Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulsed laser operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Analyses of Technology for Solid State Coherent Lidar

Over past few years, considerable advances have been made in the areas of the diode-pumped, eye-safe, solid state lasers and room temperature, wide bandwidth, semiconductor detectors operating in the near-infrared region. These advances have created new possibilities for the development of reliable and compact coherent lidar systems for a wide range of applications. This research effort is aimed at further developing solid state coherent lidar technology for remote sensing of atmospheric processes such as wind, turbulence and aerosol concentration. The work performed by the UAH personnel under this Delivery Order concentrated on design and analyses of laboratory experiments and measurements, and development of advanced lidar optical subsystems in support of solid state laser radar remote sensing systems which are to be designed, deployed, and used to measure atmospheric processes and constituents. Under this delivery order, a lidar breadboard system was designed and analyzed by considering the major aircraft and space operational requirements. The lidar optical system was analyzed in detail using SYNOPSIS and Code V optical design packages. The lidar optical system include a wedge scanner and the compact telescope designed by the UAH personnel. The other major optical components included in the design and analyses were: polarizing beam splitter, routing mirrors, wave plates, signal beam derotator, and lag angle compensator. This lidar system is to be used for demonstrating all the critical technologies for the development of a reliable and low-cost space-based instrument capable of measuring global wind fields. A number of laboratory experiments and measurements were performed at the NASA/MSFC Detector Characterization Facility, previously developed by the UAH personnel. These laboratory measurements include the characterization of a 2-micron InGaAs detectors suitable for use in coherent lidars and characterization of Holographic Optical Element Scanners. UAH personnel actively participated in the development of performance and operational requirements for the development of the high pulse energy transmitter laser and frequency-agile local oscillator laser, that are in-progress at NASA Langley Research Center and Jet Propulsion Laboratory.

Amzajerdian, Farzin↗

First DIII-D-West hybrid scenario similarity experiments for iter-relevant long-pulse operation

For the first time, similarity experiments between DIII-D and WEST were performed in the ITER "hybrid-like" regime during dedicated campaigns in April and May 2025. The matched parameters include elongation, triangularity, ion ∇B drift direction toward the X-point, qprofile, and core normalized physics quantities in terms of normalized pressure, normalized gyroradius, electron collisionality, ratio of ion to electron temperature, T i /T e . Core transport physics is explored with different aspect ratio (R/a) values (typically 3 at DIII-D and 5 on WEST). DIII-D explored high-beta conditions (electromagnetic effect) with low torque injection (~0 ± 0.5 N•m) using high heating power (up to 6 MW NBI and 2 MW ECRH powers), while scanning the heating mix (ion vs electron), beta, T i /T e , core radiation via controlled tungsten injection using the Laser Blow-Off system. WEST extended operation toward long-duration pulses using its actively cooled tungsten divertor, achieving dominated electron heating regimes with reduced tungsten contamination. Boron impurity injection were scanned on WEST to control edge conditions and core performance. It is found that core confinement improves-manifested by higher electron temperature, total energy content, neutron rate, and ion temperatureunder conditions of low separatrix density, consistent with previous observations [Bourdelle et al., Nucl. Fusion 63 (2023) 056021]. Conditions for Hmode access and for ion heating in electron-dominated regimes in both WEST and DIII-D will be discussed and compared. The ratio of the thermal energy confinement time (τ E ) to the volume-averaged electron-ion collisional heat exchange time (τ e-i ) is a key parameter to enhance ion heating and potentially facilitate H-mode access in electron-heated regimes. These first-of-a-kind coordinated DIII-D and WEST experiments provide a unique multi-machine dataset to validate predictive models and to optimize ITER hybrid-scenario performance under diverse core and edge conditions.

