Search NASA⌕ Search

SEARCH · Search NASA

Results for “sludge process”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Evaluation of a Turbidity Meter for Use at the Defense Waste Processing Facility

Savannah River Remediation’s (SRR’s) Defense Waste Processing Facility (DWPF) Laboratory currently tests for sludge carry-over into the Recycle Collection Tank (RCT) by evaluating the iron concentration in the Slurry Mix Evaporator Condensate Tank (SMECT) and relating this iron concentration to the amount of sludge solids present. A new method was proposed for detecting the amount of sludge in the SMECT that involves the use of an Optek turbidity sensor. Waste Services Laboratory (WSL) personnel conducted testing on two of these units following a test plan developed by Waste Solidification Engineering (WSE). Both Optek units (SN64217 and SN65164) use sensor model AF16-N and signal converter model series C4000. The sensor body of each unit was modified to hold a standard DWPF 12 cc sample vial, also known as a “peanut” vial. The purpose of this testing was to evaluate the use of this model of turbidity sensor, or meter, to provide a measurement of the sludge solids present in the SMECT based upon samples from that tank. During discussions of the results from this study by WSE, WSL, and Savannah River National Laboratory (SRNL) personnel, an upper limit on the acceptable level of solids in SMECT samples was set at 0.14 weight percent (wt%). A “go/no-go” decision criterion was to be developed for the critical turbidity response, which is expressed in concentration units (CUs), for each Optek unit based upon the 0.14 wt% solids value. An acceptable or a “go” decision for the SMECT should reflect the situation that there is an identified risk (e.g. 5%) for a CU response from the Optek unit to be less than the critical CU value when the solids content of the SMECT is actually 0.14 wt% or greater, while a “no-go” determination (i.e., an Optek CU response above the critical CU value, a conservative decision relative to risk) would lead to additional evaluations of the SMECT to better quantify the possible solids content of the tank. Subsequent to the issuance of the initial version of this report but under the scope of the original request for technical assistance, WSE asked for this report to be revised to include the “go/no-go” CU value corresponding to 0.28 wt% solids. It was this request that led to the preparation of Revision 1 of the report. The results for the 0.28 wt% solids value were developed following the same approach as that utilized for the 0.14 wt% solids value. A sludge simulant was used to develop standards for testing both Optek units and to determine the viability of a “go/no-go” CU response for each of the units. Statistical methods were used by SRNL to develop the critical CU value for the “go/no-go” decision for these standards for each Optek unit. Since only one sludge simulant was available for this testing, the sensitivity of these results to other simulants and to actual sludge material is not known. However, limited testing with samples from the actual DWPF process (both SRAT product samples and SMECT samples) demonstrated that the use of the “go/no-go” criteria developed from the sludge simulant testing was conservative for these samples taken from the sludge batch, Sludge Batch 7b, being processed at the time of this testing. While both of the Optek units performed very reliably during this testing, there were statistically significant differences (although small on a practical scale) between the two units. Thus, testing should be conducted on any new unit of this Optek model to qualify it before it is used to support the DWPF operation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Key Results from SB8 Simulant Flowsheet Studies

Key technically reviewed results are presented here in support of the Defense Waste Processing Facility (DWPF) acceptance of Sludge Batch 8 (SB8). This report summarizes results from simulant flowsheet studies of the DWPF Chemical Process Cell (CPC). Results include: • Hydrogen generation rate for the Sludge Receipt and Adjustment Tank (SRAT) and Slurry Mix Evaporator (SME) cycles of the CPC on a 6,000 gallon basis; • Volume percent of nitrous oxide, N 2 O, produced during the SRAT cycle; • Ammonium ion concentrations recovered from the SRAT and SME off-gas; and, • Dried weight percent solids (insoluble, soluble, and total) measurements and density.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Membrane-based solvent extraction for the recovery of rare earths from phosphate mining process streams

