Search NASA⌕ Search

SEARCH · Search NASA

Results for “readout electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Teachers guide for building and operating weather satellite ground stations for high school science

A number of colleges and universities are operating APT direct readout stations. However, high school science teachers have often failed to realize the potential of meteorological satellites and their products as unique instructional tools. The ability to receive daily pictures from these satellites offers exciting opportunities for secondary school teachers and students to assemble the electronic hardware and to view real time pictures of Earth from outer space. The station and pictures can be used in the classroom to develop an approach to science teaching that could span many scientific disciplines and offer many opportunities for student research and participation in scientific processes. This can be accomplished with relatively small expenditures of funds for equipment. In most schools some of the equipment may already be available. Others can be constructed by teachers and/or students. Yet another source might be the purchase of used equipment from industry or through the government surplus channels. The information necessary for individuals unfamiliar with these systems to construct a direct readout for receiving real time APT photographs on a daily basis in the classroom is presented.

Summers, R. J.↗

Active pixel sensor array with multiresolution readout

An imaging device formed as a monolithic complementary metal oxide semiconductor integrated circuit in an industry standard complementary metal oxide semiconductor process, the integrated circuit including a focal plane array of pixel cells, each one of the cells including a photogate overlying the substrate for accumulating photo-generated charge in an underlying portion of the substrate and a charge coupled device section formed on the substrate adjacent the photogate having a sensing node and at least one charge coupled device stage for transferring charge from the underlying portion of the substrate to the sensing node. There is also a readout circuit, part of which can be disposed at the bottom of each column of cells and be common to all the cells in the column. The imaging device can also include an electronic shutter formed on the substrate adjacent the photogate, and/or a storage section to allow for simultaneous integration. In addition, the imaging device can include a multiresolution imaging circuit to provide images of varying resolution. The multiresolution circuit could also be employed in an array where the photosensitive portion of each pixel cell is a photodiode. This latter embodiment could further be modified to facilitate low light imaging.

Fossum, Eric R.↗

Arrays of Carbon Nanotubes as RF Filters in Waveguides

Brushlike arrays of carbon nanotubes embedded in microstrip waveguides provide highly efficient (high-Q) mechanical resonators that will enable ultraminiature radio-frequency (RF) integrated circuits. In its basic form, this invention is an RF filter based on a carbon nanotube array embedded in a microstrip (or coplanar) waveguide, as shown in Figure 1. In addition, arrays of these nanotube-based RF filters can be used as an RF filter bank. Applications of this new nanotube array device include a variety of communications and signal-processing technologies. High-Q resonators are essential for stable, low-noise communications, and radar applications. Mechanical oscillators can exhibit orders of magnitude higher Qs than electronic resonant circuits, which are limited by resistive losses. This has motivated the development of a variety of mechanical resonators, including bulk acoustic wave (BAW) resonators, surface acoustic wave (SAW) resonators, and Si and SiC micromachined resonators (known as microelectromechanical systems or MEMS). There is also a strong push to extend the resonant frequencies of these oscillators into the GHz regime of state-of-the-art electronics. Unfortunately, the BAW and SAW devices tend to be large and are not easily integrated into electronic circuits. MEMS structures have been integrated into circuits, but efforts to extend MEMS resonant frequencies into the GHz regime have been difficult because of scaling problems with the capacitively-coupled drive and readout. In contrast, the proposed devices would be much smaller and hence could be more readily incorporated into advanced RF (more specifically, microwave) integrated circuits.

Hoppe, Daniel↗

Microelectronic DNA assay for the detection of BRCA1 gene mutations

Mutations in BRCA1 are characterized by predisposition to breast cancer, ovarian cancer and prostate cancer as well as colon cancer. Prognosis for this cancer survival depends upon the stage at which cancer is diagnosed. Reliable and rapid mutation detection is crucial for the early diagnosis and treatment. We developed an electronic assay for the detection of a representative single nucleotide polymorphism (SNP), deletion and insertion in BRCA1 gene by the microelectronics microarray instrumentation. The assay is rapid, and it takes 30 minutes for the immobilization of target DNA samples, hybridization, washing and readout. The assay is multiplexing since it is carried out at the same temperature and buffer conditions for each step. The assay is also highly specific, as the signal-to-noise ratio is much larger than recommended value (72.86 to 321.05 vs. 5) for homozygotes genotyping, and signal ratio close to the perfect value 1 for heterozygotes genotyping (1.04).

Validation Studies↗

Development and test of photon-counting microchannel plate detector arrays for use on space telescopes

The full sensitivity, dynamic range, and photometric stability of microchannel array plates(MCP) are incorporated into a photon-counting detection system for space operations. Components of the system include feedback-free MCP's for high gain and saturated output pulse-height distribution with a stable response; multi-anode readout arrays mounted in proximity focus with the output face of the MCP; and multi-layer ceramic headers to provide electrical interface between the anode array in a sealed detector tube and the associated electronics.

