At least 253 records · Page 14

Time-Dependent Searches for Point Sources of Neutrinos with the 40-String and 22-String Configurations of IceCube

This paper presents four searches for flaring sources of neutrinos using the IceCube neutrino telescope. For the first time, a search is performed over the entire parameter space of energy, direction and time with sensitivity to neutrino flares lasting between 20 microseconds and a year duration from astrophysical sources. Searches which integrate over time are less sensitive to flares because they are affected by a larger background of atmospheric neutrinos and muons that can be reduced by the use of additional timing information. Flaring sources considered here, such as active galactic nuclei, soft gamma ray repeaters and gamma-ray bursts, are promising candidate neutrino emitters. Two searches are untriggered in the sense that they look for any possible flare in the entire sky and from a predefined catalog of sources from which photon flares have been recorded. The other two searches are triggered by multi-wavelength information on flares from blazars and from a soft gamma-ray repeater. One triggered search uses lightcurves from Fermi-LAT which provides continuous monitoring. A second triggered search uses information where the flux states have been measured only for short periods of time near the flares. The untriggered searches use data taken by 40 strings of IceCube between Apr 5, 2008 and May 20, 2009. The triggered searches also use data taken by the 22-string configuration of IceCube operating between May 31, 2007 and Apr 5, 2008. The results from all four searches are compatible with a fluctuation of the background.

Stamatikos, M.↗

Systems and methods for providing power to a load based upon a control strategy

Systems and methods are provided for an electrical system. The electrical system, for example, includes a first load, an interface configured to receive a voltage from a voltage source, and a controller configured to receive the voltage through the interface and to provide a voltage and current to the first load. The controller may be further configured to, receive information on a second load electrically connected to the voltage source, determine an amount of reactive current to return to the voltage source such that a current drawn by the electrical system and the second load from the voltage source is substantially real, and provide the determined reactive current to the voltage source.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power management for wireless nodes

A system includes a rectifier having an input configured to receive a variable AC input voltage and convert the AC input voltage to a rectified output voltage. A power converter has an input coupled to receive the rectified output voltage and to provide a DC supply voltage at an output thereof. A low drop-out regulator has an input coupled to receive the supply voltage and is configured provide a regulated voltage. A sensor is coupled to receive the regulated voltage as a power source and is configured to sense a condition and provide sensor data indicative of the sensed condition.

Feng, Philip X. L.↗

Initial Delayed Critical Configuration of SHEBA I and Subcritical Measurements by Californium Source-Driven Noise Analysis

In September 1980, the initial delayed critical configuration of the Solution High-Energy Burst Assembly (SHEBA I) was assembled, and the US Department of Energy’s Oak Ridge National Laboratory (ORNL) staff performed near critical and subcritical measurements using the californium source-driven noise analysis (CSDNA) method at the Los Alamos National Laboratory (LANL) Critical Experiments Facility. An unreflected 56 cm outside diameter stainless-steel cylindrical tank was partially filled with uranyl fluoride solution (235U enrichment was 4.95 wt %) until delayed criticality was achieved. Then, measurements were performed for various fuel solution heights from delayed critical to 60% of the height required for delayed criticality. The stainless-steel tank had an inside diameter of 54.6 cm and a height of 105 cm and was partially (20–36.5 cm) filled with an aqueous solution of uranyl fluoride (with a density of 2.162 g/cm 3 ). The density of the uranium in solution was 1.042 g/cm 3 , and the solution had a H/U atomic ratio of 20.43. The tank had a 6.35 mm wall thickness and an axial reentrant tube with an inside diameter of 6.02 cm and wall thickness of 0.165 cm. The tank was essentially unreflected on the top and sides because it was in a thin metal shed. The reactivity of the near–delayed critical configuration was −10.4 cents, which corresponds to a k eff value of 0.99922. In addition to the CSDNA measurements, the prompt neutron decay constants were determined from break frequency noise analysis (BNFA) measurements. The subcritical neutron multiplication factors from CSDNA and BFNA compared extremely well. These data can be used as the basis of International Nuclear Criticality Safety Evaluation benchmark for the near-critical configuration, and the k eff values at various subcritical configurations can be used as subcritical benchmarks. Furthermore, the measured prompt neutron decay constants can be used as reactor physics benchmarks. This report documents the experimental information for the measurements performed so that, at a later date, researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Criticality Safety Benchmark Evaluation Program (ICSBEP) or Nuclear Energy Agency benchmarks. The measured prompt neutron decay constants can be used as the basis of a benchmark for the International Reactor Physics Evaluation Program (IRPhEP). The data from these measurements are available from the ORNL Records Management Services Department, and the logbook is available from ICSBEP at Idaho National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Magnetic Dipole Inflation with Cascaded ARC and Applications to Mini-Magnetospheric Plasma Propulsion

