Search NASA⌕ Search

SEARCH · Search NASA

Results for “power flow solution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Time-Domain Vortex Induced Vibration Modeling of Reference Dynamic Power Cable for the Gulf of Maine

Vortex-induced vibration (VIV) is a phenomenon known to decrease the fatigue life of dynamic power cables used in floating offshore wind systems through increased bending loading cycles. A variety of modeling solutions have been proposed to study this, but none enable fully-coupled simulations leveraging open-source tools. To address this, a time-domain VIV model has been successfully implemented into the open-source mooring dynamics model MoorDyn. The semi-empirical VIV model describes a lift force acting on segments of a flexible cylinder, making it well suited for implementation into MoorDyn. The new capability successfully predicted the frequencies and magnitudes of strain in both steady and oscillating flows when compared to the original validation results and matched peak spectral response when compared to experimental results, verifying successful implementation. MoorDyn with VIV was then leveraged to simulate a 15 MW floating turbine with a dynamic power cable in the Gulf of Maine using OpenFAST for six return periods of combined wind, wave, and current conditions. Increased curvature and tension fluctuations in higher flow speeds were observed when simulating VIV. Maximum tensions and curvatures also increased, with the 500 year conditions violating the curvature factor of safety of 2.0. These results highlight the importance of considering VIV when designing dynamic power cables for the Gulf of Maine, and indicate that cost effective mitigation strategies should be explored for the area. They also demonstrate the utility of this new modeling capability, which provides the first open-source tool for fully coupled time-domain floating offshore wind simulations with dynamic power cable VIV.

17 WIND ENERGY↗

Isolated Single-stage Three-phase AC/DC Converter using Bidirectional Switches

The advent of the SiC Bidirectional FET (BiDFET), a monolithic 1.2 kV bidirectional switch, has rendered the single-stage three-phase AC/DC converter topology a promising approach for implementing AC/DC converters. This topology, which integrates a full-bridge converter with a single-phase to three-phase matrix converter via a high-frequency transformer, is particularly suitable for applications requiring galvanic isolation, buck-boost functionality, and bidirectional power flow. The single-stage design eliminates the need for bulky and unreliable electrolytic capacitors, and utilizes a single magnetic component for power transfer. In the matrix converter, bidirectional switches, which were traditionally implemented using combinations of multiple semiconductor devices such as MOSFETs, IGBTs, and diodes, can now be realized using the single-chip solution, BiDFET. This advancement leads to a lower switch count, compact converter implementation, with lower inductance commutation cells, thereby enhancing the overall efficiency and compactness of the system. The paper presents a unified model of the converter, considering all control parameters, including the duty cycles and phase shift of transformer voltages. Detailed expressions for power transfer, transformer currents, and currents at AC and DC ports are provided. Additionally, the paper outlines the conditions necessary for soft-switching of all switches and the commutation schemes required for the practical implementation of the matrix converter modulation scheme. A hardware prototype of a 10 kW, 480 VRMS, LL/ 800 V AC/DC system has been developed, and experimental results are presented to demonstrate its performance.

BiDFET↗

Voltage Calculations in Secondary Distribution Networks via Physics-Inspired Neural Network Using Smart Meter Data

The increasing penetration of distributed energy resources (DERs) leads to voltage issues across distribution networks, necessitating voltage calculations by utilities. Electric model-free voltage calculation offers an enticing solution. However, most researches mainly focus on primary distribution networks ignoring secondary distribution networks and commonly overlook extreme voltage case calculations, which require the model’s extrapolation abilities. Here, in addressing the gaps, this paper presents a customized physics-inspired neural network (PINN) model, the structure of which is inspired by the derived coupled power flow model of primary-secondary distribution networks. To ensure precision and rapid convergence, a crafted training framework for the PINN model is proposed. The PINN’s “structure-mimetic” design enables superior extrapolation for unseen scenarios and enhances physical information awareness. We demonstrate this through two applications: hosting capacity analysis and customer-transformer connectivity. The effectiveness and advantages of the proposed PINN model are validated on two public testing systems and one utility distribution feeder model.