DIII-D↗

Software for Acquiring Image Data for PIV

PIV Acquisition (PIVACQ) is a computer program for acquisition of data for particle-image velocimetry (PIV). In the PIV system for which PIVACQ was developed, small particles entrained in a flow are illuminated with a sheet of light from a pulsed laser. The illuminated region is monitored by a charge-coupled-device camera that operates in conjunction with a data-acquisition system that includes a frame grabber and a counter-timer board, both installed in a single computer. The camera operates in "frame-straddle" mode where a pair of images can be obtained closely spaced in time (on the order of microseconds). The frame grabber acquires image data from the camera and stores the data in the computer memory. The counter/timer board triggers the camera and synchronizes the pulsing of the laser with acquisition of data from the camera. PIVPROC coordinates all of these functions and provides a graphical user interface, through which the user can control the PIV data-acquisition system. PIVACQ enables the user to acquire a sequence of single-exposure images, display the images, process the images, and then save the images to the computer hard drive. PIVACQ works in conjunction with the PIVPROC program which processes the images of particles into the velocity field in the illuminated plane.

Wernet, Mark P.↗

Helicopter Flight Test of 3-D Imaging Flash LIDAR Technology for Safe, Autonomous, and Precise Planetary Landing

Two flash lidars, integrated from a number of cutting-edge components from industry and NASA, are lab characterized and flight tested for determination of maximum operational range under the Autonomous Landing and Hazard Avoidance Technology (ALHAT) project (in its fourth development and field test cycle) which is seeking to develop a guidance, navigation, and control (GN&C) and sensing system based on lidar technology capable of enabling safe, precise crewed or robotic landings in challenging terrain on planetary bodies under any ambient lighting conditions. The flash lidars incorporate pioneering 3-D imaging cameras based on Indium-Gallium-Arsenide Avalanche Photo Diode (InGaAs APD) and novel micro-electronic technology for a 128 x 128 pixel array operating at 30 Hz, high pulse-energy 1.06 micrometer Nd:YAG lasers, and high performance transmitter and receiver fixed and zoom optics. The two flash lidars are characterized on the NASA-Langley Research Center (LaRC) Sensor Test Range, integrated with other portions of the ALHAT GN&C system from partner organizations into an instrument pod at NASA-JPL, integrated onto an Erickson Aircrane Helicopter at NASA-Dryden, and flight tested at the Edwards AFB Rogers dry lakebed over a field of human-made geometric hazards during the summer of 2010. Results show that the maximum operational range goal of 1 km is met and exceeded up to a value of 1.2 km. In addition, calibrated 3-D images of several hazards are acquired in real-time for later reconstruction into Digital Elevation Maps (DEM's).

Roback, Vincent↗

Lasing characteristics of InAs quantum dot laers on InP substrate

Single-stack InAs self-assembled quantum dots (QD) lasers based on InP substrate have been grown by metalorganic vapor phase epitaxy. The narrow ridge waveguide lasers lased up to 260 K in continuous wave operation, and near room temperature in pulsed mode, with wavelengths between 1.59 to 1.74 mu m.

quantum dot semiconductor laser↗

Generation of Bright Soft X-ray Laser Beams (Final Report)

The project goal was to demonstrate new compact soft x-ray lasers emitting high energy ultrashort pulses at shorter wavelengths and increased repetition rates by amplification in atomic transitions in high density laser-created plasmas. To demonstrate these lasers we developed new high power solid state lasers. The project succeeded in demonstrating the shortest wavelength compact soft x-ray laser to date, 6.85 nm wavelength, and the highest repetition rate table-top soft x-ray laser, 400 Hz. We also applied these compact soft x-ray laser sources to determine the composition of materials with nanoscale resolution using a new technique that combines soft x-ray laser ablation with mass spectrometry, and we demonstrated that these lasers are capable of acquiring nanoscale resolution holograms with picosecond time resolution. The combination of an increased pumping efficiency with increased repetition rates can yield soft x-ray laser beams with an unprecedented average power on a table-top for applications demanding a high photon flux. We have demonstrated that the efficiency of plasma-based laser-pumped soft x-ray lasers can be significantly increased by detailed pulse shaping of the pump laser using a new pulse synthesizer. Results include the demonstration of 18.9 nm wavelength laser operation at a record 400 Hz repetition rate, and the extension of repetitive gain-saturated plasma-based table-top x-ray lasers to the shortest wavelength to date, 6.85 nm. Laser amplification was also observed at wavelengths as short at 5.8 nm by isolectronic scaling in Ni-like lanthanide ions. We have also conducted simulations to explore the possibility of demonstrating gain saturated atomic x-ray lasers near the carbon K-edge, in the “carbon window” for the first time. The work conducted under this program also includes the use of compact soft x-ray lasers in applications to problems of chemical interest, such as isotopic composition mapping of micron-size uranium particles with nanoscale resolution, and nanoscale resolution depth profiling analysis of CoNCN-coated electrodes for water oxidation catalysis. We also demonstrated single-shot high resolution soft x-ray Fourier transform holography over a broad 7 µm diameter field of view with ~ 5 ps temporal resolution.

