At least 253 records · Page 14

Development and assessment of a model predictive controller enabling anticipatory control strategies for a heat-pipe system

To support the reliable and resilient operation of modular reactors and microreactors, anticipatory control strategies have been proposed for achieving faster-than-real-time predictions and decision-making capabilities in anticipation of potential anomalies, including setpoint changes and cyber incidents. Here this work presents how anticipatory control strategies can be implemented via model predictive control (MPC) of a single heat pipe’s temperature. Considering the uncertainty in developing and applying MPC, this work evaluates MPC performance given three different model forms: a linear response surface model, an artificial neural network (ANN), and an autoregressive model with exogenous input (ARX). This work also evaluates the impacts of different input biases and variance on MPC performance in order to account for potential sensor reading variations due to cyber incidents. We observe that nonparametric models such as the ANN and ARX result in more fluctuated control actions compared to the MPC applied to the linear response surface model. However, when the cyber incidents are of a large magnitude, the linear response surface model produces smaller feasible regions than the nonparametric models under identical constraints.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

WE-E-18C-01: Multi-Energy CT: Current Status and Recent Innovations

Conventional computed tomography (CT) uses a single polychromatic x-ray spectrum and energy integrating detectors, and produces images whose contrast depends on the effective attenuation coefficient of the broad spectrum beam. This can introduce errors from beam hardening and does not produce the optimal contrast-to-noise ratio. In addition, multiple materials can have the same effective attenuation coefficient, causing different materials to be indistinguishable in conventional CT images. If transmission measurements at two or more energies are obtained, even with polychromatic beams, more specific information about the object can be obtained. If the object does not contain materials with k-edges in the spectrum, the x-ray attenuation can be well-approximated by a linear combination of two processes (photoelectric absorption and Compton scattering) or, equivalently, two basis materials. For such cases, two spectral measurements suffice, although additional measurements can provide higher precision. If K-edge materials are present, additional spectral measurements can allow these materials to be isolated. Current commercial implementations use varied approaches, including two sources operating a different kVp, one source whose kVp is rapidly switched in a single scan, and a dual layer detector that can provide spectral information in every reading. Processing of the spectral information can be performed in the raw data domain or in the image domain. The process of calculating the amount of the two basis functions implicitly corrects for beam hardening and therefore can lead to improvements in quantitative accuracy. Information can be extracted to provide material specific information beyond that of conventional CT. This additional information has been shown to be important in several clinical applications, and can also lead to more efficient clinical protocols. Recent innovations in x-ray sources, detectors, and systems have made multi-energy CT much more practical and improved its performance. In addition, this is a very active area of research and further improvements are expected through further technological improvements. Learning Objectives: Basic principles of multi-energy CT Current implementations of mutli-energy CT Data and image analysis methods in multi-energy CT Current clinical applications of dual energy CT5. recent innovations and anticipated advances in multi-energy CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Error-controlled, progressive, and adaptable retrieval of scientific data with multilevel decomposition

Extreme-scale simulations and high-resolution instruments have been generating an increasing amount of data, which poses significant challenges to not only data storage during the run, but also post-processing where data will be repeatedly retrieved and analyzed for a long period of time. The challenges in satisfying a wide range of post-hoc analysis needs while minimizing the I/O overhead caused by inappropriate and/or excessive data retrieval should never be left unmanaged. In this paper, we propose a data refactoring, compressing, and retrieval framework capable of 1) fine-grained data refactoring with regard to precision; 2) incrementally retrieving and recomposing the data in terms of various error bounds; and 3) adaptively retrieving data in multi-precision and multi-resolution with respect to different analysis. With the progressive data re-composition and the adaptable retrieval algorithms, our framework significantly reduces the amount of data retrieved when multiple incremental precision are requested and/or the downstream analysis time when coarse resolution is used. Experiments show that the amount of data retrieved under the same progressively requested error bound using our framework is 64% less than that using state-of-the-art single-error-bounded approaches. Parallel experiments with up to 1, 024 cores and ~ 600 GB data in total show that our approach yields 1.36× and 2.52× performance over existing approaches in writing to and reading from persistent storage systems, respectively.

