Search NASA⌕ Search

SEARCH · Search NASA

Results for “solar cycle 25”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Odyssey Mars Orbiter - Thirteen Years of On-Orbit Navigation

The Odyssey spacecraft has been in Mars orbit since October 24, 2001 and has nearly completed 61,490 orbits. Navigation operational objectives include the following: Control the local mean solar time for science observations; for most of the mission, this varied from 3:45 pm to 5:20 pm. Currently, an orbit trim maneuver planned for November 10, 2015 will place Odyssey at 6:45 pm/6:45 am at equator crossings in order to observe early morning ground frost, fog and clouds. Initially, Odyssey was late by 42 minutes for an over-flight of the critical seven minutes of Phoenix's entry, descent and landing (EDL). Odyssey was successfully positioned for this over-flight using the Delta V from angular momentum desaturations (AMD). Similar results for the Mars Science Laboratory's EDL and Comet Siding Spring's minimum risk location will be presented. Odyssey has and continues to relay significant quantities of rover data. Navigation successfully models frequent AMD Delta Vs in order to generate accurate sixty-day trajectory predictions; a typical timing error is 25 seconds after 60 days. However, unexpected events, such as safe-mode entries with their larger and more frequent thrusting, severely impact that trajectory accuracy. Impacted trajectories can have timing errors ranging from a few minutes to ten-to-fifteen minutes after sixty-days. Other analyses (briefly stated) include: a) the offset of the orbital ground track pattern after an initial cycle of 30 days or 362 orbits and b) an operations environment of continuous thrusting if/when one of the three remaining reaction wheels fails.

trajectory accuracy↗

Lightweight, Self-Deploying Foam Antenna Structures

Lightweight, deployable antennas for a variety of outer-space and terrestrial applications would be designed and fabricated according to the concept of cold hibernated elastic memory (CHEM) structures, according to a proposal. Mechanically deployable antennas now in use are heavy, complex, and unreliable, and they utilize packaging volume inefficiently. The proposed CHEM antenna structures would be simple and would deploy themselves without need for any mechanisms and, therefore, would be more reliable. The proposed CHEM antenna structures would also weigh less, could be packaged in smaller volumes, and would cost less, relative to mechanically deployable antennas. The CHEM concept was described in two prior NASA Tech Briefs articles: "Cold Hibernated Elastic Memory (CHEM) Expandable Structures" (NPO-20394), Vol. 23, No. 2 (February 1999), page 56; and "Solar Heating for Deployment of Foam Structures" (NPO-20961), Vol. 25, No. 10 (October 2001), page 36. To recapitulate from the cited prior articles: The CHEM concept is one of utilizing opencell foams of shape-memory polymers (SMPs) to make lightweight, reliable, simple, and inexpensive structures that can be alternately (1) compressed and stowed compactly or (2) expanded, then rigidified for use. A CHEM structure is fabricated at full size from a block of SMP foam in its glassy state [at a temperature below the glass-transition temperature (Tg) of the SMP]. The structure is heated to the rubbery state of the SMP (that is, to a temperature above Tg) and compacted to a small volume. After compaction, the structure is cooled to the glassy state of the SMP. The compacting force can then be released and the structure remains compact as long as the temperature is kept below Tg. Upon subsequent heating of the structure above Tg, the simultaneous elastic recovery of the foam and its shape-memory effect cause the structure to expand to its original size and shape. Once thus deployed, the structure can be rigidified by cooling below Tg. Once deployed and rigidified, the structure could be heated and recompacted. In principle, there should be no limit on the achievable number of compaction/deployment/ rigidification cycles. Thus far, several different designs of a 3.5-m-long CHEM conical corrugated horn antenna have been analyzed (see figure). A small CHEM structural antenna model was fabricated and a thin, electrically conductive layer of aluminum was deposited on the inner surface of the model. This structural model was then subjected to the compaction and deployment treatments described above to demonstrate the feasibility of a CHEM corrugated horn antenna.

