Characteristics of the earth radiation budget experiment solar monitors

The earth radiation budget experiment solar monitors, active cavity pyrheliometers, have been developed to measure every two weeks the total optical solar irradiance from the earth radiation budget satellite (ERBS) and the National Oceanic and Atmospheric Administration NOAA-9 spacecraft platforms. In the unfiltered 0.2-50-micron wavelength broadband region, the monitors were used to obtain 1365 W/sq m as the mean value for the solar irradiance, with measurement precisions and accuracies approaching 0.1 and 0.2 percent, respectively. The design and characteristics of the solar monitors are presented along with the data reduction model. For the October 1984 through July 1985 period, the resulting ERBS and NOAA-9 solar irradiance values are intercompared.

Lee, Robert B., III↗

Experimental facilities for system identification

Future space vehicles will differ significantly from the space systems used in the past. The planned spacecraft configurations will include extremely large structures, up to 100-200 meters across. Because the allowable launch weights are limited, the large space structures must be constructed of lightweight, flexible elements, and active control of the shape and attitude of the spacecraft will be required. The behavior of large structures is characterized by many closely spaced natural modes, and some applications may also include large on-board disturbances. Consequently, the control and disturbance forces will invariably spill over to a large number of modes. Structural identification will be necessary for precision pointing and shape controls to be effective. An accurate mathematical model of a structure is essential for the success of precision control system design. However, the currently available analytical modeling codes, such as NASTRAN, are incapable of producing numerical models of the required precision. The favored approach for model determination is to refine the mathematical model based on experiments in the orbital environment. It is to this effect that we must develop techniques to reliably generate the accurate models required for future missions, and the arena in which these methods will be developed and proved is through ground-based system identification experiments and demonstrations. The Air Force Astronautics Laboratory (AFAL) has expanded the on-site ground-test facilities in recent years, and additional sites are planned for the immediate future. We shall review the plans for laboratory growth at AFAL with regard to the type of experiments proposed and the availability of the new facilities.

Das, Alok↗

A sub-cm micromachined electron microscope

A new approach for fabricating macroscopic (approximately 10x10x10 mm(exp 3)) structures with micron accuracy has been developed. This approach combines the precision of semiconductor processing and fiber optic technologies. A (100) silicon wafer is anisotropically etched to create four orthogonal v-grooves and an aperture on each 10x12 mm die. Precision 308 micron optical fibers are sandwiched between the die to align the v-grooves. The fiber is then anodically bonded to the die above and below it. This procedure is repeated to create thick structures and a stack of 5 or 6 die will be used to create a miniature scanning electron microscope (MSEM). Two die in the structure will have a segmented electrode to deflect the beam and correct for astigmatism. The entire structure is UHV compatible. The performance of an SEM improves as its length is reduced and a sub-cm 2 keV MSEM with a field emission source should have approximately 1 nm resolution. A low voltage high resolution MSEM would be useful for the examination of biological specimens and semiconductors with a minimum of damage. The first MSEM will be tested with existing 6 micron thermionic sources. In the future a micromachined field emission source will be used. The stacking technology presented in this paper can produce an array of MSEMs 1 to 30 mm in length with a 1 mm or larger period. A key question being addressed by this research is the optimum size for a low voltage MSEM which will be determined by the required spatial resolution, field of view, and working distance.

