Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Advancing the Fork detector for quantitative spent nuclear fuel verification

The Fork detector is widely used by the safeguards inspectorate of the European Atomic Energy Community (EURATOM) and the International Atomic Energy Agency (IAEA) to verify spent nuclear fuel. Fork measurements are routinely performed for safeguards prior to dry storage cask loading. Additionally, spent fuel verification will be required at the facilities where encapsulation is performed for acceptance in the final repositories planned in Sweden and Finland. The use of the Fork detector as a quantitative instrument has not been prevalent due to the complexity of correlating the measured neutron and gamma ray signals with fuel inventories and operator declarations. A spent fuel data analysis module based on the ORIGEN burnup code was recently implemented to provide automated real-time analysis of Fork detector data. This module allows quantitative predictions of expected neutron count rates and gamma units as measured by the Fork detectors using safeguards declarations and available reactor operating data. This study describes field testing of the Fork data analysis module using data acquired from 339 assemblies measured during routine dry cask loading inspection campaigns in Europe. Assemblies include both uranium oxide and mixed-oxide fuel assemblies. More recent measurements of 50 spent fuel assemblies at the Swedish Central Interim Storage Facility for Spent Nuclear Fuel are also analyzed. An evaluation of uncertainties in the Fork measurement data is performed to quantify the ability of the data analysis module to verify operator declarations and to develop quantitative go/no-go criteria for safeguards verification measurements during cask loading or encapsulation operations. The goal of this approach is to provide safeguards inspectors with reliable real-time data analysis tools to rapidly identify discrepancies in operator declarations and to detect potential partial defects in spent fuel assemblies with improved reliability and minimal false positive alarms. Finally, the results are summarized, and sources and magnitudes of uncertainties are identified, and the impact of analysis uncertainties on the ability to confirm operator declarations is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved accuracy in quantitative laser-induced breakdown spectroscopy using sub-models

We report that accurate quantitative analysis of diverse geologic materials is one of the primary challenges faced by the Laser-Induced Breakdown Spectroscopy (LIBS)-based ChemCam instrument on the Mars Science Laboratory (MSL) rover. The SuperCam instrument on the Mars 2020 rover, as well as other LIBS instruments developed for geochemical analysis on Earth or other planets, will face the same challenge. Consequently, part of the ChemCam science team has focused on the development of improved multivariate analysis calibrations methods. Developing a single regression model capable of accurately determining the composition of very different target materials is difficult because the response of an element’s emission lines in LIBS spectra can vary with the concentration of other elements. We demonstrate a conceptually simple “submodel” method for improving the accuracy of quantitative LIBS analysis of diverse target materials. The method is based on training several regression models on sets of targets with limited composition ranges and then “blending” these “sub-models” into a single final result. Tests of the sub-model method show improvement in test set root mean squared error of prediction (RMSEP) for almost all cases. Lastly, the sub-model method, using partial least squares regression (PLS), is being used as part of the current ChemCam quantitative calibration, but the sub-model method is applicable to any multivariate regression method and may yield similar improvements.

47 OTHER INSTRUMENTATION↗

Databases applicable to quantitative hazard/risk assessment-Towards a predictive systems toxicology

