Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chirped-grating spectrometer-on-a-chip

We demonstrate an on-chip spectrometer readily integrable with CMOS electronics. The structure is comprised of a SiO 2 /Si 3 N 4 /SiO 2 waveguide atop a silicon substrate. A transversely chirped grating is fabricated, in a single-step optical lithography process, on a portion of the waveguide to provide angle and wavelength dependent coupling to the guided mode. The spectral and angular information is encoded in the spatial dependence of the grating period. A uniform pitch grating area, separated from the collection area by an unpatterned propagation region, provides the out-coupling to a CMOS detector array. A resolution of 0.3 nm at 633 nm with a spectral coverage tunable across the visible and NIR (to ∼ 1 µm limited by the Si photodetector) by changing the angle of incidence, is demonstrated without the need for any signal processing deconvolution. This on-chip spectrometer concept will cost effectively enable a broad range of applications that are beyond the reach of current integrated spectroscopic technologies.

Nezhadbadeh, Shima↗

Acoustic diagnostic system and method for superconducting devices operating in gas or liquid

A novel system and method for detecting a quench of a superconducting conductor and detecting abnormal behavior of a superconducting conductor using acoustic sensor technology in the coolant of a superconducting cable and/or magnet is disclosed. This system and method is not only limited to use for superconductors, but also may be used for any device disposed in liquid and gas. Acoustic sensors are installed along a coolant space of a superconducting conductor and monitor coolant conditions. By monitoring acoustic changes, temperature changes or coolant flow disruption can be detected very quickly by an acoustic sensor array. By disposition of the acoustic sensor array in a coolant flow channel, the acoustic sensor system can quickly detect a local condition, such as the thermal status (temperature) of a superconducting cable and magnet with precise spatial resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spatially resolved molecular gas properties of host galaxy of Type I superluminous supernova SN 2017egm

Abstract We present the results of CO(1–0) observations of the host galaxy of a Type I superluminous supernova (SLSN-I), SN 2017egm, one of the closest SLSNe-I at z = 0.03063, by using the Atacama Large Millimeter/submillimeter Array. The molecular gas mass of the host galaxy is Mgas = (4.8 ± 0.3) × 109 M⊙, placing it on the sequence of normal star-forming galaxies in an Mgas–star-formation rate (SFR) plane. The molecular hydrogen column density at the location of SN 2017egm is higher than that of the Type II SN PTF10bgl, which is also located in the same host galaxy, and those of other Type II and Ia SNe located in different galaxies, suggesting that SLSNe-I have a preference for a dense molecular gas environment. On the other hand, the column density at the location of SN 2017egm is comparable to those of Type Ibc SNe. The surface densities of molecular gas and the SFR at the location of SN 2017egm are consistent with those of spatially resolved local star-forming galaxies and follow the Schmidt–Kennicutt relation. These facts suggest that SLSNe-I can occur in environments with the same star-formation mechanism as in normal star-forming galaxies.

Hatsukade, Bunyo (ORCID:0000000164698725)↗

Super-Resolution Ptychography with Small Segmented Detectors

To overcome the spatial resolution limit set by aperture-limited diffraction in traditional scanning transmission electron microscopy, microscopists have developed ptychography enabled by iterative phase retrieval algorithms and high-dynamic-range pixel array detectors. Current detector designs are limited by the data rate off chip, so a high-pixel-count detector has a proportionally lower frame rate than the few-segment detectors used for differential phase contrast (DPC) imaging. This slower acquisition speed leads to heightened vulnerability to scan noise, drift, and potential sample damage. This creates opportunities for repurposing fast segmented detectors for ptychography by trading a reduction in reciprocal space pixels for an increase in real space pixels. Here, we explore a strategy of oversampling in real space and instead apply detector pixel upsampling during the reconstruction process. Further, we demonstrate the viability of achieving super-resolution ptychography on thin objects using only 2 × 2 detector pixels, surpassing the resolution of integrated DPC (iDPC) imaging. With optimization using simulated datasets and experiments on MoTe 2 /WSe 2 bilayer moiré superlattices, we achieved super-resolution ptychography reconstructions under rapid acquisition conditions (37.5 pA, 1 μs dwell time), yielding over 50% improvements in contrast and information limit compared to annular dark field and iDPC imaging on the same detectors.

