Search NASA⌕ Search

SEARCH · Search NASA

Results for “security framework”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Towards a more holistic sustainability assessment framework for agro-bioenergy systems — A review

The use of life cycle assessment (LCA) as a sustainability assessment tool for agro-bioenergy system usually has an industrial agriculture bias. Furthermore, LCA generally has often been criticized for being a decision maker tool which may not consider decision takers perceptions. They are lacking in spatial and temporal depth, and unable to assess sufficiently some environmental impact categories such as biodiversity, land use etc. and most economic and social impact categories, e.g. food security, water security, energy security. This study explored tools, methodologies and frameworks that can be deployed individually, as well as in combination with each other for bridging these methodological gaps in application to agro-bioenergy systems. Integrating agronomic options, e.g. alternative farm power, tillage, seed sowing options, fertilizer, pesticide, irrigation into the boundaries of LCAs for agro-bioenergy systems will not only provide an alternative agro-ecological perspective to previous LCAs, but will also lead to the derivation of indicators for assessment of some social and economic impact categories. Deploying life cycle thinking approaches such as energy return on energy invested-EROEI, human appropriation of net primary production-HANPP, net greenhouse gas or carbon balance-NCB, water footprint individually and in combination with each other will also lead to further derivation of indicators suitable for assessing relevant environmental, social and economic impact categories. Also, applying spatio-temporal simulation models has a potential for improving the spatial and temporal depths of LCA analysis.

54 ENVIRONMENTAL SCIENCES↗

INTEGRATION OF FLEX EQUIPMENT AND OPERATOR ACTIONS IN PLANT FORCE-ON-FORCE MODELS WITH DYNAMIC RISK ASSESSMENT

The overall operation and maintenance cost to protect nuclear power plants accounts for approximately 7% of the total cost of power generation, with labor accounting for half of this cost. In the current research, from interaction with utilities and other stakeholders, it was determined that physical security forces account for nearly 20% of the entire workforce at several nuclear power plants. Labor costs continue to rise in the U.S., so any measures to reduce the cost of operating a nuclear power plant will need to include a reduction in labor. The physical security pathway within the DOE’s Light Water Reactor Sustainability program aims to lower the cost of physical security through directed research into modeling and simulation, application of advanced sensors or deployment of advanced weapons. This report presents a modeling and simulation framework for integrating Diverse and Flexible Mitigation Capability (FLEX) portable equipment performance with Force on Force models of a plant’s physical security posture. The generic framework is described in detail, followed by a case study of modeling an adversarial attack aimed at causing a radiological release by sabotaging the plant’s power supply and its ultimate heat sink capabilities at a hypothetical nuclear power plant. Two different FLEX deployment strategies, series and parallel, are modeled with distinct timelines. The results of the adversarial attack modeled in a commercial Force on Force tool are integrated with the FLEX deployment model in INL’s dynamic modeling tool EMRALD. Monte Carlo simulation is used to model the distribution of the timeline in FLEX deployment strategies. The results demonstrate that, even in the extreme case of a successful adversarial attack, deployment of FLEX equipment can result in a significantly high likelihood of preventing radiological release. The modeling and simulation framework integrating FLEX equipment with Force on Force models enables the nuclear power plants to credit FLEX portable equipment in the plant security posture, resulting in an efficient and optimized physical security.

97 MATHEMATICS AND COMPUTING↗

RESCue Model (RESCue Experiment and Model) [SWR-24-84]

