Search NASA⌕ Search

SEARCH · Search NASA

Results for “pressure drop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A computational investigation of high-flux, plate-and-frame membrane modules for industrial carbon capture

In this work, we study the application of membrane-based separation systems for carbon capture, considering plate-and-frame membrane modules. The successful deployment of membrane CO 2 capture system relies on high-performing membranes as well as effective membrane modules that can fully exploit the developed membranes. A plate-and-frame membrane module is especially attractive for CO 2 capture from industrial flue gas due to its lower pressure drop compared to its counterparts such as spiral wound modules and hollow fiber modules. To design better plate-and-frame modules, we investigate their basic unit - a single membrane stack through a combination of computational modeling and experimental investigations. The modeling approach is based on Computational Fluid Dynamics (CFD) to represent a multiphysics problem, including the fluid flow and diffusion processes within a membrane module. We use experimental data collected under different operating conditions to validate the CFD model. Numerical results suggest a good agreement between experiments and model outputs for the CO 2 recovery, CO 2 mole fraction in the retentate and permeate, and stage-cut. The CFD model is able to predict accurately the flow behavior, providing valuable insights on the effects of fluid dynamics on mass transfer of CO 2 . We also carry out a sensitivity analysis to identify the effect of key parameters on the CO 2 recovery and the CO 2 purity of the outlet streams.

CFD simulation↗

One-dimensional, transient modeling of a fixed-bed regenerator as a replacement for recuperators in supercritical CO 2 power cycles

Fixed-bed regenerators may be a low cost alternative to recuperators for supercritical CO 2 power cycles. However, the transient nature of regenerators operating in sCO 2 power cycles has not been previously characterized. This study details a one-dimensional, transient model of a fixed-bed regenerator that captures phenomena such as local fluid properties and heat transfer coefficients, entrained fluid heat capacity, and the effects of conservation of mass during process switching. The model is validated with experimental results of a 10 kWth regenerator. This comparison shows that the model predicts temperature as a function of both time and space exceptionally well. The model predicts effectiveness, heat transfer, and discharge temperatures within 5%, and predicts pressure drop and fluid carryover within 10%. This model could be used in future studies to simulate regenerators within a supercritical CO 2 power cycle.

30 DIRECT ENERGY CONVERSION↗

Flow regime and Reynolds number variation effects on the mixing behavior of parallel flows

The hydraulic single-phase mixing of three parallel rectangular channels is experimentally investigated at various Reynolds numbers (Re) and flow regime combinations. Particle Image Velocimetry results for seven mixing cases are presented and discussed with varying Re combinations ranging from 1,824 to 20,844. While all cases result in the same Re ratio of ~0.69 between the inner and outer flows, two cases represent multi-regime mixing with the inner-outer regime pair of laminar-transitional and transitional-turbulent, while the other 5 cases are all characteristic of turbulent mixing with varying levels of turbulence. The outer channels initially share characteristics with a backward facing step. The center channel is found to initially behave like a slot jet, but then sees a significant increase in velocity decay. This inner flow velocity decay increased dramatically in the laminar-transitional mixing case, whose centerline velocity decay was ~6 times larger than the decay in the turbulent mixing cases. Second order statistics revealed a consistent mixing layer thickness of ~0.1 hydraulic diameters for all the cases but showed more intense shearing in the multi-regime mixing cases. The combined point and thereby the mixing layer length is determined using centerline velocity decay profiles, which show a much more aggressive mixing in multi-regime flows. Multi-regime mixing demonstrated superior characteristics relative to turbulent mixing due to a more dramatic velocity decay in the inner flow and a shorter mixing length. The contributions of this work include communicating the benefits of multi-regime mixing and providing detailed characterization efforts that can serve future efforts for validating computational models. Here this research also lays the groundwork for future studies aimed at achieving high levels of mixing without a severe penalty in pressure drop.