2D materials↗

Binary pseudo-random array (BPRA) for inspection and calibration for cylindrical wavefront interferometry

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. However, surface topography measurements are instrument dependent, and without the knowledge of how the instrument performs under the practical usage conditions, the measured data contain some degree of uncertainty. Binary Pseudo Random Array (BPRA) “white noise” artifact are effective and useful for characterizing the Instrument Transfer Function (ITF) of surface topography metrology tools and wavefront measurement instrument. BPRA artifact contains features with all spatial frequencies in the instrument bandpass with equal weight. As a result, power spectral density of the patterns has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range. The application examples include electron microscopes, x-ray microscopes, interferometric microscopes, and large field-of-view Fizeau Interferometers. Furthermore, we will introduce the application of BPRA method to characterizing the ITF of Cylindrical Wavefront Interferometry (CWI), by developing the BPRA artifact which matches the radius of curvature of the cylindrical wavefront. The data acquisition and analysis procedures for different applications of the ITF calibration technique developed are also discussed.

Munechika, K↗

An on-chip phased array for non-classical light

Abstract Quantum science and technology can offer fundamental enhancements in sensing, communications and computing. The expansion from wired to wireless links is an exciting prospect for quantum technologies. For classical technologies, the advent of phased arrays enabled directional and adaptive wireless links by manipulating electromagnetic waves over free space. Here we demonstrate a phased array system on a chip that can receive, image and manipulate non-classical light over free space. We use an integrated photonic-electronic system with more than 1000 functional components on-chip to detect squeezed light. By integrating an array of 32 sub-wavelength engineered metamaterial antennas, we demonstrate a direct free-space-to-chip interface for reconfigurable quantum links. On the same chip, we implement a large-scale array of quantum-limited coherent receivers that can resolve non-classical signals simultaneously across 32 channels. With coherent readout and manipulation of these signals, we demonstrate 32-pixel imaging and spatially configurable reception of squeezed light over free space. Our work advances wireless quantum technologies that could enable practical applications in quantum communications and sensing.

Science & Technology - Other Topics↗

Patterned anodes with sub-millimeter spatial resolution for large-area MCP-based photodetector systems

Micro-channel-plate-based photo-detectors are unique in being capable of covering very large areas such as those required in elementary particle and nuclear physics, while providing sub-millimeter space resolution, time resolutions of less than 10 picoseconds for charged particles, and time resolutions of 30 psec–50 psec for single photons. In such systems the electronic channel count is a major cost driver. Incorporating a capacitively-coupled anode allows the use of external pickup electrodes with patterns of individual channels optimized for occupancy, rate, and time/space resolution. The signal pickup antenna can be economically implemented as a printed circuit card with a 2-dimensional array of pads for high-occupancy/high-rate applications such as in particle colliders and medical imaging, or a 1-dimensional array of strips for a lower channel count in low-occupancy/low-rate applications such as large neutrino detectors. In this paper we present pad patterns that enhance signal-sharing between pads to lower the channel count per unit area in large-area systems by factors up to 4, while maintaining spatial resolutions of approximately 100 to 200 μ m for charged particles and 400 to 1000 μ m for single photons. Patterns that use multiple signal layers in the signal-pickup board can lower the channel count even further, moving the scaling behavior in the number of pads versus total area from quadratic to linear.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Carrier-Envelope Phase Control in Terahertz Pulse Generation Using InAs Ribbon Metasurfaces

Generation of broadband terahertz (THz) pulses with variable polarization and carrier-envelope phase can enable the tailoring of THz beam wavefronts for advanced applications in THz imaging and spectroscopy and for strong THz field optics. While metasurfaces composed of deeply subwavelength THz emitters have recently been demonstrated to define the polarization and spatial profile of the generated THz fields, precise phase control or synthesis of THz pulse waveforms remains a challenging problem. Here, we propose and demonstrate metasurfaces composed of indium arsenide (InAs) nanoscale ribbon arrays capable of generating THz pulses with variable carrier-envelope phase. We show that different THz generation mechanisms, each contributing distinct phases, can be activated in the ribbons, enabling carrier-envelope phase control spanning a range of π over a wide band of frequencies (∼1–3 THz). This is achieved solely through the ribbon array geometry using linearly polarized optical excitation of the ribbons. The arrays enable precise control of the THz phase and amplitude, opening the door to advanced structured THz wavefront synthesis using ultrathin dielectric metasurfaces.

