-magnitude reductions in harmonic power, and also universal improvements compared to symmetric carrier interleaving for asymmetric inverter networks. Moreover, compared to existing methods that require either centralized communication or information exchange between inverters to coordinate carriers, the proposed technique is completely decentralized, which provides important practical benefits for implementation, including improved robustness and reduced cost. The technique is experimentally validated on a network of three single-phase 2-kW inverters and demonstrates a 36.5% reduction in the weighted total harmonic distortion factor of the aggregate inverter current, and the ability to converge to the optimal carrier phase spacing dynamically in less than one line frequency cycle (16.7 ms) in steady state and transient operating conditions.

42 ENGINEERING↗

5-minute Wind Power Data based on WFIP2 WRF Simulation

The second Wind Forecast Improvement Project (WFIP2) was a public-private partnership funded by the U.S. Department of Energy and NOAA, aimed at enhancing the forecast skill of numerical weather prediction models for turbine-height winds in regions with complex terrain. An 18-month Weather Research and Forecasting (WRF) model simulation was conducted over the Pacific Northwest, with model outputs validated against observational data collected during WFIP2. Simulated wind speeds were used to estimate wind power generation using reV (the Renewable Energy Potential Model developed by NREL) at ten wind project sites. Two sets of results were produced: one using wind speeds extracted from the model grid cell at the project centroid, and another using wind speeds from the actual turbine locations. For each dataset, power output was calculated using both actual turbine-specific power curves and nine generic power curves to convert wind speed into power.

17 WIND ENERGY↗

Control and Grid Support Function Evaluation for a Three-Phase Back-to-Back Modular Multilevel Converter System

This paper focuses on the evaluation of advanced inverter controls for a 500kW back-to-back (B2B), silicon carbide, multilevel modular converter (MMC) used as a direct-connected medium-voltage grid intertie. A decentralized hierarchical controller architecture for the MMC system is presented, which uses the main controller to implement higher level grid interconnection functions per the IEEE 1547–2018 standards and the local controllers to execute lower level closed-loop functionality of the MMC stages. This paper presents and elaborates on the grid functionalities are elaborated and presented. The back-to-back converter system is equipped with local controllers and their corresponding functionalities are presented. Case study results for the corresponding functionalities presented show the effectiveness of the proposed architecture. To enhance the operation capabilities of the system, a parameter update scheme has been implemented and utilized in unison with the controller.

decentralized control↗

Decoupled Active and Reactive Power Control without PLL Requirement for Differential Buck Converter

This paper presents a decoupled active and reactive power control for the differential buck converter. This control does not require phase locked loop (PLL) for synchronization. Also, it achieves active and reactive power control in a simple single control loop structure. The differential buck converter has the capability to compensate the double line frequency power ripple without relying on additional hardware. Particularly, the Common Mode (CM) operation is used for active double line frequency power ripple absorption. Whereas, the Differential Mode (DM) operation is used as an active and reactive power exchanging port between the converter and the grid at the point of common coupling (PCC). The motivation behind this paper proposal are: (i) to avoid PLL induced instabilities, especially, when connecting the differential buck converter with weak grid, and (ii) direct active and reactive power control for the differential buck in a single loop control. The theoretical analyses are verified with a 5 kW converter with only 50 μF decoupling capacitor connected to a weak grid.

Khan, Ahmad↗

Data-Driven Cyber-Attack Detection for PV Farms via Time-Frequency Domain Features

The internetworking of grid-connected power electronics converters (PECs) in photovoltaic (PV) farms has inevitably expanded the cyber-attack surfaces. Here this paper presents a comprehensive study on cyber-attack detection and diagnosis for PEC-enabled PV farms via single waveform sensor to distinguish between normal conditions, open-circuit faults, short-circuit faults, and cyber-attacks. To our knowledge, this has not been attempted before. Firstly, we propose frequency-domain magnitude-based residuals to identify short-circuit faults and a time-domain mean current vector-based feature to distinguish open-circuit faults from other threats. These features can fully reflect the specific physical characteristics of PV farms during threat duration. Secondly, unlike micro phasor measurement units (µPMU) and raw electric waveform-based methods, the proposed innovative features can address novel cyber-attacks that are excluded from the training process. Thirdly, an online hardware-in-the-loop (HIL) testbed using the OPAL-RT real-time digital simulator has verified the effectiveness. The monitoring system runs in real-time while using HIL as an operational solar farm and a National Instruments (NI) data acquisition card as the electric waveform sensor at the point of coupling.