Mini-Magnetospheric Plasma Propulsion (M2P2) seeks to create a plasma-inflated magnetic bubble capable of intercepting significant thrust from the solar wind for the purposes of high speed, high efficiency spacecraft propulsion. Previous laboratory experiments into the M2P2 concept have primarily used helicon plasma sources to inflate the dipole magnetic field. The work presented here uses an alternative plasma source, the cascaded arc, in a geometry similar to that used in previous helicon experiments. Time resolved measurements of the equatorial plasma density have been conducted and the results are discussed. The equatorial plasma density transitions from an initially asymmetric configuration early in the shot to a quasisymmetric configuration during plasma production, and then returns to an asymmetric configuration when the source is shut off. The exact reasons for these changes in configuration are unknown, but convection of the loaded flux tube is suspected. The diffusion time was found to be an order of magnitude longer than the Bohm diffusion time for the period of time after the plasma source was shut off. The data collected indicate the plasma has an electron temperature of approximately 11 eV, an order of magnitude hotter than plasmas generated by cascaded arcs operating under different conditions. In addition, indirect evidence suggests that the plasma has a beta of order unity in the source region.

Giersch, L.↗

Novel, Low-Cost, Light-Weight High Efficiency (H*10 Capable) Neutron Detector-Dosimeter

The goal of this project was to design, develop and validate a novel, spectroscopy enabled H*(10) neutron dosimetry system based on the tensioned metastable fluid detector (TMFD) sensor technology. The project team consisted of staff from Oak Ridge National Laboratory (ORNL), Purdue University (PU) and Sagamore Adams Laboratories, LLC (SAL). PU-SAL staff were tasked with the design, development, construction and testing of the H*TMFD hardware and software, along with developing the control and data acquisition software for comparison of predictions from H*TMFD against a commonly accepted and widely used industry standard system; for this project, the Li-I detector coupled to bonner spheres (LiI-BSS) system manufactured by Ludlum, Inc. was utilized as the reference (“gold”) standard – similar in terms of neutron spectroscopy enablement to another industry recognized, albeit, significantly higher cost (est. $300K) system referred to as “ROSPEC” (from BTI, Inc., which was not available for this project). ORNL staff were tasked with providing field-relevant guidance, apparatus and facilities for acquiring data against calibrated neutron sources, and comparing results of H*TMFD against LiI-BSS system predictions in a series of blind-tests conducted at ORNL. Over the course of 12 months, the PU-SAL-ORNL staff successfully accomplished the proposed technical and administrative tasks, inclusive of engaging in outreach to potential users of this technology in the DOE-wide infrastructure. The proposed tasks were successfully accomplished in timely manner; the follow-up type tasks pertaining to SBIR type Phases 2-3 were discussed and are initiated, inclusive of filing for intellectual property (IP) disclosures and possible patent filings by PU’s Office of Technology Commercialization (OTC). Two H*TMFD system architectures (see Exhibits 1 & 2 in the report) were developed and constructed for hand-portability by health-physicists (HPs) – the HP-H*TMFD, and the H*TMFD system which consists of a side-by-side mounted array of 4 TMFDs of 3 different sizes in sensitive volume (including one with borated fluid) that now simultaneously enables neutron energy spectroscopy: single bin for < 0.1 MeV, and 152 energy bins in the 0.1-15.2 MeV range; H*(10) dosimetry from ~5 μRem/h towards 10 R/h ranges. Several experiments were conducted using neutron sources in various configurations (shielded and unshielded). In direct comparison against the LiI-BSS industry standard (acquiring data for 26h each source), the H*TMFD system (acquiring data for ~6h for each source) offered