The Workshop on The Power of Aggregated Toxicity Data addressed the requirement for distributed databases to support quantitative hazard and risk assessment. The authors have conceived and constructed with federal support several databases that have been used in hazard identification and risk assessment. The first of these databases, the EPA Gene-Tox Database was developed for the EPA Office of Toxic Substances by the Oak Ridge National Laboratory, and is currently hosted by the National Library of Medicine. This public resource is based on the collaborative evaluation, by government, academia, and industry, of short-term tests for the detection of mutagens and presumptive carcinogens. The two-phased evaluation process resulted in more than 50 peer-reviewed publications on test system performance and a qualitative database on thousands of chemicals. Subsequently, the graphic and quantitative EPA/IARC Genetic Activity Profile (GAP) Database was developed in collaboration with the International Agency for Research on Cancer (IARC). A chemical database driven by consideration of the lowest effective dose, GAP has served IARC for many years in support of hazard classification of potential human carcinogens. The Toxicological Activity Profile (TAP) prototype database was patterned after GAP and utilized acute, subchronic, and chronic data from the Office of Air Quality Planning and Standards. TAP demonstrated the flexibility of the GAP format for air toxics, water pollutants and other environmental agents. The GAP format was also applied to developmental toxicants and was modified to represent quantitative results from the rodent carcinogen bioassay. More recently, the authors have constructed: 1) the NIEHS Genetic Alterations in Cancer (GAC) Database which quantifies specific mutations found in cancers induced by environmental agents, and 2) the NIEHS Chemical Effects in Biological Systems (CEBS) Knowledgebase that integrates genomic and other biological data including dose-response studies in toxicology and pathology. Each of the public databases has been discussed in prior publications. They will be briefly described in the present report from the perspective of aggregating datasets to augment the data and information contained within them.

60 APPLIED LIFE SCIENCES↗

Automated Quantitative Analysis of Extended Irradiation Defects - Dislocations, Voids and Precipitates in Neutron Irradiated HT-9 Steel

Structural alloys that make up the core components of nuclear reactors are exposed to radiation that can substantially alter the microstructure and mechanical properties of the material. Irradiation can cause the formation of extended defects including dislocation line and loops, voids and various types of precipitates. To understand the irradiation effects, it is critical to characterize these defects individually and collectively to quantify how they evolve throughout irradiation stages. Transmission electron microscopy (TEM) is a standard tool for providing extensive size, number density and spatial distribution of extended irradiation defects, however, manual measurement of defect size and number density requires time-intensive effort to analyze enough defects that provide a statistically meaningful result and are prone to errors of subjectivity. In this work, we developed a set of MATLAB algorithms offering robust and automated identification and quantification of extended irradiation defects like dislocation lines, voids and precipitates commonly observed in neutron irradiated cladding alloys [1]. Using a neutron-irradiated HT-9 martensitic alloy irradiated at 412°C to 111.8 dpa, we demonstrate the capability of these algorithms for quantitative defect analysis. Figure 1 presents defect images of the HT-9 using an advanced diffraction contrast imaging scanning transmission electron microscopy (DCI STEM) that suppresses bend contours and provides better defect contrast compared to conventional TEM [2]. The first step of defect analysis is defect identification, a process that can be digitally achieved by contrast thresholding (for simple defect contrast) and by machine learning computer vision for defect semantic segmentation [3]. Here, labeled binary defect images (Figures 2a and 2c) were used. For dislocation density quantification, we employed an optimized circular-grid intersection method first introduced by Dr. John Steeds [4]. This method is shown in Figures 2a and 2b, where the number of intersections of dislocation lines with circular traces was measured. This produces an unbiased sampling of dislocation lines, regardless of their orientation. This process was optimized with automated digital intersection number and grid length registration. Interestingly, it was found that a relatively large number of circles in a set circular gird is was needed to produce an invariant result (Figure 2b), with a low systematic measurement error. This demonstrates the main advantage of computer-based defect analysis, in performing repetitive operations quickly with a reduced systematic error. For the quantitative analysis of voids and precipitates a challenge encountered with automated defect analysis is feature overlap, particularly when the density of voids/precipitates is high. To mitigate this problem, as shown in Figure 2d, we modified the popular circular Hough transformation and treated ‘circular shape’ as the particle descriptor for voids/precipitates, efficiently resolving the overlapping particles. In summary, this automated digital quantification together with machine learning enabled defect identification [3] opens new opportunities for standardizing the characterization workflow for quantitative analysis of extended irradiation defects.