The Renewable Energy and Storage Cybersecurity Research (RESCue) project is a collaborative effort aimed at securing the rapidly growing deployment of transmission-connected hybrid renewable energy systems, consisting of a combination of wind, solar, and/or energy storage equipment, against escalating cyber threats. This project brings together major original equipment manufacturers (OEMs) of wind, solar, and energy storage, along with major asset owners and DOE National Laboratories, to collectively identify cyber threats, assess risks, and develop robust cybersecurity strategies and solutions. The development of hybrid reference architectures has provided comprehensive blueprints for the secure design and integration of hybrid renewable energy systems, accounting for their unique characteristics and interdependencies. Additionally, NREL has created a cyber-resilient design framework that integrates cybersecurity considerations from the start of the system lifecycle, ensuring security is "baked in" from the initial design phase. The research thrusts for the project included (i) development of hybrid reference architectures and (ii) a cyber-resilient design framework for hybrid energy systems. The reference architectures has provided comprehensive blueprints for the secure design and integration of hybrid renewable energy systems, accounting for their unique characteristics and interdependencies. Additionally, NREL has created a cyber-resilient design framework that integrates cybersecurity considerations from the start of the system lifecycle, ensuring security is "baked in" from the initial design phase. A demonstration experiment was developed for one of the architectures using NREL's Cyber Range resources. This experiment configuration, deployable using open-source tools, is provided here in this repository. Additional models were developed for the wind and solar architectures as well, however the configurations for only the Energy Storage scenario are provided here: https://www.nrel.gov/docs/fy24osti/89921.pdf

Hasandka, Adarsh↗

​​Integrity Enhancing Protocols (IEP) Evaluation Framework​

​Protocols play an essential role in Advance Reactor systems. A diverse set of protocols are available to these reactors. Advanced Reactors benefit from technologies that can minimize their resource utilization and costs. Evaluation frameworks are often used when assessing protocols and processes related to cryptographic security systems. The following report discusses the various characteristics associated with these protocol evaluation frameworks, and derives a novel evaluative framework.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FALCON: Framework for Anomaly Detection in Industrial Control Systems

Industrial Control Systems (ICS) are used to control physical processes in critical infrastructure. These systems are used in a wide variety of operations such as water treatment, power generation and distribution, and manufacturing. While the safety and security of these systems are of serious concern, recent reports have shown an increase in targeted attacks aimed at manipulating physical processes to cause catastrophic consequences. This trend emphasizes the need for algorithms and tools that provide resilient and smart attack detection mechanisms to protect ICS. In this paper, we propose an anomaly detection framework for ICS based on a deep neural network. The proposed methodology uses dilated convolution and long short-term memory (LSTM) layers to learn temporal as well as long term dependencies within sensor and actuator data in an ICS. The sensor/actuator data are passed through a unique feature engineering pipeline where wavelet transformation is applied to the sensor signals to extract features that are fed into the model. Additionally, this paper explores four variations of supervised deep learning models, as well as an unsupervised support vector machine (SVM) model for this problem. The proposed framework is validated on Secure Water Treatment testbed results. This framework detects more attacks in a shorter period of time than previously published methods.

97 - MATHEMATICS AND COMPUTING↗

Security Enhancement of Network Constraint Grid-Edge Energy Management System

Network constrained grid edge energy management system (EMS) provides economic solution for active and reactive power dispatch of distributed energy resources (DERs) at the grid edge level. Grid edge EMS ensures secure interconnection of a circuit segment to the distribution system by maintaining grid code requirements (e.g. IEEE 1547–2018). Grid edge EMS is dependent on communication to receive load measurement, which brings a risk of unobservable false data injection attacks (FDIAs). To mitigate the risk, this paper proposes a framework to enhance resilient operation of grid edge EMS by detecting the unobservable FDIAs on loads and replacing them with forecasted values. In this work, a two-step detection algorithm is proposed. In first step, conventional residual based algorithm is deployed. Autoencoder (AE) based data driven mechanism is included in second step to detect the presence of unobservable FDIAs. After ensuring the presence of FDIA, its specific location is detected by checking the maximum residue values till the predefined threshold value is reached. Detected false data injected loads are then replaced with forecasted load values following long-short term memory (LSTM) based forecast to ensure resilient performance of grid edge EMS in the presence of attacks. This proposed security enhancement framework for grid edge EMS is evaluated in IEEE 13 bus system with three integrated DERs. Numerical simulation shows the validation of the proposed framework by reducing voltage violation in real operation of grid edge EMS.

cyber attack detection↗

A Hierarchical Security Architecture for Cyber-Physical Systems

Security of control systems is becoming a pivotal concern in critical national infrastructures such as the power grid and nuclear plants. In this paper, we adopt a hierarchical viewpoint to these security issues, addressing security concerns at each level and emphasizing a holistic cross-layer philosophy for developing security solutions. We propose a bottom-up framework that establishes a model from the physical and control levels to the supervisory level, incorporating concerns from network and communication levels. We show that the game-theoretical approach can yield cross-layer security strategy solutions to the cyber-physical systems.

