Search NASA⌕ Search

SEARCH · Search NASA

Results for “software specification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Generalizable, fast, and accurate DeepQSPR with fastprop

Abstract Quantitative Structure–Property Relationship studies (QSPR), often referred to interchangeably as QSAR, seek to establish a mapping between molecular structure and an arbitrary target property. Historically this was done on a target-by-target basis with new descriptors being devised to specifically map to a given target. Today software packages exist that calculate thousands of these descriptors, enabling general modeling typically with classical and machine learning methods. Also present today are learned representation methods in which deep learning models generate a target-specific representation during training. The former requires less training data and offers improved speed and interpretability while the latter offers excellent generality, while the intersection of the two remains under-explored. This paper introduces , a software package and general Deep-QSPR framework that combines a cogent set of molecular descriptors with deep learning to achieve state-of-the-art performance on datasets ranging from tens to tens of thousands of molecules. provides both a user-friendly Command Line Interface and highly interoperable set of Python modules for the training and deployment of feedforward neural networks for property prediction. This approach yields improvements in speed and interpretability over existing methods while statistically equaling or exceeding their performance across most of the tested benchmarks. is designed with Research Software Engineering best practices and is free and open source, hosted at github.com/jacksonburns/fastprop.

Burns, Jackson W. (ORCID:0000000206579426)↗

Development of the ITER magnetic diagnostic set and specification

ITER magnetic diagnostics are now in their detailed design and R and D phase. They have passed their conceptual design reviews and a working diagnostic specification has been prepared aimed at the ITER project requirements. This paper highlights specific design progress, in particular, for the in-vessel coils, steady state sensors, saddle loops and divertor sensors. Key changes in the measurement specifications, and a working concept of software and electronics are also outlined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GlobiPack v. 1.0

GlobiPack contains a small collection of optimization globalization algorithms. These algorithms are used by optimization and various nonlinear equation solver algorithms.Used as the line-search procedure with Newton and Quasi-Newton optimization and nonlinear equation solver methods. These are standard published 1-D line search algorithms such as are described in the book Nocedal and Wright Numerical Optimization: 2nd edition, 2006. One set of algorithms were copied and refactored from the existing open-source Trilinos package MOOCHO where the linear search code is used to globalize SQP methods. This software is generic to any mathematical optimization problem where smooth derivatives exist. There is no specific connection or mention whatsoever to any specific application, period. You cannot find more general mathematical software.

Bartlett, Roscoe↗

GlobiPack v. 1.0

GlobiPack contains a small collection of optimization globalization algorithms. These algorithms are used by optimization and various nonlinear equation solver algorithms.Used as the line-search procedure with Newton and Quasi-Newton optimization and nonlinear equation solver methods. These are standard published 1-D line search algorithms such as are described in the book Nocedal and Wright Numerical Optimization: 2nd edition, 2006. One set of algorithms were copied and refactored from the existing open-source Trilinos package MOOCHO where the linear search code is used to globalize SQP methods. This software is generic to any mathematical optimization problem where smooth derivatives exist. There is no specific connection or mention whatsoever to any specific application, period. You cannot find more general mathematical software.

Bartlett, Roscoe↗

MACAW v1.0

The ability to embed molecules in a numeric space is essential in order to build mathematical and machine-learning models describing molecular properties or other processes affected by molecules. MACAW is a cheminformatic tool that allows embedding small molecules into a multidimensional numeric space. In the embedding, each molecule is assigned a numeric vector that captures information of the molecule in relation to other molecules, and that vector can be used as input to mathematical models. Molecules that are more similar to each other are embedded closer in this numeric space, whereas molecules that are more different are embedded further away. One advantage of the MACAW embedding technology compared to established alterantives is that it is fast and does not require extensive computational resources or expertise. In particular, MACAW embeddings can be used as input to mathematical models without the need for variable cleaning or feature selection, saving time and simplifying their use. On the other hand, MACAW also contains methods to generate new molecules and to recommend new molecules satisfying a desired molecular property. The generation of new molecules can be biased based on an input set of molecules, effectively generating molecular diversity around it. In its turn, MACAW's molecular recommendation tool is a novel method for evolving molecules in silico towards a desired molecular specification. In this method, the biased molecular generator tool is applied iteratively in combination with a molecular selection step. As a result, in each iteration the molecules selected by the software are increasingly closer to the desired specification. Both the molecular generation and the molecular recommendation tools are very fast, efficient, and intuitive to use.