Sokolowski, Witold↗

Influence of Linker Group on Bipolar Redox-Active Molecule Performance in Non-Aqueous Redox Flow Batteries

Redox flow batteries (RFBs) are an attractive choice for stationary energy storage of renewables such as solar and wind. Non-aqueous redox flow batteries (NARFBs) have garnered broad interest due to their high voltage operation compared to their aqueous counterparts. Further, the utilization of bipolar redox-active molecules (BRMs) is a practical way to alleviate crossover faced by asymmetric RFBs. In this work, ferrocene (Fc) and phthalimide (PI) are covalently linked with various tethering groups which vary in structure and length. The compiled results suggest that the length and steric shielding ability of the linker group can greatly influence the stability and overall performance of Fc-n-PI BRM-based NARFBs. Primary sources of capacity loss are found to be BRM degradation for straight chain spacers <6 carbons and membrane (Nafion) fouling. Fc-hexyl-PI provided the most stable battery cycling and coulombic efficiencies of >98 % over 100 cycles (~13 days). NARFB using Fc-hexyl-PI as an active material exhibited high working voltage (1.93 V) and maximum capacity (1.28 Ah L -1 ). Additionally, this work highlights rational strategies to improve cycling stability and optimize NARFB performance.

25 ENERGY STORAGE↗

Lifespan Impacts to Infrastructure, Renewable Energy Components and Energy Storage Components Related to Fluoropolymer Use

This report focuses on the use of fluoropolymers in infrastructure materials (building construction materials, transportation, and electrical transmission and distribution); renewable energy generation components (specifically wind and solar); and energy storage components (lithium-ion batteries and fuel cells) and product lifespan impacts if fluoropolymers were no longer available or allowed in commerce. Additionally, environmental considerations for fluoropolymer manufacture, use, and end-of-life disposal are discussed. This document is the second of two companion reports. The first report, Assessment of Fluoropolymer Production and Use With Analysis of Alternative Replacement Materials, contained an analysis of use of fluoropolymers and their potential replacement technologies in aerospace, automotive, battery, building construction, chemical processing, electronics, infrastructure, semiconductor, solar panel, and wind energy industries sectors, along with qualitative life cycle assessment (LCA) and cost-benefit analysis of replacing fluoropolymers. This report does not focus on the lifecycle aspects of use of fluoropolymer or alternatives in the designated applications. For more information on those topics, see aforementioned report.

25 ENERGY STORAGE↗

Solar +: Clean Energy Strategies for the Sunshine State (Final Technical Report (FTR) of the Florida Alliance for Accelerating Solar and Storage Technology Readiness (FAASSTeR))

This reports on a four-year effort to provide foundational research, analysis, strategies and assistance to help Florida, and other states that might learn from this work, to grow solar energy in conjunction with other distributed energy resources by addressing and overcoming existing barriers, and in way that delivers increased value. The start of this effort coincided with an inflection point of sorts into a new dawn for solar energy in Florida, where the Sunshine state’s national ranking in total installed solar, according to the Solar Energy Industries Association (SEIA), has rose from 13th to 4th. Florida has now become the national leader in annual utility-scale solar growth as dozens of large plants have come online. Also, during this time, Florida utilities have expressed a strong and growing interest in understanding the role of energy storage and how to best plan for and deploy this unique resource as part of strategies to grow solar. The utility-scale solar growth experienced has been fueled by the economics of solar cost-parity with natural gas combined cycle plants and Florida Public Service Commission’s (PSC) approval of cost-recovery for the Investor-Owned Utilities (IOU’s), primarily through the Solar Base Rate Adjustment (SoBRA) mechanism. This has led to gigawatts (GW’s) of rate-based solar capacity additions over several years, along with fairly significant amounts of energy storage. Meanwhile, municipal electric utilities, which, collectively, are the third largest source of power in the state, have been increasing solar considerably through power purchase agreements (PPA’s) and are on track to have close to 1 GW of grid-connected solar by 2024. Florida’s municipal utilities and the Florida Municipal Electric Association (FMEA) have been key partners in the Florida Alliance for Accelerating Solar and Storage Technology Readiness (FAASSTeR), formed to carry out this effort. The six largest of these have been Core Team utilities, engaging throughout the project in weekly calls, discussions, and project direction, participating in and hosting workshops and benefiting from technical assistance in several areas.

