Scattering of lower hybrid radio frequency waves by cylindrical turbulent structures in the plasma edge in tokamaks

Lower hybrid (LH) radio frequency (RF) waves are used in fusion tokamak devices to generate non-inductively toroidal currents. LH waves are effective in imparting toroidal momentum to electrons in the core of the confined plasma. Since the LH waves are generated by wave guide structures near the wall of a tokamak, the waves have to propagate through a turbulent plasma in the edge region before coupling to the core. It is especially important to quantify the effect of this plasma region on the propagation characteristics of the LH waves, since fusion reactors like ITER will have an extended edge region. Structures in the plasma edge like filaments and blobs which have highly varying density fluctuations compared to the background density, span radial spatial scales that are comparable to the LH wavelength. We study the scattering of the LH waves by the filamentary structures using Maxwell's equations, in which the plasma permittivity is given by the cold plasma dispersion tensor. The collisional absorption of LH waves in the edge region is included by a modification to the elements of the dispersion tensor. The filaments are assumed to be cylindrical with the axis predominantly aligned along the direction of the toroidal magnetic field. Our studies are both analytical and numerical [1,2] and show that these structures can lead to reflection, refraction, diffraction, and side-scattering of both an incident LH plane wave and a Gaussian beam. We will present a variety of different density variations and collisional absorption rates in plasmas with filamentary structures of varying sizes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scattering of radio frequency waves by randomly modulated density interfaces in the edge of fusion plasmas

In the scrape-off layer and the edge region of a tokamak, the plasma is strongly turbulent and scatters the radio frequency (RF) electromagnetic waves that propagate through this region. It is important to know, whether used for diagnostics or for heating and current drive, the spectral properties of these scattered RF waves. The spectral changes influences the interpretation of the diagnostic-data obtained and the current and heating profiles. A full-wave, 3D electromagnetic code ScaRF (see Papadopoulos et al. 2019) has been developed for studying the RF wave propagation through turbulent plasma. ScaRF is a finite-difference frequency-domain (FDFD) method for solving Maxwell's equations. The magnetized plasma is defined through the cold plasma, anisotropic permittivity tensor. As a result, ScaRF can be used to study the scattering of any cold plasma RF wave. It can be for the study of scattering of electron cyclotron waves in ITER-type and medium-sized tokamaks such as TCV, ASDEX-U, DIII-D. For the case of medium-sized tokamaks, there's experimental evidence that drift waves and rippling modes are present in the edge region (see Ritz et al. 1984). Hence, we study the scattering of RF waves by periodic density interfaces (plasma gratings) in the form of a superposition of spatial modes with varying periodicity and random amplitudes (see Papadopoulos et al. 2019). The power reflection coefficient (a random variable) is calculated for different realizations of the density interface. In this work, the uncertainty of the power reflection coefficient is rigorously quantified by use of the Polynomial Chaos Expansion (see Xiu & Karniadakis 2002) method in conjunction with the Smolyak sparse grid integration (see Papadopoulos et al. 2018) (PCE-SG). The PCE-SG method is proven accurate and much more efficient (roughly 2-orders of magnitude shorter execution time) compared to alternative methods such as the Monte Carlo (MC) approach.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Passive magnetic devices

A passive magnetic device (PMD) has a base electrode, a multi-port signal structure (MPSS), and a substrate therebetween. The MPSS has a central plate residing in a second plane and at least two port tabs spaced apart from one another and extending from the central plate. The substrate has a central portion that defines a mesh structure between the base electrode and the central plate of the multi-port signal structure. A plurality of magnetic pillars are provided within the mesh structure, wherein each of the plurality of the magnetic pillars are spaced apart from one another and surrounded by a corresponding portion of the mesh structure. The PMD may provide a magnetically self-biased device that may be used as a radio frequency (RF) circulator, an RF isolator, and the like.

42 ENGINEERING↗

Bi-triaxial photoconductive switch module

Methods, systems, and devices describe bi-triaxial photoconductive switch modules that that eliminate the need for external DC blocking capacitors, while providing a highly compact structure that can produce bipolar output waveforms conducive to feeding to radio-frequency (RF) devices, such as antennas. Some implementations of the disclosed bi-triaxial photoconductive switch modules utilize unified cast-in-place capacitors that can be designed with an appropriate geometry, volume and orientation to provide desired energy storage capacity while eliminating or reducing parasitics.

42 ENGINEERING↗

Passive magnetic devices

A passive magnetic device (PMD) has a base electrode, a multi-port signal structure (MPSS), and a substrate therebetween. The MPSS has a central plate residing in a second plane and at least two port tabs spaced apart from one another and extending from the central plate. The substrate has a central portion that defines a mesh structure between the base electrode and the central plate of the multi-port signal structure. A plurality of magnetic pillars are provided within the mesh structure, wherein each of the plurality of the magnetic pillars are spaced apart from one another and surrounded by a corresponding portion of the mesh structure. The PMD may provide a magnetically self-biased device that may be used as a radio frequency (RF) circulator, an RF isolator, and the like.