Roger, VincentBlay↗

Simulation-based Testing of Control Software

It is impossible to adequately test complex software by examining its operation in a physical prototype of the system monitored. Adequate test coverage can require millions of test cases, and the cost of equipment prototypes combined with the real-time constraints of testing with them makes it infeasible to sample more than a small number of these tests. Model based testing seeks to avoid this problem by allowing for large numbers of relatively inexpensive virtual prototypes that operate in simulation time at a speed limited only by the available computing resources. In this report, we describe how a computer system emulator can be used as part of a model based testing environment; specifically, we show that a complete software stack including operating system and application software - can be deployed within a simulated environment, and that these simulations can proceed as fast as possible. To illustrate this approach to model based testing, we describe how it is being used to test several building control systems that act to coordinate air conditioning loads for the purpose of reducing peak demand. These tests involve the use of ADEVS (A Discrete Event System Simulator) and QEMU (Quick Emulator) to host the operational software within the simulation, and a building model developed with the MODELICA programming language using Buildings Library and packaged as an FMU (Functional Mock-up Unit) that serves as the virtual test environment.

97 MATHEMATICS AND COMPUTING↗

Test facility for fission chamber assemblies - 239

The Institution -Project Center ITER- with participation of the National Research Nuclear University MEPhI are developing the neutron diagnostics -Divertor Neutron Flux Monitor- (DNFM) for the International Thermonuclear Experimental Reactor (ITER). This diagnostics shall ensure measurement of the total neutron yield and ITER fusion power. Assemblies of fission chambers (FC) with different fissile materials and sensitivities are planned to be used for the neutron flux measurement. Study of fission chambers characteristics and acceptance testing of the diagnostic system will be carried out at the testing facility of the neutronic laboratory of the 'TRINITI' Institute. The facility includes: compact powerful neutron generator with the power, control and monitoring system; remote handling system for FCs positioning and movement; novel three channels data acquisition and processing system. Each acquisition channel contains some measuring circuits with signal processing. This set of circuits provides neutron flux measurement in the range of at least 10 decades for each single FC. Data acquisition and processing system features are: signal digitizing with sample rate up to 125 MHz; real time data processing with computation and data update cycle from 0.1 ms. This paper examines the structure, composition and specification of the test facility. Application software, hardware solutions and the results of fission chambers prototypes tests are discussed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-E-BRE-05: Analysis of Dosimetric Characteristics in Two Leaf Motion Calculator Algorithms for Sliding Window IMRT

Purpose: The Smart leaf motion calculator (SLMC) in Eclipse treatment planning system is an advanced fluence delivery modeling algorithm as it takes into account fine MLC features including inter-leaf leakage, rounded leaf tips, non-uniform leaf thickness, and the spindle cavity etc. In this study, SLMC and traditional Varian LMC (VLMC) algorithms were investigated, for the first time, in dosimetric characteristics and delivery accuracy of sliding window (SW) IMRT. Methods: The SW IMRT plans of 51 cancer cases were included to evaluate dosimetric characteristics and dose delivery accuracy from leaf motion calculated by SLMC and VLMC, respectively. All plans were delivered using a Varian TrueBeam Linac. The DVH and MUs of the plans were analyzed. Three patient specific QA tools - independent dose calculation software IMSure, Delta4 phantom, and EPID portal dosimetry were also used to measure the delivered dose distribution. Results: Significant differences in the MUs were observed between the two LMCs (p≤0.001).Gamma analysis shows an excellent agreement between the planned dose distribution calculated by both LMC algorithms and delivered dose distribution measured by three QA tools in all plans at 3%/3 mm, leading to a mean pass rate exceeding 97%. The mean fraction of pixels with gamma < 1 of SLMC is slightly lower than that of VLMC in the IMSure and Delta4 results, but higher in portal dosimetry (the highest spatial resolution), especially in complex cases such as nasopharynx. Conclusion: The study suggests that the two LMCs generates the similar target coverage and sparing patterns of critical structures. However, SLMC is modestly more accurate than VLMC in modeling advanced MLC features, which may lead to a more accurate dose delivery in SW IMRT. Current clinical QA tools might not be specific enough to differentiate the dosimetric discrepancies at the millimeter level calculated by these two LMC algorithms. NIH/NIGMS grant U54 GM104944, Lincy Endowed Assistant Professorship.

