Search NASA⌕ Search

SEARCH · Search NASA

Results for “scan pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

One-Dimensional Scanning Approach to Shock Sensing

Measurement tools for high speed air flow are sought both in industry and academia. Particular interest is shown in air flows that exhibit aerodynamic shocks. Shocks are accompanied by sudden changes in density, pressure, and temperature. Optical detection and characterization of such shocks can be difficult because the medium is normally transparent air. A variety of techniques to analyze these flows are available, but they often require large windows and optical components as in the case of Schlieren measurements and/or large operating powers which precludes their use for in-flight monitoring and applications. The one-dimensional scanning approach in this work is a compact low power technique that can be used to non-intrusively detect shocks. The shock is detected by analyzing the optical pattern generated by a small diameter laser beam as it passes through the shock. The optical properties of a shock result in diffraction and spreading of the beam as well as interference fringes. To investigate the feasibility of this technique a shock is simulated by a 426 m diameter optical fiber. Analysis of results revealed a direct correlation between the optical fiber or shock location and the beam s diffraction pattern. A plot of the width of the diffraction pattern vs. optical fiber location reveals that the width of the diffraction pattern was maximized when the laser beam is directed at the center of the optical fiber. This work indicates that the one-dimensional scanning approach may be able to determine the location of an actual shock. Near and far field effects associated with a small diameter laser beam striking an optical fiber used as a simulated shock are investigated allowing a proper one-dimensional scanning beam technique.

Tokars, Roger↗

Advances in Scanning Reflectarray Antennas Based on Ferroelectric Thin Film Phase Shifters for Deep Space Communications

Though there are a few examples of scanning phased array antennas that have flown successfully in space, the quest for low-cost, high-efficiency, large aperture microwave phased arrays continues. Fixed and mobile applications that may be part of a heterogeneous exploration communication architecture will benefit from the agile (rapid) beam steering and graceful degradation afforded by phased array antennas. The reflectarray promises greater efficiency and economy compared to directly-radiating varieties. Implementing a practical scanning version has proven elusive. The ferroelectric reflectarray, under development and described herein, involves phase shifters based on coupled microstrip patterned on Ba(x)Sr(1-x)TiO3 films, that were laser ablated onto LaAlO3 substrates. These devices outperform their semiconductor counterparts from X- through and K-band frequencies. There are special issues associated with the implementation of a scanning reflectarray antenna, especially one realized with thin film ferroelectric phase shifters. This paper will discuss these issues which include: relevance of phase shifter loss; modulo 2(pi) effects and phase shifter transient effects on bit error rate; scattering from the ground plane; presentation of a novel hybrid ferroelectric-semiconductor phase shifter; and the effect of mild radiation exposure on phase shifter performance.

Romanofsky, Robert R.↗

Inspection of Space Station Cold Plate Using Visual and Automated Holographic Techniques

Real-time holography has been used to confirm the presence of non-uniformity in the construction of an International Space Station cold plate. Ultrasonic C-scans have previously shown suspected areas of cooling fin disbonds. But both neural-net processed and visual holography did not evidence any progressive permanent changes resulting from 3000 pressurization and relaxation cycles of a Dash 8 cold plate. Neural-net and visual inspections were performed of characteristic patterns generated from electronic time-average holograms of the vibrating cold plate. Normal modes of vibration were excited at very low amplitudes for this purpose, The neural nets were trained to flag very small changes in the mode shapes as encoded in the characteristic patterns. Both the whole cold plate and a zoomed region were inspected. The inspections were conducted before, after, and during pressurization and relaxation cycles of the cold plate. A water-filled cold plate was pressurized to 120 psig (827 kPa) and relaxed for each cycle. Each cycle required 5 seconds. Both the artificial neural networks and the inspectors were unable to detect changes in the mode shapes of the relaxed cold plate. The cold plate was also inspected visually using real-time holography and double-exposure holography. Regions of non-uniformity correlating with the C-scans were apparent, but the interference patterns did not change after 3000 pressurization and relaxation cycles. These tests constituted the first practical application of a neural-net inspection technique developed originally with support from the Director's Discretionary Fund at the Glenn Research Center at Lewis Field.