Sainju, Rajat↗

Combined Pulsed-Q dissociation and electron transfer dissociation for identification and quantitation of iTRAQ–labeled phosphopeptides

Multiplex isobaric tags for relative and absolute quantification (iTRAQ) enable high-throughput quantification of peptides via reporter ion signals in the low mass range of tandem mass spectra. A challenging but highly promising application is to analyze iTRAQ-labeled peptides using a sensitive linear ion trap mass spectrometer (LTQ-MS) and pulsed Q dissociation (PQD), a form of ion trap collision activated dissociation (CAD) designed to allow detection of low mass-to-charge fragment ions. Electron dissociation transfer (ETD), on the other hand, is complementary to PQD and is especially useful for sequencing peptides containing post-translational modifications (PTMs). Here, we developed an integrated workflow for robust and accurate quantitative identification of iTRAQ labeled phosphopeptides that integrates the PQD and ETD fragmentation methods together with PQD optimization, data management and bioinformatics tools. Analysis of the phosphoproteome of human fibroblast cells demonstrated that this hybrid mode is superior to either PQD or ETD alone for phosphopeptide identification and quantitation. The combined PQD/ETD approach can qualitatively identify additional phosphopeptides than ETD alone and PQD information can provide better quantitation of ETD identified iTRAQ-labeled phosphopeptides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative Separation of Unknown Organic–Metal Complexes by Liquid Chromatography–Inductively Coupled Plasma-Mass Spectrometry

Dissolved organic matter (DOM) is widely recognized to control the solubility and reactivity of trace metals in the environment. However, the mechanisms that govern metal-DOM complexation remain elusive, primarily due to the analytical challenge of fractionating and quantifying metal–organic species within the complex mixture of organic compounds that comprise DOM. Here, we describe a quantitative method for fractionation and element-specific detection of organic–metal complexes using liquid chromatography with online inductively coupled plasma mass spectrometry (LC–ICP-MS). The method implements a post-column compensation gradient to stabilize ICP–MS elemental response across the LC solvent gradient, thereby overcoming a major barrier to achieving quantitative accuracy with LC–ICP-MS. With external calibration and internal standard correction, the method yields concentrations of organic–metal complexes that were consistently within 6% of their true values, regardless of the complex’s elution time. We used the method to evaluate the effects of four stationary phases (C18, phenyl, amide, and pentafluoroylphenyl propyl) on the recovery and separation of environmentally relevant trace metals (Mn, Fe, Co, Ni, Cu, Zn, Cd, and Pb) in Suwannee River Fulvic Acid and Suwannee River Natural Organic Matter. The C18, amide, and phenyl phases generally yielded optimal metal recoveries (>75% for all metals except Pb), with the phenyl phase separating polar species to a greater extent than C18 or amide. We also fractionated organic-bound Fe, Cu, and Ni in oxidized and reduced soils, revealing divergent metal-DOM speciation across soil redox environments. Finally, by enabling quantitative fractionation of DOM-bound metals, our method offers a means for advancing a mechanistic understanding of metal–organic complexation throughout the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Online, Absolute Quantitation of Propranolol from Spatially Distinct 20- and 40-μm Dissections of Brain, Liver, and Kidney Thin Tissue Sections by Laser Microdissection–Liquid Vortex Capture–Mass Spectrometry

Here, spatial resolved quantitation of chemical species in thin tissue sections by mass spectrometric methods has been constrained by the need for matrix-matched standards or other arduous calibration protocols and procedures to mitigate matrix effects (e.g., spatially varying ionization suppression). Reported here is the use of laser cut and drop sampling with a laser microdissection-liquid vortex capture electrospray ionization tandem mass spectrometry (LMD-LVC/ESI-MS/MS) system for online and absolute quantitation of propranolol in mouse brain, kidney, and liver thin tissue sections of mice administered with the drug at a 7.5 mg/kg dose, intravenously. In this procedure either 20 μm x 20 μm or 40 μm x 40 μm tissue microdissections were cut and dropped into the flowing solvent of the capture probe. During transport to the ESI source drug related material was completely extracted from the tissue into the solvent, which contained a known concentration of propranolol-d 7 as an internal standard. This allowed absolute quantitation to be achieved with an external calibration curve generated from standards containing the same fixed concentration of propranolold-d 7 and varied concentrations of propranolol. Average propranolol concentrations determined with the laser cut and drop sampling method closely agreed with concentration values obtained from 2.3 mm diameter tissue punches from serial sections that were extracted and quantified by HPLC/ESI-MS/MS measurements. In addition, the relative abundance of hydroxypropranolol glucuronide metabolites were recorded and found to be consistent with previous findings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative Extraction and Mass Spectrometry Analysis at a Single-Cell Level

