At least 253 records · Page 14

Inertial Transfer Concept for Autonomous In-Space Assembly

Rocket payload and fairing size have placed strict mass and volume limitations on single launch in-space structures. These limitations are what motivates In-Space Assembly (ISA) and where Inertial Transfer has potential to improve or augment ISA capabilities by utilizing a multiagent autonomous system to transport untethered payloads. The Inertial Transfer concept is presented including autonomy capabilities, potential risks, and three system configurations. These configurations are based on the autonomous system’s available sensor coverage that tracks the payload’s state. Participating agents have well-defined roles, expectations, and assumptions in their physical organization and coordination of actions depending the mode of operation. The sensor information available to participating agents is considered as it affects the uncertainty in the estimated state and the actions required to capture the payload.

Multi-Agent↗

Implementing a Terrestrial Timing Solution: Best Practices

This document is an overview and guide on the concept of precision time and how an alternative terrestrial timing solution to the Global Positioning System (GPS) can be implemented. What follows is a set of recommendations and best practices, derived from research at Oak Ridge National Laboratory (ORNL), across industry, and within the U.S. government, to implement a system of precision timing synchronization to support resilient operations for the U.S. grid. Precision time is a fundamental necessity for operating the grid today, and it becomes even more important as the grid modernizes with clean energy sources, microgrids, and precision sensors placed throughout the grid system to ensure failureresistant operations. The Global Navigation Satellite System (GNSS), which includes (GPS), is currently the primary provider of precision timing today. A terrestrial-based system for time delivery and synchronization to augment GPS is outlined below and it would provide secure time, synchronized with Coordinated Universal Time (UTC), in the event of outages or other interruptions associated with time delivery.

47 OTHER INSTRUMENTATION↗

Spatially Adaptive Tunable Lighting Control System with Expanded Wellness and Energy Saving Benefits

Lighting design is becoming increasingly complex, including active dimming for energy savings and spectral tuning for human wellbeing. Modern commercial lighting control systems are already difficult to use, and maintain, and even with so-called Smart Lighting, optimizing light settings is rapidly exceeding the capabilities of direct human control, limiting the adoption of lighting control systems. The growing importance of Occupancy Centric Controls (OCC) for advanced building management systems can be applied to the development of autonomous lighting system controls needed to drive the adoption of advanced lighting controls for improved adaptive “sculpted illumination” for both greater energy savings and broader human wellbeing perspectives. This project, led by Rensselaer Polytechnic Institute, entitled “Spatially adaptive tunable lighting control system with expanded wellness and energy saving benefits” will develop and test an entirely new platform for automated optimized lighting design and control that requires little or no human engagement, yet contours lighting profiles automatically to minimize lighting energy use. We call this approach to lighting control “dynamic light sculpting” since the right amount of illumination is automatically delivered to occupants in real time. Since the system uses new, privacy-preserving occupant position and pose detection technologies developed by Rensselaer for broad OCC building applications, the control system will analyze how to deliver the right amount of the right type of illumination only where and when it is needed based these OCC platforms. To create these powerful autonomous lighting control platforms, the project will integrate evolving augmented reality (AR) and virtual reality (VR) tools with sophisticated lighting and interior design toolkits to create interactive lighting design and control simulators. Using the quickly growing paradigm of digital twins, these tools will integrate light fixture properties, occupancy sensor data, interior design data, and lighting specifications to accurately visualize how various design concepts interact with simulated yet realistic human activities that occur in commercial office buildings of various types. These advanced digital twin design and simulation tools will be combined with a new class of digitally-programmable LED lighting fixtures that can dynamically change the spectral content and direction of light emission. When fully integrated, the new autonomous lighting control system will take all of the guesswork out of optimizing light quality while minimizing energy consumption. Digital twin tools will simplify the design, installation, commissioning, operation, and maintenance of future energy-efficient lighting systems. It should be possible to reduce lighting energy costs from 40% to 70% with OCC based dynamic light sculpting systems. The work will be led by the Center for Lighting Enabled Systems and Applications (LESA) and the Center for Architectural Science and Ecology (CASE), both at Renssealer Polytechnic Institute; Lumileds, a global leader in the development of advanced LED systems; and HKS, a leading global architecture design firm. This interdisciplinary project team’s experience includes all of the design simulation tools, VR/AR digital twin visualization technology, advanced occupancy sensing technology, and complex control system design capabilities that will revolutionize lighting design and control technology to autonomously deliver high-quality lighting that improves human health and wellbeing while simultaneously maximizing lighting energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spectral Irradiance Calibration in the Infrared: 1.2-35 micrometer Spectra of Six Standard Stars - Part 4