42 ENGINEERING↗

MHD flow in liquid metal blankets: Major design issues, MHD guidelines and numerical analysis

The design of breeding blankets represents the major challenge for fusion reactor engineering because of performance requirements and severe operating conditions in terms of heat load and neutron flux. Liquid metal alloys such as lead-lithium, due to their lithium content, can be used to breed tritium, one of the plasma fuel components, and owing to their high thermal conductivity, they may serve as coolants. On the other hand, there are technical issues related to the fact that the liquid metals are electrically conducting and interact with the plasma-confining magnetic field. Induced electric currents and generated electromagnetic forces affect velocity and pressure distribution in the blankets. Magnetohydrodynamic (MHD) flows for fusion applications have been often investigated in simplified geometries, such as pipes, ducts, bends, with focus on their fundamental features. These analyses are essential, since results remain valid as background for the development of blanket designs, even when a concept is dismissed. However, the conceptual study of fusion blankets requires to take into account the global multiple effects, that arise when the full system is considered. Progress made in fusion-related MHD research results from combined numerical and experimental activities. In this paper we review and summarize features of 2D and 3D MHD flows that are typical in liquid metal blankets, together with available correlations for MHD pressure losses. This knowledge can provide simple design MHD guidelines that support a preliminary estimate of MHD effects in a blanket concept, in terms of pressure drop and flow distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation of tritium transport in a gas-liquid contactor CFD simulation of tritium extraction from lead-lithium in ANSYS fluent

Modifications to the Computational Fluid Dynamic (CFD) software ANSYS Fluent were done to quantify and characterize tritium transport in Gas-Liquid Contactors (GLCs). A double-slit, Ergun-like equation was employed for the porous media model, with Ergun coefficients validated with Sulzer’s Sulcol software. Tritium transport from PbLi within the GLC was verified against analytical models. The geometry of the CFD model was based on the MELODIE GLC experiment. The hydrodynamic CFD pressure drop results align well with SulCol estimations and fall between the predictions of the analytical Delft-Olujic and Billet & Schultes models. In terms of mass transfer efficiency, traditional mass transfer models showed a significant deviation from experimental results when using varying values of H solubility in PbLi. A saturation phenomenon occurred when utilizing high solubility values for hydrogen in PbLi. In conclusion, a modified film theory mass transfer coefficient, incorporating either the Delft-Olujic or Billet & Schultes wettability model, yielded CFD-predicted extraction efficiencies that closely matched experimental measurements.

70 - PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feasibility study for test rig assessments of fish passage conditions in a Kaplan turbine

The assessment of fish passage conditions in hydroelectric turbines consists of identifying and quantifying physical magnitudes leading to increased risks of injury of fish passing through turbines in operation. Such assessments are usually carried out either with the use of computer-based methods during design or with field testing of live fish and sensors passing through prototypes. A method in between consists of test rig experimentation, which is critical for testing fish-focused design concepts and offers the opportunity for implementing the most effective design measures for improved fish survivability. However, fish-related assessments in test rigs are not sufficiently documented for industrial applications. This work presents the main findings of an experimental campaign to quantify fish-related hydraulic magnitudes in a physical model of a Kaplan turbine in a commercial test rig. Two operating conditions were tested by releasing miniaturized autonomous sensor devices (termed Sensor Fish Mini) at the turbine intake flow, passing them through the runner in motion and recovering them at the draft tube exit. During passage, time series of acceleration, absolute pressure and rotational velocity were recorded. The recordings were then interpreted to determine the magnitude and likely location of hydraulic stressors hazardous to fish. The statistical tests on the reported measurements indicated that low pressure, collisions on the runner and rotations in the draft tube were not different between the two tested operating points. On the other hand, pressure drop and collision rates on the distributor differed considerably as a function of net head. The outcomes of this investigation showed that test rig evaluations of fish-related properties with Sensor Fish Mini can contribute to an evidence-based development of turbine geometries designed for providing safer passage conditions. Future work will investigate the scaling of test rig measurements to hydraulically equivalent magnitudes in the prototype and their biological consequences.