Quantitative live cell mass spectrometry analysis at a subcellular level requires the precisely controlled extraction of subpicoliter volumes of material from the cell, sensitive analysis of the extracted analytes, and their accurate quantification without prior separation. In this study, we demonstrate that localized electroosmotic extraction provides a direct path to addressing this challenge. Specifically, we demonstrate quantitative mass spectrometry analysis of biomolecules in picoliter volumes extracted from live cells. Electroosmotic extraction was performed using two electrodes and a finely pulled nanopipette with tip diameter of <1 µm containing a hydrophobic electrolyte compatible with mass spectrometry analysis. The electroosmotic drag was used to drive analytes out of the cell into the nanopipette. Analyte molecules extracted both from solutions and cell samples were analyzed using nanoelectrospray ionization (nanoESI) directly from the nanopipette into a mass spectrometer. More than 50 metabolites including sugars and flavonoids were detected in positive mode in 2-5 pL volumes of the cytoplasmic material extracted from Allium cepa. Quantification of the extracted glucose was performed using sequential extraction of a known volume of the aqueous solution containing glucose-d2 standard of known concentration. We found that the ratio of the signal of glucose to glucose-d2 increased linearly with glucose concentration. This observation indicates that the approach developed in this study enables quantitative analysis of small volumes of metabolites extracted from cells. Furthermore, we observed efficient separation of hydrophilic and hydrophobic analytes through partitioning into the aqueous and hydrophobic electrolyte phase, respectively, which provides additional important information on the molecular properties of extracted metabolites.

Yin, Ruichuan↗

Absolute Band Intensity of the Iodine Monochloride Fundamental Mode for Infrared Sensing and Quantitative Analysis

Iodine monochloride (ICl) is a gaseous off-product of molten salt reactors; monitoring this heteronuclear diatomic is of great interest for both environmental and safety purposes. In this paper we investigate the possibility of infrared monitoring of ICl by measuring the far-infrared absorption cross section of its fundamental band near 381 cm -1 . We have performed quantitative studies of the neat gas in a 20 cm cell at 25, 35, 50 and 70 oC at multiple pressures up to ~ 9 Torr and investigated the temperature and pressure dependence of the band’s infrared cross section. Quantitative measurements were problematic due to sample adhesion to the cell walls and windows as well as reactions/possible hydrolysis of ICl to form HCl gas. Effects were mitigated by measuring only the neat gas, using short measurement times and subtracting out the partial pressure of the HCl(g). The integrated band strength is shown to be temperature independent and was found to be equal to 9.1 x 10 -19 (cm 2 /molecule) cm-1. As expected, the temperature dependence of the band profile showed only a small effect over this limited temperature range. Furthermore, we have also investigated using the absorption data along with inverse least squares multivariate methods for the quantitative monitoring of ICl effluent concentrations under different scenarios using infrared (standoff) sensing and compare these results with traditional Beer’s Law (univariate) techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quality Assessments of Long-Term Quantitative Proteomic Analysis of Breast Cancer Xenograft Tissues

The identification of protein biomarkers requires large-scale analysis of human specimens to achieve statistical significance. In this study, we evaluated the long-term reproducibility of an iTRAQ (isobaric tags for relative and absolute quantification) based quantitative proteomics strategy using one channel for universal normalization across all samples. A total of 307 liquid chromatography tandem mass spectrometric (LC-MS/MS) analyses were completed, generating 107 one-dimensional (1D) LC-MS/MS datasets and 8 offline two-dimensional (2D) LC-MS/MS datasets (25 fractions for each set) for human-in-mouse breast cancer xenograft tissues representative of basal and luminal subtypes. Such large-scale studies require the implementation of robust metrics to assess the contributions of technical and biological variability in the qualitative and quantitative data. Accordingly, we developed a quantification confidence score based on the quality of each peptide-spectrum match (PSM) to remove quantification outliers from each analysis. After combining confidence score filtering and statistical analysis, reproducible protein identification and quantitative results were achieved from LC-MS/MS datasets collected over a 16 month period.