47 OTHER INSTRUMENTATION↗

A preliminary sub-basin scale evaluation framework of site suitability for onshore aquifer-based CO2 storage in China

Development of a reliable, broadly applicable framework for the identification and suitability evaluation of potential CO2 storage sites is essential before large scale deployment of carbon dioxide capture and geological storage (CCS) can commence. In this study, a sub-basin scale evaluation framework was developed to assess the suitability of potential onshore deep saline aquifers for CO2 storage in China. The methodology, developed in consultation with experts from the academia and the petroleum industry in China, is based on a multi-criteria analysis (MCA) framework that considers four objectives: (1) storage optimization, in terms of storage capacity and injectivity; (2) risk minimization and storage security; (3) environmental restrictions regarding surface and subsurface use; and (4) economic considerations. The framework is designed to provide insights into both the suitability of potential aquifer storage sites as well as the priority for early deployment of CCS with existing CO2 sources. Preliminary application of the framework, conducted using GIS-based evaluation tools revealed that 18% of onshore aquifer sites with a combined CO2 storage capacity of 746 gigatons are considered to exhibit very high suitability, and 11% of onshore aquifer sites with a total capacity of 290 gigatons exhibit very high priority opportunities for implementation. These onshore aquifer sites may provide promising opportunities for early large-scale CCS deployment and contribute to CO2 mitigation in China for many decades.

CO2 storage↗

IoT Devices and Applications for Wire-Based Hybrid Manufacturing Machine Tools

Hybrid manufacturing machine tools have the potential to be a disruptive technology as they can leverage the benefits of both additive and subtractive manufacturing by incorporating both processes on the same machine while limiting the downsides of the individual processes. Since these machines use two very disparate manufacturing processes and hybrid manufacturing is an emerging technology, it will be useful to monitor data coming from the machine and apply it to improve the manufacturing process, the operation of the machine, and to integrate the machine into the larger digital framework of Industrial Internet of Things (IoT). The present work discusses IoT devices that would be beneficial to add to a hybrid machine tool as well as applications for those devices. The proposed methods discussed in this work have not been experimentally implemented on a hybrid machine tool and so there are no performance data available yet. The hybrid machine tool used as a basis to generate these IoT applications is the Mazak VC-500A/5x AM Hot Wire Deposition, which is a 5-axis machine tool incorporated with a wire feedstock 4kW laser deposition system. Methodologies and applications will be outlined for machine health and process monitoring. Other areas covered include process benchmarking, secure networking options for the proposed IoT framework, and hybrid process improvement. Limitations of these methods and future work for new sensor devices and application areas is also discussed.

Thien, Austen↗

Consequence Based Framework for Deployment of Cloud Solutions in the Digital Energy Transition

This study proposes a framework for evaluating cloud computing deployment in the electric sector, focusing on the digital transition of energy systems. It assesses the implications of cloud technology adoption, particularly in terms of security, operational resilience, and efficiency. The paper introduces a framework for consequence-driven applied risk analysis, enabling utilities to prioritize and mitigate potential threats effectively, and responsibly deploy cloud applications. It also discusses the shared responsibility model in cloud computing, highlighting the need for collaborative security efforts. The research aims to provide utilities with a strategic assessment tool for cloud adoption, emphasizing the importance of security culture in enhancing cloud computing's role in critical infrastructure.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

U.S. Department of Energy Report on the First Quadrennial Technology Review (QTR)