14 SOLAR ENERGY↗

A Stable and Ultrafast Control for Multiparallel Grid-Tied SiC Inverters With LVRT Capability Considering Cable Impedance

The stability of multiparalleled grid-tied inverters remains a challenging issue especially during low-voltage ride-through (LVRT) in the presence of grid impedance. SiC device-based grid-tied inverters can achieve advantages such as higher efficiency, reduced size of interface filters, and fast dynamics; however, they can exacerbate this stability issue particularly when LVRT occurs along with high inrush current due to their low inertia characteristics. In this article, a direct deadbeat control method without any PI control loop is proposed for multiparallel grid-tied SiC inverters. The proposed control achieves instantaneous current regulations within switching cycles. In addition, it mitigates high inrush currents and maintains stability during LVRT transients without requiring mode transitions between normal and LVRT operation modes, thereby achieving an ultrafast response and seamless operation through this unified control method. The Lyapunov method is applied to analyze the multiparallel inverter stability in the presence of grid impedance with proposed deadbeat control method. The inverter V-I trajectories during LVRT transients are derived to illustrate the ultrafast and stable feature of proposed control. Finally, the experimental results of two grid-tied SiC inverters operating at LVRT transients are provided to verify the advantages of the proposed control method.

14 SOLAR ENERGY↗

A Comparative Analysis of Lithium-Ion Battery Chemistries for Cold-Climate Maritime Applications

Energy storage, primarily in the form of electrochemical batteries, is critical for enabling integration of marine energy (e.g., power from waves and currents) with end-use applications at sea due to the periodicity of the resources and requirement of consistent, smooth power delivery. Powering high-latitude coastal or ocean-based observing systems has been identified as a high value-proposition use case, exemplifying the concept of Powering the Blue Economy. An existing power system implementation for such a platform uses solar panels coupled to rechargeable lithium-ion batteries, augmented by a non-rechargeable backup bank used to power heaters in winter months. As wave energy is a potential resource for powering this and similar use cases and is strongest when solar power is most limited, it was hypothesized that integration of wave power would alleviate some of the challenges in cold climates related to energy storage. In this work, we investigate the use case scenario in simulation and perform a comparative test of commercially-available lithium-ion battery chemistry formulations to determine the most appropriate choice for the application. The experiment compared the most commonly-used lithium-based battery types (NCM, NCA, and LFP) in laboratory conditions emulating a battery enclosure thermally coupled to freezing seawater using an industrial battery performance tester in PNNL's arctic simulation lab. Battery strings were repeatedly cycled (i.e., charged, discharged, rested) and their usable capacity was measured. Both NCM and NCA strings exhibited degradation upon cycling, while the LFP string maintained stable operation through over 700 complete cycles. Though lower in baseline capacity, LFP are recommended for this and similar low-temperature applications with access to high levels of bulk charging current (e.g., from high-energy wave events) and their use may reduce the cost and complexity of battery conditioning and protection apparatus.

16 TIDAL AND WAVE POWER↗

Pilot Development Progress to Demonstrate Electric Thermal Energy Storage (ETES) Using Low-Cost Particles

The rapid growth of future energy demand increases the need to economically store electrical energy over durations up to several days in long-duration energy storage (LDES) applications. LDES can reduce the grid stress for improving the resilience of the grid. The integration of renewable power and storage has several significant and positive impacts including expanding the renewable energy portion of electricity generation, meeting peak-load demand, and coordinating supply and demand. Several energy storage approaches including mechanical, chemical and electrochemical methods are currently deployed or under development. However, LDES requirements pose unique challenges for scalability, energy capacity, and cost. Thermal energy storage (TES) has the ability to store a large capacity of energy with improved site flexibility compared to incumbent LDES technologies (i.e., pumped hydro) and has attracted significant interest. Our development in TES technology using solid particles as the storage medium has shown feasibility and potential in serving LDES purposes. Particle TES has various advantages over commercialized molten nitrate salt TES and has emerged as a promising storage technology originating from Generation 3 concentrating solar power (CSP) development. Stable, inexpensive silica sand produced in the Midwestern U.S. was identified as a suitable storage medium and has been validated through lab heating and cycling tests. We have successfully developed particle TES for bidirectional electric energy storage to broaden the applications for TES beyond CSP technologies and into standalone electric-thermal energy storage (ETES) systems. Key component designs and performance were verified with prototype testing and model simulations. The ETES system uses high-temperature, low-cost particle thermal energy storage coupled with a unique pressurized fluidized bed heat exchanger that supports a high-efficiency, air-Brayton combined power cycle. At times of low energy demand or high renewable production, an electric particle heater heats large quantities of solid particles to high temperatures in excess of 1100 degrees C. The particles are stored in internally insulated silos. At times of high electricity demand, the hot particles are gravity-fed through the heat exchanger where stored thermal energy is transferred to the power cycle working fluid to drive the gas turbine power generation system, thereby converting the thermal energy back into electricity for the grid. The cold particles leaving the heat exchanger are returned to the storage silos by a well-insulated particle conveyor. This ETES technology using particle TES can be sited anywhere and is predicted to be economic and efficient. Moreover, this ETES technology could be co-located with a retired coal or gas plant to leverage existing power generation and grid infrastructure. Our work has focused on the development of each of the key components (e.g., the electric particle heater, particle storage silos, and the particle-to-gas pressurized fluidized bed heat exchanger) through conceptual designs, prototype testing, and computational modeling. These developments demonstrate technological feasibility and are an important step towards the next phase of development of this promising LDES technology. This presentation will show the progress in developing a pilot demonstration of the ETES system on a commercially relevant scale.