carrier-envelope phase↗

bifacialVF - Bifacial PV View Factor model 2022 [SWR 17-58]

bifacialvf is a self-contained view factor (or configuration factor) model which replicates a 5-row PV system of infinite extent perpendicular to the module rows. Single-axis tracking is supported, and hourly output files based on TMY inputs are saved. Spatial nonuniformity is reported, with multiple rear-facing irradiances collected on the back of each module row. Bilinear interpolation code add-on to bifacialvf (description below) to pre-generate IV arrays and bifacial coefficients, and to examine the energy production with back side irradiance mismatch for either a portrait or landscape module. Included are IV curves and bifacial info for a Yingli (standard) module. Based on the publication: "A Practical Irradiance Model for Bifacial PV Modules" B. Marion, S. MacAlpine, C. Deline, A. Asgharzadeh, F. Toor, D. Riley, J. Stein, C. Hansen 2017 IEEE Photovoltaic Specialists Conference, Washington DC, 2017 URL: https://www.nrel.gov/docs/fy17osti/67847.pdf

Deline, Chris↗

Spatiotemporal analysis of 3D human iPSC-derived neural networks using a 3D multi-electrode array

While there is a growing appreciation of three-dimensional (3D) neural tissues (i.e., hydrogel-based, organoids, and spheroids), shown to improve cellular health and network activity to mirror brain-like activity in vivo , functional assessment using current electrophysiology techniques (e.g., planar multi-electrode arrays or patch clamp) has been technically challenging and limited to surface measurements at the bottom or top of the 3D tissue. As next-generation MEAs, specifically 3D MEAs, are being developed to increase the spatial precision across all three dimensions (X, Y, Z), development of improved computational analytical tools to discern region-specific changes within the Z dimension of the 3D tissue is needed. In the present study, we introduce a novel computational analytical pipeline to analyze 3D neural network activity recorded from a “bottom-up” 3D MEA integrated with a 3D hydrogel-based tissue containing human iPSC-derived neurons and primary astrocytes. Over a period of ~6.5 weeks, we describe the development and maturation of 3D neural activity (i.e., features of spiking and bursting activity) within cross sections of the 3D tissue, based on the vertical position of the electrode on the 3D MEA probe, in addition to network activity (identified using synchrony analysis) within and between cross sections. Then, using the sequential addition of postsynaptic receptor antagonists, bicuculline (BIC), 2-amino-5-phosphonovaleric acid (AP-5), and 6-cyano-5-nitroquinoxaline-2,3-dione (CNQX), we demonstrate that networks within and between cross sections of the 3D hydrogel-based tissue show a preference for GABA and/or glutamate synaptic transmission, suggesting differences in the network composition throughout the neural tissue. The ability to monitor the functional dynamics of the entire 3D reconstructed neural tissue is a critical bottleneck; here we demonstrate a computational pipeline that can be implemented in studies to better interpret network activity within an engineered 3D neural tissue and have a better understanding of the modeled organ tissue.

3D culture↗

The Illumination of Thunderclouds by Lightning: 1. The Extent and Altitude of Optical Lightning Sources

Abstract Optical space‐based lightning sensors including NOAA's Geostationary Lightning Mapper (GLM) detect lightning though its transient illumination of the surrounding clouds. What space‐based optical lightning sensors measure is influenced by the physical attributes of the light source, the location of the source within the cloud scene, and the spatial variations in cloud composition. We focus on the lightning channels that serve as optical sources for GLM groups and flashes in this first part of our thundercloud illumination study. We match Lightning Mapping Array (LMA) sources with GLM groups and flashes during two thunderstorms to examine channel segments that are active during optical emission. We find that in each storm, the LMA sources matched with GLM groups are small (median: 3 km) compared to GLM pixels (nominal: 8 km), and preferentially come from high altitudes in the cloud (>8–10 km). The detection advantage for high‐altitude sources permits GLM to resolve faint optical pulses near the cloud top that might be missed from lower altitudes. However, the most energetic groups can be detected from all altitudes, and the largest groups largely originate at low altitudes. The relationship between group energy and illuminated area depends on flash development within the cloud medium, and flash development into different cloud regions can be identified by tracking GLM metrics of cloud illumination over time.

