Search NASA⌕ Search

SEARCH · Search NASA

Results for “protection system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Evaluation of coated columbium alloy heat shields for space shuttle thermal protection system application. Volume 3, phase 3: Full size TPS evaluation

The thermal protection system (TPS), designed for incorporation with space shuttle orbiter systems, consists of one primary heat shield thermally and structurally isolated from the test fixture by eight peripheral guard panels, all encompassing an area of approximately 12 sq ft. TPS components include tee-stiffened Cb 752/R-512E heat shields, bi-metallic support posts, panel retainers, and high temperature insulation blankets. The vehicle primary structure was simulated by a titanium skin, frames, and stiffeners. Test procedures, manufacturing processes, and methods of analysis are fully documented. For Vol. 1, see N72-30948; for Vol. 2, see N74-15660.

Baer, J. W.↗

An assessment of the impact of transition on advanced winged entry vehicle thermal protection system mass

This study examines the impact of turbulent heating on thermal protection system (TPS) mass for advanced winged entry vehicles. Four basic systems are considered: insulative, metallic hot structures, metallic standoff, and hybrid systems. TPS sizings are performed using entry trajectories tailored specifically to the characteristics of each TPS concept under consideration. Comparisons are made between systems previously sized under the assumption of all laminar heating and those sized using a baseline estimate of transition and turbulent heating. The relative effect of different transition criteria on TPS mass requirements is also examined. Also investigated are entry trajectories tailored to alleviate turbulent heating. Results indicate the significant impact of turbulent heating on TPS mass and demonstrate the importance of both accurate transition criteria and entry trajectory tailoring.

Wurster, K. E.↗

An Assessment of Alternate Thermal Protection Systems for the Space Shuttle Orbiter: Executive Summary - Volume 1

Alternate thermal protection system (TPS) concepts to the Space Shuttle Orbiter were assessed. Metallic, ablator, and carbon-carbon concepts which are the result of some previous design, manufacturing and testing effort were considered. Emphasis was placed on improved TPS durability, which could potentially reduce life cycle costs and improve Orbiter operational characteristics. Integrated concept/orbiter point designs were generated and analyzed on the basis of Shuttle design environments and criteria. A merit function evaluation methodology based on mission impact, life cycle costs, and risk was developed to compare the candidate concepts and to identify the best alternate. Voids and deficiencies in the technology were identified, along with recommended activities to overcome them. Finally, programmatic plans, including ROM costs and schedules, were developed for all activities required to bring the selected alternate system up to operational readiness.

Hays, D.↗

Assessment of alternate thermal protection systems for the Space Shuttle Orbiter

Technical aspects of the alternate thermal protection system (TPS) study for the Shuttle Orbiter are reviewed, and a status report on alternate TPS technology developments is presented. Mission impact, life cycle costs and risks, and selected candidate concepts are identified. The best system would consist of mechanically attached metallic and carbon-carbon TPS concepts employing a titanium multiwall prepackaged concept at temperatures below 1000 F, a superalloy honeycomb prepackaged concept at temperatures between 1000-1800 F, and an advanced carbon-carbon multipost standoff concept above 1800 F. Alternative concepts offer significant improvements in durability and are mass competitive with current ceramic tile reusable surface insulation.

Kelly, H. N.↗

Orbiter thermal protection system

The major material and design challenges associated with the orbiter thermal protection system (TPS), the various TPS materials that are used, the different design approaches associated with each of the materials, and the performance during the flight test program are described. The first five flights of the Orbiter Columbia and the initial flight of the Orbiter Challenger provided the data necessary to verify the TPS thermal performance, structural integrity, and reusability. The flight performance characteristics of each TPS material are discussed, based on postflight inspections and postflight interpretation of the flight instrumentation data. Flights to date indicate that the thermal and structural design requirements for the orbiter TPS are met and that the overall performance is outstanding.