H*(10) dose predictions for the most part accurate to within +/-10% for dose rates in the 100-300 μRem/h range. The LiI-BSS was impractical to use under ultra-low (~10 μRem/h) dose rate space, as also another metering device used at ORNL (Ludlum 4241L non-spectroscopy enabled) for which the lower limit is set by the manufacturer at 100 μRem/h. The enablement for efficient use in timely manner at the 10 μRem/h levels is deemed to be a strong enabling factor for H*TMFD for use in the DOE-nuclear laboratory arena. In terms of weight, the HP-H*TMFD weighs under ~5-7 lb.; the H*TMFD system weighs ~35-lb. As such, it is ~1/4 the weight of an LiI-BSS system weighing ~120 lb (LiI detector with 6 bonner spheres) and, ~1/2 the weight of ROSPEC. As a result of this activity, two involved post-doctoral student staff have now transitioned their knowledge and experiences to DOE’s Pacific Northwest National Laboratory (PNNL). A PU graduate student has also benefited from this project work which formed a principal basis for his Ph.D. dissertation work (in progress).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-frequency heating technique at the 18 GHz electron cyclotron resonance ion source of the National Institute of Radiological Sciences

The two-frequency heating technique was studied to increase the beam intensities of highly charged ions provided by the high-voltage extraction configuration (HEC) ion source at the National Institute of Radiological Sciences (NIRS). The observed dependences on microwave power and frequency suggested that this technique improved plasma stability but it required precise frequency tuning and more microwave power than was available before 2013. Recently, a new, high-power (1200 W) wide band-width (17.1–18.5 GHz) travelling-wave-tube amplifier (TWTA) was installed. After some single tests with klystron and TWT amplifiers the simultaneous injection of the two microwaves has been successfully realized. The dependence of highly charged ions (HCI) currents on the superposed microwave power was studied by changing only the output power of one of the two amplifiers, alternatively. While operating the klystron on its fixed 18.0 GHz, the frequency of the TWTA was swept within its full limits (17.1–18.5 GHz), and the effect of this frequency on the HCI-production rate was examined under several operation conditions. As an overall result, new beam records of highly charged argon, krypton, and xenon beams were obtained at the NIRS-HEC ion source by this high-power two-frequency operation mode.

43 PARTICLE ACCELERATORS↗

Variable-Depth Liner Evaluation Using Two NASA Flow Ducts

Four liners are investigated experimentally via tests in the NASA Langley Grazing Flow Impedance Tube. These include an axially-segmented liner and three liners that use reordering of the chambers. Chamber reordering is shown to have a strong effect on the axial sound pressure level profiles, but a limited effect on the overall attenuation. It is also shown that bent chambers can be used to reduce the liner depth with minimal effects on the attenuation. A numerical study is also conducted to explore the effects of a planar and three higher-order mode sources based on the NASA Langley Curved Duct Test Rig geometry. A four-segment liner is designed using the NASA Langley CDL code with a Python-based optimizer. Five additional liner designs, four with rearrangements of the first liner segments and one with a redistribution of the individual chambers, are evaluated for each of the four sources. The liner configuration affects the sound pressure level profile much more than the attenuation spectra for the planar and first two higher-order mode sources, but has a much larger effect on the SPL profiles and attenuation spectra for the last higher-order mode source. Overall, axially variable-depth liners offer the potential to provide improved fan noise reduction, regardless of whether the axially variable depths are achieved via a distributed array of chambers (depths vary from chamber to chamber) or a group of zones (groups of chambers for which the depth is constant).