Decker, Arthur J.↗

Use of the VAS water vapor imagery to analyze upper-level flow patterns

Infrared (IR) channels which are available and are developed for operational use were examined. The Visible Infrared Spin-Scan Radiometer (VISSR) Atmospheric Sounder (VAS) was launched. This instrument has a radiometer consisting of the standard visible channel detectors and six thermal detectors that detect IR radiation in 12 spectral bands. Any one of the 11 new IR channels can be substituted for the standard 11.5 micro m window channel when the satellite is operating in the standard VISSP mode and provides data in image form through the GOES distribution system.

Anderson, R. K.↗

The 20 GHz proof-of-concept test model results for a multiple scan beam dual reflector antenna

A full scale 20 GHz antenna model was designed, fabricated and tested. The model is intended to test the low sidelobe beam scanning capability of a new class of an offset dual reflector and feed array configuration. The offset main reflector and subreflector surfaces are custom shaped by a computer synthesis procedure. The derived optics result in beam scan loss under 1 db over the + or - 12.3 beamwidths by + or - 5.8 beamwidths scan volume while maintaining low sidelobes. It is found that the measured and computed patterns are in good agreement.

Roberts, T.↗

Antenna Beam Coverage Concepts

The strawman Personal Access Satellite System (PASS) design calls for the use of a CONUS beam for transmission between the supplier and the satellite and for fixed beams for transmission between the basic personal terminal and the satellite. The satellite uses a 3 m main reflector for transmission at 20 GHz and a 2 m main reflector for reception at 30 GHz. There are several types of spot beams under consideration for the PASS system besides fixed beams. The beam pattern of a CONUS coverage switched beam is shown along with that of a scanning beam. A switched beam refers to one in which the signal from the satellite is connected alternatively to various feed horns. Scanning beams are taken to mean beams whose footprints are moved between contiguous regions in the beam's coverage area. The advantages and disadvantages of switched and/or scanning beams relative to fixed beams. The consequences of using switched/scanning in lieu of fixed beams in the PASS design and attempts are made to evaluate the listed advantages and disadvantages. Two uses of switched/scanning beams are examined. To illustrate the implications of switched beams use on PASS system design, operation at two beam scan rates is explored.

Estabrook, Polly↗

Infrared Images

Earth objects emit natural radiation invisible to the unaided human eye, but visible to infrared scanning devices such as the device developed by Inframetrics, Inc. Such devices serve a number of purposes ranging from detection of heat loss in buildings for energy conservation measures, to examining heat output of industrial machinery for trouble shooting and preventive maintenance. Representative of system is Model 525, a small, lightweight field instrument that scans infrared radiation and translates its findings to a TV picture of the temperature pattern in the scene being viewed. An accessory device permits viewing the thermal radiation in color.

Source record↗

Making The Invisible Visible

In public and private archives throughout the world there are many historically important documents that have become illegible with the passage of time. They have faded, been erased, acquired mold, water and dirt stain, suffered blotting or lost readability in other ways. While ultraviolet and infrared photography are widely used to enhance deteriorated legibility, these methods are more limited in their effectiveness than the space-derived image enhancement technique. The aim of the JPL effort with Caltech and others is to better define the requirements for a system to restore illegible information for study at a low page-cost with simple operating procedures. The investigators' principle tools are a vidicon camera and an image processing computer program, the same equipment used to produce sharp space pictures. The camera is the same type as those on NASA's Mariner spacecraft which returned to Earth thousands of images of Mars, Venus and Mercury. Space imagery works something like television. The vidicon camera does not take a photograph in the ordinary sense; rather it "scans" a scene, recording different light and shade values which are reproduced as a pattern of dots, hundreds of dots to a line, hundreds of lines in the total picture. The dots are transmitted to an Earth receiver, where they are assembled line by line to form a picture like that on the home TV screen.