Dotts, R. L.↗

Thermal certification tests of Orbiter Thermal Protection System tiles coated with KSC coating slurries

Thermal tests of Orbiter thermal protection system (TPS) tiles, which were coated with borosilicate glass slurries fabricated at Kennedy Space Center (KSC), were performed in the Radiant Heat Test Facility and the Atmospheric Reentry Materials & Structures Evaluation Facility at Johnson Space Center to verify tile coating integrity after exposure to multiple entry simulation cycles in both radiant and convective heating environments. Eight high temperature reusable surface insulation (HRSI) tiles and six low temperature reusable surface insulation (LRSI) tiles were subjected to 25 cycles of radiant heat at peaked surface temperatures of 2300 F and 1200 F, respectively. For the LRSI tiles, an additional cycle at peaked surface temperature of 2100 F was performed. There was no coating crack on any of the HRSI specimens. However, there were eight small coating cracks (less than 2 inches long) on two of the six LRSI tiles on the 26th cycle. There was practically no change on the surface reflectivity, physical dimensions, or weight of any of the test specimens. There was no observable thermal-chemical degradation of the coating either. For the convective heat test, eight HRSI tiles were tested for five cycles at a surface temperature of 2300 F. There was no thermal-induced coating crack on any of the test specimens, almost no change on the surface reflectivity, and no observable thermal-chemical degradation with an exception of minor slumping of the coating under painted TPS identification numbers. The tests demonstrated that KSC's TPS slurries and coating processes meet the Orbiter's thermal specification requirements.

Milhoan, James D.↗

Evaluation of Grounding Impedance of a Complex Lightning Protective System Using Earth Ground Clamp Measurements and ATP Modeling

A new Lightning Protection System (LPS) was designed and built at Launch Complex 39B (LC39B), at the Kennedy Space Center (KSC), Florida, which consists of a catenary wire system (at a height of about 181 meters above ground level) supported by three insulators installed atop three towers in a triangular configuration. A total of nine downconductors (each about 250 meters long, on average) are connected to the catenary wire system. Each of the nine downconductors is connected to a 7.62-meter radius circular counterpoise conductor with six equally spaced 6-meter long vertical grounding rods. Grounding requirements at LC39B call for all underground and above ground metallic piping, enclosures, raceways, and cable trays, within 7.62 meters of the counterpoise, to be bounded to the counterpoise, which results in a complex interconnected grounding system, given the many metallic piping, raceways, and cable trays that run in multiple direction around LC39B. The complexity of this grounding system makes the fall of potential method, which uses multiple metallic rods or stakes, unsuitable for measuring the grounding impedances of the downconductors. To calculate the downconductors grounding impedance, an Earth Ground Clamp (a stakeless grounding resistance measuring device) and a LPS Alternative Transient Program (ATP) model are used. The Earth Ground Clamp is used to measure the loop impedance plus the grounding impedance of each downconductor and the ATP model is used to calculate the loop impedance of each downconductor circuit. The grounding impedance of the downconductors is then calculated by subtracting the ATP calculated loop impedances from the Earth Ground Clamp measurements.

Mata, Carlos T.↗

Evaluation of Alternative Altitude Scaling Methods for Thermal Ice Protection System in NASA Icing Research Tunnel

A test was conducted at NASA Icing Research Tunnel to evaluate altitude scaling methods for thermal ice protection system. Two scaling methods based on Weber number were compared against a method based on the Reynolds number. The results generally agreed with the previous set of tests conducted in NRCC Altitude Icing Wind Tunnel. The Weber number based scaling methods resulted in smaller runback ice mass than the Reynolds number based scaling method. The ice accretions from the Weber number based scaling method also formed farther upstream. However there were large differences in the accreted ice mass between the two Weber number based scaling methods. The difference became greater when the speed was increased. This indicated that there may be some Reynolds number effects that isnt fully accounted for and warrants further study.

thermal scaling↗

Heatshield for Extreme Entry Environment Technology (HEEET) Thermal Protection System (TPS)

Over the last 5 years, the Heatshield for Extreme Entry Environment Technology (HEEET) project has been working to mature a 3-D Woven Thermal Protection System (TPS) to Technical Readiness Level (TRL) 6 to support future NASA missions to destinations with extreme entry environments such as Venus, Saturn, Uranus, Neptune and high speed sample return missions to Earth. A key aspect of the project has been the building and testing of a 1-meter base diameter Engineering Test Unit (ETU) representative of what could be used for a Saturn probe. This paper provides a high level overview of the HEEET project including manufacturing and testing of the ETU which has been subjected to mission relevant thermal and mechanical loads, to verify structural models, establish system capability and verify manufacturing workmanship.

