Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

AOI [3] High-Temperature Nano-Derived Micro-H 2 and - H 2 S Sensors

The emissions from coal-fired power plants remain a significant concern for air quality. This environmental challenge must be overcome by controlling the emission of sulfur dioxide (SO 2 ) and hydrogen sulfide (H 2 S) throughout the entire coal combustion process. One of the processes which could specifically benefit from robust, low cost, and high temperature compatible gas sensors is the coal gasification process which converts coal and/or biomass into syngas. Hydrogen (H 2 ), carbon monoxide (CO) and sulfur compounds make up 33%, 43% and 2% of syngas, respectively. Therefore, development of a high temperature (>500°C) chemical sensor for in-situ monitoring of H 2 , H 2 S and SO2 2 levels during coal gasification is strongly desired. The selective detection of SO 2 /H 2 S in the presence of H 2 , is a formidable task for a sensor designer. In order to ensure effective operation of these chemical sensors, the sensor system must inexpensively function within harsh temperature and chemical environment. Currently available sensing approaches, which are based on gas chromatography, electrochemistry, and IR-spectroscopy, do not satisfy the required cost and performance targets. This work focused on the development microsensors that can be applied to this application. In order to develop the high- temperature compatible microsensor, this work addressed various issues related to sensor stability, selectivity, and miniaturization. In the research project entitled “High-Temperature Nano-Derived Micro-H 2 and -H 2 S Sensors”, the team worked to develop micro-scale, chemical sensors and sensor arrays composed of nano-derived, metal-oxide composite materials to detect gases like H 2 , SO 2 , and H 2 S within high-temperature environments (>500°C). The research was completed in collaboration with NexTech Materials, Ltd. (Lewis Center, Ohio). NexTech assisted in the testing of the sensors in syngas with contaminate levels of H 2 S. The idea of including nanomaterials as the sensing material within resistive-type chemical sensor platforms was to increase the sensitivity (as shown for room temperature applications). Unfortunately, nanomaterials are not stable at high temperatures due to sintering and coarsening processes that are driven by their high surface to volume ratio. Therefore, new hydrogen and sulfur selective nanomaterial systems with high selectivity and stability properties in the proposed harsh environment were investigated. Different nano-morphologies of zirconate, molybdate, and tungstate compounds were investigated. The fabrication of the microsensors consisted of the deposition of the selective nanomaterial systems over metal based interconnects on an inert substrate. This work utilized the chemi-resistive (resistive- type) microsensor architecture where the chemically and structurally stable, high temperature compatible electrodes were sputtered onto a ceramic substrate. The nanomaterial sensing systems were deposited over the electrodes using a lost mold method patterned by conventional optical lithography. The microsensor configuration with optimized nanomaterial system was tested and compared to a millimeter-size sensor e outcomes of this research will contribute to the economical application of sensor arrays for simultaneous sensing of H 2 , H 2 S, and SO 2 .

47 OTHER INSTRUMENTATION↗

Array Of Sensors Measures Broadband Radiation

Multiple broadband radiation sensors aimed at various portions of total field of view. All sensors mounted in supporting frame, serving as common heat sink and temperature reference. Each sensor includes heater winding and differential-temperature-sensing bridge circuit. Power in heater winding adjusted repeatedly in effort to balance bridge circuit. Intended to be used aboard satellite in orbit around Earth to measure total radiation emitted, at various viewing angles, by mosaic of "footprint" areas (each defined by its viewing angle) on surface of Earth. Modified versions of array useful for angle-resolved measurements of broadband radiation in laboratory and field settings on Earth.

Hoffman, James W.↗

Improved Performance of Zinc Oxide Thin Film Transistor Pressure Sensors and a Demonstration of a Commercial Chip Compatibility with the New Force Sensing Technology

Abstract A zinc oxide thin film transistor is developed and optimized that simultaneously functions as a transistor and a force sensor, thus allowing for scalable integration of sensors into arrays without the need for additional addressing elements. Through systematic material deposition, microscopy, and piezoelectric characterization, it is determined that an O 2 rich deposition condition improves the transistor performance and pressure sensing characteristics. With these optimizations, a sensitivity of 4 nA kPa −1 and a latency of below 1 ms are achieved, exceeding the criteria for successful commercialization of arrayed pressure sensors. The functionality of 16 × 16 pressure sensor arrays on thin bendable glass substrates for integrated low weight and flexible touchscreen displays is fabricated and demonstrated and read‐out electronics to interface with the arrays and to record their response in real‐time are developed. Finally, the application of these sensors for mobile displays via their operation with an existing commercial touch integrated circuit controller is demonstrated.

