Search NASA⌕ Search

SEARCH · Search NASA

Results for “site evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Bringing Automated Fault Detection and Diagnostics Tools for HVAC&R Into the Mainstream

Heating, ventilation, and air-conditioning (HVAC) systems consume over 5 quads of energy annually, representing 30% of energy consumption in the U.S. commercial buildings. Additionally, commercial refrigeration (R) systems add about 1 quad to commercial buildings energy consumption. Most HVAC systems operate with one or more faults that result in increased energy consumption. Fault detection and diagnostics (FDD) tools have been developed to address this national issue, and many tools are commercially available. FDD tools have the potential to save considerable energy for an existing commercial rooftop unit (RTU) and refrigeration systems. These devices can be used for both retro commissioning and, when faults are addressed, continuous commissioning. However, there appears to be multiple market barriers for this technology. Although there are efforts to develop FDD tool standards, currently there are no standards and methods to define functions, capabilities, accuracy, and reliability of FDD tools in the field. Moreover, most of the commercial FDD tools have not been verified in the field independently. This paper presents a comprehensive approach for bringing HVAC FDD tools into the mainstream. The approach involves demonstrating ten commercially available FDD tools installed at ten different sites, independent testing and evaluation of the FDD tools, communication with various stakeholders, identifying and assessing market barriers, creating a process evaluation methodology, and assisting utility companies in developing incentive programs. Furthermore, the preliminary baseline results from the case study demonstrate how the use of an independent monitoring system (IMS) can be used for ground-truth in evaluating FDD tools in the field.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Assessment for the Disposal of Low Level Waste in the 200 East Area Burial Grounds (FY2019 Annual Status Report)

This annual review provides the projected dose estimates of radionuclide inventories disposed in the 200 East Area Low-Level Waste Burial Grounds (LLBGs) since September 26, 1988. These estimates are calculated using the original dose methodology developed in the performance assessment (PA) analysis (WHC-SD-WM-TI-730) and are compared with U.S. Department of Energy requirements (DOE O 435.1 and performance objectives defined in companion documents DOE M 435.1 and DOE-STD-5002-2017). All performance objectives are currently satisfied, and operational waste acceptance criteria (HNF-EP-0063) and waste acceptance practices continue to be sufficient to maintain compliance with performance objectives. Inventory estimates and associated dose estimates from future waste disposal actions are unchanged from previous years’ evaluations, indicating that potential impacts are well below performance objectives; therefore, future compliance with DOE O 435.1 is expected. A new PA study has been initiated in this fiscal year (FY) 2019 for evaluation of active disposal sites within the 200 West and East Areas (Trenches 31 and 34 in 200 West; Trench 94 in 200 East) because extended time has elapsed between the current annual status report and the original PA (WHC-SD-WM-TI-370) for the active disposal sites. The new PA for the active disposal sites is expected to be completed in FY 2021.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Annual Status Report (FY 2020): Performance Assessment for the Disposal of Low Level Waste in the 200 East Area Burial Grounds