Source record↗

Collocation and Pattern Recognition Effects on System Failure Remediation

Previous research found that operators prefer to have status, alerts, and controls located on the same screen. Unfortunately, that research was done with displays that were not designed specifically for collocation. In this experiment, twelve subjects evaluated two displays specifically designed for collocating system information against a baseline that consisted of dial status displays, a separate alert area, and a controls panel. These displays differed in the amount of collocation, pattern matching, and parameter movement compared to display size. During the data runs, subjects kept a randomly moving target centered on a display using a left-handed joystick and they scanned system displays to find a problem in order to correct it using the provided checklist. Results indicate that large parameter movement aided detection and then pattern recognition is needed for diagnosis but the collocated displays centralized all the information subjects needed, which reduced workload. Therefore, the collocated display with large parameter movement may be an acceptable display after familiarization because of the possible pattern recognition developed with training and its use.

Trujillo, Anna C.↗

Instrument scanning and controlling: Using eye movement data to understand pilot behavior and strategies

Eye movement data and other parameters including instrument readings, aircraft state and position variables, and control maneuvers were recorded while pilots flew ILS simulations in a B 737. The experiment itself employed seven airline pilots, each of whom flew approximately 40 approach/landing sequences. The simulator was equipped with a night visual scene but the scene was fogged out down to approximately 60 meters (200 ft). The instrument scanning appeared to follow aircraft parameters not physical position of instruments. One important implication of the results is: pilots look for categories or packets of information. Control inputs were tabulated according to throttle, wheel position, column, and pitch trim changes. Three seconds of eye movements before and after the control input were then obtained. Analysis of the eye movement data for the controlling periods showed clear patterns. The results suggest a set of miniscan patterns which are used according to the specific details of the situation. A model is developed which integrates scanning and controlling. Differentiations are made between monitoring and controlling scans.

Dick, A. O.↗

Characterization of an advanced focal plane for multispectral linear array (MLA) application

It is pointed out that the MLA instrument represents the next generation in the Landsat series of earth resources satellites. The MLA sensor concept utilizes a pushbroom scan mode to eliminate electromechanical scan mirrors, and the lower reliabililty and higher power dissipation which accompany their employment. The pushbroom scanner makes use of a linear array which consists generally of thousands of detectors oriented perpendicular to the along-track direction of the satellite. Test techniques have been developed for the measurement of the module parameters which are critical to MLA focal plane performance. These measurements include the determination of infrared responsivity, linearity over the dynamic range, temporal noise, and fixed pattern effects on each detector element of each module tested. Tests related to spectral response, crosstalk, and spot scan profiles are also conducted. A description is provided of the test equipment involved.

King, P.↗

Analysis of atmosphere-sea ice interactions in the Arctic basin using ESMR microwave data

Data from the Electrically Scanning Microwave Radiometer (ESMR) on Nimbus-5 are used to determine the spatial and temporal patterns of change in microwave brightness signatures of Arctic sea ice during a full annual cycle (1973/74). Interactions of ice conditions with the atmosphere are examined using grid point data for surface air temperature and atmospheric pressure. Principal components analysis is used to examine the major elements present in the microwave and atmospheric data. Component scores from these analyses are then used in a canonical correlation analysis to determine interassociations present between the ice and atmosphere in the Beaufort Sea and the European sectors on a synoptic time scale. The synoptic weather conditions associated with the pattern of snow melt on the ice in spring 1974 are described, and a clarification of possible alternative interpretations of features identified as polynyi occurring at 80-85 deg N during the late summer 1974 is presented.

Crane, R. G.↗

Zirconium fluoride glass - Surface crystals formed by reaction with water

The hydrated surfaces of a zirconium barium fluoride glass, which has potential for application in optical fibers and other optical elements, were observed by scanning electron microscopy. Crystalline zirconium fluoride was identified by analysis of X-ray diffraction patterns of the surface crystals and found to be the main constituent of the surface material. It was also found that hydrated zirconium fluorides form only in highly acidic fluoride solutions. It is possible that the zirconium fluoride crystals form directly on the glass surface as a result of its depletion of other ions. The solubility of zirconium fluoride is suggested to be probably much lower than that of barium fluoride (0.16 g/100 cu cm at 18 C). Dissolution was determined to be the predominant process in the initial stages of the reaction of the glass with water. Penetration of water into the glass has little effect.

