Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Snapshot multispectral imaging using a diffractive optical network

Abstract Multispectral imaging has been used for numerous applications in e.g., environmental monitoring, aerospace, defense, and biomedicine. Here, we present a diffractive optical network-based multispectral imaging system trained using deep learning to create a virtual spectral filter array at the output image field-of-view. This diffractive multispectral imager performs spatially-coherent imaging over a large spectrum, and at the same time, routes a pre-determined set of spectral channels onto an array of pixels at the output plane, converting a monochrome focal-plane array or image sensor into a multispectral imaging device without any spectral filters or image recovery algorithms. Furthermore, the spectral responsivity of this diffractive multispectral imager is not sensitive to input polarization states. Through numerical simulations, we present different diffractive network designs that achieve snapshot multispectral imaging with 4, 9 and 16 unique spectral bands within the visible spectrum, based on passive spatially-structured diffractive surfaces, with a compact design that axially spans ~72 λ m , where λ m is the mean wavelength of the spectral band of interest. Moreover, we experimentally demonstrate a diffractive multispectral imager based on a 3D-printed diffractive network that creates at its output image plane a spatially repeating virtual spectral filter array with 2 × 2 = 4 unique bands at terahertz spectrum. Due to their compact form factor and computation-free, power-efficient and polarization-insensitive forward operation, diffractive multispectral imagers can be transformative for various imaging and sensing applications and be used at different parts of the electromagnetic spectrum where high-density and wide-area multispectral pixel arrays are not widely available.

36 MATERIALS SCIENCE↗

Cosmic Axion Background detection using resonant cavity arrays

The axion is a well-motivated and generic extension of the Standard Model. If produced in the early universe, axions may still be relativistic today, forming a Cosmic Axion Background (CaB) potentially detectable in direct detection experiments. Although CaB is expected to be broadband, which makes it challenging to be detected, a high-quality-factor microwave cavity acts as a narrowband filter with response peaked at its resonant frequency. We propose a new strategy using multi-cavity arrays to distinguish signal from background noise by exploiting spatial correlations of the axion-induced electric field which are set by the cavity quality factor. We compute the two-point correlation function for electric fields in spatially separated cavities sourced by an isotropic CaB. Analyzing various cavity geometries, we find that stacked, wide-base cavity arrays offer coherent enhancement of the axion signal. We apply our formalism to prospective upgrades of the ADMX experiment, including configurations with four and eighteen coupled cavities. Although these arrays do not achieve a coherent enhancement, optimizing the geometry could potentially yield an $\mathcal{O}(1)$ improvement in the sensitivity to the CaB.

Axions and ALPs↗

Performance of an Array of 6 X 6 X 20 mm3 Virtual Frisch-Grid CdZnTe Detectors With A Waveform Sampling Readout System

Arrays of CdZnTe (CZT) bars with high spatial and energy resolution are an enabling technology for future space missions, such as the image plane detector of the Galactic Explorer with a Coded Aperture Mask Compton Telescope (GECCO). GECCO will explore the medium-energy (100 keV – 10 MeV) gamma-ray sky, which is among the least covered windows to the Universe with a massive potential for discovery. We have integrated an array of 6x6x20 mm3 virtual Frisch-grid (VFG) CZT detectors, measuring signals from the cathodes, anodes, and pads on each of the four sides of each bar. The VFG CZT detector is read out with an IDEAS GDS-100 waveform sampling readout system to optimize the signal processing and event reconstruction. We evaluated the energy and position resolution of the integrated VFG CZT array with a 137Cs source and successfully demonstrated better than 1% energy resolution and finer than 1 mm position resolution at 662 keV. Furthermore, we carried out a beam test at the High Intensity Gamma-ray Source (HIGS) at Duke University to investigate the performance of the system for higher energy gamma-rays. Together with the basic performance obtained from the 137Cs source, we present here those results from the beam test with various gamma-ray energies up to 8 MeV.