Five new absolutely calibrated continuous stellar spectra from 1.2 to 35 microns are presented. The spectra were constructed as far as possible from actual observed spectral fragments taken from the ground, the Kuiper Airborne Observatory (KAO), and the IRAS Low Resolution Spectrometer (LRS). These stars (beta Peg, alpha Boo, beta And, beta Gem, and alpha Hya) augment the author's already created complete absolutely calibrated spectrum for alpha Tau. All these spectra have a common calibration pedigree. The wavelength coverage is ideal for calibration of many existing and proposed ground-based, airborne, and satellite sensors.

Cohen, Martin↗

SMAP Validation Experiment 2019-2020 (SMAPVEX19/20): Detection of Soil Moisture Under Forest Canopy

The retrieval of soil moisture under forest canopy has long been an important goal for low frequency remote sensing. The NASA mission started a dedicated field experiment in May 2019 by deploying two temporary soil moisture networks in northeast US that cover two separate SMAP pixels with variable degree of forest cover. The measurements will run through 2020 and they will be augmented with two intensive observation periods (IOP). The first IOP will be conducted in June-July 2020 and the other one in October 2020. The IOPs will see deployment of the airborne PALS (Passive Active L-band sensor) instrument, which is similar to the SMAP instrument, and intensive manual measurements of soil moisture and vegetation. The measurements also include tower-based radiometer observations with ground truth measurements within the instrument footprint. The early results have shown that the SMAP measurement signal at L-band is sensitive to soil moisture changes observed on the ground.

Andreas Colliander↗

Development and flight evaluation of an augmented stability active controls concept: Executive summary

A pitch active control system (PACS) was developed and flight tested on a wide body jet transport (L-1011) with a flying horizontal stabilizer. Two dual channel digital computers and the associated software provide command signals to a dual channel series servo which controls the stabilizer power actuators. Input sensor signals to the computer are pitch rate, column trim position, and dynamic pressure. Control laws are given for the PACS and the system architecture is defined. Discussions are given regarding piloted flight simulation and vehicle system simulation and vehicle system simulation tests that are performed to verify control laws and system operation prior to installation on the aircraft. Modifications to the basic aircraft included installation of the PACS, addition of a c.g. management system to provide a c.g. range from 25 to 39% mac, and downrigging of the geared elevator to provide the required nose down control authority for aft c.g. flight test conditions. Three pilots used the Cooper-Harper Rating Scale to judge flying qualities of the aircraft with PACS on and off. The handling qualities with the c.g. at 39% mac (41% stability margin) and PACS operating were judged to be as good as the handling qualities with the c.g. at 25% mac (+15% stability margin) and PACS off.

Guinn, W. A.↗

Conformable amplified lead zirconate titanate sensors with enhanced piezoelectric response for cutaneous pressure monitoring

The ability to measure subtle changes in arterial pressure using devices mounted on the skin can be valuable for monitoring vital signs in emergency care, detecting the early onset of cardiovascular disease and continuously assessing health status. Conventional technologies are well suited for use in traditional clinical settings, but cannot be easily adapted for sustained use during daily activities. Here we introduce a conformal device that avoids these limitations. Ultrathin inorganic piezoelectric and semiconductor materials on elastomer substrates enable amplified, low hysteresis measurements of pressure on the skin, with high levels of sensitivity (~0.005 Pa) and fast response times (~0.1 ms). Experimental and theoretical studies reveal enhanced piezoelectric responses in lead zirconate titanate that follow from integration on soft supports as well as engineering behaviours of the associated devices. As a result, calibrated measurements of pressure variations of blood flow in near-surface arteries demonstrate capabilities for measuring radial artery augmentation index and pulse pressure velocity.