Vishniakou, Siarhei↗

Comparison of Measured Dark Current Distributions with Calculated Damage Energy Distributions in HgCdTe

This paper presents a combined Monte Carlo and analytic approach to the calculation of the pixel-to-pixel distribution of proton-induced damage in a HgCdTe sensor array and compares the results to measured dark current distributions after damage by 63 MeV protons. The moments of the Coulombic, nuclear elastic and nuclear inelastic damage distributions were extracted from Monte Carlo simulations and combined to form a damage distribution using the analytic techniques first described in [1]. The calculations show that the high energy recoils from the nuclear inelastic reactions (calculated using the Monte Carlo code MCNPX [2]) produce a pronounced skewing of the damage energy distribution. While the nuclear elastic component (also calculated using the MCNPX) contributes only a small fraction of the total nonionizing damage energy, its inclusion in the shape of the damage across the array is significant. The Coulombic contribution was calculated using MRED [3-5], a Geant4 [4,6] application. The comparison with the dark current distribution strongly suggests that mechanisms which are not linearly correlated with nonionizing damage produced according to collision kinematics are responsible for the observed dark current increases. This has important implications for the process of predicting the on-orbit dark current response of the HgCdTe sensor array.

Marshall, C. J.↗

Image-plane processing for improved computer vision

The proper combination of optical design with image plane processing, as in the mechanism of human vision, which allows to improve the performance of sensor array imaging systems for edge detection and location was examined. Two dimensional bandpass filtering during image formation, optimizes edge enhancement and minimizes data transmission. It permits control of the spatial imaging system response to tradeoff edge enhancement for sensitivity at low light levels. It is shown that most of the information, up to about 94%, is contained in the signal intensity transitions from which the location of edges is determined for raw primal sketches. Shading the lens transmittance to increase depth of field and using a hexagonal instead of square sensor array lattice to decrease sensitivity to edge orientation improves edge information about 10%.

Huck, F. O.↗

TRACER Lightning Mapping Array Field Campaign Report

Our observational contribution to the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Tracking Aerosol Convection Interactions Experiment (TRACER) was the deployment of additional Lightning Mapping Array sensors to provide enhanced capability to the Houston Lightning Mapping Array (HLMA) during the TRACER intensive operational period. To that end, the Texas Tech University personnel (Professor Bruning and Dr. Brunner, and graduate students Jessica Souza, David Singewald, Stephanie Weiss, and Matthew Miller) deployed two portable LMA antennae at locations G and B shown in the map below. The map also shows the predicted lightning flash detection efficiency in black contours, as well as color-shaded very-high-frequency (VHF) source detection efficiency, which roughly corresponds to the sensitivity to lightning channel detail.

Tracking Aerosol Convection Interactions Experimen↗

Comparison of Measured Leakage Current Distributions with Calculated Damage Energy Distributions in HgCdTe

This paper presents a combined Monte Carlo and analytic approach to the calculation of the pixel-to-pixel distribution of proton-induced damage in a HgCdTe sensor array and compares the results to measured dark current distributions after damage by 63 MeV protons. The moments of the Coulombic, nuclear elastic and nuclear inelastic damage distribution were extracted from Monte Carlo simulations and combined to form a damage distribution using the analytic techniques first described in [I]. The calculations show that the high energy recoils from the nuclear inelastic reactions (calculated using the Monte Car10 code MCNPX [2]) produce a pronounced skewing of the damage energy distribution. The nuclear elastic component (also calculated using the MCNPX) has a negligible effect on the shape of the damage distribution. The Coulombic contribution was calculated using MRED [3,4], a Geant4 [4,5] application. The comparison with the dark current distribution strongly suggests that mechanisms which are not linearly correlated with nonionizing damage produced according to collision kinematics are responsible for the observed dark current increases. This has important implications for the process of predicting the on-orbit dark current response of the HgCdTe sensor array.