Environmental Molecular Sciences Laboratory↗

Quantitative Reflection Imaging for the Morphology and Dynamics of Live Aplysia californica Pedal Ganglion Neurons Cultured on Nanostructured Plasmonic Crystals

We describe a reflection imaging system that consists of a plasmonic crystal, a common laboratory microscope, and band-pass filters for use in the quantitative imaging and in situ monitoring of live cells and their substrate interactions. Surface plasmon resonance (SPR) provides a highly sensitive method to monitor changes in physicochemical properties occurring at metal-dielectric interfaces. Polyelectrolyte thin films deposited using the layer-by-layer (LBL) self-assembly method provide a reference system for calibrating the reflection contrast changes that occur when the polyelectrolyte film thickness changes and provide insight into the optical responses that originate from the multiple plasmonic features supported by this imaging system. Finitedifference time-domain (FDTD) simulations of the optical responses measured experimentally from the polyelectrolyte reference system are used to provide a calibration of the optical system for subsequent use in quantitative studies investigating live cell dynamics in cultures supported on a plasmonic crystal substrate. Live Aplysia californica pedal ganglion neurons cultured in artificial seawater were used as a model system through which to explore the utility of this plasmonic imaging technique. Here, the morphology of cellular peripheral structures ≲80 nm in thickness were quantitatively analyzed, and the dynamics of their trypsin-induced surface detachment were visualized. These results illustrate the capacities of this system for use in investigations of the dynamics of ultrathin cellular structures within complex bioanalytical environments.

47 OTHER INSTRUMENTATION↗

A Quantitative Molecular Atlas for Interactions Between Lignin and Cellulose

Lignin and cellulose are two of the most abundant polymers on Earth, and are found in close proximity within plant cell walls. Despite their ubiquity, relatively little is known quantitatively about their interactions within plants, and by extension how their interaction may affect industrial biomass utilization. Given the inherent heterogeneity of the lignin polymer and the structural complexity of cellulose, quantitative relationships between given cellulose faces and specific lignin chemistries have been challenging to ascertain experimentally. In this study, we use molecular simulation to examine individual combinations of cellulose binding face and lignin chemistry to build a quantitative lignin-cellulose interaction atlas, including contributions from both specific hydrogen bonds observed in simulation and nonspecific interactions between lignin and cellulose driven by solvent considerations. Over all monomeric and dimeric lignin chemistries tested, the hydrophobic 100 face is the preferred cellulose interaction site. Among the hydrophilic crystalline faces, binding of these molecules is strongest to the 110 cellulose face. The chemical composition of lignin monomers and dimers is also found to modulate the binding affinity, with additional methoxy groups increasing the contact area to the cellulose surface, which we hypothesize may protect native cellulose from degradation. Additional methoxylation and monomer linkages that facilitate planar aromatic ring orientations increase the binding affinity between small lignin-related molecules and cellulose, with the planar linkages between guaiacyl-type monomers leading to higher binding affinities. These trends can be extended to larger lignin polymers, where we quantify the relationships between lignin polymer size and binding affinity through replica exchange umbrella sampling simulations. Rather than molecular weight, the binding surface area between the lignin polymer and the cellulose surface dictates the interaction strength. As a result, based on the findings here, we expect there to be abundant and durable interaction between cellulose and lignin, particularly on the hydrophobic face of cellulose where cellulase enzymes typically bind.