Ketterson, Andrew Arthur↗

Construction of structures by joining of pre-formed tape

Various components, such as radio frequency (RF) or thermal reflectors, may be constructed from joining of pre-formed tape. For reflectors, this process may reduce the number of ribs, only require partial ribs, or eliminate the use of ribs altogether. To build such a reflector, a spool of tape, a joining tractor, and a foundation ring may be employed.

Bronisz, Lawrence Eugene↗

Electronic demodulation of optically phase demodulated signals

Device, methods and systems for the electronic demodulation of optically phase demodulated signals are described. An example optical local oscillator generator configured to generate a radio frequency (RF) tone at a desired RF frequency includes a first input configured to receive a broadband optical pulse train, a second input coupled to a delay line interferometer to receive a first control voltage for controlling a delay value of the interferometer and to produce an output optical pulse train, a dispersive element, coupled to the delay line interferometer, to map the output optical pulse train to a time-domain modulated optical pulse train, an optical-to-electrical converter, coupled to the dispersive element, to convert the time-domain modulated optical pulse train to an analog electrical signal, and an RF filter, coupled to the optical-to-electrical converter, to filter the analog electrical signal to generate the RF tone at the desired RF frequency.

Perlmutter, David Simon↗

Microfabricated ion trap chip with in situ radio-frequency sensing

A radio-frequency (RF) surface ion trap chip includes an RF electrode and an integrated capacitive voltage divider in which an intermediate voltage node is capacitively connected between the RF electrode and a ground. A sensor output trace is connected to the intermediate voltage node.

Maunz, Peter Lukas Wilhelm↗

Methods for attaching transmitters to animals

Methods for attaching a radio frequency (RF) transmitter to an animal are provided. The methods can include providing an RF transmitter and providing an injection device having a needle of gauge of 9 or smaller; providing the RF transmitter into the injection device; and providing the RF transmitter through the 9 gauge or smaller needle and into the animal.

Deng, Z. Daniel↗

High power handling digitizer using photonics

Devices, methods for analog-to-digital converters (ADCs) that perform high-dynamic range measurements based on optical techniques are disclosed. In one example aspect, an optical encoder includes a polarization rotator configured to receive a train of optical pulses, and an electro-optic (EO) modulator coupled to an output of the polarization rotator. The EO modulator is configured to receive a radio frequency (RF) signal and to produce a phase modulated signal in accordance with the RF signal. The optical encoder also includes a polarizing beam splitter coupled to the output of the EO modulator; and an optical hybrid configured to receive two optical signals from the polarizing beam splitter and to produce four optical outputs that are each phase shifted with respect to one another.

DeVore, Peter Thomas Setsuda↗

Radio frequency passband signal generation using photonics

Devices, methods and systems for generating wideband, high-fidelity arbitrary radio frequency (RF) passband signals are described. A voltage tunable optical filter for arbitrary RF passband signal generation includes a first input configured to receive a broadband optical pulse train, a second input configured to receive a first control voltage representative of an amplitude signal, an electrooptic modulator to receive the broadband optical pulse train and the first control voltage, to modulate the broadband optical pulse train in accordance with the amplitude signal, and to produce two complementary optical outputs that form two arms of an interferometer, an optical delay component to impart an optical path difference into one of the complementary outputs of the electrooptic modulator, and a combiner or a splitter to receive two complementary optical outputs of the electrooptic modulator after impartation of the optical path difference and to produce an output interference pattern of fringes.

Gowda, Apurva Shantharaj↗

SRF Levitation and Trapping of Nanoparticles

A proposal has been conceived to levitate and trap mesoscopic particles using radio frequency (RF) fields in a superconducting RF(SRF) cavity. Exploiting the intrinsic characteristics of an SRF cavity, this proposal aims at overcoming a major limit faced by state-of-the-art laser trapping techniques. The goal of the proposal is to establish a foundation to enable observation of quantum phenomena of an isolated mechanical oscillator interacting with microwave fields. An experiment supported by LDRD funding at JLab has started to address R&D issues relevant to these new research directions using existing SRF facilities at JLab. The success of this experiment would establish its groundbreaking relevance to quantum information science and technology, which may lead to applications in precision force measurement sensors, quantum memories, and alternative quantum computing implementations with promises for superior coherence characteristics and scalability well beyond the start-of-the-art. In this contribution, we will introduce the proposal and basic consideration of the experiment.

Geng, Rong-Li↗

Methods for attaching transmitters to animals

Methods for attaching a radio frequency (RF) transmitter to an animal are provided. The methods can include providing an RF transmitter and providing an injection device having a needle of gauge of 9 or smaller; providing the RF transmitter into the injection device; and providing the RF transmitter through the 9 gauge or smaller needle and into the animal.