This study reports on the capture of rare earth elements (REEs) from phosphate industry process streams, including phosphoric acid (PA) sludge and phosphogypsum (PG), using a membrane solvent extraction (MSX) process. While MSX has been proven effective for a relatively concentrated feed, its effectiveness for dilute REEs solutions remains unexplored. Investigated PA-sludge and PG particles contain total REEs concentrations of ∼1100 and ∼320 ppm, respectively. Acid leaching, implemented to dissolve the REEs, significantly dilutes the REEs concentration to ∼210 ppm for PA-sludge leachate and ∼60 ppm for PG leachate. These low concentrations, compounded by the higher levels of non-REE ions and radioactive species, uranium (U) and thorium (Th), poses challenges to the MSX process. Here, we demonstrated that N,N,N′,N′-tetraoctyl-diglycolamide (TODGA) selectively binds REEs from a >3 M nitric-acid leachate while effectively rejecting U and Th. Concentrations of light REEs in strip solution were doubled compared to the feed, while heavy REEs were preferentially extracted. Furthermore, >99% purity gypsum, free of U and Th, was precipitated during the acid leaching process, aiding separation by removing significant amounts of non-REEs species (e.g., calcium) prior to the MSX process. Molecular simulations support the experimental data, suggesting preferential separation of heavy over light REEs. Based on these results, a cost-effective integrated process including pretreatment, acid leaching, MSX, and wastewater treatment is proposed for the co-recovery of REEs, phosphoric acid, gypsum, and U. This study shows MSX as a technically and economically feasible process for the recovery of REEs from low-concentration process streams, offering advantages over conventional solvent extraction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Settler Tank, KW Container and KE Container Sludge Simulants

The Sludge Treatment Project (STP), managed by CH2M Hill Plateau Remediation Company (CHPRC) has specified base formulations for non-radioactive sludge simulants for use in the development and testing of equipment for sludge sampling, retrieval, transport, and processing. In general, the simulant formulations are based on the average or design-basis physical and chemical properties obtained by characterizing sludge samples. The simulants include surrogates for uranium metal, uranium oxides (agglomerates and fine particulate), and the predominant chemical phases (iron and aluminum hydroxides, sand). Specific surrogate components were selected to match the nominal particle-size distribution and particle-density data obtained from sludge sample analysis. Under contract to CHPRC, Pacific Northwest National Laboratory (PNNL) has performed physical and rheological characterization of simulants, and the results are reported here. Two base simulant types (dry) were prepared by STP staff at the Maintenance and Storage Facility and received by PNNL in February 2009: Settler Tank Simulant and KW Container Sludge Simulant. A third simulant, KE Container Sludge Simulant was received by PNNL in December 2010. The objectives of this simulant characterization effort were to provide baseline characterization data on simulants being used by STP for process development and equipment testing and provide a high-level comparison of the simulant characteristics to the targets used to formulate the simulants.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

White Paper to Justify the Use of Strip Effluent in the Defense Waste Processing Facility During Slurry Mix Evaporator Processing

At the request of Savannah River Remediation (SRR), a white paper was written to assess whether it would be acceptable to process Strip Effluent (SE) in both the Sludge Receipt and Adjustment Tank (SRAT) and Slurry Mix Evaporator (SME) in the Defense Waste Processing Facility (DWPF) for the nitric-glycolic acid flowsheet. Savannah River National Laboratory (SRNL) experimental data and DWPF Sludge Batch 9 (SB9) process data was reviewed, looking at batches which included Precipitate Reactor Feed Tank (PRFT) and/or Strip Effluent Feed Tank (SEFT) feeds that led to long processing times. These batches were reviewed looking for processing problems such as melter feed trips, foamovers, heating rod or steam coil fouling, missed Reduction/Oxidation (REDOX) targets, and other process anomalies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sludge Batch 10 Flowsheet Testing with Non-radioactive Simulants

Fourteen Chemical Processing Cell (CPC) simulations were performed with nonradioactive sludge simulants at the Aiken County Technology Laboratory in Aiken, SC. Four of these experiments were performed with Tank 51 sludge simulant. The remaining ten were performed with Tank 40 sludge simulant. The purpose of these experiments was to elucidate the chemistry and characteristics of Sludge Batch (SB) 10 as anticipated in the Defense Waste Processing Facility (DWPF). Experiments were performed at acid stoichiometries between 76% and 138% of the Koopman Minimum Acid requirement (85% - 144% of the Hsu acid requirement) and at REDuction/OXidation (REDOX) targets between 0.1 and 0.3. Testing examined the impact of coupled operations and sludge-only operations during Sludge Receipt and Adjustment Tank (SRAT) and Slurry Mix Evaporator (SME) processing at both design basis and nominal boilup rates. This report shares conclusions made as a result of this testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cold Crucible Induction Melter (CCIM) Demonstration Using a Representative Savannah River Site Sludge Simulant On the Large-Size Pilot Platform at the CEA-Marcoule

