Search NASA⌕ Search

SEARCH · Search NASA

Results for “relative humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Physical Modeling of Coupled Thermohydraulic Behavior of Compacted MX80 Bentonite during Heating

Abstract This paper describes a tank-scale test setup and experimental methodology used to investigate coupled heat transfer and water flow processes during heating of compacted MX80 bentonite to high temperatures. Specifically, a temperature of 200°C was maintained by a cylindrical heating element at the center of a compacted bentonite layer containing an array of temperature, dielectric, and relative humidity sensors. In addition to providing an evaluation of the spatiotemporal variations in temperature, relative humidity, degree of saturation, and global volume, the coupled thermohydraulic properties of the bentonite were assessed. A wetting front was initially observed to move away from the central heater, followed by a drying process until reaching thermohydraulic equilibrium. The soil–water retention curve (SWRC) of the bentonite followed a wetting scanning path before following the primary drying path exhibiting a shift in water retention with elevated temperature. Results from the tank-scale test can be used for validation of numerical simulations of drying processes in the engineered barrier system of a high-level radioactive waste geological disposal repository and confirm that a temperature-dependent hysteretic SWRC with scanning paths is required to accurately capture the bentonite response.

Engineering↗

High-Resolution South American Wind Resource Data Downscaled with Generative Machine Learning Conditioned on Near-Surface Observations

High-resolution historical wind data was developed for the entirety of South America using the innovative Super-Resolution for Renewable Resource Data (sup3r) machine learning framework. The publicly available Sup3rWind South America dataset represents a significant advancement in wind resource data generation, leveraging generative machine learning conditioned on near-surface observations from the Meteorological Assimilation Data Ingest System (MADIS) to efficiently and accurately downscale coarse reanalysis data from the European Centre for Medium-Range Weather Forecasts (ERA5). This approach produces fine-scale, spatially and temporally coherent wind and meteorological fields hundreds of times more computationally efficient than traditional numerical weather modeling methods, enabling access to high-fidelity wind information across both continental and offshore regions. Sup3rWind South America builds on the earlier Sup3rWind Ukraine dataset through improvements in model architecture and outputs conditioned on near-surface observation inputs. As with the Ukraine data release, this dataset includes wind speed, wind direction, temperature, relative humidity, and pressure at a horizontal resolution of ~2 km, representing a 15x spatial enhancement relative to the 31 km ERA5 grid. Wind speed and direction are provided at 5-minute resolution, a 12x temporal refinement compared to the hourly ERA5 data, while temperature, relative humidity, and pressure remain at hourly resolution. The data covers all years from 2005 to 2024. Before downscaling, ERA5 inputs were bias-corrected using long-term monthly means and a limited number of quality-controlled observations to align large-scale statistics with regional conditions. The resulting dataset is the first publicly available high-resolution timeseries wind record that provides full spatial coverage of South America. Model validation demonstrates strong agreement with observations across several statistical metrics, consistent with other state-of-the-art high-resolution wind resource datasets. The potential applications of Sup3rWind South America span renewable energy resource assessment, energy system modeling, and grid resilience analysis. The 20-year record and high spatial and temporal resolution support accurate estimation of long-term energy yield and the economic feasibility of potential wind development sites. Continuous coverage across both continental and offshore regions enables comprehensive site prospecting within exclusive economic zones. The 2 km, 5-minute resolution data provide the spatial and temporal variability required for power system simulation, operational planning, and regional risk assessments.