59 BASIC BIOLOGICAL SCIENCES↗

Wireless power transfer to biomedical implants

Various examples are provided for wireless power transfer to implants. In one example, a system includes a radio frequency (RF) power source and a transmitter (TX) array comprising an excitation coil and resonant coils distributed about the excitation coil. The TX array can transfer power from the RF power source to a biomedical implant inserted below a skin surface of a subject when the TX array is positioned on the skin surface adjacent to the biomedical implant. A receiver (RX) coil of the biomedical implant can inductively couple with the TX array for the power. The resonant coils can allow power transfer when the RX coil is not aligned with the excitation coil.

Lin, Jenshan↗

Gas-filled radio-frequency beam detector

A system for monitoring intensity of a particle beam can include one or more radio-frequency (RF) detectors coupled to a signal analyzer that can be placed outside the radiation field of the particle beam. Each RF detector can include a gas-filled RF cavity coupled to one or more gas-filled waveguides. The signal analyzer can self-calibrate before the particle beam is turned on for determining one or more absolute intensities of the particle beam when the particle beam is present.

Yonehara, Katsuya↗

Radio frequency passband signal generation using photonics

Devices, methods and systems for generating wideband, high-fidelity arbitrary radio frequency (RF) passband signals are described. A voltage tunable optical filter for arbitrary RF passband signal generation includes a first input configured to receive a broadband optical pulse train, a second input configured to receive a first control voltage representative of an amplitude signal, an electrooptic modulator to receive the broadband optical pulse train and the first control voltage, to modulate the broadband optical pulse train in accordance with the amplitude signal, and to produce two complementary optical outputs that form two arms of an interferometer, an optical delay component to impart an optical path difference into one of the complementary outputs of the electrooptic modulator, and a combiner or a splitter to receive two complementary optical outputs of the electrooptic modulator after impartation of the optical path difference and to produce an output interference pattern of fringes.

Gowda, Apurva Shantharaj↗

Wireless power transfer to biomedical implants

Various examples are provided for wireless power transfer to implants. In one example, a system includes a radio frequency (RF) power source and a transmitter (TX) array comprising an excitation coil and resonant coils distributed about the excitation coil. The TX array can transfer power from the RF power source to a biomedical implant inserted below a skin surface of a subject when the TX array is positioned on the skin surface adjacent to the biomedical implant. A receiver (RX) coil of the biomedical implant can inductively couple with the TX array for the power transfer. The resonant coils can allow power transfer when the RX coil is not aligned with the excitation coil.

Lin, Jenshan↗

Study of Microphonic Effects on the C100 Cryomodule for High Energy Electron Beam Accelerators

The Continuous Electron Beam Accelerator Facility (CEBAF) at Thomas Jefferson National Laboratory (JLab) is a particle accelerator which can accelerate an electron beam to relativistic speeds and apply the beam onto target samples. The C100 superconducting radio frequency (SRF) cavity is the primary accelerating structure of the C100 cryomodule, one of the many cryomodules which compose the CEBAF linear accelerator. SRF cavities are particularly sensitive to internal and external vibrations that can result in a phenomenon called microphonics which degrade the operational stability of a cryomodule. The purpose of this thesis is to investigate the significance of mechanical disturbances on the electromagnetic resonant frequency of a C100 SRF cavity. Knowledge of the mechanical resonance of the cavities and cryomodule sheds light into how these disturbances are most easily realized as deformation which causes radio frequency (RF) detuning. Three studies were conducted: the development and hammer test calibration of a Finite Element Analysis (FEA) model of a C100 cavity, the development and hammer test calibration of an FEA model of a C100 cavity string, and the hammer test of the C100-10R cryomodule at the Cryomodule Test Facility (CMTF). The cavity FEA model was found to accurately predict two modes found in two real cavities in a simply supported configuration. The cavity string FEA model leveraged the calibrated cavity FEA model but was not found to accurately predict the modal behavior of a real cavity string. Even so, the modal behavior of the cavity string inside the C100-10R cryomodule was captured during a hammer test while it was partially assembled. Finally, the C100-10R cryomodule was placed in the CMTF to study RF detuning. The RF detuning spectra during hammer hits and background noise was captured. The results of the hammer testing indicate two strong peaks at low frequencies (9-10 Hz and 22-23 Hz). These two frequencies were found to be nearly coincident to four instances of mechanical resonance found during the hammer testing done on the partially-assembled C100-10R. Because of this, these two modes are believed to contribute to RF detuning of the cryomodule. This test event also included the testing of the effectiveness of a configuration of BNNT canisters designed to act as dampers. While these tests show promising results, the lurking variables render these tests somewhat inconclusive.