74 ATOMIC AND MOLECULAR PHYSICS↗

Aerosol and cloud sensing with the Lidar In-space Technology Experiment (LITE)

The Lidar In-space Technology Experiment (LITE) is a multi-wavelength backscatter lidar developed by NASA Langley Research Center to fly on the Space Shuttle. The LITE instrument is built around a three-wavelength ND:YAG laser and a 1-meter diameter telescope. The laser operates at 10 Hz and produces about 500 mJ per pulse at 1064 nm and 532 nm, and 150 mJ per pulse at 355 nm. The objective of the LITE program is to develop the engineering processes required for space lidar and to demonstrate applications of space-based lidar to remote sensing of the atmosphere. The LITE instrument was designed to study a wide range of cloud and aerosol phenomena. To this end, a comprehensive program of scientific investigations has been planned for the upcoming mission. Simulations of on-orbit performance show the instrument has sufficient sensitivity to detect even thin cirrus on a single-shot basis. Signal averaging provides the capability of measuring the height and structure of the planetary boundary layer, aerosols in the free troposphere, the stratospheric aerosol layer, and density profiles to an altitude of 40 km. The instrument has successfully completed a ground-test phase and is scheduled to fly on the Space Shuttle Discovery for a 9-day mission in September 1994.

Winker, D. M.↗

Absorption spectroscopy with quantum cascade lasers

Novel pulsed and cw quantum cascade distributed feedback (QC-DFB) lasers operating near lambda=8 micrometers were used for detection and quantification of trace gases in ambient air by means of sensitive absorption spectroscopy. N2O, 12CH4, 13CH4, and different isotopic species of H2O were detected. Also, a highly selective detection of ethanol vapor in air with a sensitivity of 125 parts per billion by volume (ppb) was demonstrated.

NASA Discipline Life Sciences Technologies↗

Development of the Lidar Atmospheric Sensing Experiment (LASE): An Advanced Airborne DIAL Instrument

The Lidar Atmospheric Sensing Experiment (LASE) Instrument is the first fully-engineered, autonomous Differential Absorption Lidar (DIAL) System for the measurement of water vapor in the troposphere (aerosol and cloud measurements are included). LASE uses a double-pulsed Ti:Sapphire laser for the transmitter with a 30 ns pulse length and 150 mJ/pulse. The laser beam is "seeded" to operate on a selected water vapor absorption line in the 815-nm region using a laser diode and an onboard absorption reference cell. A 40 cm diameter telescope collects the backscattered signals and directs them onto two detectors. LASE collects DIAL data at 5 Hz while onboard a NASA/Ames ER-2 aircraft flying at altitudes from 16-21 km. LASE was designed to operate autonomously within the environment and physical constraints of the ER-2 aircraft and to make water vapor profile measurements across the troposphere to better than 10% accuracy. LASE has flown 19 times during the development of the instrument and the validation of the science data. This paper describes the design, operation, and reliability of the LASE Instrument.

