Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectrum analyzers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

The abundance of CH3D in the atmosphere of Titan, derived from 8- to 14-micron thermal emission

The 8.6-micron emission feature of Titan's infrared spectrum was analyzed using the Voyager temperature-pressure profile. Although both C3H8 and CH3D have bands at that wavelength, it is shown that CH3D dominates the observed emission on Titan. A CH3D/CH4 mixing ratio is derived using this band and the strong CH4 band at 7.7 microns. The corresponding D/H ratio is 4.2(+2 -1.5) x 10 to the -4th, neglecting deuterium fractionation with other molecules. The main uncertainty in this value comes from the continuum emission characteristics. The D/H ratio is apparently significantly enhanced on Titan with respect to published values for Saturn.

Kim, S. J.↗

An Analysis of the High Frequency Vibrations in Early Thematic Mapper Scenes

The potential effects of high frequency vibrations on the final Thematic Mapper (TM) image are evaluated for 26 scenes. The angular displacements of the TM detectors from their nominal pointing directions as measured by the TM Angular Displacement Sensor (ADS) and the spacecraft Dry Rotor Inertial Reference Unit (DRIRU) give data on the along scan and cross scan high frequency vibrations present in each scan of a scene. These measurements are to find the maximum overlap and underlap between successive scans, and to analyze the spectrum of the high frequency vibrations acting on the detectors. The Fourier spectrum of the along scan and cross scan vibrations for each scene also evaluated. The spectra of the scenes examined indicate that the high frequency vibrations arise primarily from the motion of the TM and MSS mirrors, and that their amplitudes are well within expected ranges.

Kogut, J.↗

Overcash, D. R.

The objectives of this investigation were to determine the characteristics of semiconductor devices at low temperatures. The output characteristics of several currently available semiconductor devices and devices fabricated at Marshall Space Flight Center were measured over a range of gate voltages. Large variations in low-temperature performance, not only from type to type, but from field effect transistor (FET) to FET of the same type were obtained. By increasing the carrier concentrations at low temperatures through extra heavy doping, metal oxide semiconductor field effect transistor (MOSFET) device was fabricated that operated at 4.2K. To verify the low-temperature operation of a heavily doped device, this procedure was repeated. Their noise spectrum was analyzed at 4.2K. Suggestions were made as to possible fabrication methods, techniques, and other semiconductor materials that might improve the device charactersitics at low temperatures. A procedure for using an electric field to drift dopants through the insulating oxide to produce a very thin, heavily doped region under the gate of a MOSFET was initiated. Capacitance s a function of voltage plots was suggested as a method for determining the level of dopant drift.

Source record↗

The use of a numerical filter to correct airborne temperature measurements for the effects of sensor lag

A numerical filter for transforming measured temperature signals into a close approximation of the actual temperature signal is described. The filter is derived by minimizing the mean-square error of the system, and assuming a knowledge of the characteristics of the sensing element and its housing. The equation representing the frequency-response function of the numerical filter is given. Input and output spectra for a filter applied to a case with negligible noise and a noise level of 1.5 percent of the total power in the input spectrum are analyzed, and the numerical weights for these two cases are calculated. Phase angle and gain for the entire system are examined. It is noted that the filter can enhance spectral components as high as 8 Hz with little phase and gain degradation over the bandwidth.

Ritter, John A.↗

Fiber-linked interferometric pressure sensor

A fiber-optic pressure sensor is described which uses a diaphragm to modulate the mirror separation of a Fabry-Perot cavity (the sensing cavity). A multimode optical fiber delivers broadband light to the sensing cavity and returns the spectrally modulated light which the cavity reflects. The sensor's output spectrum is analyzed using a tunable Fabry-Perot cavity (the reference cavity) to determine the mismatch in the mirror separations of the two cavities. An electronic servo control uses this result to cause the mirror separation of the reference cavity to equal that of the sensing cavity. The displacement of the pressure-sensing diaphragm is then obtained by measuring the capacitance of the reference cavity's metal-coated mirrors. Relative to other fiber-optic sensors, an important advantage of this instrument is its high immunity to the effects of variations in both the transmissivity of the fiber link and the wavelength of the optical source.

Beheim, G.↗

Physical properties of asteroids from radar observations

The basic experimental strategies of asteroid radar astronomy are summarized and new information based on recent radar observations about asteroid surface properties is presented. Particular attention is given to the use of radar techniques for constraining asteroid shapes and pole directions. The geometric relationship between a rotating asteroid and its radar echo power spectrum is analyzed.