Liang, Xin↗

Rapid Threat Organism Recognition Pipeline

The RAPTOR computational pipeline identifies microbial nucleic acid sequences present in sequence data from clinical samples. It takes as input raw short-read genomic sequence data (in particular, the type generated by the Illumina sequencing platforms) and outputs taxonomic evaluation of detected microbes in various human-readable formats. This software was designed to assist in the diagnosis or characterization of infectious disease, by detecting pathogen sequences in nucleic acid sequence data from clinical samples. It has also been applied in the detection of algal pathogens, when algal biofuel ponds became unproductive. RAPTOR first trims and filters genomic sequence reads based on quality and related considerations, then performs a quick alignment to the human (or other host) genome to filter out host sequences, then performs a deeper search against microbial genomes. Alignment to a protein sequence database is optional. Alignment results are summarized and placed in a taxonomic framework using the Lowest Common Ancestor algorithm.

Solberg, OwenD.↗

Carbon dioxide, water vapor and methane soil efflux (soil respiration) in a Pinus palustris restoration site in Georgetown, SC

This dataset contains processed data from a combination of survey flux chambers and long-term automated flux chambers. Biweekly soil flux measurements were conducted from June 2023 through December 2025 at a longleaf pine restoration site in Georgetown, SC. Processed, QAQC’d data can be found in the file: 1_DATA_ESS_DOE_HR_RS_HB3_QAQC_Survey_Data_20260223.csv. Raw and working data files (.json, & .81x format) from LI-COR equipment are included for reference and can be accessed using SoilFluxPro software. CSV metadata files describe the raw data and modifications made using SoilFluxPro v5 and Matlab R2024b, as well as formatting and units for processed CSVs. Matlab code is included for reading in the processed CSVs. This research was performed as part of the project: “Improving models of stand and watershed carbon and water fluxes with more accurate representations of soil-plant-water dynamics in southern pine ecosystems”, which examines in part the effects hydraulic redistribution on soil efflux of carbon dioxide, water vapor and methane, as well as soil moisture and temperature in a southern pine ecosystem with sandy soils and high water table.

CARBON DIOXIDE FLUX↗

Energy Evaluation of a New Construction Pilot Community: Fresno, California

A new construction pilot community was constructed by builder-partner Wathen-Castanos Hybrid Homes based on a single occupied test house that was designed to achieve greater than 30% energy savings with respect to the Building America House Simulation Protocols developed by NREL. Builders face several key problems when implementing a whole-house systems integrated measures package from a single test house into multiple houses. This report addresses factors of implementation and scalability at the community scale and proposes methodologies by which community-scale energy evaluations can be performed based on results at the occupied test house level. Research focused on the builder and trade implementation of a measures package and the actual utility usage in the houses at the community scale of production. Five occupants participated in this research by providing utility bills and information on occupancy and miscellaneous gas and electric appliance use for their houses. IBACOS used these utility data and background information to analyze the actual energy performance of the houses. The actual utility bill readings were compared to projected energy consumption using BEopt with actual weather and thermostat set points for normalization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Effects of Herbarium Specimen Characteristics on Short-Read NGS Sequencing Success in Nearly 8000 Specimens: Old, Degraded Samples Have Lower DNA Yields but Consistent Sequencing Success