17 WIND ENERGY↗

Quaternary Ammonium-Functionalized Poly(Arylene Ether Sulfone) Random Copolymers for Direct Air Capture

Direct air capture (DAC) is a promising tool for reducing CO 2 concentrations in the atmosphere and fighting climate change. We synthesized a series of quaternary ammonium (QA) functionalized poly(arylene ether sulfone) copolymers with varying mole fractions of charge content and demonstrated their potential as sorbents for DAC. Molecular weight analysis determined high monomer conversion was achieved in <6 h and relatively high molecular weights for all copolymer compositions. Thermal analysis revealed all polymers had degradation temperatures >240 °C and a single glass transition temperature (T g ); the T g decreased with an increase in ion exchange capacity (IEC). Fractional free volume and water uptake percentage increased and water contact angle decreased with the number of QA sites when compared to a neutral, commercially available polysulfone (Udel® P-1700 PSU). Next, the novel series of ammonium-functionalized copolymers exhibited a moisture-mediated capture and release of atmospheric CO 2 . When exposed to air containing 30% relative humidity the polymers captured CO 2 and the capacity increased with the IEC. When the relative humidity was increased to 95% the samples released the CO 2 . This study demonstrates a promising CO 2 DAC sorbent and highlights the possibility for continuous DAC with purpose-built free-standing membranes.

42 ENGINEERING↗

Surface ozone and meteorological variables at CoURAGE TBS site during summer IOP

This dataset provides continuous near ground-level in situ ozone and meteorological data at the TBS site (S7) during the CoURAGE summer IOP. The ozone inlet and the weather station were approximately 5 meters above the surface. In situ ozone (ppbv) was collected with a 2BTech Model 205 dual beam ozone monitor. The meteorological data (temperature, pressure, relative humidity, wind speed, and wind direction) was collected with an AIRMAR 220WX WeatherStation Instrument with relative humidity (RH) module. The data has 2-second temporal resolution.

bar_pres↗

Delayed darkening of radiation-exposed radiochromic dye dosimeters

Experiments have verified the existence of considerable delayed darkening in FWT-60 dosimetry films that may, depending on relative humidity, last for several hours. The amount of delayed darkening depends very strongly on the relative humidity at which the films are equilibrated before irradiation. It is pointed out that the delayed darkening effect must be taken into account before any meaningful dosimetric measurements may be made using these nylon-based thin dosimetry films. The particular radiation-sensitive compound used in the FWT-60 films is the hexahydrosyethyl pararosanaline cyanide with the Dupont nylon resin, Elvamide 8061, which forms the host matrix of a solid-state solution.

Danchenko, V.↗

Mixed Layers and Satellite Retrievals

As part of the process to determine whether it is possible to retrieve boundary layer structure with the current sounding techniques, temperature retievals were performed for radiosonde profiles that showed temperature inversions. It was found that when temperature inversions exceed 8 to 10 C a retrieval will indeed show a temperature increase with height over a limited vertical distance. For weaker inversions retrieved temperatures are generally smoothly decreasing with height. It is, however, impossible to determine the actual mixed layer height from the retrievals. Whether the water vapor channels could be used in observing mixed layer structure was investigated. Temperature inversions are accompanied by significant drops in relative humidity. While this effect is very pronounced in parts of the trade wind regimes with relative humidity drops of up to 60%, it is widespread in other areas of the ocean as well. A simulation experiment was performed in which brightness temperatures were computed for smooth temperature and humidity profiles and compared with those computed from inversion profiles.

Boers, R.↗

Parameterizations of Depositional Growth of Cloud Ice in a Bulk Microphysical Scheme

Two aspects of the cloud ice parameterization in the Goddard Cumulus Ensemble Model cloud physics parameterization are examined: the conversion of cloud ice to snow by depositional growth, designated PSFI, and the saturation adjustment scheme. The original formulation of PSFI is shown to produce excessive conversion of cloud ice to snow because of an implicit assumption that the relative humidity is 100% with respect to water even though the air may actually be quite less humid. Two possible corrections to this problem are proposed, the first involving application of a relative humidity dependent correction factor to the original formulation of PSFI, and the second involving a new formulation of PSFI based on the equation for depositional growth of cloud ice. The sensitivity of these formulations of PSFI to the assumed masses of the ice particles is examined. Possible problems associated with using a saturation adjustment scheme for cloud ice are discussed and simulations of a squall line with and without application of the adjustment scheme for ice are compared.