60 APPLIED LIFE SCIENCES↗

ExaTENSOR

ExaTENSOR is a software math library for performing basic numerical tensor algebra operations on distributed heterogeneous HPC platforms. The library provides the following basic numerical tensor algebra primitives: tensor contraction, tensor product, tensor addition, tensor scaling by a scalar, etc. ExaTENSOR supports dense, block-sparse and hierarchical block-sparse tensors stored and processed across many heterogeneous HPC nodes (node equipped with NVIDIA GPU and Intel Xeon Phi have been considered so far). The architecture of ExaTENSOR is based on the concept of domain-specific virtual processor (DSVP), that is, an intermediate software layer capable of processing domain-specific instructions, in this case, numerical tensor algebra instructions. In this way, a separation of the domain-specific algorithm expression and hardware-agnostic algorithm execution is achieved, thus ensuring portability of the applications which use ExaTENSOR as a numerical backend.

Liakh, Dmytro↗

Wcomp (Wind Farm Wake Comparison Framework) [SWR-23-72]

The Wind Farm Wake Comparison Framework (Wcomp) is a software tool to facilitate the comparison of a specific collection of wind farm wake modeling tools: Python-based, steady-state, analytical wake modeling utilities. Wcomp integrates another software project, windIO, to create a consistent method for describing a wind farm flow control problem. Additionally, a data structure is included to represent the outputs a wind farm flow control simulation. Well-described interfaces allow existing wake modeling tools to plug into this framework.

Mudafort, Rafael↗

Preliminary Radioisotope Screening for Off-site Consequence Assessment of Advanced Non-LWR Systems

Currently a set of 71 radionuclides are accounted for in off-site consequence analysis for LWRs. Radionuclides of dose consequence are expected to change for non-LWRs, with radionuclides of interest being type-specific. This document identifies an expanded set of radionuclides that may need to be accounted for in multiple non-LWR systems: high temperature gas reactors (HTGRs); fluoride-salt-cooled high-temperature reactors (FHRs); thermal-spectrum fluoride-based molten salt reactors (MSRs); fast-spectrum chloride-based MSRs; and, liquid metal fast reactors with metallic fuel (LMRs) Specific considerations are provided for each reactor type in Chapter 2 through Chapter 5, and a summary of all recommendations is provided in Chapter 6. All identified radionuclides are already incorporated within the MACCS software, yet the development of tritium-specific and carbon-specific chemistry models are recommended.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Argonne Reactor Code Software Verification and Validation Plan for the Versatile Test Reactor