The cold-crucible induction melter technology (CCIM) is considered worldwide for industrial implementation to overcome the current limits of high level waste vitrification technologies and to answer future challenges such as: new or difficult sludge compositions, need for improving waste loading, need for high temperatures, and corrosive effluents. More particularly, this technology is being considered for implementation at the US DOE Savannah River site to increase the rate of waste processing while reducing the number of HLW canisters to be produced through increased waste loading and improved waste throughput. A collaborative program involving AREVA, CEA (French Atomic Energy Commission), SRNL (Savannah River National Laboratory) and WSRC (Washington Savannah River Company) has thus been initiated in 2007 to demonstrate vitrification with waste loadings on the order of 50% (versus the current DWPF waste loading of about 35%) with a PUREX-type waste composition (high Fe{sub 2}O{sub 3} composition), and to perform two pilot-scale runs on the large size platform equipped with a 650 mm diameter CCIM at the CEA Marcoule. The objectives of the demonstrations were 1) to show the feasibility of processing a representative SRS sludge surrogate using continuous slurry feeding, 2) to produce a glass that would meet the acceptance specifications with an increased waste loading when compared to what is presently achieved at the DWPF, and 3) achieve improved waste throughputs. This presentation describes the platform and the very encouraging results obtained from the demonstration performed at temperatures, specific throughputs and waste loadings that overcome current DWPF limits. Results from the initial exploratory run and second demonstration run include 1) production of a glass product that achieved the targeted glass composition that was more durable than the standard Environmental Assessment (EA) glass, 2) successful slurry feeding of the CCIM, and 3) promising waste processing rates (at 1250 deg. C and 1300 deg. C melt pool temperature) that could result in processing of the Savannah River HLW faster than could be currently achieved with the existing Joule Heated melter in DWPF. In conclusion, this joint effort conducted by CEA, AREVA, SRNL and WSRC led to very encouraging results, demonstrating waste throughputs 44 % that of the DWPF ceramic melter throughput in a 650 mm CCIM melter for the same waste type with a Sludge Batch 3 PUREX-type waste feed flux of 150 L/h/m{sup 2} demonstrated at 1250 deg. C. The very high waste loading (above 52%) allows reducing the amount of glass to be produced by about 27% to treat the same amount of waste when compared to previous DWPF operation for this specific type of feed, since 27 % less glass is needed to immobilize the same amount of waste. It was also demonstrated, for this type of feed, an unusual behavior with regard to nepheline formation, which would require further evaluation for future applications. The product from the baseline demonstration run, with a waste loading of at least 52%, displayed a very good quality. Stabilized operation close to the maximum throughput was demonstrated. Cesium volatility was apparently between 7 and 12 % (based on glass analysis); however this value is only preliminary. This demonstration also allowed the CEA to better understand the SRS slurry feed behavior and to propose adaptations to the platform for any future demonstrations using this type of feed. Finally, use of a large diameter CCIM ({approx}1 meter) may allow faster processing of the SRS HLW than can be achieved with the current DWPF melter. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MELT RATE TESTING FOR SLUDGE BATCH 6

The Savannah River National Laboratory (SRNL) was requested to provide Savannah River Remediation (SRR) with a recommended frit composition for Sludge Batch 6 (SB6) to optimize processing at the Defense Waste Processing Facility (DWPF). This report discusses the results of a series of melt rate experiments that were completed in support of the frit recommendation and the preparation of the feed used in the testing. The objective of the work was to identify the impact of individual frit component concentrations on melt rate for both SB6 and for DWPF sludge batches in general. The dry fed, Melt Rate Furnace (MRF) was used to compare the relative melt rate performance of several candidate frit compositions. Sludge composition projection changes and variation led to the fabrication and testing of several new frits along with Frit 418, which is currently utilized at the DWPF for Sludge Batch 5 (SB5) processing. The melt rate testing results show that changes in the frit composition, such as increases in B{sub 2}O{sub 3} or Li{sub 2}O concentrations, can provide a faster melt rate for SB6 relative to Frit 418. However, the composition of SB6 as currently projected (February 2010 blended with a 40 inch heel of SB5) does not allow for significant changes in frit composition relative to Frit 418 without compromising the projected operating windows. Only one of the new frits tested, Frit IS7, remains viable for SB6 processing based on the current composition projections. The melt rate results also demonstrated that a low Na{sub 2}O concentration frit (particularly Frit IS7) can provide reasonable melt rates if the concentrations of Li{sub 2}O or B{sub 2}O{sub 3} in the frit are increased. The measured melt rate for Frit IS7 with the simulated SB6 feed was about 15% faster than that for Frit 418. The projected operating windows for Frits 418 and IS7 are very similar with the current SB6 projections. However, waste loadings with Frit IS7 are limited by low viscosity predictions, while waste loadings with Frit 418 are limited by predictions of nepheline crystallization. It is recommended that SRNL reevaluate the final SB6 composition once washing and blending are complete to determine whether a change in frit composition could provide improved operating windows, improved sulfate solubility, and/or increased waste throughput.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