25 ENERGY STORAGE↗

Selective Thermal Emission with Radiation and Adsorption in Annuli (STERADIAN): An Advanced Heat Exchanger Concept for Supercritical CO 2 Power Cycles

One of the key limitations affecting ability to achieve the efficiency and cost saving advantages of a supercritical CO 2 (scCO 2 ) power cycle resides with the primary heat exchanger where costs can exceed 50% of the plant capital budget depending on design. This project established the foundational groundwork for a new type of heat exchanger optimized to take advantage of radiative heat transfer to scCO 2 . Selective thermal emission coatings were designed and tested that radiated more light tuned to the 4.2 µm infrared absorption band of CO 2 . Coating design utilized principles of nanophotonic bandgap theory to design a selective emitter that has: 1) low emissivity in the visible band, 2) near 100% effective emissivity in the mid-IR wavelength between 4 and 4.5 µm wavelength, and 3) strong suppression of far-IR light emission that will maximize radiative heat transfer efficiency to scCO 2 . Computational fluid dynamics simulations show that an advanced heat exchanger implementing this selective thermal emitter coating is 25 to as much as 40% smaller than conventional heat exchanger designs.

14 SOLAR ENERGY↗

TRMM Fire Algorithm, Product and Applications

Land fires are frequent menaces to human lives and property. They also change the state of the vegetation and contribute to the climate forcing by releasing large amount of aerosols and greenhouse gases into the atmosphere. This paper summarizes methodologies of detecting global land fires from the Tropical Rainfall Measuring Mission (TRMM) Visible Infrared Scanner FIRS) measurements. The TRMM Science Data and Information System (TSDIS) fire products include global images of daily hot spots and monthly fire counts at 0.5 deg. x 0.5 deg. resolution, as well as text fiies that details necessary information of all fire pixels. The information includes date, orbit number, pixel number, local time, solar zenith angle, latitude, longitude, reflectance of visible/near infrared channels, brightness temperatures of infrared channels, as well as background brightness temperatures of infrared channels. These products have been archived since January 1998. The TSDIS fire products are compared with the coincidental European Commission (EC) Joint Research Center (JRC) 1 km AVHRR fire products. Analyses of the TSDIS monthly fire products during the period from 1998 to 2003 manifested seasonal cycles of biomass fires over Southeast Asia, Africa, North America and South America. The data also showed interannual variations associated with the 98/99 ENS0 cycle in Central America and the Indonesian region. In order to understand the variability of global land fires and their effects on the distribution of atmospheric aerosols, statistical methods were applied to the TSDIS fire products as well as to the Total Ozone Mapping Spectrometer (TOMS) aerosol index products for a period of five years from January 1998 to December 2002. The variability of global atmospheric aerosol is consistent with the fire variations over these regions during this period. The correlation between fire count and TOMS aerosol index is about 0.55 for fire pixels in Southeast Asia, Indonesia, and Africa. Parallel statistical analyses such as Empirical Orthogonal Function (EOF) analysis and Singular Spectrum Analysis (SSA) methods were applied to pentad TRMM fire data and TOMS aerosol data. The EOF analyses showed contrast between North and South hemispheres and also inter- continental transitions in Africa and America. EOF and SSA analyses also identified 25-60 day intra-seasonal oscillations that were superimposed on the annual cycles of both fire and aerosol data. The intra-seasonal variability of fires showed similarity of tropical rainfall oscillation modes. The TRMM fire products were also compared to the coincident TRMh4 rainfall and other rainfall products to investigate the interaction between rainfall and fire. The results indicate that the annual, interannual and intraseasonal variability of fire are dominated by global rainfall variations. However, the feedback of fire to the rainfall occurrence at regional scale for certain regions is also evident.