Feinerman, A. D.↗

Human Tracking Performance in Uncoupled and Coupled Two-Axis Systems

This report presents tile results of an experimental and analytical study of human performance in uncoupled and coupled control systems. Human pilot performance in single and two-axis systems was mathematically modeled by linear second-order describing functions. Model parameters were determined using model matching techniques. Analysis of the models showed that the amplitude ratio and phase lead of the describing function increased with training indicating an increase in open loop bandwidth. The phase margin also decreased with training. Increasing the plant lag time constant resulted in an increase in the model lead time constant and a decrease in the zero frequency gain. No significant difference was found to exist in the normalized tracking error per axis between the two-axis tasks and the single-axis tasks. However tile model lead time constant was significantly greater in two-axis tracking. Manual tracking of two-axis systems with cross-coupling was studied experimentally and analytically. Approximate methods for modeling two-axis performance were developed and checked using a precise spectral analysis approach. Coupled and uncoupled, symmetrical and asymmetrical two-axis performance was compared. The results show that modeling of cross-coupled systems is feasible and that trained subjects are capable of decoupling the axes of some systems. A methodology study compared the identification performance of continuous, iterative, and extrapolation model matching techniques. An iterative technique employing sensitivity equations for the generation of influence coefficients was found to be the best technique due to its excellent identification accuracy and ease of implementation. Convergence in iterative techniques can be improved substantially by equalizing the parameter adjustment rates and limiting the maximum correction per iteration.

Todosiev, E. P.↗

CHAMP - Camera, Handlens, and Microscope Probe

CHAMP (Camera, Handlens And Microscope Probe) is a novel field microscope capable of color imaging with continuously variable spatial resolution from infinity imaging down to diffraction-limited microscopy (3 micron/pixel). As an arm-mounted imager, CHAMP supports stereo-imaging with variable baselines, can continuously image targets at an increasing magnification during an arm approach, can provide precision range-finding estimates to targets, and can accommodate microscopic imaging of rough surfaces through a image filtering process called z-stacking. Currently designed with a filter wheel with 4 different filters, so that color and black and white images can be obtained over the entire Field-of-View, future designs will increase the number of filter positions to include 8 different filters. Finally, CHAMP incorporates controlled white and UV illumination so that images can be obtained regardless of sun position, and any potential fluorescent species can be identified so the most astrobiologically interesting samples can be identified.

Mungas, G. S.↗

CHAMP (Camera, Handlens, and Microscope Probe)

CHAMP (Camera, Handlens And Microscope Probe)is a novel field microscope capable of color imaging with continuously variable spatial resolution from infinity imaging down to diffraction-limited microscopy (3 micron/pixel). As a robotic arm-mounted imager, CHAMP supports stereo imaging with variable baselines, can continuously image targets at an increasing magnification during an arm approach, can provide precision rangefinding estimates to targets, and can accommodate microscopic imaging of rough surfaces through a image filtering process called z-stacking. CHAMP was originally developed through the Mars Instrument Development Program (MIDP) in support of robotic field investigations, but may also find application in new areas such as robotic in-orbit servicing and maintenance operations associated with spacecraft and human operations. We overview CHAMP'S instrument performance and basic design considerations below.

robotic field investigations↗

Wellbore integrity assessment with casing-based advanced sensing

Wellbore integrity is of paramount importance to subsurface resource extraction, energy storage 1 and waste disposal. After installation, well casing and cement are subject to mechanical stress due to near-well pressure changes and fluid induced corrosion. This is exacerbated for geothermal wells where produced fluid is at high temperature and corrosive. The current state-of-the-art technologies for wellbore integrity assessments are an array of cased hole logging tools. Wireline deployed acoustic, electromagnetic and mechanical tools are all available to inspect steel casing corrosion and casing-cement bond and these tools can provide high-resolution assessment of borehole conditions. They are intrusive, however, in terms of borehole preparation and interruption to the normal operation of the wells, and not suitable for high temperature or highly deviated well deployments. In addition, these measurements are performed infrequently due to high cost, and are therefore incapable of providing frequent data to better predict borehole degradation trajectory, which can help provide early warning of potential borehole failures. For this project we are developing a suite of novel, non-invasive, casing based tools for wellbore integrity assessment, combining fast/low cost screening with higher-precision investigation. Our approach is based on monitoring the response of the casing when energized at the wellhead, thereby interrogating the casing without well intervention. Lab, field and numerical approaches are used in our study. During the early stage of the research, we focus on numerical simulations, which have shown the sensitivity of the low frequency electromagnetic (EM) signals to changes in borehole depths and have successfully tested the concept at a field site with different length well casings. Initial seismic modeling efforts have also demonstrated our capability to simulate seismic tube wave and seismic field alterations due to borehole breakage and associated fluid leakage. Further numerical, laboratory and field experiments are underway for additional technology sensitivity analysis, particularly the transient EM/Seismic reflectometry methods, data acquisition optimization, and numerical simulation improvements.