Moore, Alvah S., Jr.↗

Fluorine and Lithium at the Kimberley Outcrop, Gale Crater

ChemCam is an active remote sensing instrument which has operated successfully on MSL since landing in August, 2012. Its laser pulses remove dust and to profile through weathering coatings of rocks up to 7 m away. Laser-induced breakdown spectroscopy (LIBS) produces emission spectra of materials ablated from the samples in electronically excited states. As the plasma cools, elements can recombine and molecular emission lines are observed. Recent experiments have shown that some of these molecular emissions can be much brighter than the associated atomic lines, especially when halo-gens and rare earth elements are present. We observed these molecular emissions in some of the ChemCam spectra and report the first detection of chlorine and fluorine with ChemCam. It is also the first time ever that fluorine has been detected on the surface of Mars. Among all the F-bearing observations, one third are observed in the Kimberley outcrop. We will dis-cuss the potential mineralogies related to these observations as well as the related elemental correlations and propose interpretations.

Forni, O.↗

Recent Progress Made in the Development of High-Energy UV Transmitter

In this paper, the status of an all-solid-state UV converter development for ozone sensing applications is discussed. A high energy Nd:YAG laser for pumping the UV converter arrangement was recently reported. The pump is an all-solid-state, single longitudinal mode, and conductively cooled Nd:YAG laser operating at 1064 nm wavelength. Currently, this pump laser provides an output pulse energy of greater than 1J/pulse at 50 Hz PRF and a pulsewidth of 22 ns with an electrical-to-optical system efficiency of greater than 7% and a M(sup 2) value of approx. 2. The spatial profile of the output beam is a rectangular super Gaussian. This Nd:YAG pump laser has been developed to pump the nonlinear optics based UV converter arrangement to generate 320 nm and 308 nm wavelengths by means of 532 nm wavelength. Previously, this UV converter arrangement has demonstrated IR-to-UV conversion efficiency of 24% using a flash lamp pumped laser providing a round, flat top spatial profile. Recently, the UV converter was assembled and tested at NASA LaRC for pumping with the diode pumped Nd:YAG laser. With current spatial profile, the UV converter was made operational. Current efforts to maximize the nonlinear conversion efficiency by refining its spatial profile to match RISTRA OPO requirements are progressing.

Prasad, Narasimha S.↗

The development, performance, and potential application of the copper halide laser

The copper halide laser (CHL) is an efficient gas discharge laser that emits short pulses at two discrete wavelengths in the yellow and green spectral region. The laser pulse results from transitions in excited copper atoms. The CHL has produced pulses of up to 10 mJ in a double-pulsed mode at low repetition rates and has been operated at very high repetition rates (8 to over 35 kHz) in a continuously pulsed mode with a maximum average-power of 15 watts. In this paper, the development of the copper halide laser is reviewed along with a brief description of the copper laser operating principles. In the final section, a number of applications of the CHL are identified.

Pivirotto, T. J.↗

Wavemeter measurements of frequency stability of an injection seeded alexandrite laser for pressure and temperature lidar

The GSFC pressure-temperature lidar is a differential absorption lidar operating in the oxygen A band absorption region (760 to 770 nm), and utilizes two tunable pulsed alexandrite lasers. For obtaining temperature measurements with an accuracy of less than or = 1 K, it has been determined that the stability of the online laser frequency over a period of time corresponding to a set of measurements, 0.1 to 30 min, has to be better than +/- 0.002/cm. In addition, the requirements on laser spectral bandwidth and spectral purity are less than or = 0.02/cm and greater than or = 99.9 percent, respectively. Injection seeding with a stabilized AlGaAs diode laser was used to achieve the required frequency stability and spectral bandwidth. A high resolution Fizeau wavemeter was employed to determine the frequency stability of the pulsed alexandrite laser and determine its bandwidth, mode structure. We present the results of measurements of the frequency stability and the spectrum of the injection seeded alexandrite laser.