Ostro, S. J.↗

Model atmospheres for SN 1987A and the distance to the Large Magellanic Cloud

A code which simultaneously solves the non-LTE equations of statistical equilibrium and the time-independent equation of radiation transport in an expanding atmosphere is applied to analyze the spectrum of SN 1987A. The behavior of a model atmosphere in which the density structure is a power-law function of radius has been studied and compared closely with SN 1987A data. This model atmosphere is used to derive corrections to the expanding photosphere method for determining distances to supernovae. The distance to the Large Magellanic Cloud derived from SN 1987A observations by this 'custom yardstick' is 49 + or - 6 kpc in excellent accord with results for RR Lyrae stars and for Cepheids. This empirical test of the expanding photosphere method provides the basis for hope that it may make a significant contribution to the extragalactic distance scale at cosmologically interesting distances.

Eastman, Ronald G.↗

The microwave spectrum of the AlO radical

The rotational spectrum of the aluminum monoxide radical in the ground electronic state X 2Sigma(+) was observed in the millimeter- and submillimeter-wave region. Aluminum monoxide radicals were generated directly in a flow reactor absorption cell by the reaction of N2O with aluminum vaporized from a high-temperature crucible. The observed spectrum was analyzed to yield molecular constants including the rotational constant, centrifugal distortion constant, spin-rotation interaction constant, magnetic hyperfine interaction constants, and nuclear quadrupole coupling constant.

Yamada, Chikashi↗

Investigations on atomic-vapor-filter high-spectral-resolution lidar for temperature measurements

The temperature measurement by the analysis of Rayleigh scattered laser radiation with atomic vapor filters is investigated in both theory and laboratory experiments. Synthetic air is irradiated with a cw dye laser at 283 nano-meters, and the backscattered spectrum is analyzed with two lead vapor cells in one oven. Temperature measurements are carried out, and the effect of different parameters on the accuracy is investigated. Important aspects for the realization of a lidar are given.

Voss, E.↗

X-ray spectroscopy of the super soft source RXJ0925.7-475

The super soft source (SSS) RXJ 0925.7-475 was observed with the Advanced Satellite for Cosmology and Astrophysics (ASCA) solid state spectrometer and its energy spectrum was analyzed. A simple black body model does not fit the data, and several absorption edges of ionized heavy elements are required. Without the addition of absorption edges, the best-fit black body radius and the estimated bolometric luminosity are 6800 (d/1 kpc) km and 1.2 x 10(exp 37) (d/1 kps)(exp 2) erg/s, respectively. The introduction of absorption edges significantly reduces the best-fit radius and luminosity to 140 (d/1 KPS) km and 6 x 10(exp 34) (d/1 kpc)(exp 2) erg/s, respectively. This suggests that the estimation of the emission region size and luminosity of SSS based on the black body model fit to the observed data is not reliable.

Ebisawa, Ken↗

Analysis of Cirrus Cloud Microphysical Data

The First International Satellite Cloud Climatology Regional Experiment (FIRE) program has the goal of improving our capabilities to understand, model and detect the properties of climatically-important clouds. This is being undertaken through a three-pronged effort of modeling, long-term observations and short-term intensive field studies. Through examination of satellite and other data it is apparent that stratus and cirrus cloud types have the greatest impact on climate due to their radiative effects and ubiquitous nature. As a result, the FIRE program has developed two paths of investigation, each having its own subset of research objectives and measurement programs. The work conducted under this grant was directed toward furthering our understanding of cirrus cloud systems. While it is known that cirrus are climatically important, the magnitude and even sign of the impact is unclear. Cirrus clouds affect the transfer of radiation according to their physical depth and location in the atmosphere and their microphysical composition. However, significant uncertainties still exist in how cirrus clouds form and how they are maintained, what their physical properties are and how they can be parameterized in numerical models. Better remote sensing techniques for monitoring cirrus cloud systems and improved modeling of radiative transfer through ice particles are also needed. A critical element in resolving these issues is a better understanding of cirrus cloud microphysical properties and how they vary. The focus of the research to be conducted under this grant was th data collected in situ by the University of North Dakota Citation aircraft. The goals of this research were to add to the body of knowledge of cirrus cloud microphysics, particularly at the small end of the size spectrum; and analyze the spatial variation of cirrus clouds.