TPS↗

MER surface fault protection system

The Mars Exploration Rovers surface fault protection design was influenced by the fact that the solar-powered rovers must recharge their batteries during the day to survive the night. the rovers needed to autonomously maintain thermal stability, initiate safe and reliable communication with orbiting assets or directly to Earth, while maintaining energy balance. This paper will describe the system fault protection design for the surface phase of the mission.

system fault protection↗

Sustaining Mature Thermal Protection Systems Crucial for Future In-Situ Planetary Missions

This paper seeks to inform of the need for, and approaches to, sustaining critical thermal protection systems (TPS) for in-situ planetary missions in the coming decade. The key technologies, HEEET and PICA, are needed only for these NASA missions, will not be sustained in the absence of use, and are at risk of atrophy in the absence of mitigation.

Thermal Protection System↗

Multiscale and Multifidelity Modeling of a 3D Woven Composite Thermal Protection System

Complex three-dimensional (3D) woven composites have been considered by multiple NASA projects in recent years as a means of offering improved mechanical and thermal performance over traditional laminated composite systems. Parallel efforts have focused on developing simulation capabilities for these systems, which have traditionally and heavily relied on experimental testing to evaluate composite performance. One system is the Heatshield for Extreme Entry Environment Technology (HEEET), which is being considered for the thermal protection system on reentry spacecraft. Optical microscopy was used to characterize the blended carbon and phenolic fiber tows. A section of HEEET insulation layer was imaged with high-resolution micro-computed tomography (microCT) and segmented to separate individual tows, porous matrix, and voids. These data were used to develop multiscale thermomechanical computational models within the NASA Multiscale Analysis Tool (NASMAT). Two NASMAT modeling approaches were considered to capture the details of the 3D woven architecture: a coarse model appropriate for inclusion in multiscale structural analyses and a high-fidelity model created by downsampling the microCT data. Both elastic and thermal properties were computed and compared. The feasibility and challenges associated with modeling complex, hybrid 3D woven composites were also addressed.

NASMAT↗

In-flight rain damage tests of the shuttle thermal protection system

NASA conducted in-flight rain damage tests of the Shuttle thermal protection system (TPS). Most of the tests were conducted on an F-104 aircraft at the Dryden Flight Research Facility of NASA's Ames Research Center, although some tests were conducted by NOAA on a WP-3D aircraft off the eastern coast of southern Florida. The TPS components tested included LI900 and LI2200 tiles, advanced flexible reusable surface insulation, reinforced carbon-carbon, and an advanced tufi tile. The objective of the test was to define the damage threshold of various thermal protection materials during flight through rain. The test hardware, test technique, and results from both F-104 and WP-3D aircraft are described. Results have shown that damage can occur to the Shuttle TPS during flight in rain.

Meyer, Robert R., Jr.↗

Aerothermal performance and structural integrity of a Rene 41 thermal protection system at Mach 6.6

A flightweight panel based on a metallic thermal-protection-system concept for hypersonic and reentry vehicles was subjected repeatedly to thermal cycling by quartz-lamp radiant heating using a thermal history representative of a reentry heat pulse and to aerodynamic heating at heating rates required to sustain a surface temperature of 1089 K (1960 R). The panel consisted of a corrugated heat shield and support members of 0.05-cm (0.02-in.) thick Rene 41 of riveted construction and 5.08-cm (2-in.) thick silica fibrous insulation packages covered by Rene 41 foil and inconel screening. All tests were conducted in the Langley 8-foot high-temperature structures tunnel with the heat shield corrugations alined in the stream direction. The panel sustained 5.33 hr of intermittent radiant heating and 6.5 min of intermittent aerodynamic heating of up to 1-min duration for differential pressures up to 6.2 kPa (0.9 psi) with no apparent degradation of thermal or structural integrity, as indicated by temperature distributions and results from load deflection tests and vibration surveys of natural frequencies.

Deveikis, W. D.↗