Ji, Yi-Min↗

Failure Analysis for Molten Salt Thermal Energy Storage Tanks for In-Service CSP Plants

Thermal Energy Storage (TES) is a fundamental component in concentrating solar power (CSP) plants to increase the plant's dispatchability, capacity factor, while reducing the levelized cost of electricity. In central receivers CSP plants, nitrate molten salts have been used for several years for operation temperatures of up to 565 degrees C. Despite many efforts to advance nitrate salt to higher operation temperatures (even considering a replacement with molten chloride salts) to achieve higher energy conversion efficiencies, the 565 degrees C temperature is currently considered the state-of-the art. Although molten salt tanks have been broadly deployed in commercial CSP plants worldwide, several failures have been reported in these tanks after a few months or years of operation, causing significant economic loss and mistrust in CSP technologies. Most of these failures are associated with the infancy of the technology and multiple issues related to tank design, fabrication, commissioning, and aggressive operation. A technical standard dedicated to the design and fabrication of molten nitrate TES tanks does not exist today. Current in-service molten salt tanks have been generally designed based on the American Petroleum Institute's (API) 650 and ASME Section II standards. The API 650 code provides guidelines for dimensions and fabrication for oil storage tanks up to 260 degrees C. The ASME standard provides allowable stress values for various materials at a range of temperatures and conditions. Both standards seem to be limited for molten salt TES tanks where high temperatures, thermal cycling, and transient conditions are expected. In 2020, NREL released the Concentrating Solar Power Best Practices Study (NREL/TP-5500-75763) that summarized multiple issues in CSP plants, along with potential alternatives and recommendations to address those issues based on information collected from participants representing about 80% of operating CSP plants in the world. One of the recommendations from this study was the development of accurate and validated models to evaluate the plant's transient operation, capable of capturing the effect of short-term clouds and operator response, while being flexible in being adapted to various spatial and temporal resource data. The "Failure Analysis for Molten Salt Thermal Energy Tanks for In-Service CSP Plants" project was inspired on this recommendation and was focused on (1) the development and validation of a physics-based model for a representative, commercial-scale molten salt tank, (2) performing simulations to evaluate the behavior of the tank as a function of typical plant operation conditions, (3) understanding tank failures mechanisms, (4) determining the residual stress and distortion in the tank floor after welding fabrication and evaluating their impact in the stresses developed in the tank during operation, (5) assessing the impact of key operation parameters on the temperature and stress distribution, (6) conduct a preliminary evaluation of design features to reduce stress and improve tank's reliability, and (7) estimate the tank's service life based on the stress developed under diverse operation scenarios. From the analysis conducted in the project and presented in this report, it was found that maximum stresses surpassing the yield strength point of the stainless steel (SS) 347H are developed on the tank floor near the perimeter. These large stresses are strongly influenced by the initial residual stresses and distortion of the tank floor after welding fabrication. During operation, large stresses are developed in the tank floor at high operation temperatures with large salt inventory levels during transient operation. High stresses are also related to elevated temperature gradients in the tank floor that could be attributed to insufficient mixing within the salt inflow and the salt inventory. Based on the analysis, creep is the predominant failure mechanism. However, the large stress levels could favor the plastic deformation into buckles, and crack formation due to stress relaxation cracking during cycle operation. A lifetime below 3 years was estimated for the typical plant operation conditions and a specific initial residual stress and deformation distribution of the tank floor. The estimated life agrees with the service time to failure reported in several commercial molten salt tanks. Desing and operation guidelines can be extracted from the analysis presented in this report, which could be adopted by tank manufacturers and CSP operators to advance toward an ultimate solution for tank failures by reducing residual and operational stresses to achieve a tank service life of more than 30 years. Addressing failures in molten salt TES tanks is fundamental for the CSP industry's survivability, but it is also important for other industrial and power generation applications using this technology, including nuclear and concentrating solar thermal.