Doremus, R. H.↗

A V-grooved AlGaAs/GaAs passivated PN junction

A passivated, V-grooved GaAs solar cell offers important advantages in terms of improved optical coupling, higher short circuit current, and increased tolerance to particle radiation when compared to the planar cell configuration. An AlGaAs epilayer has been deposited on a p-type GaAs epilayer grown on an n-type V-grooved GaAs surface using MOCVD. A wet chemical etching process was used to produce a V-pattern with a 7.0 micron periodicity. Reflectivity measurements substantiate the expected decrease in solar reflectance. Scanning electron microscopy techniques were used to confirm the presence of the AlGaAs layer and verify the existence of a pn junction.

Bailey, Sheila G.↗

A V-grooved AlGaAs/GaAs passivated pn junction

A passivated, V-grooved GaAs solar cell offers important advantages in terms of improved optical coupling, higher short-circuit current, and increased tolerance to particle radiation when compared to the planar cell configuration. An AlGaAs epilayer has been deposited on a p-type GaAs epilayer grown on an n-type V-grooved GaAs surface using MOCVD. A wet chemical etching process was used to produce a V-pattern with a 7.0-micron periodicity. Reflectivity measurements substantiate the expected decrease in solar reflectance. Scanning electron microscopy techniques were used to confirm the presence of the AlGaAs layer and verify the existence of a pn junction.

Bailey, S. G.↗

Exploratory geological analysis of AVIRIS data

The size and complexity of AVIRIS data sets makes analysis difficult. We present a technique that allows the researcher to rapidly scan the full data set in image form in order to empirically find significant spatial patterns anywhere across the spectrum. Our approach takes advantage of the speed and power of computer graphics workstations to allow real-time, interactive data manipulation and display. Empirical data selection avoids the bias inherent in theoretical selection criteria, and allows discovery of unexpected relationships within the data set. Link Winds, a prototype data analysis system under development, provides the visualization tools used in this study. We are applying this approach to geological studies in the eastern Mojave Desert.

Beratan, K. K.↗

The Impact of the Sun on Passive Remote Sensing at L-band

The sun is a strong source of radiation at L-band behaving roughly like a thermal source with a temperature ranging between 10(exp 5) - 10(exp 7) K, depending on solar activity. This is an important consideration at 1.4 GHz (the window set aside for passive use only) where future satellite sensors will operate to monitor soil moisture and sea surface salinity (e.g. SMOS, Aquarius, and Hydros). Straight forward calculations show that such a source of radiation can be a significant issue for these remote sensing applications, especially in the case of remote sensing of sea surface salinity. Radiation from the sun impacts passive remote sensing systems in several ways. First, is the solar radiation that comes directly from the sun (line-of-sight from sun to spacecraft that enters the radiometer through antenna side lobes). This is a particular problem for sensors in sunsynchronous orbits near the terminator (e.g. orbits with equatorial crossing times near 6am/6pm) because the spacecraft is in the sun most of the time. Second, is solar radiation that is reflected (specularly) from the mean surface to the radiometer. This contribution can be nearly as large as the direct ray, especially when the reflection is from the ocean surface which has a high reflection coefficient. Finally, there is "incoherent" signal reflected from the surface structure (roughness) to the radiometer antenna. Examples illustrating the significance of these terms is presented for the case of a pushbroom radiometer such as Aquarius and a conically scanning radiometer such as proposed for Hydros. Calculations are made using a set of theoretical patterns for these beams together with data on solar radiation obtained from by a worldwide network of observing stations known as Radio Solar Telescope Network (RSTN). Near solar minimum, solar contamination is not a problem unless the sun enters near the main beam. But near solar maximum, account must be made for radiation from the sun even when the signal enters in sidelobes far from the main beam.

LeVine, David M.↗

Dtest Testing Software

This software runs a suite of arbitrary software tests spanning various software languages and types of tests (unit level, system level, or file comparison tests). The dtest utility can be set to automate periodic testing of large suites of software, as well as running individual tests. It supports distributing multiple tests over multiple CPU cores, if available. The dtest tool is a utility program (written in Python) that scans through a directory (and its subdirectories) and finds all directories that match a certain pattern and then executes any tests in that directory as described in simple configuration files.

Jain, Abhinandan↗