JPL Activated Carbon Treatment System (ACTS) for sewage

An Activated Carbon Treatment System (ACTS) was developed for sewage treatment and is being applied to a one-million gallon per day sewage treatment pilot plant in Orange County California. Activities reported include pyrolysis and activation of carbon-sewage sludge, and activated carbon treatment of sewage to meet ocean discharge standards. The ACTS Sewage treatment operations include carbon-sewage treatment, primary and secondary clarifiers, gravity (multi-media) filter, filter press dewatering, flash drying of carbon-sewage filter cake, and sludge pyrolysis and activation. Tests were conducted on a laboratory scale, 10,000 gallon per day demonstration plant and pilot test equipment. Preliminary economic studies are favorable to the ACTS process relative to activated sludge treatment for a 175,000,000 gallon per day sewage treatment plant.

Source record↗

Determination of inorganic and organic priority pollutants in biosolids from meat processing industry

The biosolids (BS) generated in the wastewater treatment process of a meat processing plant were monitored and the priority pollutant content was characterized. The trace metal and organic pollutant content - polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/PCDF) - were determined quantitatively and compared to guideline limits established by the US EPA and EU. PCBs were not detected in the solid samples, while trace metals, PAHs and PCDD/PCDF were detected in concentrations below the limits established by international standards. Toxic equivalent factors were evaluated for the biosolids, and the results proved that these wastes can be safely deposited on land or used in combustion/incineration plants. Since no previous data were found for meat processing waste, comparisons were made using municipal sewage sludge data reported in the literature. Since, this report monitored part of the priority pollutants established by the US EPA for meat and poultry processing wastewater and sludge, the results verified that low pollution loads are generated by the meat processing plant located in the southern part of Brazil. However, the BS generated in the treatment processes are in accordance with the limits established for waste disposal and even for soil fertilizer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reinventing wastewater treatment plants: energy neutral treatment and enhanced fertilizer production through a novel resource recovery center

Wastewater treatment plants (WWTPs) are typically energy intensive, mainly due to the secondary treatment processes such as activated sludge (AS) for treatment of organics as well as nutrients like nitrogen. Nitrogen removal presents a big problem for WWTPs. The main form of nitrogen in wastewater is ammonium, and an AS process uses oxygen to convert ammonium into nitrite and nitrate which is then converted to nitrogen through denitrification process. During anaerobic digestion (AD), organic nitrogen gets degraded, resulting in an effluent stream (centrate) with a high nitrogen content, mostly in the form of ammonium. This contributes 15-30% of total nitrogen to the wastewater influent which further increases energy consumption for aeration. The project aims to transform this conventional municipal WWTPs into energy-neutral, resource-recovering facilities by integrating three core technologies: • Cloth Media Filtration (CMF) to replace conventional primary sedimentation (CPS) and increase the diversion of organics from the energy intensive secondary treatment to AD. This results in reduced energy demand for aeration in the secondary process while simultaneously increasing the biogas production in the anaerobic digesters. • Anerobic Digester to increase biogas and ammonia production. • Membrane Evaporation (ME) to recover ammonia from AD centrate and produce marketable fertilizer. The benefits of proposed WWTP process modifications were evaluated using techno economic analysis (TEA) and life cycle assessment (LCA). For CMF portion of the research a statistical analysis was employed to develop data-driven tools that could be used to enhance and optimize its performance in terms of energy savings and effluent quality. The main objective of this project is to reduce the energy demand for secondary treatment at municipal WWTPs by at least 50%, increase anaerobic digester (AD) biogas and ammonia production by 100% and 120%, respectively, and recover 90% of ammonia from the AD. Integrated CMF, AD, and ME was shown to work synergistically toward achieving these decarbonization targets through energy-positive treatment and fertilizer recovery techniques.