Wilt, Michael↗

A Signal Detection Theory Approach to Evaluating Oculometer Data Quality

Currently, data quality is described in terms of spatial and temporal accuracy and precision [Holmqvist et al. in press]. While this approach provides precise errors in pixels, or visual angle, often experiments are more concerned with whether subjects'points of gaze can be said to be reliable with respect to experimentally-relevant areas of interest. This paper proposes a method to characterize oculometer data quality using Signal Detection Theory (SDT) [Marcum 1947]. SDT classification results in four cases: Hit (correct report of a signal), Miss (failure to report a ), False Alarm (a signal falsely reported), Correct Reject (absence of a signal correctly reported). A technique is proposed where subjects' are directed to look at points in and outside of an AOI, and the resulting Points of Gaze (POG) are classified as Hits (points known to be internal to an AOI are classified as such), Misses (AOI points are not indicated as such), False Alarms (points external to AOIs are indicated as in the AOI), or Correct Rejects (points external to the AOI are indicated as such). SDT metrics describe performance in terms of discriminability, sensitivity, and specificity. This paper presentation will provide the procedure for conducting this assessment and an example of data collected for AOIs in a simulated flightdeck environment.

Latorella, Kara↗

Atomically Precise Membranes for the Separation of Gases

Industrial separations require enormous amounts of energy, accounting for approximately half the industrial energy use and 10–15% of the total energy consumption. Distillation alone accounts for about half the energy demand for industrial separations. If these processes could be replaced by an energy-efficient membrane separation process, this energy demand could be reduced by 90%. However, although some membrane processes have made inroads into thermal distillation, for membrane-based separations to replace the distillation process to a far more significant and practical level, new membranes with higher robustness, selectivity, and flux still need be developed. In this membrane development program, we leveraged Temple University’s prior work in spiroligomers to develop robust membrane structures. These structures can be formed into atomically precise pores by controlling the chemical synthesis and the oligomer building blocks to first build precisely controlled macrocycles and then subsequently crosslinking these macrocycles to produce a membrane. Furthermore, through the highly controllable chemistry of our molecular building blocks, not only can we integrate pores with highly controllable and reproducible size and morphology, but we can also target internal functionalization. By using a range of scalable membrane synthesis approaches, combined with control of each and every pores internal chemistry and molecular conformation we can achieve membrane structures that can display the ultimate in high selectivity and permeance. The Mainstream-Temple University membranes can be designed to achieve ultra-selective separations based on the key factors of molecular size, shape, and functionality. In our approach to fabricate scalable atomically precise membranes, we used our molecular Lego nanostructures. We demonstrated an approach to create atomically precise pores within the membrane with pores that are the dimensions of the molecule we are trying to separate. Moreover, in addition to controlling the morphology of the membrane structure by controlling the size of every pore, we can also decorate every pore with precisely targeted and placed functional groups. These accurately placed functional groups can provide selective binding to molecules and provide enhanced selectivity via a facilitated transport mechanism. In Phase II, the Mainstream-Temple University team demonstrated the scalable synthesis of oligomers and the ability to control the pore internal and external functionality, or chemistry, to allow the fabrication of a thin-film membrane. The initial steps of the spiroligomer synthesis to produce the two key bis-amino enantiomer building blocks were scaled from the gram scale to the kilogram scale, obtaining 25 kg of the materials by transferring the procedure to a toll manufacturer. Finally, we successfully optimized the fabrication of these macrocycles into robust membranes. We successfully transitioned from a laboratory based, hard-to-scale Langmuir trough synthesis to a highly scalable, roll-to-roll applicable, interfacial polymerization process. During this Phase II program, we established a platform of atomically precise membranes where our highly controllable, atomically precise macrocycles served as a scaffold with precisely and uniformly controlled pores. Furthermore, this layer can be tailored to accommodate a diverse range of functional groups, which both further controlled the pore size to enhance the sieving effect as well as imparting precisely controlled targeted selectivity through biomimetic molecular interactions. In this Phase II, we established and scaled up a platform approach to both tune the pore size and chemistry as well as scale it to produce membranes that can be applied to a wide range of industries. In future development, the project team expects to scale up both the macrocycle building block production and interfacial polymerization process to produce the atomically precise membrane with targeted pore sizes and pore chemistries.