This Argonne Reactor Code (ARC) software has taken a pivotal role in the design work of the Versatile Test Reactor. The ARC software itself consists of several independent or semiindependent pieces of software that are used in concert to carry out specific analysis and design objectives. In this report, we discuss the validation that is needed for the ARC software overall and discuss available, usable experimental data and how it relates to the VTR project. We also discuss the verification that is required for the ARC software with respect to its usage in the VTR project and give some concrete examples as to what it must accomplish. A list of goals for the verification and validation work are presented as the general procedure that will be implemented for every individual piece of software in ARC. The ARC software has been continuously developed for over 50 years and many of the features used for the VTR project have thus been rigorously tested for accuracy during that timeframe. The ARC software is presently under source code control and undergoes nightly regression testing of not only the individual pieces, but the interconnected aspects that are common to most analysis projects. Its greatest weakness, from a software verification and validation perspective, is both a lack of documentation and outdated documentation. As an example, much of the previous validation work will require contemporary effort to re-evaluate given the updated base data libraries and modifications to the software that have occurred since. This requires new documentation to be produced to support the usage of the software in the VTR project. The bulk of the ARC software is focused on steady state neutronics and TH behavior of a reactor system. In this regard, we have identified the ZPPR, FFTF, and EBR-II programs as the best candidates for sources of validation data for the VTR project. The ZPPR-15 series in the ZPPR program was chosen as it is the best representation of the VTR fuel form and reactor core layout of all of the ZPPR measurements. Additional support for it comes from the fact that most of the data has already been processed into usable ARC models for VTR validation. The FFTF and EBR-II reactors were both functional reactors that provide reactor scale measurements. FFTF is clearly a closer match to VTR and its startup measurements would be a very valuable validation basis. EBR-II has invaluable burnup related measurements that will play a key role in the ARC software validation work. Each piece of ARC software will require a report detailing the software verification. The validation work will be logically split into the results of modeling each identified experimental resource (ZPPR, EBR-II, FFTF). The intended timeline for the VTR project is to have the ARC software verified and validated by the end of fiscal year 2020. This is incumbent on sufficient funding allocated to V&V activities and no change in programmatic priorities.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Statistical Mechanics on Lattices (smol) v0.0.1

smol is a Python implementation of the Cluster Expansion Method and extensions of this methodology; which is used to fit applied lattice models from first principle calculations for subsequent use in Monte Carlo simulations for computing thermodynamic and statistical properties of atomic configuration. smol has a several notable advantages over other similar software packages. The first being its Python implementation which makes it easy to use even for users with little software and coding skills. Despite being implemented in Python, essential Monte Carlo routines are implemented in Cython such that performance is not compromised and is competitive even to similar software implemented in C/C++. Furthermore, the package has specific functionality for handling complex ionic materials (such as cathodes and electrolytes) that is not readily available in other packages. Lastly, the software has a flexible and modular design with the intention of making it fast and efficient to develop and extend the methodology.

Barroso-Luque, Luis↗

PeakWorks

The PeakWorks software is designed to assist in the quantitative analysis of atom probe tomography (APT) generated mass spectra. Specifically, through an interactive user interface, mass peaks can be identified automatically (defined by a threshold) and/or identified manually. The software then provides a means to assign specific elemental isotopes (including more than one) to each peak. The software also provides a means for the user to choose background subtraction of each peak based on background fitting functions, the choice of which is left to the users discretion. Peak ranging (the mass range over which peaks are integrated) is also automated allowing the user to chose a quantitative range (e.g. full-widthhalf- maximum). The software then integrates all identified peaks, providing a background-subtracted composition, which also includes the deconvolution of peaks (i.e. those peaks that happen to have overlapping isotopic masses). The software is also able to output a 'range file' that can be used in other software packages, such as within IVAS. A range file lists the peak identities, the mass range of each identified peak, and a color code for the peak. The software is also able to generate 'dummy' peak ranges within an outputted range file that can be used within IVAS to provide a means for background subtracted proximity histogram analysis.

Source record↗

Genome-Scale 13 C Fluxomics Modeling for Metabolic Engineering of Saccharomyces cerevisiae .