Poellot, Michael R.↗

Stability and Heat Transfer Characteristics of Condensing Films

The overall objective of this research is to investigate the fundamental physics of film condensation in reduced gravity. The condensation of vapor on a cool surface is important in many engineering problems,including spacecraft thermal control and also the behavior of condensate films that may form on the interior surfaces of spacecraft. To examine the effects of body force on condensing films, two different geometries have been tested in the laboratory: (1) a stabilizing gravitational body force (+1g, or condensing surface facing 'upwards') and (2) de-stabilizing gravitational body force (-1g, or 'downwards'). For each geometry, different fluid configurations are employed to help isolate the fluid mechanical and thermal mechanisms operative in condensing films. The fluid configurations are (a) a condensing film, and (b) a non-condensing film with film growth by mass addition by through the plate surface. Condensation experiments are conducted in a test cell containing a cooled copper or brass plate with an exposed diameter of 12.7 cm. The metal surface is polished to allow for double-pass shadowgraph imaging, and the test surface is instrumented with imbedded heat transfer gauges and thermocouples. Representative shadowgraph images of a condensing, unstable (-1g) n-pentane film are shown. The interfacial disturbances associated with the de-stabilizing body force leading to droplet formation and break-off can be clearly seen. The heat transfer coefficient associated with the condensing film is shown. The heat transfer coefficient is seen to initially decrease, consistent with the increased thermal resistance due to layer growth. For sufficiently long time, a steady value of heat transfer is observed, accompanied by continuous droplet formation and break-off. The non-condensing cell consists of a stack of thin stainless steel disks 10 cm in diameter mounted in a brass enclosure. The disks are perforated with a regular pattern of 361 holes each 0.25 mm in diameter. Non-condensing experiments in -1g have employed 50 cSt and 125 cSt silicone oil pumped through the perforated disks at a specified rate by a syringe micropump. The time to droplet break-off and the disturbance wavelengths appear to decrease with increasing pumping rate. The ability to reliably perform multi-point, ultrasonic measurements of the film thickness has been demonstrated. A linear array of eight transducers of 6 mm diameter (with a beam footprint of comparable size) are pulsed with a square-wave signal at a frequency of 5 MHz and a pulse duration of approximately 0.3 s. For thin films (60 m to 2-3 mm in thickness) the layer thickness is determined by frequency analysis, where the received ultrasound pulse is Fourier transformed and the spacing between the peaks in the frequency spectrum is analyzed. For thicker layers (up to at least 1 cm in thickness), time-domain analysis is performed of the received ultrasound pulses to generate directly the layer thickness. A time-trace of the film thickness at a point using a single transducer in the linear array is shown for the case of an unstable (-1g) n-pentane film. The oscillations in film thickness are evidently due to the passage and/or shedding of droplets from the cooled plate surface. The entire transducer array was used to measure the changes in film thickness resulting from the passage of gravity waves generated either by an oscillating wall or the impact of a single droplet on the free surface of a film. The enclosure in both cases was 14 cm square and the transducer spacing was 12 mm. Best results were obtained using as test fluid a mixture of 50% glycerol and 50% water with a fluid layer thickness of 3-5 mm. In both cases the measured wavelengths and wave propagation speeds using the ultrasound technique compared reasonably well with those observed by optical imaging. Additional information can be found in the original extended abstract.

Hermanson, J. C.↗

On Certain Theoretical Developments Underlying the Hilbert-Huang Transform

One of the main traditional tools used in scientific and engineering data spectral analysis is the Fourier Integral Transform and its high performance digital equivalent - the Fast Fourier Transform (FFT). Both carry strong a-priori assumptions about the source data, such as being linear and stationary, and of satisfying the Dirichlet conditions. A recent development at the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC), known as the Hilbert-Huang Transform (HHT), proposes a novel approach to the solution for the nonlinear class of spectral analysis problems. Using a-posteriori data processing based on the Empirical Mode Decomposition (EMD) sifting process (algorithm), followed by the normalized Hilbert Transform of the decomposed data, the HHT allows spectral analysis of nonlinear and nonstationary data. The EMD sifting process results in a non-constrained decomposition of a source real-value data vector into a finite set of Intrinsic Mode Functions (IMF). These functions form a nearly orthogonal derived from the data (adaptive) basis. The IMFs can be further analyzed for spectrum content by using the classical Hilbert Transform. A new engineering spectral analysis tool using HHT has been developed at NASA GSFC, the HHT Data Processing System (HHT-DPS). As the HHT-DPS has been successfully used and commercialized, new applications pose additional questions about the theoretical basis behind the HHT and EMD algorithms. Why is the fastest changing component of a composite signal being sifted out first in the EMD sifting process? Why does the EMD sifting process seemingly converge and why does it converge rapidly? Does an IMF have a distinctive structure? Why are the IMFs nearly orthogonal? We address these questions and develop the initial theoretical background for the HHT. This will contribute to the development of new HHT processing options, such as real-time and 2-D processing using Field Programmable Gate Array (FPGA) computational resources,