14 SOLAR ENERGY↗

DC-Link Current Minimization Control for Current Source Converter-Based Solid-State Transformer

This article proposes a fast predictive control method and a small DC-link inductor to minimize the DC-link current in current-source converter (CSC)-based solid-state transformer. The DC-link current minimization can significantly reduce power loss and improve efficiency. The challenge of this problem is on improving both steady-state and dynamic performance. PI control methods and large DC-link inductors are conventionally used in the CSC but have limited dynamic performance. A model predictive control (MPC) method is proposed to achieve switching-cycle-level settling time, and the DC-link inductor is sized for 40% ripple to enable fast current change. Importantly, this article also proposes to minimize the DC-link current by varying the current even within a line cycle under single-phase load to improve the steady-state performance, in contrast with the reduction to a constant value in the literature. The proposed MPC features a constant switching frequency without weighting factors. The MPC does not have a high computational burden and is implemented in a regular digital controller for a prototype of soft-switching solid-state transformer (S4T) with reduced conduction loss. The effectiveness of the proposed method has been experimentally verified on the SiC S4T prototype during steady-state and dynamics under different multiport power flow conditions up to 2 kV peak. Here, the DC-link current in the experiments is close to the minimum current with a short zero-vector duration, which further verifies the performance of the proposed method.

14 SOLAR ENERGY↗

Cathode regeneration and upcycling of spent LIBs: toward sustainability

‘Green ambition towards sustainability’ is one of the hot research topics of the 21st century. With the sharp steering of the energy infrastructure toward fulfilling this radical expectation, the last decade has seen a global trend toward diversified sustainable renewable energy sources (such as solar, wind, and hydroelectric power) and electrification. Lithium-ion batteries (LIBs) are playing a significant role in this energy revolution. However, with the massive scale of the production of LIBs and their eventual retirement, attention has been turned to the erratic supply of raw materials used to manufacture these batteries and their disposal. Cathode regeneration technology is likely to be an optimal solution for the disposal of waste cathodes, aimed at non-destructively repairing and straightforwardly reusing degraded cathode materials for re-manufacturing LIBs with a shortened circular process, reasonable profits, and excellent efficiency. Additionally, cathode upcycling technology, aimed at upgrading the electrochemical performance of degraded materials, can be well adapted to the upgrading of battery chemistry and show excellent flexibility and potential for transforming the LIB industry from a resource-based to a circular economy. Thus, a holistic perspective based on the complete life cycle of LIBs is encouraged, and sustainability must be at the forefront regarding battery and pack design, raw material acquisition, materials synthesis, manufacturing, operating, retiring, and recycling processes of LIBs.

25 ENERGY STORAGE↗

Prototype Development, Testing, and Modeling for a Solar Light-Trapping Planar-Cavity Particle Receiver (LTPCR)

Many applications for concentrating solar thermal power (CSP) technologies of high efficiency power cycles or thermochemical processes require higher operating temperatures and alternative heat transfer media. Inert solid particles for next-generation CSP and reactive gas and/or solid media for solar thermochemical processes are common options; however, these have significantly lower heat transfer capabilities than thermal oil, molten salt, or molten metal media. Conventional solar receivers operating temperatures >700 degrees Celsius face challenges including thermal performance and thermal-mechanical issues. To overcome these limitations, we have developed a novel light-trapping, planar-cavity receiver (LTPCR) that can heat solid-phase media within an enclosed receiver while maintaining a high aperture solar flux concentration for high efficiency. This paper presents progress on design, fabrication, and testing of a 100 kWt prototype receiver to demonstrate the LTPCR operability and its commercial feasibility.

14 SOLAR ENERGY↗

Resilient and Cost-Effective Hybrid Li-Ion Battery Energy Storage System for Sites with Solar Generation and Electric Vehicle (EV) Charging (CRADA Final Report, CRD-19-00799)

The batteries of an energy storage system designed for multiple use-cases are traditionally selected to withstand the highest rate at which a battery is discharged relative to its maximum capacity (C-rate) and cycling requirements of the most intense use-case. However, this is not cost-effective given that the price of the batteries is strongly correlated to C-rate and cyclability. We propose to establish design guidelines for a hybrid energy storage system and test an edge controller that uses high-power and high-energy batteries for high- cyclability use cases such as frequency regulation and electric vehicle (EV) charging and low-cost batteries for low-power and low-cyclability use cases such as summer peak loads. The three main objectives of this proposal are (i) establishing sizing guidelines for such a hybrid storage system, (ii) installing a hybrid storage system in the Energy Systems Integration Facility (ESIF) sized based on those guidelines, and (iii) testing an edge controller specific for the system through hardware tests.