Distribution network↗

Integration of a Concentrating Solar Steam Topping Turbine to an Existing Geothermal Binary Power Plant (CRADA CRD-17-700 Final Report)

U.S. Geothermal Inc. is a publicly traded leading renewable energy company focused on the development, production, and sale of electricity from geothermal energy with operating generation facilities at Raft River, Idaho; San Emidio, Nevada; and Neal Hot Springs, Oregon. (U.S. Geothermal was acquired by Ormat Technologies, Inc. since the execution of this project). This project will evaluate the integration of a concentrating solar steam topping cycle with a geothermal bottoming binary cycle. This hybrid plant configuration will enable high efficiency conversion of the solar heat to electrical power, while simultaneously increasing the power output of the bottoming cycle. Such a design has the potential to reduce the cost of electrical power from concentrating solar power (CSP) and geothermal plants, and a viable design could be deployed at existing geothermal plants that have experienced resource productivity decline as well as in greenfield projects. This analysis will examine US Geothermal’s Raft River power plant for implementation of this concept. INL and NREL have previously collaborated in the analysis of geo-solar hybrid power plants. These two labs will again work together to model the solar field, steam-topping, and geothermal bottoming cycles in order to investigate the performance of the proposed cycle. This analysis will provide US Geothermal with technical information including equipment specifications and estimated power generation necessary to advance the concept toward implementation. A successful project outcome has two parts: One would be for US Geothermal to have a process flow diagram (heat and mass balance), and performance parameters for the major pieces of equipment. US Geothermal could then use this information evaluate the techno-economic feasibility of the hybrid power cycle, and serve as the basis for subsequent detailed equipment design, purchase, and installation of the cycle. The second would be for the developed solution to be published by DOE for use by other geothermal developers both to retrofit underperforming plants and to lower the LCOE of new developments.

15 GEOTHERMAL ENERGY↗

Resolution requirements for energy conservation in kinetic plasma simulations

The kinetic codes used to model the coupled dynamics of electromagnetic fields and charged particle transport have requirements for spatial, temporal, and charge resolution. These requirements may vary by the solution technique and scope of the problem. In this report, we investigate the resolution limits in the energy-conserving implicit particle-in-cell code CHICAGO. This report has the narrow aim of determining the maximum acceptable grid spacing for the dense plasmas generated in models of z-pinch target gases and power-flow electrode plasmas. In the 2D sample problem, the plasma drifts without external forces with velocity of 10 cm/µs. Simulations are scaled by plasma density to maintain uniform strides across the plasma and from the plasma to the boundaries. Additionally, the cloud-in-cell technique is used with 400 particles per cell and Δ t = 0.85× the Courant limit. For the linear cloud distribution, the criterion for conserving energy is Δ E/E tot < 0.01 for 50,000 time steps. The grid resolution is determined to crudely be Δx ≲ 3 l s , where l s is the electron collisionless skin depth. For the second-order cloud distribution the criterion is Δ E/E tot < 0.005 yielding Δx ≤ 15 l s . These scalings are functions of the chosen v d , Δ t , particles-per-cell, and number of steps.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Iterative Approach for Solving the SCOPF Problem Applying LP, SOCP, and NLP Subproblems

We propose to develop efficient algorithms and software for the SCOPF problem. We will employ an iterative approach that will: a) use linear subproblems and other active set filtering techniques to identify the most important contingencies and drastically reduce the SCOPF model size; b) solve SOCP relaxations of the reduced SCOPF to converge to the neighborhood of the global optimal solution and establish a lower bound on the solution, and; c) use a non-convex, nonlinear interior-point solver, Artelys Knitro, to converge quickly to the optimal solution. To identify the most effective approach, we will experiment with several techniques to identify the tradeoffs between contingency subproblem complexity and fast solvability.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Multidimensional Modeling of Mixture Formation in a Hydrogen-Fueled Heavy-Duty Optical Engine With Direct Injection