36 MATERIALS SCIENCE↗

Design concepts for large reflector antenna structures

Practical approaches for establishing large, precise antenna reflectors in space are described. Reflector surfaces consisting of either solid panels or knitted mesh are considered. The approach using a deep articulated truss structure to support a mesh reflector is selected for detailed investigations. A new sequential deployment concept for the tetrahedral truss is explained. Good joint design is discussed, and examples are described both analytically and by means of demonstration models. The influence of curvature on the design and its vibration characteristics are investigated.

Hedgepeth, J. M.↗

Nickel Accounting for the Psyche Spacecraft

(16) Psyche is a metallic asteroid located in the asteroid belt between Mars and Jupiter. The composition of Psyche is unknown, but the scientific community believes it is composed primarily of iron, nickel, and silicates. The Psyche mission will be the first space mission to study this asteroid in close proximity, and as such, determining the elemental composition of the asteroid is one of the primary objectives of this mission. The spacecraft measures this elemental composition using the Gamma Ray Spectrometer (GRS), which detects cosmic-ray induced gamma rays from Psyche’s surface. In addition to gamma rays from Psyche, the GRS will also detect background gamma rays from spacecraft material nearby the GRS. Because Ni is such a key element for achieving the mission science objectives, a special effort has been made to minimize background gamma rays from Ni, thus maximizing sensitivity to the Ni gamma rays from Psyche. The Psyche mission approached this potential Ni background issue with two methods, locating the GRS away from the spacecraft/source of Ni and setting a threshold requirement against the total Ni mass of the spacecraft. Verifying that the total amount of Ni on the spacecraft is within this threshold is thus a key part of ensuring the GRS can meet its science objectives. Ni alloys are commonly used on spacecraft, but the mass and location of elemental Ni is not typically accounted for. Ni can be found in many materials all over the spacecraft – in fasteners, optical assemblies, magnetic shields, electromagnetic interference (EMI) tape, under gold plating, in connectors, and so on. The task proved further challenging because of the distributed nature of the build of this spacecraft and the use of vendors external to JPL. While the analysis was atypical and source information difficult to cull, the approach described in this paper used tools and data available to the project in some form to achieve this goal. For Psyche, current analysis shows there is margin in meeting the Ni mass requirement. This paper explains the systematic approach used to accurately and precisely record Ni content on the Psyche spacecraft. While this approach was defined for Ni on the Psyche mission, it can be used for any future project with the need to accurately estimate the total mass of a single element or material on a spacecraft.