Timothy, J. G.↗

Wilbur: A low-cost CCD camera system for MDM Observatory

The recent availability of several 'off-the-shelf' components, particularly CCD control electronics from SDSU, has made it possible to put together a flexible CCD camera system at relatively low cost and effort. The authors describe Wilbur, a complete CCD camera system constructed for the Michigan-Dartmouth-MIT Observatory. The hardware consists of a Loral 2048(exp 2) CCD controlled by the SDSU electronics, an existing dewar design modified for use at MDM, a Sun Sparcstation 2 with a commercial high-speed parallel controller, and a simple custom interface between the controller and the SDSU electronics. The camera is controlled from the Sparcstation by software that provides low-level I/O in real time, collection of additional information from the telescope, and a simple command interface for use by an observer. Readout of the 2048(exp 2) array is complete in under two minutes at 5 e(sup -) read noise, and readout time can be decreased at the cost of increased noise. The system can be easily expanded to handle multiple CCD's/multiple readouts, and can control other dewars/CCD's using the same host software.

Metzger, M. R.↗

MOS Circuitry Would Detect Low-Energy Charged Particles

Metal oxide semiconductor (MOS) circuits for measuring spatially varying intensities of beams of low-energy charged particles have been developed. These circuits are intended especially for use in measuring fluxes of ions with spatial resolution along the focal planes of mass spectrometers. Unlike prior mass spectrometer focal-plane detectors, these MOS circuits would not be based on ion-induced generation of electrons, and photons; instead, they would be based on direct detection of the electric charges of the ions. Hence, there would be no need for microchannel plates (for ion-to-electron conversion), phosphors (for electron-to-photon conversion), and photodetectors (for final detection) -- components that degrade spatial resolution and contribute to complexity and size. The developmental circuits are based on linear arrays of charge-coupled devices (CCDs) with associated readout circuitry (see figure). They resemble linear CCD photodetector arrays, except that instead of a photodetector, each pixel contains a capacitive charge sensor. The capacitor in each sensor comprises two electrodes (typically made of aluminum) separated by a layer of insulating material. The exposed electrode captures ions and accumulates their electric charges during signal-integration periods.

Sinha, Mahadeva↗

Optimization of Indium Bump Morphology for Improved Flip Chip Devices

Flip-chip hybridization, also known as bump bonding, is a packaging technique for microelectronic devices that directly connects an active element or detector to a substrate readout face-to-face, eliminating the need for wire bonding. In order to make conductive links between the two parts, a solder material is used between the bond pads on each side. Solder bumps, composed of indium metal, are typically deposited by thermal evaporation onto the active regions of the device and substrate. While indium bump technology has been a part of the electronic interconnect process field for many years and has been extensively employed in the infrared imager industry, obtaining a reliable, high-yield process for high-density patterns of bumps can be quite difficult. Under the right conditions, a moderate hydrogen plasma exposure can raise the temperature of the indium bump to the point where it can flow. This flow can result in a desirable shape where indium will efficiently wet the metal contact pad to provide good electrical contact to the underlying readout or imager circuit. However, it is extremely important to carefully control this process as the intensity of the hydrogen plasma treatment dramatically affects the indium bump morphology. To ensure the fine-tuning of this reflow process, it is necessary to have realtime feedback on the status of the bumps. With an appropriately placed viewport in a plasma chamber, one can image a small field (a square of approximately 5 millimeters on each side) of the bumps (10-20 microns in size) during the hydrogen plasma reflow process. By monitoring the shape of the bumps in real time using a video camera mounted to a telescoping 12 magnifying zoom lens and associated optical elements, an engineer can precisely determine when the reflow of the bumps has occurred, and can shut off the plasma before evaporation or de-wetting takes place.

Jones, Todd J.↗

Optical Link For Readout From Focal-Plane Array

Outputs of photodetectors modulate beam of light. Proposed optical link carries analog readout signals from photodetectors in focal-plane array to external signal-processing circuitry. Insensitive to electromagnetic interference at suboptical frequencies, and imposes smaller heat load on cryogenic apparatus because it does not include high-power electronic amplifier or laser transmitter within cold chamber.

Fossum, Eric R.↗

Development of 3-Phase CCD Timing Generator

Charge-Coupled Devices (CCDs) are used in a wide range of commercial, scientific, and defense applications. They are primarily utilized for imaging and spectroscopic functions. Compact, cost-effective technology to miniaturize the auxiliary electronics required to operate the CCD is highly desirable. Because of the importance of reducing size and weight in defense and space applications, emphasis must be placed on the reduction in size. The purpose of this project is to minimize the CCD timing generator electronics for 3-phase CCDs by replacing conventional ICs with a single programmable IC. This timing generator will give the user the ability to vary the number of horizontal and vertical pixels and to choose between integration and readout modes. This, in turn, will reduce the size and weight of CCD focal plane assemblies as a whole.