Prasad, C. R.↗

Demonstration of plasma mirror capability for the OMEGA Extended Performance laser system

A plasma mirror platform was developed for the OMEGA-EP facility to redirect beams, thus enabling more flexible experimental configurations as well as a platform that can be used in the future to improve laser contrast. The plasma mirror reflected a short pulse focusing beam at 22.5° angle of incidence onto a 12.5 μm thick Cu foil, generating Bremsstrahlung and k α x rays, and accelerating ions and relativistic electrons. By measuring these secondary sources, the plasma mirror key performance metrics of integrated reflectivity and optical quality are inferred. It is shown that for a 5 ± 2 ps, 310 J laser pulse, the plasma mirror integrated reflectivity was 62 ± 13% at an operating fluence of 1670 J cm –2 , and that the resultant short pulse driven particle acceleration and x-ray generation indicate that the on target intensity was 3.1 × 10 18 W cm –2 , which is indicative of a good post-plasma mirror interaction beam optical quality. By deriving the plasma mirror performance metrics from the secondary source scalings, it was simultaneously demonstrated that the plasma mirror is ready for adoption in short pulse particle acceleration and high energy photon generation experiments using the OMEGA-EP system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiative Transfer Through Clouds and Its Applications in Support of the Ice, Cloud, and Land Elevation Satellite-2 (ICESat-2) Mission

The Greenland and Antarctic ice sheets, which contain enough ice to raise sea level by about 7 and 60 m, respectively, are losing mass at an increasing rate. To acquire continuous information of the cryosphere, after the Ice, Cloud, and land Elevation Satellite (ICESat) (2003-2010), NASA is actively planning for the ICESat-2 mission. Both ICESat and ICESat-2 are space-borne lidar altimetry systems. The systems measure the time of flight of the arriving photons that are reflected by the surface to deduce the elevation of the underlying terrain. As one of NASA's top priority missions, ICESat-2 is scheduled to launch in 2016. One of the major science goals of ICESat-2 is to quantify the ice sheet mass balance to determine its contributions to the sea level change and its impacts on ocean circulation (Abdalati et al. 2010). Compared to ICESat, which operates at 40 Hz and records the reflected laser energy as a waveform, the significantly improved ICESat-2 lidar employs a 532 nm micro-pulse photon counting system that operates at a high frequency of 10kHz with single photon detectability (Yang et al. 2012). To achieve its science goals, ICESat-2 requires the ability of detecting the elevation change with an accuracy of 0.2 cm/year over the entire ice sheet. Since every photon emitted by the lidar system will travel through the atmosphere, clouds can certainly affect the flight time of the arriving photons. Forward scattering by cloud particles increases the photon path length, thus resulting in biases in ice sheet elevation measurements known as atmospheric path delay (Duta et al. 2001, Yang et al. 2010, 2011). To ensure the accuracy of ICESat-2 surface elevation measurements, it is critical to understand how clouds would affect the travel time of arriving photons. In this talk, we will first present a framework that simulates the behavior of a space-borne 532 mn micro-pulse photon counting lidar in cloudy and clear atmospheres. To investigate the process of laser propagation through clouds, a 3-D Monte Carlo radiative transfer model is used to simulate the photon path distribution and the Poisson distribution is adopted for the number of photon returns. Since the photon counting system only registers the time of the first arriving photon within the detector "dead time", the retrieved average surface elevation tends to bias towards higher values. This is known as the first photon bias. With the scenarios simulated here, the first photon bias for clear sky is about 6.5 cm. Clouds affect surface altimetry in two ways: (1) cloud attenuation lowers the average number of arriving photons and hence reduces the first photon bias; (2) cloud forward scattering increases the photon path length and makes the surface appear further away from the satellite. Compared to clear sky, the average surface elevation detected by the photon counting system for cloudy sky with optical depth 1.0 is 4.0 to 6.0 cm lower for the simulations conducted. The effect of surface roughness on the accuracy of elevation retrievals will also discussed.