Braun, Scott A.↗

Parameterizations of Depositional Growth of Cloud Ice in a Bulk Microphysical Scheme

The conversion of cloud ice to snow by depositional growth, designated P(sub SFI), in the Goddard Cumulus Ensemble Model cloud physics parameterization is examined. The original formulation of P(sub SFI) is shown to produce excessive conversion of cloud ice to snow because of an implicit assumption that the relative humidity is 100% with respect to water even though the air may actually be quite less humid. Two possible corrections to this problem are proposed, the first involving application of a relative humidity dependent correction factor to the original formulation of P(sub SFI), and the second involving a new formulation of P(sub SFI) based on the equation for depositional growth of cloud ice.

Braun, Scott A.↗

Space flight printed wiring board measling investigation

A flight printed wiring board (PWB) for a satellite project was observed to have a high incidence of measling. Other PWB's produced for the program by the same manufacturer did not exhibit the degree of measling as did the 'measle-prone' board. Measling susceptibility during hand soldering and measling effects on PWB insulation resistance were investigated for three production PWB's. Measling resistance was significantly different between the three boards: the 'worst' exhibited five times the number of measles as the 'best' board. 'Severe' measling (that which is likely to affect board reliability) did not exist on the 'best' board, even under extreme soldering conditions (399 degrees C for 12-15 sec.), whereas the 'worst' board showed an average of one 'severe' measle for every two pads under more normal soldering conditions (288-343 degrees C for 2-5 sec.). Both soldering time and temperature affected measling, with time having a slightly greater influence (2 percent versus 12 percent). Measling effects on PWB insulation resistance were inconclusive. These were evaluated by in situ resistance measurements on the same three boards at elevated temperature and humidity. The measured resistance for all three boards decreased for exposures greater than 50 degrees C and 50 percent relative humidity. The 'measle-prone' board showed a resistance decrease at only 25 degrees C and 50 percent relative humidity. However, no definitive difference was detected between measled and not-measled (control) samples. The boards evaluated were production boards, so the effect of interlayer traces connecting the plated-through holes was not controlled. It is likely the resistance measurements were over different volumes of PWB laminate, which would account for the widely varying resistances measured. Thermomechanical measurements on board laminate materials did not reveal any differences attributed to measling. Differences in glass transition temperature were significantly different when measured by DTA, but not by SDT. Laminate thermal expansion differences were significant for the 35 degrees C evaluations, but not for any higher temperatures.

Thomas, Walter B., III↗

Trajectory Simulations of Upper Tropospheric Humidity

We present comparisons of simulations of upper tropospheric humidity at 215 and 146 hPa with satellite measurements. Our model uses diabatic trajectories to advect water vapor from an initial condition of 100% relative humidity to the final state. The model does not allow parcels' relative humidity to exceed 100%, and in this way crudely incorporates condensation. We find that this simple model does a good job of simulating the observations. Sensitivity studies suggest that one must have realistic wind velocities in order to accurately simulate the humidity distribution; microphysical parameterizations seem to be less important. Comparisions between simulations using UKMO and NCEP horizontal winds will be discussed.

Dessler, A. E.↗

Anomalous swelling behavior of FM 5055 carbon phenolic composite

The swelling response of a typical carbon phenolic composite was measured in the three primary material directions. The data obtained sugrest that at low and high relative humidities the incremental increase in moisture absorption can be attributed primarily to the resin. At intermediate relative humidities, the water is moving largely into the carbonized fibers.