Phylogenetic datasets are now commonly generated using short-read sequencing technologies unhampered by degraded DNA, such as that often extracted from herbarium specimens. The compatibility of these methods with herbarium specimens has precipitated an increase in broad sampling of herbarium specimens for inclusion in phylogenetic studies. Understanding which sample characteristics are predictive of sequencing success can guide researchers in the selection of tissues and specimens most likely to yield good results. Multiple recent studies have considered the relationship between sample characteristics and DNA yield and sequence capture success. Here we report an analysis of the relationship between sample characteristics and sequencing success for nearly 8,000 herbarium specimens. This study, the largest of its kind, is also the first to include a measure of specimen quality (“greenness”) as a predictor of DNA sequencing success. We found that taxonomic group and source herbarium are strong predictors of both DNA yield and sequencing success and that the most important specimen characteristics for predicting success differ for DNA yield and sequencing: greenness was the strongest predictor of DNA yield, and age was the strongest predictor of proportion-on-target reads recovered. Surprisingly, the relationship between age and proportion-on-target reads is the inverse of expectations; older specimens performed slightly better in our capture-based protocols. We also found that DNA yield itself is not a strong predictor of sequencing success. Most literature on DNA sequencing from herbarium specimens considers specimen selection for optimal DNA extraction success, which we find to be an inappropriate metric for predicting success using next-generation sequencing technologies.

54 ENVIRONMENTAL SCIENCES↗

In-mine testing of a natural background sensor, part B

The capability of a natural background sensor for measuring the thickness of top coal on a longwall face was examined. The limitations on the time during which tests could be performed, and the roof conditions, did not produce readings of top coal measurements during the shearer operation. It was demonstrated that the system is capable to survive operating conditions in the mine environment, while the static tests confirmed that the natural background sensor approach is a valid method of measuring top coal thickness in mines where the roof rock provides a constant radiation level. It is concluded that the practical results will improve sequent development of an integrated vertical control system which is information from the natural background system.

Martzloff, F. D.↗

Managing an archive of weather satellite images

The author's experiences of building and maintaining an archive of hourly weather satellite pictures at NOAO are described. This archive has proven very popular with visiting and staff astronomers - especially on windy days and cloudy nights. Given access to a source of such pictures, a suite of simple shell and IRAF CL scripts can provide a great deal of robust functionality with little effort. These pictures and associated data products such as surface analysis (radar) maps and National Weather Service forecasts are updated hourly at anonymous ftp sites on the Internet, although your local Atsmospheric Sciences Department may prove to be a more reliable source. The raw image formats are unfamiliar to most astronomers, but reading them into IRAF is straightforward. Techniques for performing this format conversion at the host computer level are described which may prove useful for other chores. Pointers are given to sources of data and of software, including a package of example tools. These tools include shell and Perl scripts for downloading pictures, maps, and forecasts, as well as IRAF scripts and host level programs for translating the images into IRAF and GIF formats and for slicing & dicing the resulting images. Hints for displaying the images and for making hardcopies are given.

Seaman, R. L.↗

The QWIP Focal Plane Assembly for NASA's Landsat Data Continuity Mission

The Thermal Infrared Sensor (TIRS) is a QWIP based instrument intended to supplement the Operational Land Imager (OLI) for the Landsat Data Continuity Mission (LDCM). The TIRS instrument is a dual channel far infrared imager with the two bands centered at 10.8 m and 12.0 m. The focal plane assembly (FPA) consists of three 640x512 GaAs Quantum Well Infrared Photodetector (QWIP) arrays precisely mounted to a silicon carrier substrate that is mounted on an invar baseplate. The two spectral bands are defined by bandpass filters mounted in close proximity to the detector surfaces. The focal plane operating temperature is 43K. The QWIP arrays are hybridized to Indigo ISC9803 readout integrated circuits (ROICs). Two varieties of QWIP detector arrays are being developed for this project, a corrugated surface structure QWIP and a grating surface structure QWIP. This paper will describe the TIRS system noise equivalent temperature difference sensitivity as it affects the QWIP focal plane performance requirements: spectral response, dark current, conversion efficiency, read noise, temperature stability, pixel uniformity, optical crosstalk and pixel yield. Additional mechanical constraints as well as qualification through Technology Readiness Level 6 (TRL 6) will also be discussed.