Hydrogen (H 2 ), as a carbon-free fuel, is considered as one of the most promising solutions to reduce the carbon footprint of hard-to-decarbonize energy and transportation sectors. As such, hydrogen-fueled internal combustion engines (H 2 ICEs) have recently been receiving increasing attention, particularly in applications such as on-road/off-road heavy-duty transport and combined heat and power. The direct injection (DI) of gaseous hydrogen into the combustion chamber offers great potential for achieving high power density and high engine efficiency, while mitigating the risk of backfire and reducing pre-ignition. However, the numerical simulation of H 2 DI system remains a formidable challenge associated with the high computational cost of reproducing compressible supersonic flow and shocks in narrow injector passages and in near-nozzle regions. In general, there is a lack of well-established and validated practices for the modeling of high-pressure H 2 DI in large-bore engines. Here, to this end, this study focuses on computational fluid dynamics (CFD) modeling of the mixture formation process in a heavy-duty optical engine employing a medium-pressure H 2 DI system. Both large eddy simulations (LES) and Reynolds Averaged Navier–Stokes (RANS) simulations are performed and evaluated against optical data. Gaseous hydrogen is injected into the combustion chamber via a centrally located outward opening hollow-cone injector at a pressure of 40 bar. Simulations are carried out for two injection timings, namely, −120 and −60 °CA. The numerical predictions for H 2 distribution in different horizontal and vertical planes during the compression stroke are systematically compared against optical data obtained through planar laser-induced fluorescence (PLIF) measurements. Overall, the LES approach using the Dynamic Structure model is found to have good predictive capabilities for the early jet penetration in terms of length and shape, as well as the later H 2 distributions. However, the unsteady RANS approach with the renormalization group $k - ϵ$ model, which is widely used by industry to model heavy-duty ICEs, significantly underpredicts the H 2 mixing, even at similar mesh resolution to that used in LES. These results indicate that there is a need for the improvement of mixing submodels within the RANS approach when applied to H 2 DI simulations.

LES↗

An Investigation of the Effects of Volume Fraction on Drag Coefficient of Non-Spherical Particles Using PR-DNS

Prediction of the drag coefficient is required in gas-particle multiphase flow modeling and simulation. Experimental data and correlations on the fixed-bed system of spherical particles with high volume fractions for various possible arrangements are available in the literature. However, the effect of volume fraction on the drag coefficient of non-spherical particles is not well studied. In solving the momentum equation, the volume fraction plays a vital role in determining the flow resistances. In this paper, we study the impact of volume fraction in the range of 0.069 to 0.65 on the drag coefficient using the computational fluid dynamics (CFD) simulation of air for Reynold number in the range of 10 to 10000 using particle resolved direct numerical solution (PR-DNS). Regular non-spherical particles such as a cube, tetrahedron, and spheroids are used in this study since their single particle’s drag coefficient data are available in the literature for comparison. For this work, the simulations are carried out in the Ansys Fluent using polyhedral mesh, which consumes significantly less computational time and power. The study showed the sphericity and volume fraction have significant impact on the bed pressure drop and average drag coefficient of the particles in the bed especially in high Reynolds number regime. The bed of the spheroid experiences the lowest drag being the most streamlined particle, and the particles with the edges result in a large drag coefficient due to flow separation at the discontinuity. The vector plots verify this behavior where large wake regions are observed behind the tetrahedron particle.

Mahyawansi, Pratik↗

Voltage regulation in distribution grids: A survey

Environmental and sustainability concerns have caused a recent surge in the penetration of distributed energy resources into the power grid. This may lead to voltage violations in the distribution systems making voltage regulation more relevant than ever. Owing to this and rapid advancements in sensing, communication, and computation technologies, the literature on voltage control techniques is growing at a rapid pace in distribution networks. In particular, there is a paradigm shift from traditional offline centralized approaches to distributed ones leveraging increased and varied types of actuators, real-time sensing, fast and efficient computations, and an overall distributed situational awareness. This paper reviews state-of-the-art voltage control algorithms, summarizes the underlying methods, and classifies their coordination mechanisms into local, centralized, distributed, and decentralized. The underlying solution methodologies are further classified into two categories, open-loop and feedback-based. Two specific example workflows are provided to illustrate these solutions for voltage regulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A learning-augmented approach for AC optimal power flow