This annual review provides the projected dose estimates of radionuclide inventories disposed in the 200 East Area Low-Level Waste Burial Grounds (LLBGs) since September 26, 1988. These estimates are calculated using the original dose methodology developed in the performance assessment (PA) analysis (WHC-SD-WM-TI-730). The estimates are compared with requirements of DOE O 435.1 Chg 1 and performance objectives defined in companion documents DOE M 435.1-1 Chg 1and DOE-STD-5002-2017). All performance objectives are currently satisfied, and operational waste acceptance criteria (HNF-EP-0063) and waste acceptance practices continue to be sufficient to maintain compliance with performance objectives. Inventory estimates and associated dose estimates from future waste disposal actions are unchanged from previous years’ evaluations that indicate potential impacts well below performance objectives; therefore, future compliance with DOE O 435.1 Chg 1 is expected. A new PA study was initiated in fiscal year (FY) 2019 for evaluation of active disposal sites within the 200 East and 200 West Areas (Trench 94 in 200 East; Trenches 31 and 34 in 200 West) due to extended time elapsing between the current annual status report and the original PA for the active disposal sites. The new PA for the active disposal sites is expected to be completed in FY 2021. Within the active burial grounds in the 200 East Area, low-level waste and mixed low-level waste will continue to be disposed of in the dedicated U.S. Navy reactor compartment trench at the 218-E-12B Burial Ground (Trench 94). During this reporting period (FY 2020, from October 1, 2019, through September 30, 2020), two reactor compartments were disposed in Trench 94. Results from sorption experiments are summarized for this reporting period to quantify the efficacy of concrete waste forms in retaining key radionuclides (e.g., technetium-99 and iodine-129). The test durations ranged from 1 to 3 months. Continued groundwater monitoring of the 200 East Area LLBGs indicates no groundwater contamination due to LLBG waste. Current assumptions about future land use at the Hanford Site are consistent with PA analysis1 assumptions of a post-closure facility that will not be degraded by human activity. The LLBGs are located in an area identified for waste management and containment of residual contamination. This area will remain after final environmental remediation and the proposed shrinkage of Hanford Site boundaries to small sections within the 200 East and 200 West Areas in the Central Plateau (DOE/EIS-0391). The current closure plan for the LLBGs (DOE/RL-2000-707) estimates that the 200 East LLBGs will be closed in the 2050 timeframe. The Disposal Authorization Statement, other technical basis documents, and the radioactive waste management basis are of continued adequacy to meet the performance objectives of DOE O 435.1 Chg 1. Overall, there are no substantive changes to primary PA assumptions nor the PA analysis conclusion; therefore, compliance with DOE O 435.1 Chg 1 and the Disposal Authorization Statement is maintained.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Building 23-117, Administration Building, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE) National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to update the façade of Building 23-117, Administration Building (Nevada State Historic Preservation Office [SHPO] Resource No. B15256), at the Nevada National Security Site (NNSS) in Nye County, Nevada. The NNSA/NFO is implementing a long-term project to modernize the town of Mercury for future mission needs. The project is considered an undertaking subject to review under Title 54 of United States Code (USC) § 306108, commonly known as Section 106 of the National Historic Preservation Act, Title 54 USC § 300101, et seq., and its implementing regulations, Title 36 of the Code of Federal Regulations (36 CFR) Part 800.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Nitrate, Nitrite, Ammonia, and Tritium in D0220 Cores

This report describes characterization of nitrogen species (nitrate, nitrite, ammonia) in aqueous and solid phases in cores taken in borehole D0220 (well 299-E25-245) under crib 216-A-37-1 at the Hanford Site in 2022 to evaluate (a) the types of nitrogen species currently in the vadose zone and (b) the migration of nitrogen species in the vadose zone. Ammonia and tritium from PUREX decladding condensate were sporadically discharged to the crib from 1977 to 1989. During discharge operations, the estimated travel time through the vadose zone to groundwater was 2.5 to 9 months. By 2003, a characterization borehole (C4106) showed residual pore water with elevated tritium and nitrate in the first 100 ft of the vadose zone, which is likely from the crib. However, there was significantly more nitrate present at the shallowest depth (15 to 22 ft), which may indicate a different source for nitrate, such as adsorbed ammonia slowly being oxidized or nitrogen species precipitates slowly dissolving. In this study, more extensive nitrogen species characterization was done on D0220 cores (drilled in 2022) at 40- and 262-ft depths, which included (a) aqueous nitrate, nitrite, and tritium; (b) adsorbed ammonia; (c) nitrogen in carbonates (or other minerals dissolved in acidic acid); (d) nitrogen in iron oxides (or other minerals dissolved in oxalic acid); and (e) nitrogen in hard-to-extract minerals (minerals dissolved in nitric acid). High pore water nitrate (226 to 331 mg/L) at 40-ft depth measured in D0220 (2022) compared to 60 mg/L at 40-ft depth in C4106 (2003) may indicate nitrate is migrating deeper. Tritium concentrations (pore water 132,000 to 148,000 pCi/L) measured in D0220 at 40-ft depth in 2022 were considerably higher than in C4106 at 40-ft depth (160 pCi/L). Additional nitrogen species mass was present in adsorbed and precipitated phases in D0220 cores. Low adsorbed ammonia was measured at 40.1- and 261.7-ft depths. Low concentrations of carbonate associated nitrogen and iron oxide-associated nitrogen were present at 40.1 and 40.6 ft depths. Nitrogen species in solid phase extractions indicate nitrogen precipitates or aqueous nitrate or ammonia trapped in sediment microfractures that are coated by precipitates. Overall, the nitrogen species and tritium characterization at two depths in D0220 showed that additional nitrogen species were present in the vadose zone. In addition, elevated pore water nitrate in D0220 at 40 ft depth from 2022 may indicate vertical migration compared to C4106 nitrate profile from 2003. Analysis of additional depths in D0220 and spatial variability of the nitrate plume along the length of the crib (from surface electrical resistivity) would be extremely useful for this comparison.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling Protocol for Evaluation of Air Emissions for the Idaho National Laboratory Site-wide Permit to Construct and Facility Emission Cap (PTC/FEC)