Kizhner, Semion↗

The Abundance of Iron-Peak Elements and the Dust Composition in eta Carinae: Manganese

We study the chemical abundances of the Strontium Filament found in the ejecta of (eta) Carinae. In particular, we derive the abundances of iron-peak elements front spectra of their singly ionized ions present in the optical/IR spectra. In this paper we analyze the spectrum of Mn II using a new non-LTE model for this system. In constructing this models we carried out theoretical calculations of radiative transition rates and electron impact excitation rate coefficients. We find that relative to Ni the gas phase abundance ratio of Mn is roughly solar, similar to the Cr abundance but in contrast to the large enhancements in the abundances of Sc and Ti. NVe interpret this result as an indication of non-equilibrium condensation in the ejecta of (eta) Carinae.

Bautista, M. A.↗

Optical Design of the Extreme Coronagraph for Living Planetary Systems Instrument for the LUVOIR Mission Study

The large UV/optical/IR surveyor (LUVOIR) is a concept for a highly capable, multiwavelength space observatory with ambitious science goals. Finding and characterizing a wide range of exoplanets, including those that might be habitable, is a major goal of the study. The ambitious science goals drive the challenges of optical design. This paper will present how the optical design meets the unique challenges for coronagraphs on large telescopes to achieve high contrast for a wide wavelength range from 200 to 2000 nm. Some of these unique challenges include the position and size of occulter masks, deformable mirror placement and separation, tight tolerances on the optical system and each element, and finally, packaging all instruments in a limited space. Three types of modules are designed after the coronagraph to explore the exoplanets and analyze the spectrum of detected exoplanet signals: two imaging cameras, two integral field spectrographs, and one high-resolution spectrometer. All of them work together to provide information to meet scientific challenges in searching for habitable planets. The optical designs, unique challenges, and the solutions for all coronagraph and spectral modules are presented. Their specifications derived from science goals are also presented.

Qian Gong↗

Optical design of the Extreme Coronagraph for Living Planetary Systems instrument for the LUVOIR mission study

The large UV/optical/IR surveyor (LUVOIR) is a concept for a highly capable, multiwavelength space observatory with ambitious science goals. Finding and characterizing a wide range of exoplanets, including those that might be habitable, is a major goal of the study. The ambitious science goals drive the challenges of optical design. This paper will present how the optical design meets the unique challenges for coronagraphs on large telescopes to achieve high contrast for a wide wavelength range from 200 to 2000 nm. Some of these unique challenges include the position and size of occulter masks, deformable mirror placement and separation, tight tolerances on the optical system and each element, and finally, packaging all instruments in a limited space. Three types of modules are designed after the coronagraph to explore the exoplanets and analyze the spectrum of detected exoplanet signals: two imaging cameras, two integral field spectrographs, and one high-resolution spectrometer. All of them work together to provide information to meet scientific challenges in searching for habitable planets. The optical designs, unique challenges, and the solutions for all coronagraph and spectral modules are presented. Their specifications derived from science goals are also presented.

Qian Gong↗

Brillouin Asymmetric Spatial Heterodyne Oceanographic Lidar Receiver for Profiling Temperature, Salinity, and Sound Velocity

No sensor today is capable of remotely sensing temperature and salinity at depth in oceanic waters, yet the physics to do so exists. Blue-green light (450-550 nm) can penetrate 10’s of meters into the water and interacts with water by the Brillouin scatter process. Temperature and salinity can be determined by analyzing the spectrum of Brillouin scatter. A host of scientific and operational drivers exist for such a sensor, from improved hurricane and red tide forecasting to studies of ocean fronts, eddies, and freshwater lenses. A low flying airborne light detection and ranging (lidar) instrument concept that exploits this physics is presented, along with simulation tools that potential data users can use to model its measurement performance, determine suitability for their application, and assess its implications.

John Anthony Smith↗