Makoto Sasaki↗

Multi-Channel Correlator Array-Fed Microwave Radiometer

New antenna feed technology is needed for microwave radiometers as aperture sizes continue to increase. Capability for contiguous coverage and spatial Nyquist sampling can be achieved using a multi-beam array-fed reflector architecture adapted from radio astronomy. In this ACT (Advanced Component Technology), a wideband feed array for use in a multi-channel (X-W bands) scanning microwave radiometer is in development. The team, including array provider Nuvotronics Inc., is also developing a laboratory instrument to demonstrate the performance of the array-fed architecture at 36.5 gigahertz using an 80-centimeter projected aperture. The feed array is an 11-element line array based on a microfabricated 8-40 gigahertz feed. Multiple beams are generated by exciting overlapping groups of elements with each group shifted by one element spacing within the array. The modeled antenna patterns reveal six beams with 0.8-degree beamwidth and 0.3-degree spacing. This configuration is also a 1:26 electromagnetic scale model of a 1.41 gigahertz radiometer with a 21-meter aperture. The array-fed architecture for microwave radiometers has the potential to solve the developing need for high-spatial resolution, large aperture instruments. The objective relevancy scenario is a 6-meter aperture X-W band scanning radiometer purposed for high-resolution all-weather imaging of Earth's atmosphere and land, ice and ocean surfaces.

Microwave Radiometer↗

High-Density, High-Bandwidth, Multilevel Holographic Memory

A proposed holographic memory system would be capable of storing data at unprecedentedly high density, and its data transfer performance in both reading and writing would be characterized by exceptionally high bandwidth. The capabilities of the proposed system would greatly exceed even those of a state-of-the art memory system, based on binary holograms (in which each pixel value represents 0 or 1), that can hold .1 terabyte of data and can support a reading or writing rate as high as 1 Gb/s. The storage capacity of the state-of-theart system cannot be increased without also increasing the volume and mass of the system. However, in principle, the storage capacity could be increased greatly, without significantly increasing the volume and mass, if multilevel holograms were used instead of binary holograms. For example, a 3-bit (8-level) hologram could store 8 terabytes, or an 8-bit (256-level) hologram could store 256 terabytes, in a system having little or no more size and mass than does the state-of-the-art 1-terabyte binary holographic memory. The proposed system would utilize multilevel holograms. The system would include lasers, imaging lenses and other beam-forming optics, a block photorefractive crystal wherein the holograms would be formed, and two multilevel spatial light modulators in the form of commercially available deformable-mirror-device spatial light modulators (DMDSLMs) made for use in high speed input conversion of data up to 12 bits. For readout, the system would also include two arrays of complementary metal oxide/semiconductor (CMOS) photodetectors matching the spatial light modulators. The system would further include a reference-beam sterring device (equivalent of a scanning mirror), containing no sliding parts, that could be either a liquid-crystal phased-array device or a microscopic mirror actuated by a high-speed microelectromechanical system. Time-multiplexing and the multilevel nature of the DMDSLM would be exploited to enable writing and reading of multilevel holograms. The DMDSLM would also enable transfer of data at a rate of 7.6 Gb/s or perhaps somewhat higher.

Chao, Tien-Hsin↗

Continuum Modeling of the Dynamics of Externally Injection Locked Coupled Oscillator Arrays

Mutually injection locked arrays of electronic oscillators provide a novel means of controlling the aperture phase of a phased array antenna thus achieving the advantages of spatial power combining while retaining the ability to steer the radiated beam. In this work we develop a continuum model which results in a single partial differential equation for the aperture phase as a function of time.

Coupled↗

The preferred spatial mode of instability for a Mach 2 jet

Phase-averaged schlieren video and an array of azimuthally oriented microphones were used in the experiments performed to determine the preferred spatial structure associated with supersonic nozzle design for an exhaust Mach number of 2. The jet flow was unheated, chemically inert, and submerged in a static environment, conditions that are satisfactory for the quasi-linear wave-analytical model of Tam and Morris (1980) and Tam and Burton (1984). For general conditions of undeterminate phase-averaged optical records, a conditional sampling method was devised, based on fundamental multimode components. This method uncovers the preferred spatial structure, and shows that in addition to the dominant jet flapping mode, there is also a significant contribution from the axisymmetric mode. Near-field correlations with a moving microphone indicate that the flapping plane is nearly stationary, and not spinning as in the Westley and Wolley (1975) experiment.