Stokes, E. H.↗

Measuring Moisture Levels in Graphite Epoxy Composite Sandwich Structures

Graphite epoxy composite (GEC) materials are used in the construction of rocket fairings, nose cones, interstage adapters, and heat shields due to their high strength and light weight. However, they absorb moisture depending on the environmental conditions they are exposed to prior to launch. Too much moisture absorption can become a problem when temperature and pressure changes experienced during launch cause the water to vaporize. The rapid state change of the water can result in structural failure of the material. In addition, heat and moisture combine to weaken GEC structures. Diffusion models that predict the total accumulated moisture content based on the environmental conditions are one accepted method of determining if the material strength has been reduced to an unacceptable level. However, there currently doesn t exist any field measurement technique to estimate the actual moisture content of a composite structure. A multi-layer diffusion model was constructed with Mathematica to predict moisture absorption and desorption from the GEC sandwich structure. This model is used in conjunction with relative humidity/temperature sensors both on the inside and outside of the material to determine the moisture levels in the structure. Because the core materials have much higher diffusivity than the face sheets, a single relative humidity measurement will accurately reflect the moisture levels in the core. When combined with an external relative humidity measurement, the model can be used to determine the moisture levels in the face sheets. Since diffusion is temperaturedependent, the temperature measurements are used to determine the diffusivity of the face sheets for the model computations.

Nurge, Mark↗

Development of Mission Profiles for Humidity Models in the Reliability Testing of PV Inverters: Preprint

To understand the impacts of humidity on PV inverters, mission profiles were developed to accurately describe the different processes and rates based on the environmental factors of temperature, relative humidity, and irradiance. The operating environment of the device introduces stress factors dependent on component temperature, relative humidity, and component voltage. The development of profiles started from looking at historical climate conditions at Cocoa, Florida, a hot and humid location. The profile developed from field location was compared with existing humidity test profiles in industrial and military standards to determine acceleration factors. Prior to the evaluation of the mission profiles, critical components in the PV inverter were identified based on vendor discussions along with failure modes of interest. The profiles considered in this study was demonstrated using a 4-kVA string inverter. The measurements from the devices were substituted in device manufacturer specified equation to determine the severity of each test. The severity of each test was compared against the severity of the 24-hour result to determine the acceleration factor of each test. The acceleration factors were determined to be over a range of 1.2-6 for the existing humidity tests from standards, when compared against the mission profile developed from field data. This optimal humidity/thermal profile will be passed to the IEC standards development for inverter qualification testing.

humidity models↗

Occurrence of Ice Supersaturations, Ice Clouds, and Ternary Aerosols in the Arctic Lowermost Stratosphere

Relative humidity, aerosol concentration, and ice crystals all have important impacts on chemistry and radiative transfer in the lowermost stratosphere. In this study, we have combined SOLVE measurements with meteorological analyses to investigate the statistics of humidity, aerosols, and clouds in the arctic lower stratosphere. First, we will present a statistical analysis of relative humidity with respect to ice in the lowermost stratosphere, used on the DC-8 in situ measurements. We will show examples of ice supersaturation well within the stratosphere. Generally, these cases were associated with extremely low temperatures near the tropopause. Next, we will discuss the climatological occurrence frequency of tropopause temperatures low enough for ice saturation even with typically low stratospheric water vapor mixing ratios. Really, we will examine case studies of ice clouds observed in the lowermost stratosphere during SOLVE. We will discuss the possible origin of these clouds (i.e., precipitation from higher type II PSCs, injection of tropospheric air into the lower stratosphere, etc.).

Jensen, Eric↗

Emissions of an AVCO Lycoming 0-320-DIAD air cooled light aircraft engine as a function of fuel-air ratio, timing, and air temperature and humidity

A carbureted aircraft engine was operated over a range of test conditions to establish the exhaust levels over the EPA seven-mode emissions cycle. Baseline (full rich production limit) exhaust emissions at an induction air temperature of 59 F and near zero relative humidity were 90 percent of the EPA standard for HC, 35 percent for NOx, and 161 percent for CO. Changes in ignition timing around the standard 25 deg BTDC from 30 deg BTDC to 20 deg BTDC had little effect on the exhaust emissions. Retarding the timing to 15 deg BTDC increased both the HC and CO emissions and decreased NOx emissions. HC and CO emissions decreased as the carburetor was leaned out, while NOx emissions increased. The EPA emission standards were marginally achieved at two leanout conditions. Variations in the quantity of cooling air flow over the engine had no effect on exhaust emissions. Temperature-humidity effects at the higher values of air temperature and relative humidity tested indicated that the HC and CO emissions increased significantly, while the NOx emissions decreased.