Yang, Yuekui↗

Theory of CW lidar aerosol backscatter measurements and development of a 2.1 microns solid-state pulsed laser radar for aerosol backscatter profiling

The performance and calibration of a focused, continuous wave, coherent detection CO2 lidar operated for the measurement of atmospheric backscatter coefficient, B(m), was examined. This instrument functions by transmitting infrared (10 micron) light into the atmosphere and collecting the light which is scattered in the rearward direction. Two distinct modes of operation were considered. In volume mode, the scattered light energy from many aerosols is detected simultaneously, whereas in the single particle mode (SPM), the scattered light energy from a single aerosol is detected. The analysis considered possible sources of error for each of these two cases, and also considered the conditions where each technique would have superior performance. The analysis showed that, within reasonable assumptions, the value of B(m) could be accurately measured by either the VM or the SPM method. The understanding of the theory developed during the analysis was also applied to a pulsed CO2 lidar. Preliminary results of field testing of a solid state 2 micron lidar using a CW oscillator is included.

Kavaya, Michael J.↗

Laser Ablation Experiments on the Tamdakht H5 Chondrite

High-powered lasers were used to induce ablation and to form fusion crusts in the lab on Tamdakht H5 chondrites and basalt. These ground tests were undertaken to improve our understanding, and ultimately improve our abilty to model and predict, meteoroid ablation during atmospheric entry. The infrared fiber laser at the LHMEL facilty, operated in the continuous wave (i.e. non-pulsed) mode, provided radiation surface heat flux at levels similar to meteor entry for these tests. Results are presented from the first round of testing on samples of Tamdakht H5 ordinary chondrite which were ex-posed to entry-relevant heating rates between 2 and 10 kWcm2.

meteor↗

Multi-Wavelength Laser Transmitter for the Two-Step Laser Time-of-Flight Mass Spectrometer

Missions to diverse Outer Solar System bodies will require investigations that can detect a wide range of organics in complex mixtures, determine the structure of selected molecules, and provide powerful insights into their origin and evolution. Previous studies from remote spectroscopy of the Outer Solar System showed a diverse population of macromolecular species that are likely to include aromatic and conjugated hydrocarbons with varying degrees of methylation and nitrile incorporation. In situ exploration of Titan's upper atmosphere via mass and plasma spectrometry has revealed a complex mixture of organics. Similar material is expected on the Ice Giants, their moons, and other Outer Solar System bodies, where it may subsequently be deposited onto surface ices. It is evident that the detection of organics on other planetary surfaces provides insight into the chemical and geological evolution of a Solar System body of interest and can inform our understanding of its potential habitability. We have developed a prototype two-step laser desorption/ionization time-of-flight mass spectrometer (L2MS) instrument by exploiting the resonance-enhanced desorption of analyte. We have successfully demonstrated the ability of the L2MS to detect hydrocarbons in organically-doped analog minerals, including cryogenic Ocean World-relevant ices and mixtures. The L2MS instrument operates by generating a neutral plume of desorbed analyte with an IR desorption laser pulse, followed at a delay by a ultraviolet (UV) laser pulse, ionizing the plume. Desorption of the analyte, including trace organic species, may be enhanced by selecting the wavelength of the IR desorption laser to coincide with IR absorption features associated with vibration transitions of minerals or organic functional groups. In this effort, a preliminary laser developed for the instrument uses a breadboard mid-infrared (MIR) desorption laser operating at a discrete 3.475 μm wavelength, and a breadboard UV ionization laser operating at a wavelength of 266 nm. The MIR wavelength was selected to overlap the C-H stretch vibrational transition of certain aromatic hydrocarbons, and the UV wavelength provides additional selectivity to aromatic species via UV resonance-enhanced multiphoton ionization effects. The use of distinct laser wavelengths allows efficient coupling to the vibrational and electronic spectra of the analyte in independent desorption and ionization steps, mitigating excess energy that can lead to fragmentation during the ionization process and leading to selectivity that can aid in data interpretation.

Yu, Anthony W.↗