14 SOLAR ENERGY↗

Oxadiazole derivatives as stable anolytes for >3 V non-aqueous redox flow battery

Effective utilization of energy from renewable sources such as wind and solar requires the development of long duration energy storage (LDES) systems that can accommodate intermittent energy accrual. One option under investigation is the use of a redox flow battery (RFB). A significant amount of work has explored aqueous RFB systems with a variety of inorganic and organic carriers. However, moving to a nonaqueous solvent such as acetonitrile (MeCN) for RFB provides a much larger electrochemical window, which could lead to increased energy density if properly utilized. Here, in this work, we investigate a series of 2,5-diphenyl-1,3,4-oxadiazole (DiPhenOx) derivatives as anolytes for a redox flow battery. DiPhenOx has a low voltage redox event that, while reversible by cyclic voltammetry, was determined to be irreversible during bulk electrolysis. To improve cycling performance, we introduced various ester and cyano groups to the phenyl rings of DiPhenOx using molecular engineering. We characterized these derivatives spectroscopically and electrochemically to assess their feasibility for flow battery applications. The ester derivatives with the best cycling performance were tested in a flow cell vs. ferrocene, 2,5-di-tert-butyl-1,4-bis(2-methoxyethoxy)benzene (DBBB) and thianthrene, which resulted in ~2 V, ~3 V and ~3 V redox flow batteries, respectively.

25 ENERGY STORAGE↗

Analysis of degradation in residential battery energy storage systems for rate-based use-cases

This article examines the impact of residential battery energy storage (BES) systems' operational modes on the life (i.e. usable energy capacity) of the battery under several climatic conditions and battery chemistries. The sharp increase in residential BES installations has been a result of decreasing costs of batteries, increase in rate structures motivated applications such as solar self-consumption and time-of-use energy management, and customers purchasing these systems for backup power. While these different modes of operations provide a combination of increased bill savings, reliability of supply, and energy sustainability to the customer, their operational characteristics vary significantly between use-cases. Functional life of BES systems is known to be strongly dependent on their operating conditions. In this article, we analyze the operation of residential BES systems under different rate-based use-cases, for different battery chemistries and cell designs, and under different environmental conditions. This is conducted by simulating the control of BES operations using rate-based cycling algorithms and analyzing the prognosis of multiple battery lifetime models that consider complex nonlinear dependencies of operational stress factors such as state-of-charge, depth-of-discharge, and temperature on degradation. Significant variations in battery life are observed owing to the differences in characteristics of the uses-cases coupled with environmental conditions and battery chemistries. Such differences lead to the conclusion that choice of residential BES technologies and chemistries should account for their intended use-cases.

25 ENERGY STORAGE↗

A Dual-Mode Hybrid System Combining Solar Thermal With Pumped Thermal Energy Storage

A hybrid system that delivers renewable electricity generation and electricity storage capabilities is introduced. This dual-mode hybrid system is based on Pumped Thermal Energy Storage (PTES) which uses a heat pump to convert electricity into thermal energy that is trans-ferred to silica particles which are stored in concrete silos. The stored heat is later converted back to electricity in a heat engine. The heat pump and heat engine use a closed Joule-Brayton cycle and fluidized bed heat exchangers. If the PTES system is co-located with an array of concentrating solar mirrors and a particle receiver, then the silica particles may also be heated up by the concentrating solar power (CSP) system. The PTES heat engine may also be used to convert the stored solar heat into electricity, thereby sharing this system between the PTES and CSP systems and reducing costs. However, this requires careful management of the heat engine off-design parameters. A thermodynamic model is used to evaluate the performance of the dual mode PTES-CSP hybrid system. The model accounts for turbomachinery effi-ciency, and approach temperature and pressure loss in heat exchangers, as well as other sources of inefficiency, such as motor-generator losses, and air fan power. The hybrid system also requires the evaluation of the turbomachinery efficiency and pressure ratio at off-design conditions since the CSP system operates over different temperature ratios than the Carnot Battery. Several design variables and design modifications are investigated, such as pressure ratios and maximum temperatures.

14 SOLAR ENERGY↗