Observations of Ocean Surface Wave Attenuation in Sea Ice Using Seafloor Cables

Abstract The attenuation of ocean surface waves during seasonal ice cover is an important control on the evolution of Arctic coastlines. The spatial and temporal variations in this process have been challenging to resolve with conventional sampling using sparse arrays of moorings or buoys. We demonstrate a novel method for persistent observation of wave‐ice interactions using distributed acoustic sensing (DAS) along existing seafloor fiber optic telecommunications cables. DAS measurements span a 36‐km cross‐shore cable on the Beaufort Shelf from Oliktok Point, Alaska. DAS optical sensing of fiber strain‐rate provides a proxy for seafloor pressure, which we calibrate with wave buoy measurements during the ice‐free season (August 2022). We apply this calibration during the ice formation season (November 2021) to obtain unprecedented resolution of variable wave attenuation rates in new, partial ice cover. The location and strength of wave attenuation serve as proxies for ice coverage and thickness, especially during rapidly evolving events.

Smith, Madison M.↗

Shock initiation of the HMX-based explosive PBX 9012: Experiments, uncertainty analysis, and unreacted equation-of-state

In this study, shock initiation experiments have been carried out on the polymer-bonded explosive PBX 9012 [nominally 90% octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazine (HMX), 10% vinylidene–hexafluoropropylene copolymer (Viton A) by weight] in order to provide calibration data for the explosive’s unreacted equation-of-state (EOS) and shock-to-detonation transition for reactive burn rate calibration. The input pressures covered the range of 1.86–4.43 GPa. This provided run-to-detonation depths ranging from > 22.3 mm for the lowest pressure shot to 4.91 mm at the highest pressure. The relative shock sensitivity of PBX 9012 is compared to other HMX-explosives in terms of the Pop-plot, showing that the studied explosive is more sensitive than other similar HMX-based counterparts (with notable exceptions). The uncertainty in the shock velocity determinations from the shock tracker measurements are also investigated, yielding new uncertainty measures in the generated Hugoniot data and run-to-detonation coordinates. Finally, the unreacted equation-of-state is determined using a linear U s – u p Mie–Grüneisen relation and the Davis reactants EOS analytical form, the latter being more suited for reactive burn modeling.

36 MATERIALS SCIENCE↗

Field Results from New Tensor Borehole Optical Fiber Strainmeter Installations in Oklahoma and Utah

The time evolving strain field contains a wealth of information that can be used to interpret subsurface behavior. For example, injecting or removing fluids from reservoirs or aquifers causes deformation that can be used as a diagnostic signal in some cases, while it can interfere with geodetic interpretations in other cases. We've previously demonstrated the feasibility of measuring the strain tensor at a depth of 30m caused by injection into a reservoir at 530m. The observed strain signals were interpreted using four independent analytic and numerical methods that resulted in estimates of the poroelastic properties and geometry of the reservoir that was consistent with data from well logs. However, studies like these are only possible if these deformations can be reliably measured. Years of lab and field work has culminated in the development of a novel borehole strainmeter capable of resolving multiple components of strain using embedded optical fibers configured as Michelson interferometers. It features four horizontal gauges separated by 45° to resolve the horizontal strain tensor as well as a vertical strain gauge and a sixth null component for state-of-health monitoring. The downhole sensing package also includes an open pipe through its center for grout circulation during single-trip deployments and a fully welded stainless steel exterior for robustness and longevity. These instruments have a resolution of 2x10-13 strain that can easily measure the solid earth tides. Preliminary data are available from four strainmeters in shale at our Oklahoma site and four in compacted sand and gravel in Utah. These are deployed from 40-60m, except one of the strainmeters in Oklahoma is deployed at 500m. The data include strains from the initial grout curing, comparisons to predicted earth tide models and in-situ calibration results, barometric pressure admittances and spectral analyses as well as signals from underground injections and surface waves from teleseismic events. Preliminary analyses indicate behavior consistent with other strainmeter deployments, and comparison to data from a Gladwin strainmeter at the Oklahoma site validate the performance of the new design. Analyses from a suite of six well tests at the Oklahoma site show for the first time how the strain tensor field varies with location during well testing.