42 ENGINEERING↗

DESORPTION OF SORBATES FROM MST, MMST, AND CST UNDER VARIOUS CONDITIONS

The Small Column Ion Exchange (SCIX) Program (formerly referred to as the Modular Salt Processing (MSP) Project) seeks to deploy equipment to remove the {sup 134,137}Cs, {sup 90}Sr, and alpha-emitting radionuclides (principally {sup 238,239,240}Pu and {sup 237}Np) from the high level waste salt solutions. The equipment is installed within a high level waste tank to take advantage of the shielding provided by the waste tank. The process will involve adding monosodium titanate (MST) to the waste tank (i.e., Tank 41H) to sorb the Sr and select actinides, removing the MST and entrained sludge with in-riser rotary microfilters, and subsequently using ion-exchange columns containing crystalline silicotitanate (CST) to remove the Cs. After being loaded with Cs, the CST will be ground to reduce the particle size and then transferred into another waste tank (e.g., Tank 40H). The MST and sludge solids stream will be transported to a sludge batch preparation tank (i.e., Tank 42H or Tank 51H) once the SCIX batch is processed. Both streams, MST/solids and CST, will ultimately be transported into and vitrified inside the Defense Waste Processing Facility (DWPF). A series of experiments were performed to examine desorption from monosodium titanate (MST), modified monosodium titanate (mMST), and crystalline silicotitanate (CST) under various conditions. The first two experiments examined desorption from MST and CST under two different sludge treatment processes, aluminum dissolution and sludge washing. Desorption of all sorbates was observed to varying degrees under the aluminum dissolution conditions. The extent of desorption ranged from < 3% to about 50% after 4 weeks, with Pu exhibiting the lowest desorption. At the end of the experiment, the temperature was reduced from 65 C to 25 C and the tests monitored for an additional two weeks. After reducing the temperature, partial resorption of the sorbates was observed with both MST and CST. Under the sludge washing conditions, no desorption of sorbates was observed with MST; however, some additional sorption did occur. For CST, a small amount of Cs leached from the material during the first day of testing, but no further leaching was observed over the remaining test period. The final test was designed to examine the possibility of desorption from both MST and mMST upon increasing the solid to liquid phase ratio. The results of these tests indicated some desorption of Pu from MST within the first two weeks after changing the phase ratio, then resorption of some of the leached Pu over the remaining 4 weeks of the experiment. No desorption of any sorbates was observed for mMST under these conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Corrosion Testing of Carbon Steel Exposed to Sludge Heel Chemical Cleaning Solutions - 16109