13 HYDRO ENERGY↗

Experimental results of a magnetically coupled piezoelectric actuator to relieve microchannel heat exchanger maldistribution

Refrigerant maldistribution is a common issue in microchannel heat exchangers. Refrigerant maldistribution can have significant negative effects on the heat transfer performance and increase the pressure drop, leading to increased superheat temperature at the outlet and increased compressor work, lowering system efficiency. In this work, a novel piezoelectric-driven magnetic actuator (PEDMA) was fabricated and inserted into the inlet header of the microchannel evaporator, with the goal of improving the non-uniformity of the flow distribution by regulating the flow in the header to the microchannels. Two prototype PEDMA designs were tested and showed significant impact on the refrigerant flow in the region of actuation. In the first design, the experimental data showed superheat reductions up to 9 °C when the individual channel temperatures were measured. The second design redistributed the refrigerant such that a 1% increase in capacity was calculated for the whole heat exchanger without significantly impacting the heating efficiency. The experimental results demonstrate the successful operation of the PEDMA devices and represent a new method of active flow distribution control which is based on a simple design with minimal additional energy consumption, and which can be inserted into microchannel heat exchanger headers to potentially relieve the refrigerant maldistribution.

42 ENGINEERING↗

Numerical analysis of air dehumidification through electrospray-enhanced vortical flow cyclone separator

The dehumidification of air is a highly energy-intensive process, typically requiring vapor compression systems to cool the air significantly below its dew point temperature. Here, this study numerically investigates air dehumidification achieved by electrostatic and dielectrophoresis forces in a converging duct and centrifugal principles in cyclone separators. An electrospray was employed to energize water droplets, which then captured water vapor via dielectrophoresis. A novelty of the present study is the inclusion of a cyclone separator positioned downstream of the electrospray. This combination increased the dehumidification efficiency and controlled the flow of the condensate. By integrating electrospray technology and applying an electric field, this study examines the impact of particle separation efficiency, pressure drops, and cyclone performance on air dehumidification. The control parameters for air dehumidification were investigated. Three cyclones were modelled for airflow rates of 5 cubic feet per minute [cfm] (0.0024 m 3 /s), 38 cfm (0.0179 m 3 /s), and 200 cfm (0.094 m 3 /s). The results indicated air dehumidification was up to 5.7 % under environmental conditions, similar to those used to validate the CFD model. The degree of air dehumidification was primarily influenced by the electric charge acquired by the water droplets, their flight trajectory, and the vorticity intensity within the cyclone. Air dehumidification could increase by up to 13 % by increasing the number of droplets injected into the air stream, the flight time, and the electrical charge. The breakdown electric field strength threshold near the electrospray was a limiting factor for further enhancing dehumidification performance. This study examines the optimization of an electro-assisted dehumidification system that includes cyclone-based droplet separation through numerical analysis. The results provide insights into the design of energy-efficient air treatment technologies.

42 ENGINEERING↗

Development of an innovative process for post-combustion CO 2 capture to produce high-value NaHCO 3 nanomaterials

An innovative post-combustion process using aqueous sodium glycinates solutions (SGS) for CO 2 capture from a split flue gas stream emitted from the 600 MWe coal power plant, used in the Wolverine Clean Energy Venture (WCEV) project, was developed in Aspen Plus v.10. The flue gas flow rate used in the process was 12.43 kg/s (at 353.15 K and 101.33 kPa) and contained 0.0023 and 13.33 mol% of SO 2 and CO 2 , respectively. The overall process includes 5 main units designed to remove all SO 2 and capture more than 90 mol% of CO 2 in the flue gas stream, while producing high-value, salable sodium bicarbonate (NaHCO 3 ) nanomaterials to offset the total process costs. The hydraulics, mass transfer characteristics, and process performance obtained using Aspen Plus were discussed. Also, the capital expenditure (CAPEX), operating expenditure (OPEX), and Levelized cost of CO 2 capture (LCOC) were calculated to assess the feasibility of this process. Further, the hydraulics in the SO 2 washing and CO 2 capture units showed a pressure drop of 12 and 1 kPa, respectively, and the behaviors of the liquid holdup and normalized packing specific wetted surface area were similar in both units. The gas-side mass transfer coefficients were orders of magnitude greater than the liquid-side mass transfer coefficients. The process was able to capture 2.352 kg/s of CO 2 and produce 4.486 kg/s of valuable NaHCO 3 nanomaterials. Also, the calculated CAPEX, OPEX, and LCOC of the process for a 30-year plant lifetime were ($\$ $4,450,552), (233.00 $\$ $/h) and (35.49 $\$ $/ton of CO 2 captured), respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-scale dynamic modeling and validation of radial flow fixed bed contactors for post-combustion CO 2 capture using bench scale and pilot plant data