Seiner, J. M.↗

Nanosecond Gated CMOS Camera (NSGCC) ICD (Rev. 2.1)

The Ultra-Fast X-ray Imager (UXI) program is an ongoing effort at Sandia National Laboratories to create high speed, multi-frame, time-gated Read Out Integrated Circuits (ROICs), and a corresponding suite of photodetectors to image a wide variety of High Energy Density (HED) physics experiments on both Sandia’s Z-Machine and LLNL’s National Ignition Facility (NIF). Several cameras have been designed over the length of the program; one of the most recent is the Icarus, which is an improvement on past imagers (Furi and Hippogriff). A second sensor that can be connected is the Daedalus sensor. The Icarus is a 1024 × 512-pixel array with either 25 μm or 8 µm spatial resolution containing four frames of storage per pixel and has improved timing generation and distribution components while achieved 2 ns time gating. The Daedalus sensor is also a 1024 x 512-pixel array with 25 µm special resolution containing three frames of storage per pixel and has an increased set of features for a wider variety of applications from interlacing of rows in each frame to configurability of all shutters. See Section 14 for details regarding the Icarus implementation of the firmware and Section 15 for details regarding the Daedalus implementation. Due to the unique test environments UXI sensors are targeted for, full custom hardware was required to physically mount an Icarus or Daedalus sensor, manage its various functions, and read out pixel data for transfer to a host computer. Beyond experimental functionality, the hardware also needed to accommodate sensor characterization requirements. Lawrence Livermore National Laboratory’s ‘Version 4.0 Board’ was the result of these efforts. It mounts all the components required to fully utilize the Icarus and Daedalus sensors including analog to digital converters to convert pixel data and various system voltages to digital form for readout and analysis, DAC channels for remote configuration of critical bias voltages, static random-access memories to buffer pixel data, RS422 and Gigabit Ethernet communications for remote access, and an FPGA to tie these components together. This document describes the FPGA electrical interfaces in detail to allow the reader a greater understanding of the device, and to facilitate implementation of custom software to control and manage it. The Version 4.0 Board is a continuation of the Nano-second Gated CMOS hardware design that retains much of the functionality of the Version 1.0 Board while adding features including a DAC instead of digital potentiometers, as well as sensors for pressure and radiation. The Version 4.0 board is intended for applications requiring tight form-factor enclosures. It is composed of two stacking boards; one holds the FPGA and regulators to power the various components of the board while the other contains the mating connector to the sensor, image-readoff ADCs, the DAC, and other components.

42 ENGINEERING↗

Secure Wireless Communication Using Distributed Coherent Transmission and Spatial Signal Decomposition

We present a new approach to secure wireless communications using coherent distributed transmission of signals that are spatially decomposed between a two-element distributed antenna array. High-accuracy distributed coordination of microwave wireless systems supports the ability to transmit different parts of a signal from separate transmitters such that they combine coherently at a designated destination. In this article, we explore this concept using a two-element coherent distributed phased array where each of the two transmitters sends a separate component of a communication signal, where each symbol is decomposed into a sum of two pseudorandom signal vectors, the coherent summation of which yields the intended symbol. By directing the transmission to an intended receiver using distributed beamforming, the summation of the two vector components is largely confined to a spatial region at the destination receiver. We implement the technique in a $50−λ$ array operating at 3 GHz. We evaluate the symbol error rate (SER) in 2-D space through simulation and measurement, showing that the approach yields a spatially confined secure region where the information is recoverable (i.e., the received signal has low SER), and outside of which the information is unrecoverable (high SER). The proposed system is also compared against a traditional beamforming system where each node sends the same data. We validate experimentally that our approach achieves a low SER of 0.0082 at broadside and an SER above 0.25 at all other locations compared to a traditional beamforming approach that achieves a SER of 0 at all locations measured.

Engineering - Electronic and electrical engineerin↗

Airborne imaging spectrometer II - The optical design

The Airborne Imaging Spectrometer (AIS I) was a multispectral infrared imaging instrument utilizing a 32 x 32 element mercury-cadmium-telluride detector array. A novel optical design provided high spectral resolution and, in conjunction with the 32-element spatial resolution, made optimal use of the capabilities of the area array. The operational successes of this proof-of-concept instrument, coupled with advances in infrared detector array technology, have provided the impetus and opportunity to upgrade the instrument by replacing the sensor with a newly developed 64 x 64 detector. The original instrument configuration is reviewed, and the design considerations, limitations and trade-offs necessitated by the new detector are examined, particularly the near doubling of the field of view and the increase from 1024 to 4096 pixels per read-out frame.