This document outlines the methods to be used for calculating non-radiological air quality impacts from proposed emissions at the Idaho National Laboratory (INL) Site in support of applying for a renewal to a Permit to Construct with a Facility Emissions Cap (PTC/FEC). The INL Site is seeking to maintain a state enforceable limit on emissions to maintain synthetic minor status in accordance with Idaho Administrative Procedures Act (IDAPA) 58.01.01.175-181 and IDAPA 58.01.01.200-228.

54 ENVIRONMENTAL SCIENCES↗

Enhancing the EVI-X National Framework to Address Emerging Questions on Charging Infrastructure Deployment

As national investments in EV charging infrastructure accelerate, this project advances the state-of-the-art in infrastructure analysis to better inform deployment strategies. It enhances NLR's EVI-X Suite, a set of tools supporting national network planning, local site design, and financial evaluation. These capabilities will position VTO to provide timely analysis to the DOT/DOE Joint Office, and to guide the strategic buildout of the national charging network. EVI-X development is closely coordinated with other VTO-funded efforts to ensure consistent, integrated use of key inputs and outputs, including EV adoption scenarios from TEMPO and infrastructure designs developed through EVs@Scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improved method for temporally interpolating radiosonde profiles in the convective boundary layer

A significantly improved technique for temporally interpolating radiosonde (RS) profiles of potential temperature and water vapor mixing ratio in the planetary boundary layer during daytime is introduced. The key innovation of this technique is its operation on a height grid normalized with the planetary boundary layer height. This study utilized a three-month dataset of three-hourly soundings from the Atmospheric Radiation Measurement Facility's Southern Great Plains site. The technique was evaluated for convective boundary layer cases, with the necessary boundary layer height data obtained from a ground-based infrared spectrometer. A total of 79 comparisons were conducted between reference soundings and interpolated profiles that did and did not employ height normalization. The results demonstrated a substantial improvement in the representation of interpolated profiles using the new technique, characterized by enhanced correlation, improved amplitude representation, and reduced bias for potential temperature, as well as improved correlation and reduced bias for water vapor mixing ratio.

convective boundary layer↗

Enhancing the EVI-X National Framework to Address Emerging Energy Questions

This project advances the state-of-the-art in infrastructure analysis to better inform deployment strategies. It enhances NLR's EVI-X Suite, a set of tools supporting national network planning, local site design, and financial evaluation. These capabilities will position DOE to provide timely analysis and inform the strategic buildout of the national charging network. EVI-X development is closely coordinated with other DOE-funded efforts to ensure consistent, integrated use of key inputs and outputs, including EV adoption scenarios from NLR's TEMPO model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Classifying thermodynamic cloud phase using machine learning models