Marshall, C. J.↗

Development of Autonomous Magnetometer Rotorcraft For Wide Area Assessment

Large areas across the United States and internationally are potentially contaminated with unexploded ordinance (UXO), with some ranges encompassing tens to hundreds of thousands of acres. Technologies are needed which will allow for cost effective wide area scanning with (1) near 100% coverage and (2) near 100% detection of subsurface ordnance or features indicative of subsurface ordnance. The current approach to wide area assessment is a multi-level one, in which medium - altitude fixed wing optical imaging is used for an initial site assessment. This assessment is followed with low altitude manned helicopter based magnetometry. Subsequent to this wide area assessment targeted surface investigations are performed using either towed geophysical sensor arrays or man portable sensors. In order to be an effective tool for small UXO detection, the sensing altitude for magnetic site investigations needs to be on the order of 1 to 3 meters. These altitude requirements mean that manned helicopter surveys will generally only be feasible in large, open and relatively flat terrains. While such surveys are effective in mapping large areas relatively fast there are substantial mobilization/demobilization, staffing and equipment costs associated with these surveys, resulting in costs of approximately $100-$150/acre. In addition, due to the low altitude there are substantial risks to pilots and equipment. Surface towed arrays provide highresolution maps but have other limitations, e.g. in their ability to navigate rough terrain effectively. Thus there is a need for other systems, which can be used for effective data collection. An Unmanned Aerial Vehicle (UAV) magnetometer platform is an obvious alternative. The motivation behind such a system is that it reduces risk to operators, is lower in initial and Operational and Maintenance (O&M) costs (and can thus potentially be applied to smaller sites) and has the potential of being more effective in terms of detection and possibly characterization (through the use of dynamic acquisition, i.e. survey mission in-flight reprioritization).

58 GEOSCIENCES↗

Development of autonomous magnetometer rotorcraft for wide area assessment

Large areas across the United States are potentially contaminated with UXO, with some ranges encompassing tens to hundreds of thousands of acres. Technologies are needed which will allow for cost effective wide area scanning with 1) near 100 % coverage and 2) near 100 % detection of subsurface ordnance or features indicative of subsurface ordnance. The current approach to wide area assessment is a multi-level one, in which medium - altitude fixed wing optical imaging is used for an initial site assessment. This assessment is followed with low altitude manned helicopter based magnetometry. Subsequent to this wide area assessment targeted surface investigations are performed using either towed geophysical sensor arrays or man portable sensors. In order to be an effective tool for small UXO detection, the sensing altitude for magnetic site investigations needs to be on the order of 1 – 3 meters. These altitude requirements mean that manned helicopter surveys will generally only be feasible in large, open and relatively flat terrains. While such surveys are effective in mapping large areas relatively fast there are substantial mobilization/demobilization, staffing and equipment costs associated with these surveys (resulting in costs of approximately $100-$150/acre). In addition, due to the low altitude there are substantial risks to pilots and equipment. Surface towed arrays provide high resolution maps but have other limitations, e.g. in their ability to navigate rough terrain effectively. There is thus a need for other systems which can be used for effective data collection. An UAV (Unmanned Aerial Vehicle) magnetometer platform is an obvious alternative. The motivation behind such a system is that it reduces risk to operators, is lower in initial and Operational and Maintenance (O&M) costs (and can thus potentially be applied to smaller sites) and has the potential of being more effective in terms of detection and possibly characterization (through the use of dynamic acquisition, i.e. survey mission inflight reprioritization). We describe and report on a one year effort with as primary goal to provide a recommendation to SERDP for a path forward in the implementation of one or more autonomous unmanned magnetometer rotorcraft platforms. This recommendation (which is provided in chapter 6) is based on the following three elements a) An assessment on the applicability of autonomous rotorcraft magnetometer systems to the current DoD site inventory, and an initial assessment of which type(s) of autonomous unmanned magnetometer rotorcraft platforms (in terms of performance characteristics such as payload, altitude, obstacle avoidance, production rate and flight time) would be most relevant to this inventory (chapter 3); b) An evaluation of the feasibility of assembling such platforms from commercial components (unmanned rotorcraft, control systems and sensors – both magnetometer sensors and supporting sensors). This evaluation included several highly successful field tests (chapter 4 and 5); c) A recommendation of the path forward, which includes a detailed outline of the efforts required in the design, assembly and testing of different modular platforms (chapter 6)

58 GEOSCIENCES↗

Characterization and Analysis of Networked Array of Sensors for Event Detection (CANARY-EDS)

CANARY -EDS provides probabilistic event detection based on analysis of time-series data from water quality or other sensors. CANARY also can compare patterns against a library of previously seen data to indicate that a certain pattern has reoccurred, suppressing what would otherwise be considered an event. CANARY can be configured to analyze previously recorded data from files or databases, or it can be configured to run in real-time mode directory from a database, or through the US EPA EDDIES software.

Source record↗

Micromachined Thermoelectric Sensors and Arrays and Process for Producing

Linear arrays with up to 63 micromachined thermopile infrared detectors on silicon substrates have been constructed and tested. Each detector consists of a suspended silicon nitride membrane with 11 thermocouples of sputtered Bi-Te and Bi-Sb-Te thermoelectric elements films. At room temperature and under vacuum these detectors exhibit response times of 99 ms, zero frequency D* values of 1.4 x 10(exp 9) cmHz(exp 1/2)/W and responsivity values of 1100 V/W when viewing a 1000 K blackbody source. The only measured source of noise above 20 mHz is Johnson noise from the detector resistance. These results represent the best performance reported to date for an array of thermopile detectors. The arrays are well suited for uncooled dispersive point spectrometers. In another embodiment, also with Bi-Te and Bi-Sb-Te thermoelectric materials on micromachined silicon nitride membranes, detector arrays have been produced with D* values as high as 2.2 x 10(exp 9) cm Hz(exp 1/2)/W for 83 ms response times.