09 BIOMASS FUELS↗

Quantitatively Probing the Al Distribution in Zeolites

The degree of substitution of Si4+ by Al3+ in the oxygen-terminated tetrahedra (Al T-sites) of zeolites determines the concentration of ion-exchange and Brønsted acid sites. As the location of the tetrahedra and the associated subtle variations in bond angles influence the acid strength, quantitative information about Al T-sites in the framework is critical to rationalize catalytic properties and to design new catalysts. A quantitative analysis is reported that uses a combination of extended X-ray absorption fine structure (EXAFS) analysis and 27Al MAS NMR spectroscopy supported by DFT-based molecular dynamics simulations. To discriminate individual Al atoms, sets of ab initio EXAFS spectra for various T-sites are generated from DFT-based molecular dynamics simulations allowing quantitative treatment of the EXAFS single- and multiple-photoelectron scattering processes out to 3-4 atom shells surrounding the Al absorption center. It is observed that identical zeolite types show dramatically different Al-distributions. A preference of Al for T-sites that are part of one or more 4-member rings in the framework over those T-sites that are part of only 5- and 6-member rings in the HBEA150 sample has been determined from a combination of these methods. This work was supported by the U. S. Department of Energy (DOE), Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences & Biosciences.

aluminum↗

Quantitative proteomic analyses of the response of acidophilic microbial communities to different pH conditions

Extensive genomic characterization of multi-species acid mine drainage microbial consortia combined with laboratory cultivation has enabled the application of quantitative proteomic analyses at the community level. In this study, quantitative proteomic comparisons were used to functionally characterize laboratory-cultivated acidophilic communities sustained in pH 1.45 or 0.85 conditions. The distributions of all proteins identified for individual organisms indicated biases for either high or low pH, and suggests pH-specific niche partitioning for low abundance bacteria and archaea. Although the proteome of the dominant bacterium, Leptospirillum group II, was largely unaffected by pH treatments, analysis of functional categories indicated proteins involved in amino acid and nucleotide metabolism, as well as cell membrane/envelope biogenesis were overrepresented at high pH. Comparison of specific protein abundances indicates higher pH conditions favor Leptospirillum group III, whereas low pH conditions promote the growth of certain archaea. Thus, quantitative proteomic comparisons revealed distinct differences in community composition and metabolic function of individual organisms during different pH treatments. Proteomic analysis revealed other aspects of community function. Different numbers of phage proteins were identified across biological replicates, indicating stochastic spatial heterogeneity of phage outbreaks. Additionally, proteomic data were used to identify a previously unknown genotypic variant of Leptospirillum group II, an indication of selection for a specific Leptospirillum group II population in laboratory communities. Our results confirm the importance of pH and related geochemical factors in fine-tuning acidophilic microbial community structure and function at the species and strain level, and demonstrate the broad utility of proteomics in laboratory community studies.

54 ENVIRONMENTAL SCIENCES↗

Quantitative decoding of coupled carbon and energy metabolism in Pseudomonas putida for lignin carbon utilization

Soil Pseudomonas species, which thrive on lignin derivatives, are widely explored for biotechnology applications in lignin valorization. However, how the native metabolism coordinates phenolic carbon processing with required cofactor generation remains poorly understood. Here, we achieve quantitative understanding of this metabolic balance through a detailed multi-omics investigation of Pseudomonas putida KT2440 grown on four common phenolic acid substrates: ferulate, p-coumarate, vanillate, and 4-hydroxybenzoate. Relative to succinate, proteomics reveals > 140-fold increase in transport and catabolic proteins for aromatics, but metabolomics identifies bottlenecks in initial catabolism to maintain favorable cellular energy charge, which is compromised in mutants with resolved bottlenecks. Up to 30-fold increase in pyruvate carboxylase and glyoxylate shunt proteins implies a metabolic remodeling confirmed by kinetic 13 C-metabolomics. Quantitative analysis by 13 C-fluxomics demonstrates coupling of this remodeling with cofactor production. Specifically, anaplerotic carbon recycling through pyruvate carboxylase promotes tricarboxylic acid cycle fluxes to generate 50-60% NADPH yield and 60-80% NADH yield, resulting in up to 6-fold greater ATP surplus than with succinate metabolism; the glyoxylate shunt sustains cataplerotic flux through malic enzyme for the remaining NADPH yield. This quantitative blueprint affords cofactor imbalance predictions in proposed engineering of key metabolic nodes in lignin valorization pathways.