47 OTHER INSTRUMENTATION↗

Bridge feedback for active damping augmentation

A method is described for broadband damping augmentation of a structural system in which the active members (with feedback control) were developed such that their mechanical input impedance can be electrically adjusted to maximize the energy dissipation rate in the structural system. The active member consists of sensors, an actuator, and a control scheme. A mechanical/electrical analogy is described to model the passive structures and the active members in terms of their impedance representation. As a result, the problem of maximizing dissipative power is analogous to the problem of impedance matching in the electrical network. Closed-loop performance was demonstrated for single- and multiple-active-member controlled truss structure.

Chen, G.-S.↗

Development of the NASA MCAT Auxiliary Telescope for Orbital Debris Research

The National Aeronautical and Space Administration (NASA) has recently deployed the Meter Class Autonomous Telescope (MCAT) to Ascension Island. MCAT will provide NASA with a dedicated optical sensor for observations of orbital debris with the goal of statistically sampling the orbital and photometric characteristics of the population from low Earth to Geosynchronous orbits. Additionally, a small auxiliary telescope, co-located with MCAT, is being deployed to augment its observations by providing near-simultaneous photometry and astrometry, as well as offloading low priority targets from MCAT's observing queue. It will also be available to provide observational measurements to the Space Surveillance Network for the United States Air Force.

Frith, James↗

Exosuit Prototypic Knee: EPK

Resistive/aerobic exercises are invaluable countermeasures to musculoskeletal/sensorimotor/cognitive deconditioning resulting from spaceflight (i.e., microgravity). In preparation for human exploration to the moon and beyond, exercise countermeasures face new mass/volume constraints, rendering current on-orbit systems infeasible. Further, effective exercise systems are critical for maintaining crew performance/health levels necessary for Lunar extravehicular activities (EVAs) and transit. Exosuits are the pinnacle of wearable and adaptable technology set to provide a lightweight, compact, innovative solution to exploration-constrained exercise. However, reliable wearable kinematic sensors integrated with softgoods have not been demonstrated in (operational) spaceflight applications. To address this gap, the project team developed a prototype exosuit knee-joint, replete with relevant sensors for determination of joint angles, and corresponding laboratory testing bench to validate the exosuit sensing performance. This technology advancement is a pre-cursor to a more expansive multi-purpose exosuit concept that provides metrology, exercise, rehabilitation, and/or augmentation.

Fiber optics↗

Sensor discriminators and methods for detecting electrical property changes in a metal organic framework

A sensor discriminator for detecting a gaseous substance includes a power source, a discrimination module, a sensor simulator that simulates a metal organic framework under at least one simulation condition, a simulation circuitry electrically coupling the sensor simulator to the power source and the discrimination module, and a discriminator circuitry that electrically couples the power source and the discrimination module to a gas capture probe. The discrimination module compares a discrimination pulse and a simulation pulse from the power source after the discrimination pulse passes through a metal organic framework of the gas capture sensor and the simulation pulse passes through a simulation component of the sensor simulator. The discrimination module causes a discriminator output that includes the comparison of the discrimination pulse to the simulation pulse. An electrical property of the discrimination pulse depends on an electrical parameter of the metal organic framework that is augmented by the gaseous substance.

Christensen, Daniel A.↗

A cost-effective intelligent robotic system with dual-arm dexterous coordination and real-time vision

Dexterous coordination of manipulators based on the use of redundant degrees of freedom, multiple sensors, and built-in robot intelligence represents a critical breakthrough in development of advanced manufacturing technology. A cost-effective approach for achieving this new generation of robotics has been made possible by the unprecedented growth of the latest microcomputer and network systems. The resulting flexible automation offers the opportunity to improve the product quality, increase the reliability of the manufacturing process, and augment the production procedures for optimizing the utilization of the robotic system. Moreover, the Advanced Robotic System (ARS) is modular in design and can be upgraded by closely following technological advancements as they occur in various fields. This approach to manufacturing automation enhances the financial justification and ensures the long-term profitability and most efficient implementation of robotic technology. The new system also addresses a broad spectrum of manufacturing demand and has the potential to address both complex jobs as well as highly labor-intensive tasks. The ARS prototype employs the decomposed optimization technique in spatial planning. This technique is implemented to the framework of the sensor-actuator network to establish the general-purpose geometric reasoning system. The development computer system is a multiple microcomputer network system, which provides the architecture for executing the modular network computing algorithms. The knowledge-based approach used in both the robot vision subsystem and the manipulation control subsystems results in the real-time image processing vision-based capability. The vision-based task environment analysis capability and the responsive motion capability are under the command of the local intelligence centers. An array of ultrasonic, proximity, and optoelectronic sensors is used for path planning. The ARS currently has 18 degrees of freedom made up by two articulated arms, one movable robot head, and two charged coupled device (CCD) cameras for producing the stereoscopic views, and articulated cylindrical-type lower body, and an optional mobile base. A functional prototype is demonstrated.