Vertically resolved thermodynamic cloud-phase classifications are essential for studies of atmospheric cloud and precipitation processes. The Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Thermodynamic Cloud Phase (THERMOCLDPHASE) value-added product (VAP) uses a multi-sensor approach to classify the thermodynamic cloud phase by combining lidar backscatter and depolarization, radar reflectivity, Doppler velocity, spectral width, microwave-radiometer-derived liquid water path, and radiosonde temperature measurements. The measured pixels are classified as ice, snow, mixed phase, liquid (cloud water), drizzle, rain, and liq_driz (liquid+drizzle). We use this product as the ground truth to train three machine learning (ML) models to predict the thermodynamic cloud phase from multi-sensor remote sensing measurements taken at the ARM North Slope of Alaska (NSA) observatory: a random forest (RF), a multi-layer perceptron (MLP), and a convolutional neural network (CNN) with a U-Net architecture. Evaluations against the outputs of the THERMOCLDPHASE VAP with 1 year of data show that the CNN outperforms the other two models, achieving the highest test accuracy, F1 score, and mean intersection over union (IOU). Analysis of ML confidence scores shows that ice, rain, and snow have higher confidence scores, followed by liquid, while mixed, drizzle, and liq_driz have lower scores. Feature importance analysis reveals that the mean Doppler velocity and vertically resolved temperature are the most influential data streams for ML thermodynamic cloud-phase predictions. Lidar measurements exhibit lower feature importance due to rapid signal attenuation caused by the frequent presence of persistent low-level clouds at the NSA site. The ML models' generalization capacity is further evaluated by applying them at another Arctic ARM site in Norway using data taken during the ARM Cold-Air Outbreaks in the Marine Boundary Layer Experiment (COMBLE) field campaign. The models demonstrated similar performance to that observed at the NSA site. Finally, we evaluate the ML models' response to simulated instrument outages and signal degradation and show that a CNN U-Net model trained with input channel dropouts performs better when input fields are missing.

ARM Aerial Facility↗

Use of an Alternative Conceptual Model of Vadose Zone Heterogeneity to Evaluate Past Tank Leaks and Other Unplanned Releases within a Tank Farm at the Hanford Site - 20061

Washington State Department of Ecology (Ecology) requested that U.S. Department of Energy (DOE)-Office of River Protection (ORP) consider an evaluation of effects of fine-grained thin sediment layers on transport with a separate alternative conceptual model in its evaluation of the potential impact of tank leaks and other unplanned releases within the tank farm at the Hanford Site. For this alternative model, Ecology recommended that the model be developed based on the general framework of fine-grained units identified by a stakeholder group in their interpretations of variability in moisture content data collected in the vicinity of Waste Management Area (WMA) C. In discussions with DOE-ORP, Ecology acknowledged that the underlying data and interpretations of the occurrence and lateral continuity of the fine-grained thin layers identified by a stakeholder group are uncertain. However, DOE-ORP agreed to Ecology's recommendation and has provided support for the requested evaluation that involved development of an alternative model based on the general framework of the unpublished report by the stakeholder. DOE-ORP considered this evaluation to be a hypothetical evaluation of vadose zone heterogeneities at WMA C. General observations from the range of simulation cases examined in the evaluation of the effects of hypothetical vadose zone heterogeneities at WMA C are as follows. - The movement of the center of mass of the simulated plumes was generally vertically downward below the source for all simulations, including those that incorporated the hypothetical fine-grained units. - All simulations that incorporated hypothetical heterogeneity produced additional plume spreading over what was produced in simulations using Equivalent Homogeneous Media (EHM) model(s)a. The spreading resulted in a broadening of the fringes of the plume, resulting in a wider region of low concentration, but lower peak concentrations associated with the center of mass of the plume. - Simulations that used the silty-sand hydraulic properties, suggested by Ecology for the hypothetical fine-grained units, generally produced similar spreading and slightly lower peak mass flux at the water table when compared to the EHM modeling results. a The EHM-based models used at WMA C do not explicitly include small-scale fine-grained heterogeneities used in the model advocated by Ecology. - Simulations that used the silty-sand hydraulic properties, suggested by Ecology for the hypothetical fine-grained units, generally produced less spreading and an earlier arrival of mass flux at the water table when compared to the use of another set of hydraulic properties from a silty-sand sample collected at a nearby disposal facility. - The EHM representation of the vadose zone generally produced higher peak mass flux and an earlier occurrence of peak fluxes at the water table compared to all analyses incorporating additional hypothetical heterogeneity. Results of this alternative model evaluation of past leaks provided some insight into the transport effects of vadose zone heterogeneities at WMA C that helped resolve Ecology's comments and issues related to the effects of vadose zone heterogeneities on past leaks and losses from the WMA C tank farms area. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data from: "Responses of alpine plant communities to climate warming"