Jhabvala, M.↗

Analog bus driver and multiplexer

For a source-follower signal chain, the ohmic drop in the selection switch causes unacceptable voltage offset, non-linearity, and reduced small signal gain. For an op amp signal chain, the required bias current and the output noise rises rapidly with increasing the array format due to a rapid increase in the effective capacitance caused by the Miller effect boosting up the contribution of the bus capacitance. A new switched source-follower signal chain circuit overcomes limitations of existing op-amp based or source follower based circuits used in column multiplexers and data readout. This will improve performance of CMOS imagers, and focal plane read-out integrated circuits for detectors of infrared or ultraviolet light.

Pain, Bedabrata↗

High Operating Temperature Midwave Quantum Dot Barrier Infrared Detector (QD-BIRD)

The nBn or XBn barrier infrared detector has the advantage of reduced dark current resulting from suppressed Shockley-Read-Hall (SRH) recombination and surface leakage. High performance detectors and focal plane arrays (FPAs) based on InAsSb absorber lattice matched to GaSb substrate, with a matching AlAsSb unipolar electron barrier, have been demonstrated. The band gap of lattice-matched InAsSb yields a detector cutoff wavelength of approximately 4.2 ??m when operating at ~150K. We report results on extending the cutoff wavelength of midwave barrier infrared detectors by incorporating self-assembled InSb quantum dots into the active area of the detector. Using this approach, we were able to extend the detector cutoff wavelength to ~6 ?m, allowing the coverage of the full midwave infrared (MWIR) transmission window. The quantum dot barrier infrared detector (QD-BIRD) shows infrared response at temperatures up to 225 K.

quantum dot↗

The QWIP Focal Plane Assembly for NASA's Landsat Data Continuity Mission

The Thermal Infrared Sensor (TIRS) is a QWIP based instrument intended to supplement the Operational Land Imager (OLI) for the Landsat Data Continuity Mission (LDCM). The TIRS instrument is a dual channel far infrared imager with the two bands centered at 10.8[mu]m and 12.0[mu]m. The focal plane assembly (FPA) consists of three 640x512 GaAs Quantum Well Infrared Photodetector (QWIP) arrays precisely mounted to a silicon carrier substrate that is mounted on an invar baseplate. The two spectral bands are defined by bandpass filters mounted in close proximity to the detector surfaces. The focal plane operating temperature is 43K. The QWIP arrays are hybridized to Indigo ISC9803 readout integrated circuits (ROICs). Two varieties of QWIP detector arrays are being developed for this project, a corrugated surface structure QWIP and a grating surface structure QWIP. This paper will describe the TIRS system noise equivalent temperature difference sensitivity as it affects the QWIP focal plane performance requirements: spectral response, dark current, conversion efficiency, read noise, temperature stability, pixel uniformity, optical crosstalk and pixel yield. Additional mechanical constraints as well as qualification through Technology Readiness Level 6 (TRL 6) will also be discussed.

Jhabvala, M↗

In-situ Geochronology on the Mars 2020 Rover with KArLE (The Potassium-Argon Laser Experiment)

A successful Mars exploration program has revealed chapters of Mars history, but in this book, the pages are ripped out of the binding and scattered across the surface. An examination of each page reveals interesting information, but there is no way to read the book in a logical order. Geochronology is the tool that puts page number onto the individual pages, and allows the book of Martian history to be read in its proper order. The KArLE experiment performs the first dedicated in situ geochronology investigation on Mars, bringing clarity to Mars 2020 samples and context to its landing site.

Cohen, Barbara A.↗

Flood Mapping of Recent Major Hurricane Events with Synthetic Aperture Radar, Commercial Imaging, and Aerial Observations

Floodwater mapping is an important remote sensing process that is used for disaster response, recovery, and damage assessment practices. Developing a system to read in Synthetic Aperture Radar (SAR) data and perform land cover classification will allow for the production of near real-time inundation mapping, enabling government and emergency response entities to get a preliminary idea of the situation. SAR is a unique remote sensing tool. Data in this project was obtained by NASA Jet Propulsion Laboratory’s Uninhabited Aerial Vehicle SAR (UAVSAR), an L-band radar mounted to a Gulfstream III jet. Data collected by UAVSAR is similar to what will be available from the NASA-Indian Space Research Organization (NISAR) mission starting in early 2022. Using Python and ArcGIS applications, a model was developed using training samples taken from NOAA post-event aerial photography and UAVSAR data gathered in the aftermath of Hurricane Florence in September 2018.