As efforts continue to treat and dispose of millions of gallons of legacy radioactive materials from the production of nuclear weapons, non-compliant waste storage tanks will gradually be emptied of the bulk waste volume leaving heel materials requiring removal prior to tank closure. The waste heel slurries are distributed on the floor of large, million gallon tanks, which frequently contain numerous obstructions that limit the effectiveness of mechanical removal methods. As a result, chemical cleaning methods are needed for the effective removal of the heels as well as chemical scales that are present on the tank walls and other interior surfaces. Two tank cleaning technologies have already been implemented at the Savannah River Site (SRS): Low Temperature Aluminum Dissolution (LTAD) and Bulk Oxalic Acid Cleaning (BOAC). Recent chemical cleaning efforts on SRS Tank 12 were very successful with regard to bulk sludge heel (especially for Al, Fe, and U phases) and beta/gamma radionuclide removal. Although chemical cleaning using these technologies has been shown to be effective, no disposition path has been identified for oxalate added during BOAC, and insoluble oxalate salts are accumulating within the SRS tank farm and waste processing facilities (evaporators, etc.). Extensive sludge washing is also required to remove moderately soluble sodium oxalate salts prior to sludge vitrification in the SRS Defense Waste Processing Facility (DWPF). As a result, oxalate additions to the tank farm need to be minimized by the use of supplementary acids to assist sludge removal in OA or the use of other cleaning reagents or processing strategies. Previous SRNL testing revealed the importance of pH control for BOAC and recommended the use of a supplementary acid (dilute HNO{sub 3}) with OA to minimize oxalate additions. Primary drivers in SRS Tank Closure Performance Assessments, which evaluate the fate and impact of tank sludge residuals on a geological timescale, are the removal of alpha emitting radionuclides present at low concentrations such as Pu, Am, and Np, which are not highly soluble in currently utilized chemical cleaning reagents. Scoping studies conducted at SRNL revealed promising methods to dissolve the actinides within the HLW tank heels. Oxidation of the actinides with permanganate in either strong caustic (10 M NaOH) or dilute acidic (0.2 M HNO{sub 3}) solutions was shown to result in dissolution of oxy/hydroxide phases of these metals in the absence of major sludge phases. The waste tanks at SRS and Hanford are constructed of carbon steel. Carbon steel corrodes rapidly in most acidic and/or oxidizing environments. Previous electrochemical corrosion testing indicated that the corrosion rates in dilute HNO{sub 3} with OA may result in manageable corrosion rates, over short exposure periods. Additional corrosion testing was performed to provide data for the nitric acid/OA blend as well as the acid/permanganate and caustic permanganate based chemical cleaning solutions. Corrosion rates from the passive coupon tests for the nitric acid/oxalic acid blend were significantly greater than those observed previously with the electrochemical testing. This result may be due to simultaneous electrochemical and chemical dissolution of the steel. The corrosion rate data from the coupon tests in the nitric acid/oxalic acid blend were evaluated to determine the degree of potential structural damage. The corrosion rates, although relatively high, would not be expected to cause damage that would reduce the capacity of the tank primary wall if the process is completed within a month. The corrosivity of sodium permanganate in four proposed cleaning solutions, 1 nitric acid solution and 3 sodium hydroxide solutions, was studied by electrochemical methods at room temperature. The corrosion rates were significantly less aggressive than in the nitric acid/oxalic acid blend corrosion tests. Passive coupon tests needs to be performed in these solutions to ensure that chemical dissolution of the metal is not occurring simultaneously. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determining the Solubility Behavior of Kogarkoite in Simulated Nuclear Waste

Kogarkoite (Na 3 FSO 4 ) is a sparingly soluble fluoride–sulfate double salt that has been identified in high level nuclear waste sludge at the Hanford Site and, more recently, in sludge batch compilation samples at the Savannah River Site (SRS). Due to its complex dissolution behavior, which exhibits an inverse dependence on sodium ion activity, the presence of this mineral poses significant challenges to waste retrieval and processing. Incomplete dissolution during sludge washing can lead to the retention of fluoride and sulfate in the high-level waste feed, potentially causing the formation of corrosive, immiscible molten salt layers, known as "glass gall,” in vitrification melters. Current efforts to optimize flowsheet parameters and wash-water volumes are hindered by the absence of a commercially available, certified reference material, which prevents the accurate calibration of analytical methods and the verification of dissolution kinetics. To address this critical gap, this research focuses on the laboratory synthesis of pure Kogarkoite to serve as a standard for comprehensive solubility and washing performance testing. A coupled synthesis and simulant campaign was executed using an evaporative crystallization protocol designed to replicate the dynamic concentration effects observed in tank farm operations. Thirteen simulant matrices were prepared by dissolving systematically varied ratios of sodium fluoride (NaF) and sodium sulfate (Na 2 SO 4 ) in deionized water under three distinct caustic regimes: 0.0 g (control), 4.0 g (~1 M), and 12.0 g (~3 M) sodium hydroxide (NaOH). While thermodynamic equilibrium models suggest that high-caustic environments should favor the stability of the double salt7, results from this evaporative study at 25 0 C revealed a distinct kinetic divergence. Simulants with high hydroxide loading predominantly yielded large, blocky crystals of sodium sulfate decahydrate (Na 2 SO 4 .10H 2 O). Successful synthesis of pure Kogarkoite was achieved exclusively in specific NaOH-free compositional windows, where the precipitate manifested as fine, opaque granular aggregates. Ion chromatography (IC) analysis confirmed phase purity through the simultaneous stoichiometric depletion of both fluoride and sulfate from the supernatant. This successful synthesis establishes a reproducible route to generate bulk Kogarkoite, enabling the subsequent phase of quantitative dissolution testing using inhibited water to optimize sludge-batch assembly.