The Alpine Treeline Warming Experiment (ATWE) was a common garden-climate manipulation experiment set up across an elevation gradient in Niwot Ridge, in the Front Range of the Colorado Rocky Mountains, USA. The project sought to learn more about the effects of climate change on alpine and subalpine ecosystems, namely tree species ranges and alpine plant communities. Plots were experimentally manipulated using infrared heaters set up to warm plots to temperatures comparable to those projected for the year 2100. Other treatments include watering, and a combination of watering and heating. Three sites were set up at different elevations to study three tree species, with the highest-elevation “Alpine” site ( ~3540 m) containing twenty additional plots to study alpine plant communities. Data in this package originate from these unseeded alpine plots. To evaluate soil nitrogen availability given site treatments, resin bags were deployed, removed, and extracted annually to produce ammonium and nitrate/nitrite readings.--------------------------------------------------Data files within this archive are in comma-separated-values (.csv) and Microsoft Excel (.xlsx) formats. .csvs can be read and opened by Microsoft Excel, R, or any other simple text-editing software, and .xlsx files can be opened using Microsoft Excel. Geospatial data associated with this package are in .kml and ESRI shapefile (.shp) formats. .kml files can be read using Google Earth or Google Maps, and shapefiles can be read with any software compatible with the file type, such as QGIS or ESRI’s ArcMap suite.Data files in this package - excluding “Winkler_2019_ALPO_inorganic_N_allyears.csv” - are provided in both Microsoft Excel and .csv formats, for added accessibility and flexibility in workflows. File contents are identical.

54 ENVIRONMENTAL SCIENCES↗

Compilation and Evaluation of Data from Groundwater Impounded within the U12n and U12t Tunnels, Rainier and Aqueduct Mesas, Nevada National Security Site

The Department of Defense (DOD) Defense Threat Reduction Agency (DTRA) and the U.S. Department of Energy (DOE) Office of Environmental Management Nevada Program (EM NV) conducted routine physical and geochemical monitoring of water impounded behind impermeable structures placed within the U12n and U12t tunnels on the Nevada National Security Site (NNSS) (formerly the Nevada Test Site [NTS]). Desert Research Institute (DRI) conducted a semiquantitative evaluation of pressure data to determine the extent to which the tunnels have been inundated and a qualitative evaluation of monitored geochemical parameters to determine if trends exist that were indicative of hydrologic and/or geochemical processes operating behind the tunnel plugs. Data were also evaluated to determine if monitored radiological parameters exceeded primary standards associated with the Environmental Protection Agency’s (EPA) Safe Drinking Water Act (SDWA) (40 C.F.R. § 141.66).

54 ENVIRONMENTAL SCIENCES↗

Controlled workplace charging of electric vehicles: The impact of rate schedules on transformer aging

To accelerate adoption of non-residential charging for electric vehicles, sites must maximize utilization of existing electrical infrastructure. In this study we model electric vehicle charging at a workplace using real charging data and evaluate the lifetime of the site’s transformer as the number of charging stations is incrementally increased. We implement and compare a range of control schemes for workplace charging including minimizing the peak load, capping the total load, minimizing bills under different rate structures with time-of-use energy costs and demand charges, and directly minimizing the transformer’s aging. These are compared by the number of vehicles they allow the transformer to support, the transformer’s health, and the operator’s electricity bill. We draw a connection between minimizing the peak load and improving the transformer’s health. We observe that minimizing the electricity bill is the best scheme by both criteria when the bill includes a demand charge; in our experiment it allowed the infrastructure to support over 67% more cars than under uncontrolled charging. To protect the transformer we recommend that demand charges or capacity management be applied to parking lots of charging electric vehicles with high infrastructure utilization, and operators schedule charging to minimize their electricity bills.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating FRI3D for Cost Savings in Fire Hazard Analysis at DOE Sites

A fire hazard analysis, required for many U.S. Department of Energy (DOE) facilities, is a complex, cumbersome, and costly process. Fire hazard analyses may be viewed as a checkbox, but ideally and in spirit with the DOE-STD-1066, the fire hazard analysis (FHA) should be a part of the workflow and used to help in modifications, maintenance, and improving operational safety. With current FHA development processes, it is both time and cost prohibitive for true integration. A tool called Fire Risk Investigation in 3D or FRI3D was developed under the DOE Light Water Reactor Sustainability program to simplify and automate many aspects of a fire probabilistic risk analysis for existing nuclear power plants. The FRI3D tool automates fire scenarios by combining approved fire simulation codes, U.S. Nuclear Regulatory Commission fire calculations methods, 3D modeling and visualization, and probabilistic risk analysis models into a single workflow supported with a user interface. FRI3D was initially designed for used in combination with a PRA, this case study, evaluated using FRI3D for a plant modification, determined the benefits that detailed fire modeling can have for U.S. Department of Energy facilities with or without a PRA model. It also looked at what tasks from DOE requirements could be reduced using the tool and what is needed to integrate fire hazard analysis into site workflow.