Because of the high nonlinearity of AC optimal power flow (OPF), numerous efforts have been made in recent decades to find efficient methods. Machine learning (ML) has proven to significantly reduce the computational costs in many real-world problems. Thus, this paper develops a learning-augmented method for solving AC OPF, which integrates both power network equations and ML to yield near-optimal solutions. More specifically, ML models are developed to first predict bus voltage magnitudes and angles. Then, physics-based network equations are employed to calculate the power injection at different buses. Three ML algorithms, i.e., random forest, multi-target decision tree, and extreme learning machine, are explored and compared. To evaluate the efficiency of the proposed learning-augmented AC OPF solver, the MATPOWER Interior Point Solver is adopted as a baseline. Case studies on both 500-bus and 4918-bus test networks show that the proposed learning-augmented method has reduced the computational time by 15–100 times depending on the network size with a minimal loss in optimality.

42 ENGINEERING↗

Mitigating spectral bias in neural operators via high-frequency scaling for physical systems

Neural operators have emerged as powerful surrogates for modeling complex physical problems. However, they suffer from spectral bias making them oblivious to high-frequency modes, which are present in multiscale physical systems. Therefore, they tend to produce over-smoothed solutions, which is particularly problematic in modeling turbulence and for systems with intricate patterns and sharp gradients such as multi-phase flow systems. In this work, we introduce a new approach named high-frequency scaling (HFS) to mitigate spectral bias in convolutional-based neural operators. By integrating HFS with proper variants of UNet, we demonstrate a higher prediction accuracy by mitigating spectral bias in single and two-phase flow problems. Unlike Fourierbased techniques, HFS is directly applied to the latent space, thus eliminating the computational cost associated with the Fourier transform. Additionally, we investigate alternative spectral bias mitigation through a diffusion model conditioned on neural operators. While the diffusion model integrated with the standard neural operator may still suffer from significant errors, these errors are substantially reduced when the diffusion model is integrated with a HFS-enhanced neural operator.

97 MATHEMATICS AND COMPUTING↗

Real-time Simulation Model of a Vanadium Redox Flow Battery Energy Storage System with Power Electronics Integration

This paper presents a real-time (RT) model of a 20 kW multi-stack vanadium redox flow battery (VRFB) system including power electronics converters in a single real-time framework. Implemented on a Typhoon HIL 604 device, this model is designed to simulate the operation of the flow battery with system-level controls. To provide a realistic overview of a VRFB system, the model incorporates a closed-loop control system for managing the speeds of two centrifugal pumps and an electro-thermal model of the battery stacks, enabling realtime temperature estimation. Furthermore, a two-stage power electronics topology and associated control solution are presented, operating with distinct strategies for interfacing the battery model with the main grid and a local load. Results from simulations demonstrate that the VRFB model is well suited for RT environment, and system can manage power during both charging and discharging cycles, while a SCADA monitor is used to display critical variables for safe, efficient, and reliable operation of the VRFB systems.

Rezende Da Costa Reis Kimpara, Renata [ORNL] (ORCI↗

Optimizing HVAC Operations in Multi-unit Buildings for Grid Demand Response

The thermal inertia of buildings, along with the flexibility associated with thermostatically controlled loads (TCL) allows heating ventilation and cooling (HVAC) systems to be used for grid demand response (DR). In this work, we consider an HVAC system that serves multiple units in a residential building to meet their space heating requirements. We aim to determine the optimal power flow to each unit that minimizes the power costs incurred by the building's occupants while keeping in consideration their thermal comfort. The DR program is assumed to allow the building temperatures to deviate from the set-points up to a maximum limit. Despite the complex, non-linear structure of the problem, we show how the optimal solutions can be obtained efficiently using quadratic programming. Since HVAC systems can run on either electricity or natural gas, we study the efficacy of the DR regime for both hourly electricity prices and flat gas prices over the course of 24 hours. Finally, we run simulations to determine the optimal thermal power and the evolution of unit temperatures for various energy pricing schemes.