Sarker, Md Sharif [Florida International Univ. (FI↗

A Remote Absorption Process for Disposal of Evaporate and Reverse Osmosis Concentrates

Many commercial nuclear plants and DOE facilities generate secondary waste streams consisting of evaporator bottoms and reverse osmosis (RO) concentrate. Since liquids are not permitted in disposal facilities, these waste streams must be converted to dry solids, either by evaporation to dried solids or by solidification to liquid-free solids. Evaporation of the liquid wastes reduces their volume, but requires costly energy and capital equipment. In some cases, concentration of the contaminants during drying can cause the waste to exceed Class A waste for nuclear utilities or exceed DOE transuranic limits. This means that disposal costs will be increased, or that, when the Barnwell, SC disposal site closes to waste outside of the Atlantic Compact in July 2008, the waste will be precluded from disposal for the foreseeable future). Solidification with cement agents requires less energy and equipment than drying, but results in a volume increase of 50-100%. The doubling or tripling of waste weight, along with the increased volume, sharply increases shipping and disposal costs. Confronted with these unattractive alternatives, Diversified Technologies Services (DTS), in conjunction with selected nuclear utilities and D and D operations at Rocky Flats, undertook an exploratory effort to convert this liquid wastewater to a solid without using cement. This would avoid the bulking effect of cement, and permit the waste to be disposed of the Energy Solutions facility in Utah as well as some DOE facilities. To address the need for an attractive alternative to drying and cement solidification, a test program was developed using a polymer absorbent media to convert the concentrate streams to a liquid-free waste form that meets the waste acceptance criteria of the pertinent burial sites. Two approaches for mixing the polymer with the liquid were tested: mechanical mixing and in-situ incorporation. As part of this test program, a process control program (PCP) was developed that is 100% scalable from a concentrate test sample as small as 50 grams to full-scale processing of 100 cubic foot containers or larger. In summary: The absorption process offers utilities a viable and less costly alternative to on-site drying or solidification of concentrates. The absorption process can be completed by site personnel or by a vendor as a turnkey service. The process is suitable for multiple types of waste, including RO and evaporator concentrates, sludges, and other difficult to process waters and wet solids. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DEPOSITION TANK CORROSION TESTING FOR ENHANCED CHEMICAL CLEANING POST OXALIC ACID DESTRUCTION

An Enhanced Chemical Cleaning (ECC) process is being developed to aid in the high level waste tank closure at the Savannah River Site. The ECC process uses an advanced oxidation process (AOP) to destroy the oxalic acid that is used to remove residual sludge from a waste tank prior to closure. The AOP process treats the dissolved sludge with ozone to decompose the oxalic acid through reactions with hydroxyl radicals. The effluent from this oxalic acid decomposition is to be sent to a Type III waste tank and may be corrosive to these tanks. As part of the hazardous simulant testing that was conducted at the ECC vendor location, corrosion testing was conducted to determine the general corrosion rate for the deposition tank and to assess the susceptibility to localized corrosion, especially pitting. Both of these factors impact the calculation of hydrogen gas generation and the structural integrity of the tanks, which are considered safety class functions. The testing consisted of immersion and electrochemical testing of A537 carbon steel, the material of construction of Type III tanks, and 304L stainless steel, the material of construction for transfer piping. Tests were conducted in solutions removed from the destruction loop of the prototype ECC set up. Hazardous simulants, which were manufactured at SRNL, were used as representative sludges for F-area and H-area waste tanks. Oxalic acid concentrations of 1 and 2.5% were used to dissolve the sludge as a feed to the ECC process. Test solutions included the uninhibited effluent, as well as the effluent treated for corrosion control. The corrosion control options included mixing with an inhibited supernate and the addition of hydroxide. Evaporation of the uninhibited effluent was also tested since it may have a positive impact on reducing corrosion. All corrosion testing was conducted at 50 C. The uninhibited effluent was found to increase the corrosion rate by an order of magnitude from less than 1 mil per year (mpy) for an inhibited waste to a range of 5 to 23.4 mpy, depending on sludge chemistry. F-area-based effluents were, in general, more corrosive. Effective corrosion control measures included evaporation, hydroxide additions and mixing with supernates containing a representative supernate chemistry (5 M hydroxide and 1.5 M nitrite). Corrosion rates with these measures were generally 0.2 mpy. The A537 carbon steel was found to be susceptible to pitting when the corrosion control measure involved mixing the ECC effluent with a supernate chemistry having minimal inhibitor concentrations (0.5 M hydroxide and 0.3 M nitrite). Corrosion rates in this case were near 1 mpy.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MHTLS Cross-flow Heat Exchanger Temperature Performance Data

The presentation and supporting information provide data on the performance of an engineering-scale cross-flow heat exchanger used in hydrothermal liquefaction (HTL). Temperature profiles are provide for the process of waste water treatment sludges and a food waste. The data can be used to model larger-scale heat exchangers used in HTL.