Jones, M. G.↗

System and method for laser system having non-planar thin disc gain media

The present disclosure relates to a laser system. The laser system may have at least non-flat gain media disc. At least one pump source may be configured to generate a beam that pumps the non-flat gain media disc. A laser cavity may be formed by the pump source and the non-flat gain media disc. An output coupler may be included for receiving and directing the output beam toward an external component.

Dawson, Jay W.↗

Diffraction of sound by nearly rigid barriers

The diffraction of sound by barriers with surfaces of large, but finite, acoustic impedance was analyzed. Idealized source-barrier-receiver configurations in which the barriers may be considered as semi-infinite wedges are discussed. Particular attention is given to situations in which the source and receiver are at large distances from the tip of the wedge. The expression for the acoustic pressure in this limiting case is compared with the results of Pierce's analysis of diffraction by a rigid wedge. An expression for the insertion loss of a finite impedance barrier is compared with insertion loss formulas which are used extensively in selecting or designing barriers for noise control.

Hadden, W. J., Jr.↗

Time-Dependent Searches for Point Sources of Neutrinos with the 4O-String and 22-String Configurations of IceCube

This paper presents four searches for flaring sources of neutrinos using the IceCube neutrino telescope. For the first time, a search is performed over the entire parameter space of energy, direction, and time with sensitivity to neutrino flares lasting between 20 micro-s and a year duration from astrophysical sources. Searches that integrate over time are less sensitive to flares because they are affected by a larger background of atmospheric neutrinos and muons that can be reduced by the use of additional timing information. Flaring sources considered here, such as active galactic nuclei, soft gamma-ray repeaters, and gamma-ray bursts, are promising candidate neutrino emitters. Two searches are "untriggered" in the sense that they look for any possible flare in the entire sky and from a predefined catalog of sources from which photon flares have been recorded. The other two searches are triggered by multi-wavelength information on flares from blazars and from a soft gamma-ray repeater. One triggered search uses lightcurves from Fermi-LAT which provides continuous monitoring. A second triggered search uses information where the flux states have been measured only for short periods of time near the flares. The untriggered searches use data taken by 40 strings of IceCube between 2008 April 5 and 2009 May 20. The triggered searches also use data taken by the 22-string configuration of IceCube operating between 2007 May 31 and 2008 April 5. The results from all four searches are compatible with a fluctuation of the background.

Abbasi, R.↗

A three-dimensional model of co-rotating streams in the solar wind. 2: Hydrodynamic streams

Theoretical aspects of corotating solar wind dynamics on a global scale are explored by means of numerical simulations executed with a nonlinear, inviscid, adiabatic, single-fluid, three-dimensional (3-D) hydrodynamic formulation. A simple, hypothetical 3-D stream structure is defined on a source surface located at 35 solar radius and carefully documents its evolution to 1 AU under the influence of solar rotation. By manipulating the structure of this prototype configuration at the source surface, it is possible to elucidate the factors most strongly affecting stream evolution: (1) the intrinsic correlations among density, temperature, and velocity existing near the source; (2) the amplitude of the stream; (3) the longitudinal breadth of the stream; (4) the latitudinal breadth of the stream; and (5) the heliographic latitude of the centroid of the stream.