58 GEOSCIENCES↗

Development of Optical Fiber-Based Sensors for Nuclear Microreactor Structural Health Monitoring

This report provides an experimental assessment of two different optical fiber–based acoustic sensors that are being investigated for application in nuclear microreactors to enhance structural health monitoring capabilities. Optical fibers are resilient in high-temperature and high-radiation environments, have a small sensor footprint, are immune to electromagnetic interference, and are capable of spatially distributed sensing. The two sensors investigated here are (1) Fabry–Pérot Cavities (FPCs) between two copper-coated fibers, embedded in nickel capillary tubes and (2) type-I fiber Bragg grating (FBG) arrays contained within metal capillary tubes. These sensors can be interrogated using low-coherence interferometry or swept wavelength interferometry, respectively, to measure the resonant frequencies of the components or systems to which these sensors are bonded. The FPC developed herein has been subjected to temperatures up to nearly 800°C while tack-welded to a tubular test specimen. Even at the highest temperatures, the measured resonant frequencies compared well with those obtained using an accelerometer that was bonded to an unheated portion of the specimen. The FBG array was tested in multiple bonding configurations to a tubular test specimen, all at room temperature, with the understanding that high temperature (i.e., type II) FBGs could be used to obtain similar data at high temperatures; the FBG array data were validated with noncontact laser vibrometry, which is being used at Los Alamos National Laboratory to relate acoustic signatures to component stresses and/or structural defects. The goal of this work is to identify the most promising techniques that are also compatible with operation in a microreactor environment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Big Data Meets Geothermal Exploration (CRADA Final Report)

As part of the Cyclotron Road program, Zanskar Geothermal & Minerals, Inc. investigated the application of micro-earthquake and ambient noise seismology methods to imaging and characterizing the structural characteristics and hydrothermal flux of subsurface faults. Significant advances in what could be resolved were enabled by two major developments in seismology: 1) the availability of large-n arrays of low-cost seismometers, and 2) the availability of increased computational power and semi-automated data reduction algorithms. In tandem, these advances may improve the signal-to-noise ratio and spatial precision of the data collected and enable higher-resolution characterization of subsurface fracture systems and their spatio-temporal evolution. These tools supported efforts to reduce dry-hole risk and to improve wellfield productivity for geothermal resource development. In particular, two applications of these advances were evaluated: 1) fracture-seismic imaging, which was used to detect ambient emissions from fluid-filled fractures, and 2) reservoir tomography, which used information about travel paths, source locations, and source parameters of micro-earthquakes to identify areas of enhanced permeability. Integration of these methods provided guidance for siting wells and served as prior constraints for reservoir models, informing forecasts of power potential and production and injection strategies aimed at minimizing temperature decline and improving overall resource productivity.

15 GEOTHERMAL ENERGY↗

BASS XXXII: Studying the Nuclear Millimeter-wave Continuum Emission of AGNs with ALMA at Scales ≲100–200 pc

To understand the origin of nuclear (≲100 pc) millimeter-wave (mm-wave) continuum emission in active galactic nuclei (AGNs), we systematically analyzed subarcsecond resolution Band-6 (211–275 GHz) Atacama Large Millimeter/submillimeter Array data of 98 nearby AGNs (z < 0.05) from the 70 month Swift/BAT catalog. The sample, almost unbiased for obscured systems, provides the largest number of AGNs to date with high mm-wave spatial resolution sampling (~1–200 pc), and spans broad ranges of 14–150 keV luminosity {$40\lt \mathrm{log}[{L}_{14-150}/(\mathrm{erg}\,{{\rm{s}}}^{-1})]\lt 45$}, black hole mass $[5\lt \mathrm{log}({M}_{\mathrm{BH}}/{M}_{\odot })\lt 10$], and Eddington ratio ($-4\lt \mathrm{log}{\lambda }_{\mathrm{Edd}}\lt 2$). We find a significant correlation between 1.3 mm (230 GHz) and 14–150 keV luminosities. Its scatter is ≈0.36 dex, and the mm-wave emission may serve as a good proxy of the AGN luminosity, free of dust extinction up to N H ~ 10 26 cm –2 . While the mm-wave emission could be self-absorbed synchrotron radiation around the X-ray corona according to past works, we also discuss different possible origins of the mm-wave emission: AGN-related dust emission, outflow-driven shocks, and a small-scale (<200 pc) jet. The dust emission is unlikely to be dominant, as the mm-wave slope is generally flatter than expected. Also, due to no increase in the mm-wave luminosity with the Eddington ratio, a radiation-driven outflow model is possibly not the common mechanism. Furthermore, we find independence of the mm-wave luminosity on indicators of the inclination angle from the polar axis of the nuclear structure, which is inconsistent with a jet model whose luminosity depends only on the angle.