Here, in this work, a multi-scale model of a radial flow fixed bed contactor packed with a carbon sorbent is developed and validated with laboratory-scale and pilot plant scale dynamic data. For the lab scale system, the model results were compared with low, medium and high gas and sweep flowrates, yielding root mean square error (RMSE) of 0.80, 0.63, 0.96 CO 2 mol%, respectively, for the outlet CO 2 concentration profile considering the entire A-D cycle. For the bed outer temperature profile, maximum RMSE was found to be 5.5 °C considering all flowrates and entire A-D cycles. An experimental campaign was developed and applied to a pilot plant at Technology Center Mongstad (TCM), Norway. Approaches were developed for pre-processing of data including consideration of the effect of gas mixing, measurement delay, and determination of cyclic steady-state conditions. Considering profiles during A-D cycles for all test runs, it was found that the maximum RMSE for pressure drop, temperature for the outer section of the bed, temperature for the middle section of the bed, and outlet CO 2 concentration profile remained less than 1.5 mbar, 3.5 °C, 2.8 °C, and 1.3 CO 2 mol%, respectively. The validated model was used to perform sensitivity studies on several key design operating variables for the adsorption-desorption cycle. It was found that the flow rate and concentration of flue gas have dominant nonlinear effects on the breakthrough time while the desorption time was strongly affected by the sweep gas flowrate for the specific sorbent being evaluated in this study.

20 FOSSIL-FUELED POWER PLANTS↗

Using Thermodynamic Availability to Predict the Transitional Film Reynolds Number between the Droplet and Jet Modes in Falling Liquid between Horizontal Tubes

The objective of this paper is to propose and validate a model for predicting the transitional film Reynolds number between the droplet and jet modes of falling film flows. The proposed model relies on thermodynamic availability with no fitting to mode transition data. The model directly predicts the numerical values of the transitional film Reynolds numbers at different operating conditions. The results of the model are validated against 43 experimental data points from the literature, which cover 10 working fluids and a wide range of tube geometries. The accuracy of the proposed model in predicting the validation data is -on average- more than 20 % better than that of the widely used Re = a (Ga) b and Re = a (Ga) b (S/ξ) c models. The model also achieves low computation time (less than 30 seconds for the 43 validation data points). The model presented in this paper has the potential of integration with heat transfer, mass transfer, and pressure drop models for optimizing the design and operation of falling film heat and mass exchangers.

42 ENGINEERING↗

A remarkable CHF of 345W/cm 2 is achieved in a wicked-microchannel using HFE-7100

Boiling heat transfer of dielectric fluids is a promising cooling technique for thermal management of microelectronic systems. However, the critical heat flux achievable is generally low, because of the poor thermophysical properties of these fluids. Here, to address this dilemma, we propose a new cooling concept to substantially enhance global liquid supply during phase-change process using enhanced capillary-driven force. Additionally, dedicated vapor pathways are designed among a bank of micro-pillars to facilitate vapor removal. In this work, new wicks comprised of silicon micro-pinfin arrays are explored to significantly enhance the flow boiling heat transfer performance. To examine the functionalities of this wick, experiments on HFE-7100 were carried out with mass velocities varying from 247 to 3,465 kg/m 2 s. To explore the enhancement mechanisms and to analyze the capillary-assisted flow boiling process, visualization studies were conducted. The results indicate that sustainable evaporation induced by wick microstructures and efficient liquid supply are the enhancement mechanisms compared to parallel microchannels with solid walls. It is found that the overall heat transfer coefficient is substantially increased up to 75%. Remarkably, a high critical heat flux (CHF) of approximately 345 W/cm 2 is recorded at G = 3,465 kg/m 2 s at coolant inlet temperature of ~20 °C. Equally importantly, this noticeable enhancement of CHF value is associated with drastically decreased pressure drops compared to microchannels decorated with μ-pinfin fences.