Access to clean, affordable, secure, and reliable energy has been a cornerstone of American’s economic growth. Yet, today the Nation’s systems that produce, store, transmit, and use energy are falling short of U.S needs. The Department of Energy’s (DOE) first Quadrennial Technology Review (QTR), launched at the recommendation of the President’s Council of Advisors on Science and Technology (PCAST), addresses these facts. The report details today’s energy landscape and the associated energy security, economic and environmental challenges; provides a framework for presenting six strategies to address those challenges encompassing vehicle efficiency, deployment of alternative hydrocarbon fuels, increased building and industrial efficiency, modernization of the grid, and deployment of clean electricity; addresses priorities among activities in DOE’s energy-technology programs; and explains the roles that DOE, the broader government, the private sector, the national laboratories, and academia play in energy transformation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of Defensive Cybersecurity Architectures for High Temperature, Gas-Cooled Reactors

This report presents the design of defensive cybersecurity architectures (DCSAs) for High Temperature, Gas-Cooled Reactors (HTGRs). A DCSA is a cybersecurity design feature that places systems into security zones in a graded approach according to the importance of the functions performed by the systems. DCSA design efforts for advanced reactors may commence as early as the system-level design phase. This design approach is consistent with the draft regulatory guide for advanced reactor cybersecurity programs (DG-5075) and enables advanced reactor designers to consider the effects of security-by-design (SeBD) features on their DCSAs. Integration of DCSA design and other cybersecurity activities with the traditional design process as part of a SeBD framework may enable advanced reactor designers to improve the security posture of their plants while reducing implementation and operating costs. This report provides a DCSA template for an exemplar HTGR and describes a DCSA design process using event tree analysis so that the template may be optimized for a given HTGR design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of Defensive Cybersecurity Architectures for Sodium-Cooled Fast Reactors

This report presents the design of defensive cybersecurity architectures (DCSAs) for Sodium-Cooled Fast Reactors (SFRs). A DCSA is a cybersecurity design feature that places systems into security zones in a graded approach according to the importance of the functions performed by the systems. DCSA design efforts for advanced reactors may commence as early as the system-level design phase. This design approach is consistent with the draft regulatory guide for advanced reactor cybersecurity programs (DG-5075) and enables advanced reactor designers to consider the effects of security-by design (SeBD) features on their DCSAs. Integration of DCSA design and other cybersecurity activities with the traditional design process as part of a SeBD framework may enable advanced reactor designers to improve the security posture of their plants while reducing implementation and operating costs. This report provides a DCSA template for an exemplar SFR and how the template may be optimized for a given SFR design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ARC-100 Reactor Security-by-Design Summary

This report applies the security-by-design methodology developed in a previous National Nuclear Security Administration–sponsored work to the Advanced Reactor Concepts 100 (ARC-100) sodium-cooled fast reactor (SFR) design. The report contains no proprietary information specific to the ARC 100 reactor. The insights developed in this report are high-level, and generally applicable to other sodium fast reactor designs. The information presented here is the result of a qualitative safety-based analysis and would not inform any potential adversary beyond what would be found in a docketed safety analysis report. The scope of this present report covers ARC-100’s reactor core, used fuel storage, and used fuel assembly wash station. These systems are also compared to a generic SFR design assumed in the previous study. The security assessment results show changes in structures, systems, and components (SSCs) safety importance relative to the generic SFR SSCs. However, the consequence assessment results are the similar to a previously assessed generic SFR. Several SSCs have higher importance rankings than others, and it is recommended that protection efforts are prioritized for these SSCs. This work will continue in the Fiscal Year 2025 for the remaining ARC-100 systems, including cesium trap, sodium cold trap, noble gas decay tanks (dewar bottles), and used fuel dry storage facility, to provide safety-and-security-by-design insights and recommendations on non-core systems. Results from this work will furnish a technical justification for the feasibility of these solutions for the ARC reactor's design and, where applicable, identify any regulatory benefits conferred by the proactive design aspect within a risk management framework. This initiative will contribute to a more secure design of the ARC reactor and support its licensing process.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

How to implement security controls for an information security program at CBRN facilities