Foote, Marc C.↗

Cyrano "Nose" The Smell of Success

Cyrano Sciences, Inc. has commercialized a simple, accurate, non- invasive tool that enables "machines to smell". The Cyranose 320 is used for quality control purposes in the food and chemical industries. Using a sensor array and onboard pattern recognition algorithms, the lightweight, portable device works by exposing an array of polymer composite sensors to the chemical components in a vapor. When the sensors come in contact with the vapor, the polymer expands like a sponge, changing the resistance of the composites. The change in resistance is measured, and from that measurement, the presence of a pre-trained substance is determined with a quick and accurate diagnosis. This real-time, portable device enables food companies to spot test raw materials for batch-to-batch consistency, spoilage, or contamination. The Cyranose 320 is also used by chemical and petrochemical companies for quick assessment of the chemical status associated with various industrial processes. Profiling a chemical environment in a hazardous materials situation allows emergency crews to accurately select fire retardants, containment strategies, and protective gear. Future applications for the Cyranose 320 are fast growing and other uses of this technology are on the horizon.

Source record↗

The JPL Electronic Nose: Monitoring Air in the US Lab on the International Space Station

An electronic nose with a sensor array of 32 conductometric sensors has been developed at the Jet Propulsion Laboratory (JPL) to monitor breathing air in spacecraft habitat. The Third Generation ENose is designed to operate in the environment of the US Lab on the International Space Station (ISS). It detects a selected group of analytes at target concentrations in the ppm regime at an environmental temperature range of 18 - 30 oC, relative humidity from 25 - 75% and pressure from 530 to 760 torr. The monitoring targets are anomalous events such as leaks and spills of solvents, coolants or other fluids. The JPL ENose operated as a technology demonstration for seven months in the U.S. Laboratory Destiny during 2008-2009. Analysis of ENose monitoring data shows that there was regular, periodic rise and fall of humidity and occasional releases of Freon 218 (perfluoropropane), formaldehyde, methanol and ethanol. There were also several events of unknown origin, half of them from the same source. Each event lasted from 20 to 100 minutes, consistent with the air replacement time in the US Lab.

chemical sensors↗

Characterization and Analysis of Networked Array of Sensors for Event Detection (CANARY-EDS)

CANARY -EDS provides probabilistic event detection based on analysis of time-series data from water quality or other sensors. CANARY also can compare patterns against a library of previously seen data to indicate that a certain pattern has reoccurred, suppressing what would otherwise be considered an event. CANARY can be configured to analyze previously recorded data from files or databases, or it can be configured to run in real-time mode directory from a database, or through the US EPA EDDIES software.

Source record↗

Gas sensor and method of optimizing an array of gas sensors

A gas sensor (100,200) includes at least one sensor device including a surface acoustic wave (SAW) device (110) or a quartz crystal microbalance (QCM) device (210), and a layer of metal organic framework (MOF) material (120,220) disposed on each of the at least one sensor device. The at least one sensor device is structured to sense a change in mass of the MOF material.

Wilmer, Christopher E.↗

Unobtrusive Sensor-Based Occupancy Facing Direction Detection and Tracking Using Advanced Machine Learning Algorithms

Facing direction detection plays a critical role in human-computer interaction and has a wide application in surveillance systems, driving awareness recognition, smart home appliances, computer games, and so on. Current detection methods are mainly focused on extracting specific patterns from user's optical images, which raises concerns on privacy invasion and these detection techniques do not usually work in a dark environment. To address these concerns, here this paper proposes an activity recognition system guided by an unobtrusive sensor (ARGUS). By using a low pixel infrared thermopile array sensor, ARGUS is capable of identifying five facing directions (left 45°/90°, right 45°/90°, and front) through the support vector machine classifier. Also two feature extraction methods are compared. One is manually-defined and the other is based on a pre-trained convolutional neural network (CNN) model. The facing direction detection accuracy resulting from manually-defined features reaches 85.3%, 90.6%, and 85.2% at detection distance of 0.6, 1.2, and 1.8 m, respectively. The level of accuracy resulted from using pre-trained CNN features demonstrates a much more reliable performance (89.1%, 95.3%, and 95.1% at distance of 0.6, 1.2, and 1.8 m, respectively). In addition, ARGUS has been successfully applied for occupancy tracking with a root mean square error of 0.19 m.

42 ENGINEERING↗