Recent SNAP Development
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Glaciers preserve climate variations in their geological and geomorphological records, which makes them prime candidates for climate reconstructions. Investigating the glacier–climate system over the past millennia is particularly relevant first because the amplitude and frequency of natural climate variability during the Holocene provides the climatic context against which modern, human-induced climate change must be assessed. Second, the transition from the last glacial to the current interglacial promises important insights into the climate system during warming, which is of particular interest with respect to ongoing climate change. Evidence of stable ice margin positions that record cooling during the past 12 kyr are preserved in two glaciated valleys of the Silvretta Massif in the eastern European Alps, the Jamtal (JAM) and the Laraintal (LAR). We mapped and dated moraines in these catchments including historical ridges using beryllium-10 surface exposure dating (10Be SED) techniques and correlate resulting moraine formation intervals with climate proxy records to evaluate the spatial and temporal scale of these cold phases. The new geochronologies indicate the formation of moraines during the early Holocene (EH), ca. 11.0 ± 0.7 ka (n = 19). Boulder ages along historical moraines (n = 6) suggest at least two glacier advances during the Little Ice Age (LIA; ca. 1250–1850 CE) around 1300 CE and in the second half of the 18th century. An earlier advance to the same position may have occurred around 500 CE. The Jamtal and Laraintal moraine chronologies provide evidence that millennial-scale EH warming was superimposed by centennial-scale cooling. The timing of EH moraine formation coincides with brief temperature drops identified in local and regional paleoproxy records, most prominently with the Preboreal Oscillation (PBO) and is consistent with moraine deposition in other catchments in the European Alps and in the Arctic region. This consistency points to cooling beyond the local scale and therefore a regional or even hemispheric climate driver. Freshwater input sourced from the Laurentide Ice Sheet (LIS), which changed circulation patterns in the North Atlantic, is a plausible explanation for EH cooling and moraine formation in the Nordic region and in Europe.
The authors give a brief account of some of their recent analytical and numerical studies of cone buckling. limiting the discussion to axisymmetric deformations. Pertinent numerical results for the relaxation buckling of full cones subjected to uniform external pressure and Belleville springs deformed by axial edge loads are presented. In addition. bifurcation buckling problems are discussed. For a specific case. the existence of Friedrichs' intermediate buckling load, P(m). as applied to cones. is established. Upper and lower bounds for its value are given.
Explore the source record for details and available documents.
Biological radiation exposure studies - large particle inhalation in dogs, intragastric and skin exposure in pigs, ingested particles in rats, and plutonium 28 ingestion rats
Irradiation testing of electronic components and subassemblies in Radiation Effects Reactor
Dynamic method of measuring output power characteristics of radioisotope thermoelectric generator
Nimbus 3/SNAP 19 radioisotopic thermoelectric generator design and performance
Explore the source record for details and available documents.
Computer program calculates normal vibration modes of complex structures elimating excessively large amounts of input data, run time, and core storage. Provision for accuracy improvement is also included.
The use of discrete ordinates and Monte Carlo techniques to solve radiation transport problems is discussed. A general discussion of two possible coupling schemes is given for the two methods. The calculation of the reactor radiation scattered from a docked service and command module is used as an example of coupling discrete ordinates (DOT) and Monte Carlo (MORSE) calculations.
The history of testing of compact tubular modules in flowing NaK loops is summarized. Test procedures, data handling, and instrument calibration are discussed. Also included is descriptive information of the test facilities, operational problems encountered, and some recommendations for testing.
The engineering, design, and fabrication status of the volume accumulator units to be employed in the NaK primary and secondary coolant loops of the 5-kwe reactor thermoelectric system are described. Three identical VAU's are required - two for the primary coolant loop, and one for the secondary coolant loop. The VAU's utilize nested-formed bellows as the flexing member, are hermetically sealed, provide double containment and utilize a combination of gas pressure force and bellows spring force to obtain the desired pressure regulation of the coolant loops. All parts of the VAU, except the NaK inlet tube, are to be fabricated from Inconel 718.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The Viking-75 mission environments and lander interface requirements which influence the design of the RTG (radioisotope thermoelectric generator), as well as RTG-related constraints are discussed. The baseline RTG design evolved from these considerations is presented with particular emphasis on the design features which make the Viking RTG unique. These features include a gas management system employing a separate gas reservoir to maintain the RTG hot junction and heat source temperatures within a desired range throughout the various mission phases, as well as a specially profiled housing/radiator assembly which facilitates both ground cooling of the RTGs prior to launch and thermal control of the lander after landing. Also presented is the expected RTG electrical performance when subjected to the various mission environments/requirements, such as 'power-up' operations in Mars orbit just prior to the entry, and thermal cycling on the Martian surface after landing.
Explore the source record for details and available documents.
Explore the source record for details and available documents.