Naqvi, Syed A.↗

Tightest Mixed-Integer Programming Formulations for Quadratic SCUC Optimization

In this project, we developed new, tighter Mixed-Integer Programming (MIP) formulations for the combined Alternating Current (AC) Security-Constrained Unit Commitment (SCUC) and Security-Constrained Optimal Power Flow (SCOPF). The work addresses a critical challenge in power system operations: efficiently determining which generation units to commit and how to optimally dispatch them while maintaining network reliability constraints for both normal and contingency scenarios. Our efforts: 1. Advance the Understanding of SCUC/SCOPF Modeling: By introducing tighter MIP formulations and leveraging cutting-edge optimization tools (Julia/JuMP, PowerModels.jl), this project has pushed forward the state of the art in efficient power systems scheduling. 2. Enhance Technical and Economic Feasibility: The methods developed provide more accurate and potentially faster solutions to large-scale, realistic scheduling and dispatch problems in electric power systems, which can translate into improved reliability and potentially lower costs for grid operations. 3. Benefit to the Public: Greater efficiency in power system operations leads to cost savings for utilities and end-users. Improved reliability and integration of advanced modeling approaches can facilitate the adoption of clean energy resources and better accommodate uncertainties in renewable generation. Because this technology could impact bulk power markets and reliability, these innovations have far-reaching public benefits in terms of cost savings, reliability, and sustainability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data Centers and Digital Assurance Workshop 3 – Mitigations for Digital Assurance Risks

The third session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort, held on November 18, 2025, focused on developing mitigation strategies for digital assurance risks identified in previous workshops. Hosted by Idaho National Laboratory (INL) and ScottMadden, the session emphasized the application of Cyber-Informed Engineering (CIE) to data center infrastructure, particularly at the utility–data center interface. Participants revisited and ranked key digital assurance risks, including architecture and interface weaknesses, governance gaps, and AI-enabled threats. The workshop introduced the 12 principles of CIE, advocating for consequence-focused design, engineered controls, and secure information architecture to proactively reduce cyber-physical vulnerabilities. These principles were applied to critical data center systems such as power distribution, UPS, cooling, SCADA/BMS, and grid-forming batteries. The session also addressed governance challenges at the interconnection boundary, highlighting the need for clear roles in telemetry sharing, firmware management, and trip settings. Special attention was given to emerging risks from behind-the-meter (BTM) generation, including reverse-power flow and the integration of small modular reactors (SMRs), which shift data centers from large loads to complex generation nodes. Participants explored how interconnection agreements can serve as enforceable instruments for digital assurance, and reviewed gaps in current standards such as NERC CIP, IEC 62443, and IEEE 1547. The workshop concluded with pathways to standardization, including model agreement language, state-level programs, and expanded NERC guidance. INL also presented tools and frameworks for secure procurement and supplier risk management, reinforcing the need for integrated engineering and policy solutions to secure the evolving data center–grid ecosystem. Session 3 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

A Hierarchical Volt-var Optimization with Discrete Variables in Unbalanced Distribution Systems

This paper proposes a framework to determine the optimal active and reactive power dispatch of distributed photovoltaic (PV) generation, switched capacitors, and voltage regulators in multi-phase unbalanced distribution systems. The objectives of the optimal dispatch are minimization of the energy loss, PV real power curtailment, and switching operations of capacitors and voltage regulators, in addition to elimination of voltage violation and reverse power flow. The optimization problem is formulated in rectangular coordinates as a nonlinear, nonconvex problem with discrete variables. A hierarchical twostage framework is proposed to effectively handle those discrete variables and reduce the computational time compared to the unified approach in which all variables are solved simultaneously. The efficacy of the proposed approach and the accuracy of the obtained numerical solution is validated using the unbalanced multi-phase IEEE 34-bus with 15-minute load and PV data.

Nguyen, Quan H.↗