Bennett, Kory L.↗

A Program to Detect and Characterize Extra-Solar Giant Planets

We initiated a significant hardware upgrade to the AFOE, to increase its efficiency for precise radial velocity studies to the level where we can continue to contribute usefully to extrasolar planet research on relatively bright stars. The AFOE, at a 1.5-m telescope, will of course not have the sensitivity of radial velocity instruments at larger telescopes, such as the HIRES on Keck or the Hectochelle on the MMT telescope (about to come on line). However, it has been possible to increase its efficiency for precise radial velocity studies by a factor of 4 to 5, which-combined with the large amount of telescope time available at the 1.5-m telescope-will permit us to do intensive follow-up observations of stars brighter than about 8 magnitude. The AFOE was originally designed primarily for asteroseismology using a ThAr reference. This provided useful wavelength stability over tens of minutes as required for asteroseismology, but we were unable to get a long-term (month-to-month) velocity precision better than about 15 m/s with that setup. Hence, we implemented an iodine cell as a wavelength reference for extrasolar planet studies. However, the optical design of the original AFOE did not completely span the wavelength range covered by the iodine absorption spectrum, and furthermore the optics suffered significant light loss through optical obscuration in the camera secondary. To remedy this, we replaced the AFOE grating with a new one that covered the entire iodine spectral range at somewhat lower spectral resolution, and replaced the camera with a transmitting lens. (The use of a lens was made possible by restricting the spectral range covered by the upgraded AFOE to only the iodine region.) These upgrades were successfully completed, and the instrument was tested for three nights in fall of 2002. The expected improvement in sensitivity by a factor of 4 to 5 was observed: that is, the same velocity precision as previously attained (of order 5 to 7 m/s) was now obtained on a stars that are about 4 to 5 times fainter. Unfortunately, just after installing the new AFOE optics, there was a catastrophic failure of the old Tektronix CCD. A careful investigation was made, and it was determined that the failure was probably due to too many thermal cyclings over the previous 8 years. The only solution was to purchase a new CCD. Internal funds of $16,000 were found for this purpose, and the new CCD (a thinned, back-illuminated Marconi 2K x 2K device with 13.5 micron pixels, and employing dual readout channels to keep the readout time as short as 20 seconds) was ordered, has now arrived, and is currently under test before 1 being installed in the AFOE liquid nitrogen dewar. At the same time, we expect to implement new CCD control electronics. This system should be better in many ways than the previous detector (including eliminating the need for UV flashing to maximize the quantum efficiency). We plan to install the detector on the telescope and begin operations again in April of this year.

Lindstrom, David↗

Spaceborne Hybrid-FPGA System for Processing FTIR Data

Progress has been made in a continuing effort to develop a spaceborne computer system for processing readout data from a Fourier-transform infrared (FTIR) spectrometer to reduce the volume of data transmitted to Earth. The approach followed in this effort, oriented toward reducing design time and reducing the size and weight of the spectrometer electronics, has been to exploit the versatility of recently developed hybrid field-programmable gate arrays (FPGAs) to run diverse software on embedded processors while also taking advantage of the reconfigurable hardware resources of the FPGAs.

Bekker, Dmitriy↗

Increasing Linear Dynamic Range of a CMOS Image Sensor

A generic design and a corresponding operating sequence have been developed for increasing the linear-response dynamic range of a complementary metal oxide/semiconductor (CMOS) image sensor. The design provides for linear calibrated dual-gain pixels that operate at high gain at a low signal level and at low gain at a signal level above a preset threshold. Unlike most prior designs for increasing dynamic range of an image sensor, this design does not entail any increase in noise (including fixed-pattern noise), decrease in responsivity or linearity, or degradation of photometric calibration. The figure is a simplified schematic diagram showing the circuit of one pixel and pertinent parts of its column readout circuitry. The conventional part of the pixel circuit includes a photodiode having a small capacitance, CD. The unconventional part includes an additional larger capacitance, CL, that can be connected to the photodiode via a transfer gate controlled in part by a latch. In the high-gain mode, the signal labeled TSR in the figure is held low through the latch, which also helps to adapt the gain on a pixel-by-pixel basis. Light must be coupled to the pixel through a microlens or by back illumination in order to obtain a high effective fill factor; this is necessary to ensure high quantum efficiency, a loss of which would minimize the efficacy of the dynamic- range-enhancement scheme. Once the level of illumination of the pixel exceeds the threshold, TSR is turned on, causing the transfer gate to conduct, thereby adding CL to the pixel capacitance. The added capacitance reduces the conversion gain, and increases the pixel electron-handling capacity, thereby providing an extension of the dynamic range. By use of an array of comparators also at the bottom of the column, photocharge voltages on sampling capacitors in each column are compared with a reference voltage to determine whether it is necessary to switch from the high-gain to the low-gain mode. Depending upon the built-in offset in each pixel and in each comparator, the point at which the gain change occurs will be different, adding gain-dependent fixed pattern noise in each pixel. The offset, and hence the fixed pattern noise, is eliminated by sampling the pixel readout charge four times by use of four capacitors (instead of two such capacitors as in conventional design) connected to the bottom of the column via electronic switches SHS1, SHR1, SHS2, and SHR2, respectively, corresponding to high and low values of the signals TSR and RST. The samples are combined in an appropriate fashion to cancel offset-induced errors, and provide spurious-free imaging with extended dynamic range.