09 BIOMASS FUELS↗

Quantitative modeling of ICRF antennas with integrated time domain RF sheath and plasma physics

Significant efforts have been made to quantitatively benchmark the sheath sub-grid model used in our time-domain simulations of plasma-immersed antenna near fields, which includes highly detailed three-dimensional geometry, the presence of the slow wave, and the non-linear evolution of the sheath potential. We present both our quantitative benchmarking strategy, and results for the ITER antenna configuration, including detailed maps of electric field, and sheath potential along the entire antenna structure. Our method is based upon a time-domain linear plasma model, using the finite-difference electromagnetic Vorpal/Vsim software. This model has been augmented with a non-linear rf-sheath sub-grid model, which provides a self-consistent boundary condition for plasma current where it exists in proximity to metallic surfaces. Very early, this algorithm was designed and demonstrated to work on very complicated three-dimensional geometry, derived from CAD or other complex description of actual hardware, including ITER antennas. Initial work with the simulation model has also provided a confirmation of the existence of propagating slow waves in the low density edge region, which can significantly impact the strength of the rf-sheath potential, which is thought to contribute to impurity generation. Our sheath algorithm is based upon per-point lumped-circuit parameters for which we have estimates and general understanding, but which allow for some tuning and fitting. We are now engaged in a careful benchmarking of the algorithm against known analytic models and existing computational techniques to insure that the predictions of rf-sheath voltage are quantitatively consistent and believable, especially where slow waves share in the field with the fast wave. Currently in progress, an addition to the plasma force response accounting for the sheath potential, should enable the modeling of sheath plasma waves, a predicted additional root to the dispersion, existing at the plasma-metal interface. Our model is presently restricted to plasma in the vicinity of metallic (highly conducting) surfaces, however we report on a new effort to include thin and thick dielectric (poorly conducting) surfaces, which are of interest to both fusion devices and to industrial plasmas, where dielectric, or dielectric-coated vessels and geometry are heavily used.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advances in quantitative nanoscale subsurface imaging by mode-synthesizing atomic force microscopy

This paper reports on advances toward quantitative non-destructive nanoscale subsurface investigation of a nanofabricated sample based on mode synthesizing atomic force microscopy with heterodyne detection, addressing the need to correlate the role of actuation frequencies of the probe f{sub p} and the sample f{sub s} with depth resolution for 3D tomography reconstruction. Here, by developing a simple model and validating the approach experimentally through the study of the nanofabricated calibration depth samples consisting of buried metallic patterns, we demonstrate avenues for quantitative nanoscale subsurface imaging. Our findings enable the reconstruction of the sample depth profile and allow high fidelity resolution of the buried nanostructures. Non-destructive quantitative nanoscale subsurface imaging offers great promise in the study of the structures and properties of complex systems at the nanoscale.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nanotag-enabled photonic crystal fiber as quantitative surface-enhanced Raman scattering optofluidic platform

Core-shell nanotags that are active in surface-enhanced Raman scattering (SERS) and entrapped with thiocyanate (SCN) label molecules were immobilized in the air channels of suspended-core photonic crystal fiber (PCF) to impart quantitative capacity to SERS-based PCF optofluidic sensing platform. The Raman intensity of Rhodamine 6G increases with concentration, whereas the intensity of SCN remains constant when measured using this platform. The signal from the SCN label can be used as an internal reference to establish calibration for quantitative measurements of analytes of unknown concentrations. The long optical path-length PCF optofluidic platform integrated with SERS-active core-shell nanotags holds significant promise for sensitive quantitative chem/bio measurements with the added benefit of small sampling volume. The dependence of SERS intensity on the nanotag coverage density and PCF length was interpreted based on numerical-analytical simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