Melancon, Alexander M.↗

Rapid Threat Organism Recognition Pipeline

The RAPTOR computational pipeline identifies microbial nucleic acid sequences present in sequence data from clinical samples. It takes as input raw short-read genomic sequence data (in particular, the type generated by the Illumina sequencing platforms) and outputs taxonomic evaluation of detected microbes in various human-readable formats. This software was designed to assist in the diagnosis or characterization of infectious disease, by detecting pathogen sequences in nucleic acid sequence data from clinical samples. It has also been applied in the detection of algal pathogens, when algal biofuel ponds became unproductive. RAPTOR first trims and filters genomic sequence reads based on quality and related considerations, then performs a quick alignment to the human (or other host) genome to filter out host sequences, then performs a deeper search against microbial genomes. Alignment to a protein sequence database is optional. Alignment results are summarized and placed in a taxonomic framework using the Lowest Common Ancestor algorithm.

Williams, Kelly P.↗

High-Speed Automated Tester for Vacuum Chamber Feedthrough Connectors and Cables

The Goddard Space Flight Center's thermal vacuum laboratory has developed a high-speed automated system for testing the integrity of 37-pin MIL-C-5015 cylindrical electrical feedthrough connectors used on penetration plates of thermal vacuum chambers. The system consists of a desktop PC driving a data acquisition front end. The latter measures the resistance through each pin of the connector and the resistance from each pin to all other pins and the connector shell. In addition to identifying unacceptable feedthroughs, the system is also used for testing cables. In the special case of Type T thermocouples (used almost exclusively at the lab), the difference in resistance between the copper and constantan wires provides positive proof of accidentally reversed connector wiring. Data acquisition time to completely test a cable or feedthrough connector is less than thirty seconds. The system provides a hardcopy printout of the resistance readings. Connectors or cables with fewer wires are tested using simple adapter cables. Initial tests indicate that the performance of a given feedthrough connector can be predicted on the basis of measured resistance readings, reducing ongoing cost of connector replacement. The opportunity to positively certify the integrity of cables, cable connectors and feedthroughs before the start of a thermal vacuum test minimizes the likelihood of a circuit problem that would require returning the chamber to ambient conditions for repair. This system has two principal advantages for the Goddard thermal vacuum laboratory. Its only significant cost was the labor to fabricate the test cable and shorting cable -- about 40 man-hours total. The system was built around a computer and data acquisition unit that were already on hand. The second advantage is that it very quickly tests both of the parameters that are essential.

Swope, Robert H.↗

Nonvolatile memory cells from hafnium zirconium oxide ferroelectric tunnel junctions using Nb and NbN electrodes

Ferroelectric tunnel junctions (FTJs) utilizing hafnium zirconium oxide (HZO) have attracted interest as non-volatile memory for microelectronics due to ease of integration into back-end-of-line (BEOL) complementary metal oxide semiconductor fabrication. This work examines asymmetric electrode NbN/HZO/Nb devices with 7 nm thick HZO as FTJs in a memory structure, with an output resistance that can be controlled by read and write voltages. The individual FTJs are measured to have a tunneling electroresistance of 10 during the read state without significant filament conduction formation and reasonable ferroelectric performance. Endurance and remanent polarizations of up to 10 5 cycles and 20 μC/cm 2 , respectively, are measured and are shown to be dependent on the cycling voltage. Electrical measurements demonstrate how magnitude of the write pulse can modulate the high state resistance and the read pulse influences both resistance values as well as separation of resistance states. Then, by using two opposite switching FTJ devices in series, a programmable nonvolatile resistor divider is demonstrated. Measurements of these two FTJ unit memory cells show wide applicability to a BEOL microfabrication process for a re-readable, rewritable, and nonvolatile memory cell.

42 ENGINEERING↗