La Baw, Clayton↗

GRB 060505: A Possible Short-Duration Gamma-Ray Burst in a Star Forming Region at Redshift of 0.09

On May 5, 2006 a four-second duration, low-energy, approximately 10(exp 59) erg, Gamma-Ray Burst (GRB) was observed, spatially associated with a z=0.0894 galaxy. Here, we report the discovery of the GRB optical afterglow and observations of its environment using gemini-south, Hubble Space Telescope (HST), Chandra, Swift and the Very Large Array. The optical afterglow of this GRB is spatially associated with a prominent star forming region in the Sc-type galaxy 2dFGRS S173Z112. Its proximity to a star forming region suggests that the progenitor delay time, from birth to explosion, is smaller than about 10 Myr. Our HST deep imaging rules out the presence of a supernova brighter than an absolute magnitude of about -11 (or -126 in case of 'maximal' extinction) at about two weeks after the burst, and limits the ejected mass of radioactive Nickel 56 to be less than about 2x10(exp -4) solar mass (assuming no extinction). Although it was suggested that GRB 060505 may belong to a new class of long-duration GRBs with no supernova, we argue that the simplest interpretation is that the physical mechanism for this burst is the same as for short-duration GRBs.

Ofek, E. O.↗

Stronger field-emission science via coupling novel nanoscale imaging techniques

We implemented a vacuum field emission electron microscope (FEM) using the electron optics of a low-energy /photoemission electron microscope (LEEM/PEEM). Historically, there have been other FEM hardware platforms, and the distinctive feature of our method is that it integrates with the LEEM/PEEM and associated techniques, enabling a powerful multi-capability toolset for studying fundamental materials properties underpinning field emission (FE) and vacuum arc initiation. Typically, LEEM is used to image surface structure, which influences both work function and electric field distribution near a surface, while PEEM is used to map photoelectric work function across a surface. Our FEM adds the capability for spatially-correlated coincident-site measurements of FE currents to go-along with structure and work function. LEEM, PEEM, and our FEM implementation achieve nanoscale spatial resolution relevant for materials studies in nanoscience/engineering. Our approach requires a straightforward calibration of the electron optics to enable focused FEM imaging under intentional electric field variation. We demonstrate the FEM approach by imaging field emitter arrays relevant for vacuum nanoelectronics. We demonstrate submicron spatial resolution and dynamic measurement of FE versus applied electric field. We anticipate this capability will enable fundamental structure-function studies of FE and arc initiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron-Beam-Induced Molecular Plasmon Excitation and Energy Transfer in Silver Molecular Nanowires

In this work, we investigate (1) electron-beam-induced plasmon absorption spectra of Ag molecular nanowire dimers and (2) electron-beam-induced energy transfer between two nanowires. We employ linear-response time-dependent density functional theory (TDDFT) and real-time TDDFT methods to simulate the electron-beam-induced plasmonic excitations, dynamics, and corresponding electron energy loss spectrum for small models of a single molecular nanowire with four Ag atoms and for two Ag nanowires. An array of different relative orientations of nanowires and of different initial excitation conditions resulting from applying an electron beam at different positions with respect to the Ag nanowires is investigated. The results demonstrate (1) an electron beam can induce plasmonic excitations from the molecular Ag nanowire ground state to the excited states that are both optically allowed and forbidden, (2) a tunability for selective excitations that can be controlled by the position of a focused electron beam, and (3) kinetic and dynamic behaviors of time-dependent electron-beam-induced energy transfer between two Ag molecular nanowires depend on the position of the beam source and nanowire separation distance, providing insights into the spatial dependences of plasmonic couplings in nanowire arrays.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Skin-integrated stretchable actuators toward skin-compatible haptic feedback and closed-loop human-machine interactions