Marzwell, Neville I.↗

Development and flight evaluation of an augmented stability active controls concept with a small horizontal tail

A limited authority pitch active control system (PACS) was developed for a wide body jet transport (L-1011) with a flying horizontal stabilizer. Two dual channel digital computers and the associated software provide command signals to a dual channel series servo which controls the stabilizer power actuators. Input sensor signals to the computer are pitch rate, column-trim position, and dynamic pressure. Control laws are given for the PACS and the system architecture is defined. The piloted flight simulation and vehicle system simulation tests performed to verify control laws and system operation prior to installation on the aircraft are discussed. Modifications to the basic aircraft are described. Flying qualities of the aircraft with the PACS on and off were evaluated. Handling qualities for cruise and high speed flight conditions with the c.g. at 39% mac ( + 1% stability margin) and PACS operating were judged to be as good as the handling qualities with the c.g. at 25% (+15% stability margin) and PACS off.

Rising, J. J.↗

Spectral Irradiance Calibration in the Infrared: 3-35 microns Spectra of Three Southern Standard Stars - Part 6

We present three new absolutely calibrated continuous stellar spectra from 3 to 35 microns, constructed as far as possible from actual observed spectral fragments taken from the Kuiper Airborne Observatory (KAO), and the IRAS Low Resolution Spectrometer (LRS). These stars- alpha(sup 1) Cen, alpha TrA, and epsilon Car-augment our previous archive of complete absolutely calibrated spectra for northern K and M giants. All these spectra have a common calibration pedigree. The wavelength coverage is ideal for calibration of many existing and proposed ground-based, airborne, and satellite sensors. KAO and IRAS data in the 15-30 micron range suggest that the spectra of cool giants are close to Rayleigh-Jeans slopes. Our observations of alpha(sup 1) Cen, absolutely calibrated via our adopted Sirius model, indicate an angular diameter in very good agreement with values in the literature, demonstrating 'closure' of the set of spectra within our absolute framework. We compare our observed alpha(sup 1) Cen spectrum with a published grid of theoretical models from Kurucz, and adopt a plausible theoretical shape, that fits our spectrum, as a secondary reference spectrum in the southern sky.

Cohen, Martin↗

Controllable oxygen vacancy defect engineering of BiVO 4 porous structures for room temperature NH 3 detection

Controlling structural features of sensing material while judiciously introducing vacancy defect states for revamping the electronic properties of the sample to obtain its superior gas sensing performance, is quite rare. Herein, we report for the first time, the room temperature (RT) ammonia (NH 3 ) detection of peanut-like porous bismuth vanadate (BiVO 4 ) with a stable monoclinic phase. The developed BiVO 4 possess abundant oxygen vacancies and porosity by virtue of calcinations (400–800 ℃). BiVO 4 calcined at 400 ℃ exhibits high selectivity towards NH 3 with a maximum response of 1421 @ 270 ppm at RT, which is 2.5 fold enhanced compared to without calcined BiVO 4 (response of 547 @ 270 ppm NH 3 ). The oxygen defective BiVO 4 appeared highly durable and stable even under high humid conditions (∼60 %). Besides, the porosity of BiVO 4 not only enhances the specific surface area (19.8 m 2 /g) but also results in fast diffusion of NH 3 molecules, leading to a reduction in the decay time (34 s for 90 ppm NH 3 ). The density functional theory (DFT) uncovers that the oxygen vacancy formation in BiVO 4 augments the NH 3 sensing capabilities by enhancing the adsorption energy of NH 3 . This work provides insight into the sensing mechanism of increased response caused by defect engineering and porosity, which will be favourable for fabricating high-performance NH 3 sensors at RT.