Meng, P. R.↗

Model for Humidity-Mediated Diffusion on Aluminum Surfaces and Its Role in Accelerating Atmospheric Aluminum Corrosion

Bare aluminum metal surfaces are highly reactive, which leads to the spontaneous formation of a protective oxide surface layer. Because many subsequent corrosive processes are mediated by water, the structure and dynamics of water at the oxide interface are anticipated to influence corrosion kinetics. Here, using molecular dynamics simulations with a reactive force field, we model the behavior of aqueous aluminum metal ions in water adsorbed onto aluminum oxide surfaces across a range of ion concentrations and water film thicknesses corresponding to increasing relative humidity. We find that the structure and diffusivity of both the water and the metal ions depend strongly on the humidity of the environment and the relative height within the adsorbed water film. Aqueous aluminum ion diffusion rates in water films corresponding to a typical indoor relative humidity of 30% are found to be more than 2 orders of magnitude slower than self-diffusion of water in the bulk limit. Connections between metal ion diffusivity and corrosion reaction kinetics are assessed parametrically with a reductionist model based on a 1D continuum reaction–diffusion equation. Our results highlight the importance of incorporating the properties specific to interfacial water in predictive models of aluminum corrosion.

36 MATERIALS SCIENCE↗

Continuous sensor suite measurements of weather, energy, soil and flux at four PumpHouse sites at the East River, Colorado

The purpose of this package is to monitor energy and water fluxes using a comprehensive set of sensors integrated on a tripod set up at 4 locations at the East River watershed in Colorado in the Upper Colorado River Basin as part of the Scientific Focus Area (SFA) research led by the Lawrence Berkeley National Lab (LBNL). This is a continuous sensor suite measurements of weather, energy, soil and flux at four East River pumphouse sites (ER-PHS1, ER-PHS2, ER-PHS3 and ER-PHS4) include: (1) soil CO2 concentration, CO2 flux and heat flux from soil surface; (2) photosynthetic active radiation flux at 1 m; (3) incoming/outcoming short and long wave radiation at 1 m, and user calculated net short and long wave radiation; (4) oxygen concentration and surface infrared temperature; (5) soil volumetric water content, temperature, and electrical conductivity at 10, 30, 60, 115 cm depth 115 cm depth; (6) soil matric potential and temperature at 30 cm depth; (7) incoming short wave radiation at 3 m height; (8) rainfall precipitation; (9) lightning strikes and strike distances; (10) wind direction and speed, maximum wind gust at 3 m; (11) air temperature, vapor pressure and barometric pressure at 3 m; (12) X _axis_level and Y_axis_level_(degree), tilt of the ATMOS 41 sensor; (13) maximum rainfall rate; (14) relative humidity sensor temperature at 3 m; (15) internally calculated vapor pressure deficit at 3 m with vapor pressure, relative humidity and sensor temperature measurements; (16) user calculated vapor pressure.These datasets contain data from Oct 11 2019 to March 20, 2020, and new datasets will be updated on annual basis. Files uploaded in Excel and Word, with copies in csv and pdf format.

54 ENVIRONMENTAL SCIENCES↗

Sensible and latent heat flux estimates in Antarctica

The assumption has been made that the net annual contribution of water by the processes of deposition and sublimation to the Antarctic Ice Sheet is zero. The U.S. Antarctic Program started installing reliable automatic weather stations on the Antarctic Continent in 1980. The initial units were equipped to measure wind speed, wind direction, air pressure, and air temperature. During the 1983-1984 field season in Antarctica, three units were installed that measured a vertical air temperature difference between the nominal heights of 0.5 m and 3.0 m and relative humidity at a nominal height of 3 m. The measurements of the vertical air temperature difference and the relative humidity are the minimum required to estimate the sensible and latent heat fluxes to the air, while not exceeding the available energy requirements for the weather stations. The estimates of the net annual sublimation and deposition on the Ross Ice Shelf amount to 20 to 80 percent of the annual accumulation. We conclude that the assumption that annual sublimation and deposition are zero is not valid under Antarctic conditions.

Stearns, Charles R.↗