Abstract Skin-integrated haptic interfaces that can relay a wealth of information from the machine to the human are of great interest. However, existing haptic devices are not yet able to produce haptic cues that are compatible with the skin. In this work, we present the stretchable soft actuators for haptic feedback, which can match the perception range, spatial resolution, and stretchability of the skin. Pressure-amplification structures are fabricated using a scalable self-assembly process to ensure an output pressure beyond the skin perception threshold. Due to the minimized device size, the actuator array can be fabricated with a sufficiently high spatial resolution, which makes the haptic device applicable for skin locations with the highest spatial acuity. A haptic feedback system is demonstrated by employing the developed soft actuators and highly sensitive pressure sensors. Two proof-of-concept applications are developed to illustrate the capability of transferring information related to surface textures and object shapes acquired at the robot side to the user side.

Chen, Si↗

Continuum Modeling of the Dynamics of Externally Injection-locked Coupled Oscillator Arrays

Mutually injection-locked arrays of electronic oscillators provide a novel means of controlling the aperture phase of a phased-array antenna, thus achieving the advantages of spatial power combining while retaining the ability to steer the radiated beam. In a number of design concepts, one or more of the oscillators are injection locked to a signal from an external master-oscillator. The behavior of such a system has been analyzed by numerical solution of a system of nonlinear differential equations which, due to its complexity, yields limited insight into the relationship between the injection signals and the aperture phase. In this paper, we develop a continuum model, which results in a single partial differential equation for the aperture phase as a function of time. Solution of the equation is effected by means of the Laplace transformation and yields detailed information concerning the dynamics of the array under the influence of the external injection signals.

injection locked↗

High spatial resolution infrared imaging of L1551-IRS 5 - Direct observations of its circumstellar envelope

Images of L1551-IRS 5 were obtained at 1.65, 2.2, and 3.8 microns using the University of Rochester's Infrared Array Camera. It is found that IRS 5 is spatially resolved, and that it is elongated: the observed FWHM size of IRS 5 is 4.1 x 2.8 arcsec-squared at 2.2 microns. These observations are interpreted in terms of a flattened circumstellar envelope that is viewed from about 18 deg above its equatorial plane, a configuration that has been treated theoretically by Lefevre et al. In this model the central star is not seen directly, but only light scattered toward the observer from the visible polar region, where the envelope is thinnest, is observed. It is deduced that the envelope has a diameter of 1000 AU, a molecular hydrogen density of greater than or approximately equal to 4 x 10 to the 6th/cu cm, and a mass of greater than or approximately equal to 0.02 M solar mass, which results in an extinction of Av greater than about 33 mag to the central source.

Moneti, Andrea↗

Simultaneous multibeam sounding of wind and turbulence

Most clear air radars use an antenna with either a few fixed beam positions or one that can be steered to a number of beam positions, one position at a time. For spatial studies of parameters that can change rapidly these conventional radar may be severely limited. The problem is that the fixed beam radars do not cover enough positions and the steerable radars may not be able to cover the entire field of interest in a short enough time period. Preliminary results are presented from a brief experiment that suggests a way to overcome some of these space-time problems in clear air radar research. A typical clear air radar antenna located in France was modified in a simple way to produce a number of beam simultaneouly. The radar, the modifications and the resulting beam patterns are described. Spectra is then shown obtained with the multibeam array and some results are presented on the spatial variations of reflectivity. Both the positive and negative aspects of using a multibeam antenna array for clear air radar studies are summarized.

Brun, E.↗

Optical signal processing of spatially distributed sensor data in smart structures

Smart structures which contain dense two- or three-dimensional arrays of attached or embedded sensor elements inherently require signal multiplexing and processing capabilities to permit good spatial data resolution as well as the adequately short calculation times demanded by real time active feedback actuator drive circuitry. This paper reports the implementation of an in-line optical signal processor and its application in a structural sensing system which incorporates multiple discrete optical fiber sensor elements. The signal processor consists of an array of optical fiber couplers having tailored s-parameters and arranged to allow gray code amplitude scaling of sensor inputs. The use of this signal processor in systems designed to indicate the location of distributed strain and damage in composite materials, as well as to quantitatively characterize that damage, is described. Extension of similar signal processing methods to more complicated smart materials and structures applications are discussed.

Bennett, K. D.↗