36 MATERIALS SCIENCE↗

Comparison of Shape Optimization Methods for Heat Exchanger Fins Using Computational Fluid Dynamics

Inverse design techniques are one way to leverage advances in 3D printing, artificial intelligence, and computational resources to achieve increased performance of heat exchangers. Two optimization techniques (genetic algorithm and particle swarm) and three geometry representations (binary level set, composite Bézier, and free form deformation) are used to increase the heat transfer and reduce the pressure drop of a heat exchanger fin. After running 210,810 OpenFOAM simulations, results indicate that a significant performance increase of the fin can be realized in less than 48 hrs, allowing for such a process to be integrated in traditional design processes. The best design increased the performance of the objective function, compared to the baseline rectangular geometry by 75%. A custom distributed infrastructure was built, allowing for all methods to reach 95% of the final objective values in a little over 4 hrs, handling 1674 OpenFoam simulations per hour.

42 ENGINEERING↗

Design, optimization, and validation of a triply periodic minimal surface based heat exchanger for extreme temperature applications

Heat exchanger (HX) innovation offers potential for significant improvements in energy efficiency for a host of applications including but not limited to aviation and power generation cycles. Triply Periodic Minimal Surfaces (TPMS) have received significant attention in recent years due to their incredibly high surface area density, which makes them very attractive from a heat transfer point of view. Recent efforts have largely focused on thermal-hydraulic characterization of the many available TPMS and the testing of small-scale HX prototypes. However, practical implementation remains largely unexplored, partially due to the extreme computational cost associated with accurately simulating these complex structures. In this work, we present the design, simulation, and optimization of a TPMS-HX for high temperature (900 °C) and pressure (25 MPa) applications. Detailed analysis of HX sub-sections is conducted to define the smallest repeatable section which may be used to characterize the thermal-hydraulic performance of the entire HX, enabling rapid design and iteration with significantly reduced computational cost. Compared to preliminary results for a water-to-water experiment, calibrated heat transfer and pressure drop predictions were within ±5 % and ±10 %, respectively. Optimization results show a 10x increase in volumetric power density over the initial design, which is verified against a parametric exhaustive search of the HX design space. Furthermore, it was found that reducing the unit cell hydraulic diameter cell plays the largest role in increasing heat transfer, increasing the surface area density and enabling a more compact and efficient HX.

42 ENGINEERING↗

Experimental characterization of a triply periodic minimal surface PCM-to-air thermal energy storage device

Here, the expansion of energy production has intensified research into thermal energy storage (TES) to manage variability and improve system efficiency. Heat exchanger design is critical to achieving high power densities in TES systems. This study presents a high-surface-area phase change material (PCM)-to-air heat exchanger fabricated via resin-based stereolithography with a novel gyroid-based geometry tailored for enhanced performance. Material properties of the commercial PCM and resin were characterized using analytical techniques. A controlled air loop was used to evaluate heat transfer and pressure drop at various flow rates and inlet temperatures. Results show a strong dependence on the inlet temperature difference (ΔT) relative to the PCM melting point. During charging at the highest flow rate, increasing the inlet air temperature from ΔT = 5 °C to 20 °C above the melting point increased the average heat transfer rate by 187%. During discharging, decreasing the inlet temperature by the same ΔT below the melting point led to a 232% increase. Notably, the high-surface-area design enabled nearly symmetric charging and discharging behavior, a novel result for PCM-based TES systems which are often restricted by natural convection and other effects. The overall heat transfer coefficient was calculated and compared to values from standard design correlations. The maximum thermal effectiveness reached 95% at ΔT = 20 °C and a moderate flow rate of 34 m 3 /h. Peak coefficients of performance (COP) of 7 during charging and 6.4 during discharging were observed at ΔT = 20 °C and a low flow rate of 20 m 3 /h. These results demonstrate the viability of additively manufactured geometries for advanced TES applications.