This document was prepared by PNNL within the framework of Project 19 of the European Union Chemical Biological Radiological and Nuclear Risk Mitigation Centres of Excellence Initiative entitled, ''Development of procedures and guidelines to create and improve secure information management systems and data exchange mechanisms for CBRN materials under regulatory control.'' It provides management and workers at CBRN facilities, parent organization managers responsible for those facilities, and regulatory agencies (governmental and nongovernmental) with guidance on the best practices for protecting information security. The security mitigation approaches presented in this document were chosen because they present generally accepted guidance in an easy-to-understand manner, making it easier for facility personnel to grasp key concepts and envision how security controls could be implemented by the facility. This guidance is presented from a risk management perspective.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Updating the U.S. Life Cycle GHG Petroleum Baseline to 2014 with Projections to 2040 Using Open-Source Engineering-Based Models

Here, the National Energy Technology Laboratory produced a well-to-wheels (WTW) life cycle greenhouse gas analysis of petroleum-based fuels consumed in the U.S. in 2005, known as the NETL 2005 Petroleum Baseline. This study uses a set of engineering-based, open-source models combined with publicly available data to calculate baseline results for 2014. An increase between the 2005 baseline and the 2014 results presented here (e.g., 92.4 vs 96.2 g CO 2 e/MJ gasoline, + 4.1%) are due to changes both in modeling platform and in the U.S. petroleum sector. An updated result for 2005 was calculated to minimize the effect of the change in modeling platform, and emissions for gasoline in 2014 were about 2% lower than in 2005 (98.1 vs 96.2 g CO 2 e/MJ gasoline). The same methods were utilized to forecast emissions from fuels out to 2040, indicating maximum changes from the 2014 gasoline result between +2.1% and –1.4%. The changing baseline values lead to potential compliance challenges with frameworks such as the Energy Independence and Security Act (EISA) Section 526, which states that Federal agencies should not purchase alternative fuels unless their life cycle GHG emissions are less than those of conventionally produced, petroleum-derived fuels.

54 ENVIRONMENTAL SCIENCES↗

Kalaeloa Energy System Redevelopment Options Including Advanced Microgrids.

In June 2016, the Department of Energy's (DOE's) Office of Energy Efficiency and Renewable Energy (EERE) in collaboration with the Renewable Energy Branch for the Hawaii State Energy Office (HSEO), the Hawaii Community Development Authority (HCDA), the United States Navy (Navy), and Sandia National Laboratories (Sandia) established a project to 1) assess the current functionality of the energy infrastructure at the Kalaeloa Community Development District, and 2) evaluate options to use both existing and new distributed and renewable energy generation and storage resources within advanced microgrid frameworks to cost-effectively enhance energy security and reliability for critical stakeholder needs during both short-term and extended electric power outages. This report discusses the results of a stakeholder workshop and associated site visits conducted by Sandia in October 2016 to identify major Kalaeloa stakeholder and tenant energy issues, concerns, and priorities. The report also documents information on the performance and cost benefits of a range of possible energy system improvement options including traditional electric grid upgrade approaches, advanced microgrid upgrades, and combined grid/microgrid improvements. The costs and benefits of the different improvement options are presented, comparing options to see how well they address the energy system reliability, sustainability, and resiliency priorities identified by the Kalaeloa stakeholders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

System Theoretic Frameworks for Mitigating Risk Complexity in the Nuclear Fuel Cycle

In response to the expansion of nuclear fuel cycle (NFC) activities -- and the associated suite of risks -- around the world, this project evaluated systems-based solutions for managing such risk complexity in multimodal and multi-jurisdictional international spent nuclear fuel (SNF) transportation. By better understanding systemic risks in SNF transportation, developing SNF transportation risk assessment frameworks, and evaluating these systems-based risk assessment frameworks, this research illustrated interdependency between safety, security, and safeguards risks is inherent in NFC activities and can go unidentified when each "S" is independently evaluated. Two novel system-theoretic analysis techniques -- dynamic probabilistic risk assessment (DPRA) and system-theoretic process analysis (STPA) -- provide integrated "3S" analysis to address these interdependencies and the research results suggest a need -- and provide a way -- to reprioritize United States engagement efforts to reduce global nuclear risks. Lastly, this research identifies areas where Sandia National Laboratories can spearhead technical advances to reduce global nuclear dangers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