Pain, Bedabrata↗

Electronically Calibratable Clock

Calibration circuit corrects apparent clock rate (ACR) of digital clock without altering oscillator frequency. Calibration circuit does not require iterative adjustments to reference frequency or rate, and correction to ACR is controlled by pushbuttons. Technique is applicable to any timer or counter that counts up to predetermined number then outputs a pulse to a readout register or to control another device.

Davidson, J. R.↗

High-resolution imaging with a two-dimensional resistive anode photon counter

A method to achieve high spatial resolution readout of individual photoelectron events using microchannel plates and a resistive anode is presented. A clamped pair of microchannel plates is used, followed by a gap and a clamped triplet of microchannel plates in cascade to achieve a high stable electron gain of 3 x 10 to the 7th. The gain allows the position determination of each photoelectron event with a very high signal-to-noise ratio. A model consisting of a windowless vacuum-ultraviolet image sensor is presented to demonstrate 500 x 500 pixel images of 50 micron FWHM over a 25-mm circular field of view. The detector offers sufficient speed, sensitivity and resolution for a variety of applications, and the mount design is compatible with planar, remotely-processed, proximity-focused photocathodes.

Firmani, C.↗

Delay Line Detectors for the UVCS and Sumer Instruments on the SOHO Satellite

Microchannel plate based detectors with cross delay line image readout have been rapidly implemented for the SUMER and UVCS instruments aboard the Solar Orbiting Heliospheric Observatory (SOHO) mission to be launched in July 1995. In October 1993 a fast track program to build and characterize detectors and detector control electronics was initiated. We present the detector system design for the SOHO UVCS and SUMER detector programs, and results from the detector test program. Two deliverable detectors have been built at this point, a demonstration model for UVCS, and the flight Ly alpha detector for UVCS, both of which are to be delivered in the next few weeks. Test results have also been obtained with one other demonstration detector system. The detector format is 26mm x 9mm, with 1024 x 360 digitized pixels, using a low resistance Z stack of microchannel plates (MCP's) and a multilayer cross delay line anode (XDL). This configuration provides gains of approximately 2 x 10(exp 7) with good pulse height distributions (less than 50% FWHM) under uniform flood illumination, and background levels typical for this configuration (approximately 0.6 event cm (exp -2)sec(exp -1)). Local counting rates up to about 400 events/pixel/sec have been achieved with no degradation of the MCP gain. The detector and event encoding electronics achieves about 25 millimeter FVHM with good linearity (plus or minus approximately 1 pixel) and is stable to high global counting rates (greater than 4 x 10(exp 5) events sec(exp -1)). Flat field images are dominated by MCP fixed pattern noise and are stable, but the MCP multifiber modulation usually expected is uncharacteristically absent. The detector and electronics have also successfully passed both thermal vacuum and vibration tests.

Seigmund, O. H. W.↗

Electronic strain-level counter

Counter for aircraft counts and records number of times the strain at a point in a structural member exceeds each of four preset levels. Counter uses 28 volt dc power supply, metallic resistance strain gage bridge as sensor, integrated and solid state circuits for signal processing, and electromechanical counters for data storage and readout.

Pitts, F. L.↗

A multiwire proportional counter system for high energy astrophysics

Resolution tests of multiwire proportional counter delay line readout systems are reported. The system is being developed at NASA/JSC for use in a large balloon borne magnet spectrometer. The system is ultimately intended for use in Space Shuttle missions. Tests of two different types of delay line and associated electronics carried out in minimum ionizing particle beams (accelerator and sea level cosmic ray) are reported. Resolution performance is shown to be strongly dependent on type of gas mixture and in the case of inclined events upon the propagation velocity of the delay line. The resolution performance achieved for magic gas chamber filling (100 um at normal incidence) is far superior to any other state of the art technique capable of being applied to large geometry factor systems.

Lacy, J. L.↗