DFT analysis↗

Experimental characterization of the effects of pneumatic tubing on unsteady pressure measurements

Advances in aircraft control system designs have, with increasing frequency, required that air data be used as flight control feedback. This condition requires that these data be measured with accuracy and high fidelity. Most air data information is provided by pneumatic pressure measuring sensors. Typically unsteady pressure data provided by pneumatic sensing systems are distorted at high frequencies. The distortion is a result of the pressure being transmitted to the pressure sensor through a length of connective tubing. The pressure is distorted by frictional damping and wave reflection. As a result, air data provided all-flush, pneumatically sensed air data systems may not meet the frequency response requirements necessary for flight control augmentation. Both lab and flight test were performed at NASA-Ames to investigate the effects of this high frequency distortion in remotely located pressure measurement systems. Good qualitative agreement between lab and flight data are demonstrated. Results from these tests are used to describe the effects of pneumatic distortion in terms of a simple parametric model.

Whitmore, Stephen A.↗

Challenges of Mars Sample Return Lander Entry, Descent, and Landing

The proposed Mars Sample Return (MSR) campaign would be perhaps the most ambitious robotic mission ever attempted in space exploration. The notional cam-paign consists of three Flagship-class missions operating in cooperation for over a decade in order to return samples of the Martian surface and atmosphere to Earth for analysis. The Mars 2020 rover, scheduled to launch in July 2020, will cache samples and place them on the surface for possible return. The second mission would be a Sample Return Lander (SRL) that consists of a small Sample Fetch Rover (SFR) to gather the samples, a Sample Transfer Arm (STA) to load the samples into a Mars Ascent Vehicle (MAV), and the MAV itself to launch the samples into orbit around Mars. The third mission would be an Earth Return Or-biter (ERO) designed to rendezvous and capture the Orbiting Sample (OS), return to Earth, and separate the Earth Entry Vehicle (EEV) for Entry, Descent, and Landing (EDL) at a location to be determined. This paper will focus on the SRL mission concept, specifically the EDL phase. Given the ambitious SRL sample re-trieval baseline surface mission, including a rocket launch of the samples into Mars orbit, it is estimated that the EDL system may be required to deliver as much as 2100 kg of dry mass to the surface. This represents an approximate 20-25% in-crease in mass capability over previous landed Mars missions. Additionally, there is a high probability that SRL would have to land very close to the samples on the surface to expedite retrieval operations; therefore, Pin Point Landing (PPL) accu-racy may be required. To address these challenges, promising EDL configuration augmentations were studied to include larger forebody/higher drag entry capsules, hypersonic/supersonic inflatable/non-inflatable aerodynamic decelerators, hypersonic trim tabs, ballute drag devices, larger parachutes, higher Mach and higher dynamic pressure parachute deployments, lower parachute deployment altitudes having shorter chute timelines necessitating more efficient terrain sensor strategies, and ad-ditional fuel for longer powered descent diverts to the target landing site. Over-arching the entire trade study was an attempt to stay as close to the experience base of past successful missions as possible to reduce implementation cost and risk. This paper will discuss the entire SRL EDL trade study in detail. The information presented about the potential MSR campaign is pre-decisional and is provided for planning and discussion purposes only.

Ivanov, Mark C.↗

Investigation of Space Interferometer Control Using Imaging Sensor Output Feedback

Numerous space interferometry missions are planned for the next decade to verify different enabling technologies towards very-long-baseline interferometry to achieve high-resolution imaging and high-precision measurements. These objectives will require coordinated formations of spacecraft separately carrying optical elements comprising the interferometer. High-precision sensing and control of the spacecraft and the interferometer-component payloads are necessary to deliver sub-wavelength accuracy to achieve the scientific objectives. For these missions, the primary scientific product of interferometer measurements may be the only source of data available at the precision required to maintain the spacecraft and interferometer-component formation. A concept is studied for detecting the interferometer's optical configuration errors based on information extracted from the interferometer sensor output. It enables precision control of the optical components, and, in cases of space interferometers requiring formation flight of spacecraft that comprise the elements of a distributed instrument, it enables the control of the formation flying vehicles because independent navigation or ranging sensors cannot deliver the high-precision metrology over the entire required geometry. Since the concept can act on the quality of the interferometer output directly, it can detect errors outside the capability of traditional metrology instruments, and provide the means needed to augment the traditional instrumentation to enable enhanced performance. Specific analyses performed in this study include the application of signal-processing and image-processing techniques to solve the problems of interferometer aperture baseline control, interferometer pointing, and orientation of multiple interferometer aperture pairs.

Cheng, Victore H. L.↗