DeWolf, Scott↗

Post-operative cranial pressure monitoring system

System for monitoring of fluidic pressures in cranial cavity uses a miniaturized pressure sensing transducer, combined with suitable amplification means, a meter with scale calibrated in terms of pressures between minus 100 and plus 900 millimeters of water, and a miniaturized chart recorder covering similar range of pressures.

Fager, C. A., Jr.↗

An aneroid pressure sensor for constant-level balloons

The pressure sensor for the Tropical Wind Energy conversion and Reference Level Experiment (TWERLE) is described. Key design features of the sensor are: capacitive coupling, reference at midrange, up-down counting, passive oven, storage at flight pressure and prelaunch calibration. Sensor specifications are given which are based on the production results of 440 units. Drift, as estimated from simulated life tests, is 1 mb per 6 months. The overall weight of the sensor, including thermal package, is 180 g.

Levanon, N.↗

A numerical study of the NOL large-scale test

The large-scale gap test was modeled numerically using the reactive hydrodynamics code 2DE with forest fire burn rates. The model gives good agreement between calculated and experimental critical gap values. The calibration of peak pressure in the gap versus gap length is obtained from these calculations, and is in good agreement with the published experiment curve. The two dimensional nature of the gap test is evident from the curvature of the shock wave in the gap and test sample, and from the observed distance of run to detonation in the test samples.

Bowan, A. L.↗

Servo Controlled Variable Pressure Modification to Space Shuttle Hydraulic Pump

Engineering drawings show modifications made to the constant pressure control of the model AP27V-7 hydraulic pump to an electrically controlled variable pressure setting compensator. A hanger position indicator was included for continuously monitoring hanger angle. A simplex servo driver was furnished for controlling the pressure setting servovalve. Calibration of the rotary variable displacement transducer is described as well as pump performance and response characteristics.

Kouns, H. H.↗

Continuous inline blending of antimisting kerosene

A continuous inline blender was developed to blend polymer slurries with a stream of jet A fuel. The viscosity of the slurries ranged widely. The key element of the blender was a static mixer placed immediately downstream of the slurry injection point. A positive displacement gear pump for jet A was employed, and a progressive cavity rotary screw pump was used for slurry pumping. Turbine flow meters were employed for jet A metering while the slurry flow rate was calibrated against the pressure drop in the injection tube. While using one of the FM-9 variant slurries, a provision was made for a time delay between the addition of slurry and the addition of amine sequentially into the jet A stream.

Parikh, P.↗

Application of laser Doppler velocimeter to chemical vapor laser system

A laser Doppler velocimeter (LDV) system was used to measure iodide vapor flow fields inside two different-sized tubes. Typical velocity profiles across the laser tubes were obtained with an estimated +/-1 percent bias and +/-0.3 to 0.5 percent random uncertainty in the mean values and +/-2.5 percent random uncertainty in the turbulence-intensity values. Centerline velocities and turbulence intensities for various longitudinal locations ranged from 13 to 17.5 m/sec and 6 to 20 percent, respectively. In view of these findings, the effects of turbulence should be considered for flow field modeling. The LDV system provided calibration data for pressure and mass flow systems used routinely to monitor the research laser gas flow velocity.

Gartrell, Luther R.↗

Porting and Testing NPOESS CrIMSS EDR Algorithms

As a part of the National Polar-orbiting Operational Environmental Satellite System (NPOESS) and the NPOESS Preparatory Project (NPP), the instruments Cross-track Infrared Sounder (CrIS) and Advanced Technology Microwave Sounder (ATMS) make up the Cross-track Infrared and Microwave Sounder Suite (CrIMSS). CrIMSS will primarily provide global temperature, moisture, and pressure profiles and calibrated radiances [1]. In preparation for the NPOESS/NPP launch, porting and testing of the CrIMSS Environmental Data Record (EDR) algorithms need to be performed.