Bioenergy Technologies Tags Heat Exchanger HTL MHT↗

SLUDGE WASHING AND DEMONSTRATION OF THE DWPF FLOWSHEET IN THE SRNL SHIELDED CELLS FOR SLUDGE BATCH 6 QUALIFICATION

Prior to initiating a new sludge batch in the Defense Waste Processing Facility (DWPF), Savannah River National Laboratory (SRNL) is required to simulate this processing, including Chemical Process Cell (CPC) simulation, waste glass fabrication, and chemical durability testing. This report documents this simulation for the next sludge batch, Sludge Batch 6 (SB6). SB6 consists of Tank 12 material that has been transferred to Tank 51 and subjected to Low Temperature Aluminum Dissolution (LTAD), Tank 4 sludge, and H-Canyon Pu solutions. Following LTAD and the Tank 4 addition, Liquid Waste Operations (LWO) provided SRNL a 3 L sample of Tank 51 sludge for SB6 qualification. Pu solution from H Canyon was also received. SB6 qualification included washing the sample per LWO plans/projections (including the addition of Pu from H Canyon), DWPF CPC simulations, waste glass fabrication (vitrification), and waste glass characterization and chemical durability evaluation. The following are significant observations from this demonstration. Sludge settling improved slightly as the sludge was washed. SRNL recommended (and the Tank Farm implemented) one less wash based on evaluations of Tank 40 heel projections and projections of the glass composition following transfer of Tank 51 to Tank 40. Thorium was detected in significant quantities (>0.1 wt % of total solids) in the sludge. In past sludge batches, thorium has been determined by Inductively Coupled Plasma-Mass Spectroscopy (ICP-MS), seen in small quantities, and reported with the radionuclides. As a result of the high thorium, SRNL-AD has added thorium to their suite of Inductively Coupled Plasma-Atomic Emission Spectroscopy (ICP-AES) elements. The acid stoichiometry for the DWPF Sludge Receipt and Adjustment Tank (SRAT) processing of 115%, or 1.3 mol acid per liter of SRAT receipt slurry, was adequate to accomplish some of the goals of SRAT processing: nitrite was destroyed to below 1,000 mg/kg and mercury was removed to below the DWPF target with 750 g of steam per g of mercury. However, rheological properties did not improve and were above the design basis. Hydrogen generation rates did not exceed DWPF limits during the SRAT and Slurry Mix Evaporator (SME) cycles. However, hydrogen generation during the SRAT cycle approached the DWPF limit. The glass fabricated with the Tank 51 SB6 SME product and Frit 418 was acceptable with respect to chemical durability as measured by the Product Consistency Test (PCT). The PCT response was also predictable by the current durability models of the DWPF Product Composition Control System (PCCS). It should be noted, however, that in the first attempt to make glass from the SME product, the contents of the fabrication crucible foamed over. This may be a result of the SME product's REDOX (Reduction/Oxidation - Fe{sup 2+}/{Sigma}Fe) of 0.08 (calculated from SME product analytical results). The following are recommendations drawn from this demonstration. In this demonstration, at the request of DWPF, SRNL caustic boiled the SRAT contents prior to acid addition to remove water (to increase solids concentration). During the nearly five hours of caustic boiling, 700 ppm of antifoam was required to control foaming. SRNL recommends that DWPF not caustic boil/concentrate SRAT receipt prior to acid addition until further studies can be performed to provide a better foaming control strategy or a new antifoam is developed for caustic boiling. Based on this set of runs and a recently completed demonstration with the SB6 Waste Acceptance Product Specifications (WAPS) sample, it is recommended that DWPF not add formic acid at the design addition rate of two gallons per minute for this sludge batch. A longer acid addition time appears to be helpful in allowing slower reaction of formic acid with the sludge and possibly decreases the chance of a foam over during acid addition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