Synthetic biology is a rapidly developing field that pursues the application of engineering principles and development approaches to biological engineering. Synthetic biology is poised to change the way biology is practiced, and has important practical applications: for example, building genetically engineered organisms to produce biofuels, medicines, and other chemicals. Traditionally, synthetic biology has focused on manipulating a few genes (e.g., in a single pathway or genetic circuit), but its combination with systems biology holds the promise of creating new cellular architectures and constructing complex biological systems from the ground up. Enabling this merge of synthetic and systems biology will require greater predictive capability for modeling the behavior of cellular systems, and more comprehensive data sets for building and calibrating these models. The so-called "-omics" data sets can now be generated via high throughput techniques in the form of genomic, proteomic, transcriptomic, and metabolomic information on the engineered biological system. Of particular interest with respect to the engineering of microbes capable of producing biofuels and other chemicals economically and at scale are metabolomic datasets, and their insights into intracellular metabolic fluxes. Metabolic fluxes provide a rapid and easy to understand picture of how carbon and energy flow throughout the cell. Furthermore, we present a detailed guide to performing metabolic flux analysis and modeling using the open source JBEI Quantitative Metabolic Modeling (jQMM) library. This library allows the user to transform metabolomics data in the form of isotope labeling data from a 13 C labeling experiment into a determination of cellular fluxes that can be used to develop genetic engineering strategies for metabolic engineering.The jQMM library presents a complete toolbox for performing a range of different tasks of interest in metabolic engineering. Various different types of flux analysis and modeling can be performed such as flux balance analysis, 13 C metabolic flux analysis, and two-scale 13 C metabolic flux analysis (2S- 13 C MFA). 2S- 13 C MFA is a novel method that determines genome-scale fluxes without the need of every single carbon transition in the metabolic network. In addition to several other capabilities, the jQMM library can make model based predictions for how various genetic engineering strategies can be incorporated toward bioengineering goals: it can predict the effects of reaction knockouts on metabolism using both the MoMA and ROOM methodologies. In this chapter, we will illustrate the use of the jQMM library through a step-by-step demonstration of flux determination and knockout prediction in a complex eukaryotic model organism: Saccharomyces cerevisiae ( S. cerevisiae ). Included with this chapter is a digital Jupyter Notebook file that provides a computable appendix showing a self-contained example of jQMM usage, which can be changed to fit the user's specific needs. As an open source software project, users can modify and extend the code base to make improvements at will, allowing them to share their development work and contribute back to the jQMM modeling community.

-Omics data↗

Sphere-Enhanced Microwave Ablation (sMWA) Versus Bland Microwave Ablation (bMWA): Technical Parameters, Specific CT 3D Rendering and Histopathology

PurposeThis study was designed to compare technical parameters during ablation as well as CT 3D rendering and histopathology of the ablation zone between sphere-enhanced microwave ablation (sMWA) and bland microwave ablation (bMWA).MethodsIn six sheep-livers, 18 microwave ablations were performed with identical system presets (power output: 80 W, ablation time: 120 s). In three sheep, transarterial embolisation (TAE) was performed immediately before microwave ablation using spheres (diameter: 40 ± 10 μm) (sMWA). In the other three sheep, microwave ablation was performed without spheres embolisation (bMWA). Contrast-enhanced CT, sacrifice, and liver harvest followed immediately after microwave ablation. Study goals included technical parameters during ablation (resulting power output, ablation time), geometry of the ablation zone applying specific CT 3D rendering with a software prototype (short axis of the ablation zone, volume of the largest aligned ablation sphere within the ablation zone), and histopathology (hematoxylin-eosin, Masson Goldner and TUNEL).ResultsResulting power output/ablation times were 78.7 ± 1.0 W/120 ± 0.0 s for bMWA and 78.4 ± 1.0 W/120 ± 0.0 s for sMWA (n.s., respectively). Short axis/volume were 23.7 ± 3.7 mm/7.0 ± 2.4 cm{sup 3} for bMWA and 29.1 ± 3.4 mm/11.5 ± 3.9 cm{sup 3} for sMWA (P < 0.01, respectively). Histopathology confirmed the signs of coagulation necrosis as well as early and irreversible cell death for bMWA and sMWA. For sMWA, spheres were detected within, at the rim, and outside of the ablation zone without conspicuous features.ConclusionsSpecific CT 3D rendering identifies a larger ablation zone for sMWA compared with bMWA. The histopathological signs and the detectable amount of cell death are comparable for both groups. When comparing sMWA with bMWA, TAE has no effect on the technical parameters during ablation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