25 ENERGY STORAGE↗

Thermodynamic parametric analysis of refueling heavy-duty hydrogen fuel-cell electric vehicles

Reliable design and safe operation of heavy-duty hydrogen refueling stations are essential for the successful deployment of heavy-duty fuel cell electric vehicles (FCEVs). Fueling heavy-duty FCEVs is different from light-duty vehicles in terms of the dispensed hydrogen quantities and fueling rates, requiring tailored fueling station design for each vehicle class. In particular, the selection and design of the onboard hydrogen storage tank system and the fueling performance requirements influence the safe design of hydrogen fueling stations. A thermodynamic modeling and analysis are performed to evaluate the impact of various fueling parameters and boundary conditions on the fueling performance of heavy-duty FCEVs. Here, we studied the effect of dispenser pressure ramp rate and precooling temperature, initial tank temperature and pressure, ambient temperature, and onboard storage design parameters, such as onboard storage pipe diameter and length, on the fueling rate and final vehicle state-of-charge, while observing prescribed tank pressure and temperature safety limits. An important finding was the sensitivity of the temporal fueling rate profile and the final tank state of charge to the design factors impacting pressure drop between the dispenser and vehicle tank, including onboard storage pipe diameter selection, and flow coefficients of nozzle, valves, and fittings. The fueling rate profile impacts the design and cost of the hydrogen precooling unit upstream of the dispenser.

08 HYDROGEN↗

Novel geometries for air-cooled condensation of ammonia-water mixtures

An analytical and experimental investigation of air-cooled condensers for small-scale ammonia-water absorption heat pumps is presented. Conventional round-tube corrugated fin design and a novel multi-pass tube array design are considered for a condenser operating at severe ambient conditions within a compact footprint. Segmental heat and mass transfer models are developed to gain a deeper understanding of the characteristics of each design. Predicted heat duties are within 5% of the measured values. The limitations of correlations to predict air-side pressure drop in corrugated fins are identified. The performance of the novel multi-pass tube array condenser was comparable to that of conventional condensers, but is determined to be air-side limited throughout length of the heat exchanger. An improved multi-pass condenser design with fins for increased air-side area is proposed using the insights gained from the modeling and experiments. In closing this design meets the heat duty requirements at severe ambient conditions, while decreasing the size of the heat exchanger by 33%.

42 ENGINEERING↗

A Performance analysis of the Claridge-Culp-Liu dehumidification process: A novel approach for drying moist air based on membrane separation, vacuum compression and sub-atmospheric condensation

This article covers a basic model for analyzing the performance of the Claridge-Culp-Liu dehumidification process. The fundamental process efficiency limit for dehumidification is close to COP Carnot , but for the eight dehumidification cases examined, the limiting or ideal energy use required is 26% to 56% that of a Carnot condensing system as shown in an earlier paper. The model presented in this paper is used to show the membrane system performance reduction caused by finite membrane area, finite water vapor permeance, non-zero air permeance, non-zero system air pressure drop, non-ideal compressors, vacuum pumps, and condensers. The performance of a “conservative” membrane system based on the use of existing components is computed for eight specific conditions along with that of a “target” system that assumes expected component performance after additional future component development. The “conservative” membrane system would use 36% to 66% as much energy as a system with a COP=7 chiller to produce the same dehumidification for the eight cases examined while the “target” system would use 15% to 40% the energy of a system with a COP=7 chiller. In addition to the significant energy reduction over conventional technology, the membrane system offers the advantages of: 1) no HFC refrigerant use; 2) direct isothermal control over humidity ratio setpoint; 3) maximum capacity occurs at design conditions; and 4) system generates pure water extracted from air as a by-product.

42 ENGINEERING↗