79 ASTRONOMY AND ASTROPHYSICS↗

A Unified Model of Cosmic-Ray Propagation and Radio Extreme Scattering Events from Intermittent Interstellar Structures

Intermittent magnetic structures are a plausible candidate for explaining cosmic-ray (CR) diffusion rates derived from observed CR energy spectra. Independently, studies of extreme scattering events (ESEs) of radio quasars and pulsar scintillation have hinted that very straight, large aspect ratio magnetic current sheets may be responsible for the localized large scattering of radio waves. The required shortest axis of the typical structures producing ESEs is of the same scale (∼au) as the gyroradii of ∼GeV CRs. In this Letter, we propose that the same magnetic/density sheets can produce large scattering of both CRs and radio waves. We demonstrate that the geometry and volume-filling factor of the sheets derived from quasar ESEs can explain the observed mean free path of GeV CRs without introducing free parameters. The model places constraints on the sheet geometry, such as straightness and large aspect ratio, and assumes that the statistics of the sheets are similar throughout the Galactic volume. We therefore discuss observational tests of the sheet model, which includes observations of echoes in pulsars and fast radio bursts, gravitationally lensed quasars, the distribution of ESE durations, and spatial correlations between ESE events and rotation measure fluctuations. Such tests will be enabled by upcoming wide-field radio instruments, including the Canadian Hydrogen Observatory and Radio-transient Detector and Deep Synoptic Array 2000 Antennas.

Kempski, Philipp [Princeton Univ., NJ (United Stat↗

Low power and privacy preserving sensor platform for occupancy detection

A low-cost, low-power, stand-alone sensor platform having a visible-range camera sensor, a thermopile array, a microphone, a motion sensor, and a microprocessor that is configured to perform occupancy detection and counting while preserving the privacy of occupants. The platform is programmed to extract shape/texture from images in spatial domain; motion from video in time domain; and audio features in frequency domain. Embedded binarized neural networks are used for efficient object of interest detection. The platform is also programmed with advanced fusion algorithms for multiple sensor modalities addressing dependent sensor observations. The platform may be deployed for (i) residential use in detecting occupants for autonomously controlling building systems, such as HVAC and lighting systems, to provide energy savings, (ii) security and surveillance, such as to detect loitering and surveil places of interest, (iii) analyzing customer behavior and flows, (iv) identifying high performing stores by retailers.

Velipasalar, Senem↗

Spatially resolved absolute quantitation in thin tissue by mass spectrometry

Mass spectrometry (MS) has become the de facto tool for routine quantitative analysis of biomolecules. MS is increasingly being used to reveal the spatial distribution of proteins, metabolites, and pharmaceuticals in tissue and interest in this area has led to a number of novel spatially resolved MS technologies. Most spatially resolved MS measurements are qualitative in nature due to a myriad of potential biases, such as sample heterogeneity, sampling artifacts, and ionization effects. As applications of spatially resolved MS in the pharmacological and clinical fields increase, demand has become high for quantitative MS imaging and profiling data. As a result, several varied technologies now exist that provide differing levels of spatial and quantitative information. Furthermore, this review provides an overview of MS profiling and imaging technologies that have demonstrated quantitative analysis from tissue. Focus is given on the fundamental processes affecting quantitative analysis in an array of MS imaging and profiling technologies and methods to address these biases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