42 ENGINEERING↗

Analysis of AC-DC Converters for Grid-tied High Temperature Steam Electrolysis Systems

Grid-tied HTSE systems have the prospects to produce clean hydrogen enabling power and broad energy systems decarbonization. Most commercially available power electronic converter systems (PECS) are designed for batteries, solar PVs, wind, and other well-established renewable energy resources. Standards (such as IEEE 1547, UL 1741, CA Rule-21, HI Rule14) exist for PECS used for renewable energy systems such as battery storage and solar PVs. However, those that consider the dynamic behavior of HTSEs and that can be used for large-scale H2 systems are yet to be developed. This paper investigates the performance of these PECS for the HTSE application that are set up at the Idaho National Laboratory for hydrogen production testing, research and development. In particular, the performance analysis of two grid-tied PECS (A and B) is conducted for a 100 kW solid oxide HTSE system. System A consists of 6 units of 30kW MOSFET-switched bidirectional AC-DC rectifier while system B has a single unit of 150kW thyristor-switched AC-DC rectifier. Both systems are connected to the HTSE stacks via a DC-DC converter. Different operational conditions of the HTSE system are tested to analyze the dynamic response of the HTSE’s PECS. The experimental results show the need to develop advanced control strategies for PECS that incorporates the dynamics of HTSE systems for improved performance.

High temperature steam electrolysis↗

Power System Frequency Dynamics Modeling, State Estimation, and Control using Neural Ordinary Differential Equations (NODEs) and Soft Actor-Critic (SAC) Machine Learning Approaches

With the global energy transition of the electric power system, grid control, supervision, and protection is becoming more challenging. With the increasing integration of renewable energy sources (RES), the system dynamics are changing, causing traditional power system dynamic modeling with swing equation-based modeling approaches to fail. Additionally, the converter-dominated power grid is decreasing the system inertia, making the power system more fragile to the frequency swings. This paper first investigates and compares the application of a model-based Kalman filter state estimation approach with (i) a model-free machine learning approach --- neural ordinary differential equations (NODEs) --- and (ii) a data-driven system identification (SysId) approach to model and infer critical state values of the power system frequency dynamics. Then a model predictive control (MPC) framework is compared to a model-free Soft Actor-Critic (SAC) reinforcement learning (RL) control algorithm in providing efficient fast frequency response (FFR) to the power system frequency dynamics. The approaches are compared in terms of their performance goals as well as their per-timestep computational efficiency. Furthermore, the comparative study for state estimation shows that for the model-free requirement, both NODEs and SysId can provide accurate state estimates; however, with increasing model complexity, NODEs can be a better choice for model identification. Similarly, the results from the FFR comparative study show that the SAC RL-based FFR, once trained, outperforms MPC with better control signals and faster computation time, making the SAC RL-based FFR better option for providing FFR to the power system.

97 MATHEMATICS AND COMPUTING↗

Analysis of AC-DC Converters for Grid-tied High Temperature Steam Electrolysis Systems

Grid-tied HTSE systems have the prospects to produce clean hydrogen enabling power and broad energy systems decarbonization. Most commercially available power electronic converter systems (PECS) are designed for batteries, solar PVs, wind, and other well-established renewable energy resources. Standards (such as IEEE 1547, UL 1741, CA Rule-21, HI Rule-14) exist for PECS used for renewable energy systems such as battery storage and solar PVs. However, those that consider the dynamic behavior of HTSEs and that can be used for large-scale H2 systems are yet to be developed. This paper investigates the performance of these PECS for the HTSE application that are set up at the Idaho National Laboratory for hydrogen production testing, research and development. In particular, the performance analysis of two grid-tied PECS (A and B) is conducted for a 100 kW solid oxide HTSE system. System A consists of 6 units of 30kW MOSFET-switched bidirectional AC-DC rectifier while system B has a single unit of 150kW thyristor-switched ACDC rectifier. Both systems are connected to the HTSE stacks via a DC-DC converter. Different operational conditions of the HTSE system are tested to analyze the dynamic response of the HTSE’s PECS. The experimental results show the need to develop advanced control strategies for PECS that incorporates the dynamics of HTSE systems for improved performance.

08 - HYDROGEN↗

Hybrid Modeling of Three-Phase Grid-Supporting Inverters for Dynamic Studies

Grid technologies connected by power electronic converter (PEC) interfaces continually implement grid support functions mandated by grid codes and standards. The transition to converter-based generation demands precise PEC models to assess system dynamics, which have been previously overlooked in conventional power systems. This study proposes a hybrid method for analyzing grid-connected three-phase PEC dynamics with the IEEE standard 1547-2018 Volt-VAr mode that combines physics and data-driven techniques. The physics model reflects the PEC’s internal behavior, whereas the data-driven modeling technique evaluates the grid-supporting capabilities of the smart PEC. The system identification approach is used to generate dynamic PEC models based on changing grid voltage and measured current injected into the grid by the PEC. In the Volt-VAr support mode, a detailed topological model including switches is utilized to compare the goodness-of-fit of the extracted hybrid dynamic model. The results demonstrate that the hybrid PEC model in the Volt-VAr mode accurately matches the dynamics with the topological model.

Subedi, Sunil↗