97 - MATHEMATICS AND COMPUTING↗

Evaluation of H-Canyon Ventilation Exhaust Tunnel Inspection at the Savannah River Site - 20052

The Department of Energy (DOE) H-Canyon Facility at the Savannah River Site (SRS) is operated by Savannah River Nuclear Solutions (SRNS). The Facility Structural Integrity Program [1] provides a process to inspect, evaluate, and document the conditions of passive safety related structural systems and components, their degradation mechanisms and their impact on the safety envelope. The Structural Integrity Program performs periodic visual inspections to confirm the systems and components can perform their safety function and recommend corrective actions before the function is compromised. The H-Canyon Exhaust Tunnel is part of the H-Canyon Ventilation System and is periodically inspected under the Structural Integrity Program. The Tunnel performs a Safety Class passive design feature function that is available 100% of the time. The underground reinforced concrete Tunnel directs Canyon process air from the Canyon to the Sand Filter System. The radiological and chemical airborne activity coupled with the physical configuration of the tunnel precludes a manned entry into the tunnel to perform the inspection. Unlike active systems that can be subjected to physical testing to confirm capability, qualification calculations, including modeling, is performed to assess passive design feature capabilities relative to operational, accident and natural phenomena hazards events. Input for these calculations come from knowledge of field conditions, design drawings and conservative assumptions. The knowledge of field conditions comes from concrete and soil testing activities as well as inspection data. The use of cameras on crawlers to obtain inspection data and how that data is used in qualification calculations is the focus of this discussion. Remote Tunnel inspections have been performed using cameras on a stick, referred to as pole cameras, prior to Calendar Year 2003 (CY2003). Since CY2003, six camera equipped crawlers have been used. Crawlers have evolved and improved by incorporating lessons learned from the previous inspections. The latest 2019 crawler successfully traveled the entire length of the tunnel between the Canyon and Sand Filter System and captured images that were previously unseen, thus providing key visual data for the Structural Integrity Program report [2]. The inspection data serves as 1) input to qualification calculations, 2) validates current conditions remain bounded by qualification calculations, and 3) documents a record of change over time. This data is vital for the effective evaluation of the tunnel structure and aids with predicting the life cycle service life safety envelope to protect the public, environment, and facility worker. The goal of the 2019 deployment was to use a more robust vehicle to ensure travel over obstacles, perform the inspection with higher resolution cameras, and have the ability to elevate the cameras to view surfaces previously obscured by abandon-in-place ducts in the tunnel. The inspection information will serve to strengthen the input basis for qualification calculations, versus using excessive conservative calculation assumptions. This 2019 inspection was compared with previous crawler visual evidence to identify change over time to project remaining service life and confirm field conditions remain bounded by qualification calculations. The results of the 2019 Exhaust Tunnel inspection continue to improve and provide a firm basis to make sound engineering judgements regarding tunnel capability and approaches in projecting remaining service life with an aging system and component. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pantex Plant Ogallala Aquifer and Perched Groundwater Contingency Plan