Pizzo, V. J.↗

LASERIX: An open facility for developments of soft X-ray and EUV lasers and applications

LASERIX is a high-power laser facility leading to High-repetition-rate XUV laser pumped by Titanium:Sapphire laser. The aim of this laser facility is to offer Soft XRLs in the 30-7 nm range and auxiliary IR beam that could also be used to produce synchronized XUV sources. This experimental configuration highly enhances the scientific opportunities of the facility, giving thus the opportunity to realize both X-ray laser experiments and more generally pump/probe experiments, mixing IR and XUV sources. In this contribution, the main results concerning both the development of XUV sources(X-Ray lasers and HHG sources) and their use for applications are presented.

43 PARTICLE ACCELERATORS↗

LLNL International Working Group on Gamma Spectrometry - Preparation of IDB Dataset

The spectral information and associated metadata, including source information, detector setup, and shielding configuration is described in human readable, comma-separated text files (csv). Five csv files are associated with each material type and include the following information (where [Isotope] is U, Pu, and MOX): [Isotope]_measurement_metadata - Metadata of the measurement configuration, including material composition at time of acquisition (decay corrected from certificate date). Data that is unique to a measurement configuration e.g. detector geometry, source-detector distance, analyzer and other electronics used, attenuating materials are provided in this file. [Isotope]_spectrum_metadata - The information that is unique to the spectrum. This includes detector specifications (e.g. date of acquisition, number of channels, gain (keV/channel), energy range, real and live time, full width half-maximum (FWHM) of the 186 or 208 peak for uranium or plutonium measurements, respectively. [Isotope]_source_metadata - The source material used for the measurement, this includes the ratio and uncertainties of isotopes present and processing information of the material. In addition, the certificate information for the source material is listed. [Isotope]_spectrum_counts_metadata - The counts per channel for each spectrum. This data is linked via the UID.spectrum index to the measurement_metadata file. [Isotope]_spectrum_checksum_metadata The MD5 checksum for the original spectrum file. This data is linked via the UID.spectrum index to the measurement_metadata file. This information is provided to prevent duplication of entries in the database.

42 ENGINEERING↗

LLNL International Working Group on Gamma Spectrometry - Preparation of IDB Dataset [Slides]

The spectral information and associated metadata, including source information, detector setup, and shielding configuration is described in human readable, comma-separated text files (csv). Six csv files are associated with each material type and include the following information (where [Isotope] is U, Pu, and MOX): [Isotope]_measurement_metadata Metadata of the measurement configuration, including material composition at time of acquisition (decay corrected from certificate date). Data that is unique to a measurement configuration e.g. detector geometry, source-detector distance, analyzer and other electronics used, attenuating materials are provided in this file. [Isotope]_spectrum_metadata The information that is unique to the spectrum. This includes detector specifications (e.g. date of acquisition, number of channels, gain (keV/channel), energy range, real and live time, full width half-maximum (FWHM) of the 186 or 208 peak for uranium or plutonium measurements, respectively. [Isotope]_source_metadata The source material used for the measurement, this includes the ratio and uncertainties of isotopes present and processing information of the material. In addition, the certificate information for the source material is listed. [Isotope]_spectrum_counts_metadata The counts per channel for each spectrum. This data is linked via the UID.spectrum index to the measurement_metadata file. [Isotope]_spectrum_checksum_metadata The MD5 checksum for the original spectrum file. This data is linked via the UID.spectrum index to the measurement_metadata file. This information is provided to prevent duplication of entries in the database. [Isotope]_provenance Details on the csv data provider, including laboratory and contract information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Accuracy control in Monte Carlo radiative calculations

The general accuracy law that rules the Monte Carlo, ray-tracing algorithms used commonly for the calculation of the radiative entities in the thermal analysis of spacecraft are presented. These entities involve transfer of radiative energy either from a single source to a target (e.g., the configuration factors). or from several sources to a target (e.g., the absorbed heat fluxes). In fact, the former is just a particular case of the latter. The accuracy model is later applied to the calculation of some specific radiative entities. Furthermore, some issues related to the implementation of such a model in a software tool are discussed. Although only the relative error is considered through the discussion, similar results can be derived for the absolute error.

Almazan, P. Planas↗