Cullinan, Joe↗

Nickel Accounting for the Psyche Spacecraft

(16) Psyche is a metallic asteroid located in the asteroid belt between Mars and Jupiter. The composition of Psyche is unknown, but the scientific community believes it is composed primarily of iron, nickel, and silicates. The Psyche mission will be the first space mission to study this asteroid in close proximity, and as such, determining the elemental composition of the asteroid is one of the primary objectives of this mission. The spacecraft measures this elemental composition using the Gamma Ray Spectrometer (GRS), which detects cosmic-ray induced gamma rays from Psyche’s surface. In addition to gamma rays from Psyche, the GRS will also detect background gamma rays from spacecraft material nearby the GRS. Because Ni is such a key element for achieving the mission science objectives, a special effort has been made to minimize background gamma rays from Ni, thus maximizing sensitivity to the Ni gamma rays from Psyche. The Psyche mission approached this potential Ni background issue with two methods, locating the GRS away from the spacecraft/source of Ni and setting a threshold requirement against the total Ni mass of the spacecraft. Verifying that the total amount of Ni on the spacecraft is within this threshold is thus a key part of ensuring the GRS can meet its science objectives. Ni alloys are commonly used on spacecraft, but the mass and location of elemental Ni is not typically accounted for. Ni can be found in many materials all over the spacecraft – in fasteners, optical assemblies, magnetic shields, electromagnetic interference (EMI) tape, under gold plating, in connectors, and so on. The task proved further challenging because of the distributed nature of the build of this spacecraft and the use of vendors external to JPL. While the analysis was atypical and source information difficult to cull, the approach described in this paper used tools and data available to the project in some form to achieve this goal. For Psyche, current analysis shows there is margin in meeting the Ni mass requirement. This paper explains the systematic approach used to accurately and precisely record Ni content on the Psyche spacecraft. While this approach was defined for Ni on the Psyche mission, it can be used for any future project with the need to accurately estimate the total mass of a single element or material on a spacecraft.

Cullinan, Joe↗

Anharmonic phonon behavior via irreducible derivatives: Self-consistent perturbation theory and molecular dynamics

Cubic phonon interactions are now regularly computed from first principles, and the quartic interactions have begun to receive more attention. Given this realistic anharmonic vibrational Hamiltonian, the classical phonon Green's function can be precisely measured using molecular dynamics, which can then be used to rigorously assess the range of validity for self-consistent diagrammatic approaches in the classical limit. Here we use the bundled irreducible derivative approach to efficiently and precisely compute the cubic and quartic phonon interactions of CaF 2 , systematically obtaining the vibrational Hamiltonian purely in terms of irreducible derivatives. We demonstrate that the 4-phonon sunset diagram has an important contribution to the optical phonon linewidths beyond T = 500 K. Reasonable results are obtained even at T = 900 K when performing self-consistency using the 4-phonon loop diagram and evaluating the 3-phonon bubble and 4-phonon sunset diagrams post-self-consistency. Further improvements are obtained by performing quasiparticle perturbation theory, where both the 4-phonon loop and the real part of the 3-phonon bubble are employed during self-consistency. Finally, our irreducible derivative approach to self-consistent perturbation theory is a robust tool for studying anharmonic phonons in both the quantum and classical regimes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A precise GPS-based time and frequency system

An approach to implementing a compact, highly reliable and precise Master Time and Frequency subsystem usable in a variety of applications is described. These applications include, among others, Satellite Ground Terminals, Range Timing Stations, Communications Terminals, and Power Station Timing subsystems. All time and frequency output signals are locked to Universal Time via the GPS Satellite system. The system provides for continued output of precise signals in the event of GPS signal interruption from antenna or lead-in breakage or other causes. Cost/performance tradeoffs affecting system accuracy over the short, medium, and long term are discussed. A unique approach to redundant system design provides an architecture with the reliability advantage of triple-redundant majority voting and the cost advantages of dual-redundant elements. The system can be configured to output a variety of precise time and frequency signals and the design can be tailored to output as few, or as many, types and quantities of signals as are required by the application.