The Pantex Plant Ogallala Aquifer and Perched Groundwater Contingency Plan has been developed in accordance with the requirements identified in the: • Interagency Agreement for the Pantex Superfund Site, Article 8.5 Work to be Performed, • Compliance Plan Provision of Hazardous Waste Permit No. 50284, and • Record of Decision for Groundwater, Soil, and Associated Media, Pantex Plant. A Long‐Term Monitoring System Design has been designed to monitor conditions in the perched groundwater including changes in the perched aquifer as a result of implementing the response actions. Monitoring is required for verifying the effectiveness of perched groundwater response actions (i.e., conditions in the perched aquifer are being affected as intended) and for confirming that the perched aquifer and Ogallala Aquifer characterization as defined in the Resource Conservation and Recovery Act Facility Investigation Report and the Corrective Measure Studies/Feasibility Study remains accurate. If monitoring results obtained through the monitoring network identify an unexpected condition or deviation, contingent actions will be considered and implemented as necessary to ensure continued protection of the Ogallala Aquifer and human health and the environment. Potential deviations to expected technology performance may be encountered for each of the four primary response actions that compose the selected remedy for perched groundwater; Playa 1 Pump and Treat System, Southeast Area Pump and Treat System, Southeast Area In‐Situ Bioremediation System (comprised of the Southeast In‐Situ Bioremediation System Original System, Southeast Area In‐Situ Bioremediation System Extension System, Offsite In‐Situ Bioremediation System, Perchlorate/Chromium ISB, Northeast ISB and County Road 8 ISB), and Zone 11 In‐Situ Bioremediation System. Monitoring will also be conducted to determine if there are deviations to the expected characterization, e.g., contaminants not expected as a result of the RCRA Facility Investigation characterization. Deviations to expected conditions in the Ogallala Aquifer could also be encountered if the response actions in the perched groundwater are not performing as expected, i.e., preventing contaminants from migrating to the Ogallala Aquifer. Currently, Pantex has begun investigation of detections of high explosives above groundwater protection standards in wells on the Texas Tech University property and a plume that is moving to the northeast from that area. Due to those detections, this Plan recognizes the fact that future detections in the Ogallala will be focused on first‐ time detections of analytes. After a remedy is determined, this Plan will require modification to address-deviations and contingent actions. This Plan was developed to identify the contingent actions necessary to mitigate impacts resulting from deviations to site conditions or response action performance. The Plan defines the environmental problem being addressed by the response actions, clarifies the expected conditions and objectives of the response actions, and identifies the potential deviations to the response actions (due to site conditions or technology performance) that could be encountered. The deviations were evaluated to determine the likelihood of occurrence, potential impact, and time to respond to avoid impact. The Plan also identifies the monitoring outlined in the Long‐Term Monitoring System Design Report (Consolidated Nuclear Security, 2024) and Sampling Analysis Plan (PanTeXas Deterrence, 2024) that will be used to detect the deviations. Lastly, the Plan specifies the contingent actions that could be implemented in response to the deviations. Because each response focuses on a discrete portion of the perched aquifer and contaminant plume, each response action has a different set of expected conditions, and therefore differing impacts from deviations to the site and technology expectations. As a result, the contingent actions are identified for each response action and potential deviation including specific constituents, location, and conditions. If deviations are encountered that impact the ability of the response action to meet performance objectives, the contingent actions will be focused on ensuring the response action can meet the performance objective. Contingent actions may be implemented as interim actions (ISMs/removal actions) in accordance with the Record of Decision, Interagency Agreement, and Hazardous Waste Permit‐50284, if warranted by the specific circumstances. For deviations to site characterization expected conditions, the contingent action will focus on determination of the source of the deviation, determination of the appropriate response, and evaluation of additional work to be completed. However, if the deviation to characterization impacts the performance of the response action, the contingent action will again focus on ensuring performance objectives can be met. Early source term removals and cleanup actions have been implemented to protect the Ogallala Aquifer. Because of these actions and based on modeling results, the expected conditions in the Ogallala Aquifer are that constituents of concern will not be detected above the Groundwater Protection Standards (GWPSs) nor will they reach potential points of exposure above the GWPS. The primary deviation of concern for the Ogallala is if constituents are detected in the Ogallala Aquifer near or above GWPSs. If it occurs, this change in expected conditions would require further evaluation of site and contaminant characteristics to determine an appropriate course of action. The evaluation would include additional monitoring, source identification, implementation of interim protective measures (if necessary), and delineation of extent. These evaluations are necessary to determine an appropriate response action for the Ogallala. The primary goal of the Plan is to provide for the continued protection of the Ogallala Aquifer and the health of its consumers. In recognition, this Plan presents a flexible and rational approach for making future decisions associated with confirming the change in perched and Ogallala aquifer conditions and identifying a response (technical activities, changes to response actions, regulatory oversight, and public involvement).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