Kizer, Susan↗

Computational Simulations of the NASA Langley HyMETS Arc-Jet Facility

The Hypersonic Materials Environmental Test System (HyMETS) arc-jet facility located at the NASA Langley Research Center in Hampton, Virginia, is primarily used for the research, development, and evaluation of high-temperature thermal protection systems for hypersonic vehicles and reentry systems. In order to improve testing capabilities and knowledge of the test article environment, an effort is underway to computationally simulate the flow-field using computational fluid dynamics (CFD). A detailed three-dimensional model of the arc-jet nozzle and free-jet portion of the flow-field has been developed and compared to calibration probe Pitot pressure and stagnation-point heat flux for three test conditions at low, medium, and high enthalpy. The CFD model takes into account uniform pressure and non-uniform enthalpy profiles at the nozzle inlet as well as catalytic recombination efficiency effects at the probe surface. Comparing the CFD results and test data indicates an effectively fully-catalytic copper surface on the heat flux probe of about 10% efficiency and a 2-3 kpa pressure drop from the arc heater bore, where the pressure is measured, to the plenum section, prior to the nozzle. With these assumptions, the CFD results are well within the uncertainty of the stagnation pressure and heat flux measurements. The conditions at the nozzle exit were also compared with radial and axial velocimetry. This simulation capability will be used to evaluate various three-dimensional models that are tested in the HyMETS facility. An end-to-end aerothermal and thermal simulation of HyMETS test articles will follow this work to provide a better understanding of the test environment, test results, and to aid in test planning. Additional flow-field diagnostic measurements will also be considered to improve the modeling capability.

Brune, A. J.↗

A distributed processing high data rate multiport wind-tunnel pressure measurement system

A multiport pressure measurement system has been developed for the high data rates and the in situ calibration of electronically scanned pressure (ESP) sensors. The system employs a stand-alone microcomputer, connected to a host computer, for data acquisition and preprocessing. The host computer provides several operational modes. Before each run the in situ calibration of each sensor is automatically performed. Using up to a maximum of 14 data acquisition and control units (DACU's), the system may be expanded from 16 to 10,752 pressure ports. Each DACU can make 20,000 measurements per second, average data, and perform statistical analyses before transferring data to the central unit. The system may be introduced into existing facilities and requires little user orientation.

Juanarena, D.↗

Update on results of SPRE testing at NASA

The space power research engine (SPRE I), a free-piston Stirling engine with a linear alternator, was tested as a candidate for high-capacity space power. A portion of the test data from the SPRE I, essentially in its baseline configuration while operating with helium at heat exchanger metal temperature ratios ranging from 1.6 to 2.4 and mean cycle pressures of 7.5 and 15.0 Mpa, are presented. HFAST computer code predictions are presented for comparison. The measured results at 7.5 and 15 MPa, from the first day, from the first day of testing, at temperature ratios from 1.6 to 2.0 agreed fairly well with the HFAST code predictions; within -8.8 percent to +11.9 percent for PV power and -2.7 to +1.07 percentage points for PV efficiency. Measured compression-space pressure amplitude was 5.1 to 11.1 percent below predictions; although these results were within the error bands, there was poorer agreement than observed for previous tests, and the transducer calibration is suspect. All of the dynamic pressure transducer calibrations will be verified before testing is resumed. Measured pressure phase angles were within -1.95 percent to +5.37 percent of the predictions, which is much closer than previously observed. The poor agreement of the measured heat flow to the heater with the code appears to be due to thermocouple degradation.

Cairelli, James E.↗

Saturated fluorescence measurements of the hydroxyl radical in laminar high-pressure C2H6/O2/N2 flames

Saturation of a transition of the OH molecule in high-pressure flames is demonstrated by obtaining saturation curves in C2H6/O2/N2 laminar flames at 1, 6.1, 9.2, and 12.3 atm. Quantitative fluorescence measurements of OH number density at pressures to 12.3 atm are presented. To assess the efficacy of the balanced cross-rate model for high-pressure flames, laser-saturated fluorescence measurements, which were calibrated in an atmospheric-pressure flame, are compared with absorption measurements at 3.1 and 6.1 atm. At 3.1 atm the absorption and fluorescence measurements compare well. At 6.1 atm, however, the concentrations given by lasre-saturated fluorescence are about 25 percent lower than the absorption values, indicating some depletion of the laser-coupled levels beyond that at atmospheric pressure. By using a reasonable estimate for the finite sensitivity to quenching, it is anticipated that fluorescence measurements that are calibrated at 1 atm can be applied to flames at about 10 atm with absolute errors within +/- 50 percent.

Carter, Campbell D.↗