Mcnabb, Jack↗

Direct Synthesis of Layer-Tunable and Transfer-Free Graphene on Device-Compatible Substrates Using Ion Implantation Toward Versatile Applications

Direct synthesis of layer-tunable and transfer-free graphene on technologically important substrates is highly valued for various electronics and device applications. State of the art in the field is currently a two-step process: a high-quality graphene layer synthesis on metal substrate through chemical vapor deposition (CVD) followed by delicate layer transfer onto device-relevant substrates. Here, we report a novel synthesis approach combining ion implantation for a precise graphene layer control and dual-metal smart Janus substrate for a diffusion-limiting graphene formation to directly synthesize large area, high quality, and layer-tunable graphene films on arbitrary substrates without the post-synthesis layer transfer process. Carbon (C) ion implantation was performed on Cu–Ni film deposited on a variety of device-relevant substrates. A well-controlled number of layers of graphene, primarily monolayer and bilayer, is precisely controlled by the equivalent fluence of the implanted C-atoms (1 monolayer ~4 × 10 15 C-atoms/cm 2 ). Upon thermal annealing to promote Cu-Ni alloying, the pre-implanted C-atoms in the Ni layer are pushed toward the Ni/substrate interface by the top Cu layer due to the poor C-solubility in Cu. As a result, the expelled C-atoms precipitate into a graphene structure at the interface facilitated by the Cu-like alloy catalysis. After removing the alloyed Cu-like surface layer, the layer-tunable graphene on the desired substrate is directly realized. The layer-selectivity, high quality, and uniformity of the graphene films are not only confirmed with detailed characterizations using a suite of surface analysis techniques but more importantly are successfully demonstrated by the excellent properties and performance of several devices directly fabricated from these graphene films. Molecular dynamics (MD) simulations using the reactive force field (ReaxFF) were performed to elucidate the graphene formation mechanisms in this novel synthesis approach. With the wide use of ion implantation technology in the microelectronics industry, this novel graphene synthesis approach with precise layer-tunability and transfer-free processing has the promise to advance efficient graphene-device manufacturing and expedite their versatile applications in many fields.

36 MATERIALS SCIENCE↗

Outline of a new approach to the analysis of complex systems and decision processes.

Development of a conceptual framework for dealing with systems which are too complex or too ill-defined to admit of precise quantitative analysis. The approach outlined is based on the premise that the key elements in human thinking are not numbers, but labels of fuzzy sets - i.e., classes of objects in which the transition from membership to nonmembership is gradual rather than abrupt. The approach in question has three main distinguishing features - namely, the use of so-called 'linguistic' variables in place of or in addition to numerical variables, the characterization of simple relations between variables by conditional fuzzy statements, and the characterization of complex relations by fuzzy algorithms.

Zadeh, L. A.↗

Lessons from the GP-B Experience for Future Fundamental Physics Missions in Space

Gravity Probe B launched in April 2004 and completed its science data collection in September 2005, with the objective of sub-milliarcsec measurement of two General Relativistic effects on the spin axis orientation of orbiting gyroscopes. Much of the technology required by GP-B has potential application in future missions intended to make precision measurements. The philosophical approach and experiment design principles developed for GP-B are equally adaptable to these mission concepts. This talk will discuss GP-B's experimental approach and the technological and philosophical lessons learned that apply to future experiments in fundamental physics. Measurement of fundamental constants to high precision, probes of short-range forces, searches for equivalence principle violations, and detection of gravitational waves are examples of concepts and missions that will benefit kern GP-B's experience.

Kolodziejczak, Jeffery↗

Moment extraction using an unfolding protocol without binning

Deconvolving (“unfolding”) detector distortions is a critical step in the comparison of cross-section measurements with theoretical predictions in particle and nuclear physics. However, most existing approaches require histogram binning while many theoretical predictions are at the level of statistical moments. We develop a new approach to directly unfold distribution moments as a function of another observable without having to first discretize the data. Our moment unfolding technique uses machine learning and is inspired by Boltzmann weight factors and generative adversarial networks (GANs). We demonstrate the performance of this approach using jet substructure measurements in collider physics. With this illustrative example, we find that our moment unfolding protocol is more precise than bin-based approaches and is as or more precise than completely unbinned methods.