Search NASA⌕ Search

SEARCH · Search NASA

Results for “storage tank”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Evaluation of Design Concepts for Collapsible Cryogenic Storage Vessels

Future long-duration missions to Mars using in situ resource production to obtain oxygen from the Martian atmosphere for use as a propellant or for life support will require long term oxygen storage facilities. This report describes preliminary analysis of design concepts for lightweight, collapsible liquid oxygen storage tanks to be used on the surface of Mars. With storage at relatively low pressures, an inflatable tank concept in which the cryogen is stored within a fiber-reinforced Teflon FEP bladder is an efficient approach. The technology required for such a tank is well-developed through similar previous applications in positive expulsion bladders for zero-g liquid fuel rocket tanks and inflatable space habitat technology, though the liquid oxygen environment presents unique challenges. The weight of the proposed structure is largely dominated by the support structure needed to hold the tank off the ground and permit a vacuum insulation space to be maintained around the tank. In addition to the inflatable tank concept, telescoping tank concepts are studied. For a telescoping tank, the greatest difficulty is in making effective joints and seals. The use of shape memory alloy to produce a passive clamping ring is evaluated. Although the telescoping tank concepts are a viable option, it appears that inflatable tank concepts will be more efficient and are recommended.

Fleming, David C.↗

Solar hot water system installed at Days Inn Motel, Jacksonville, Florida

The solar system was designed to provide 65 percent of the hot water demand. Water in the liquid flat plate collector (900 square feet) system automatically drains into the 1000 gallon lined and vented steel storage tank when the pump is not running. Heat is transferred from storage to Domestic Hot Water (DHW) tanks through a tube and shell heat exchanger. A circulating pump between the DHW tanks and heat exchanger enables solar heated water to help make up DHW standby losses. All pumps are controlled by differential temperature.

Source record↗

Developing NDE Techniques for Large Cryogenic Tanks

The Shuttle and Constellation Programs require very large cryogenic ground storage tanks in which to store liquid oxygen and hydrogen. The existing LC-39 pad tanks, which will be passed onto Constellation, are 40 years old and have received minimal refurbishment or even inspection, because they can only be temperature cycled a few times before being overhauled (a costly operation in both time and dollars). Numerous questions exist on the performance and reliability of these old tanks which could cause a major Program schedule disruption. Consequently, with the passing of the first two tanks to Constellation to occur this year, there is growing awareness that NDE is needed to detect problems early in these tanks so that corrective actions can be scheduled when least disruptive. Time series thermal images of two sides of the Pad B LH2 tank have been taken over multiple days to demonstrate the effects of environmental conditions to the solar heating of the tank and therefore the effectiveness of thermal imaging.

Parker, Don↗

Solar space and water heating system installed at Charlottesville, Virginia

The solar energy system located at David C. Wilson Neuropsychiatric Hospital, Charlottesville, Virginia, is described. The solar energy system consists of 88 single glazed, Sunworks 'Solector' copper base plate collector modules, hot water coils in the hot air ducts, a Domestic Hot Water (DHW) preheat tank, a 3,000 gallon concrete urethane insulated storage tank and other miscellaneous components. Extracts from the site files, specifications, drawings, installation, operation and maintenance instructions are included.

Source record↗

Validation of a Two-Phase CFD Model for Predicting Propellant Tank Pressurization and Pressure Collapse in The Ground-Based K-Site Hydrogen Slosh Experiment

A two-phase CFD model for tank pressurization and following sloshing in a cryogenic storage tank partially filled with liquid hydrogen is presented using the Volume-Of-Fluid approach for representing the phase boundary and the associated interfacial heat, mass and momentum transfer between the liquid and the vapor regions. The CFD model was validated against pressurization and sloshing data for a 62 cubic foot tank provided by Moran et al. Cases with different sloshing amplitudes and frequencies are studied. The results of modeling tank pressurization are presented first followed by the results of sloshing cases. Predicted tank pressures are compared with the experimental data.

Computational Fluid Dynamics↗

Validation of a Two-Phase CFD Model for Predicting Propellant Tank Pressurization and Pressure Collapse in the Ground-Based K-Site Hydrogen Slosh Experiment

A two-phase CFD model for tank pressurization and following sloshing in a cryogenic storage tank partially filled with liquid hydrogen is presented using the Volume-Of-Fluid approach for representing the phase boundary and the associated interfacial heat, mass and momentum transfer between the liquid and the vapor regions. The CFD model was validated against pressurization and sloshing data for a 62 cubic foot tank provided by Moran et al. Cases with different sloshing amplitudes and frequencies are studied. The results of modeling tank pressurization are presented first followed by the results of sloshing cases. Predicted tank pressures are compared with the experimental data.

Computational Fluid Dynamics↗

A Transient Hydrodynamic Model of Screen Channel Liquid Acquisition Devices for In-Space Cryogenic Propellant Management

Screen channel liquid acquisition devices (LADs) will play a crucial role in future deep space travel. It is essential that vapor-free delivery of propellants during tank-to-tank transfer is ensured to maximize yield from storage tanks and prevent potential combustion instabilities. The screen channel LAD utilizes a fine screen wire mesh that can separate phases in a low Bond number (i.e. microgravity) environment using surface tension forces. This study presents the development and verification of a new model for transient screen compliance, one of the influential factors for screen channel LAD design. Screen compliance is crucial during LAD channel outflow transients because the slight deflection of the screen can provide needed mass to satisfy rapid outflow demands and reduce the pressure difference across the screen. The model is successfully verified against CFD simulations. In addition, the characteristic speed for the governing screen compliance equations is derived which allows for numerical stability criteria to be established. As shown in this study, the transient maximum pressure difference across the screen can greatly exceed the steady state maximum pressure difference across the screen in many cases.

Hydrodynamics Simulations↗

Numerical modeling and parametric study of a dual purpose underground thermal battery

We report integrating thermal energy storage with building energy systems can enable flexible building electric demands at buildings to help mitigate the mismatch between electricity supply and demand. A novel building heating and cooling system that integrates a dual-source heat pump with hybrid thermal storage named dual-purpose underground thermal battery (DPUTB) has been developed for reshaping building electric demands. The proposed DPUTB integrated geothermal heat pump system is an original innovation that enables Grid-interactive Energy Efficient buildings. This paper focuses on the study of the novel DPUTB. The DPUTB works as both a thermal storage tank (an inner tank) and a ground heat exchanger (an outer tank separated from the inner tank by the insulation material). High fidelity and computationally effective models are needed to predict the performance of the novel DPUTB. This study has developed a simplified dynamic model for the DPUTB according to heat transfer and energy conservation principles and validated it by using experimental data obtained from testing a small-scale DPUTB apparatus. A parametric study was conducted to identify a design that can achieve the target thermal storage performance of load shift and energy efficiency. The parametric study results show that the inner tank shell thermal conductivity and the phase change material's melting point are the two most influencing factors on the performance of the DPUTB. One single full-size DPUTB with the identified design could provide 1-ton cooling (3.51 kW) with the supply temperature lower than 11 °C for 4 hours in summer after being fully charged in 8 hours. The inner tank filled with phase change material is for cooling thermal storage as a latent tank in the design. However, its capacity can be as high as 60 MJ as a sensible water tank for heating storage in winter. In the future study, the DPUTB model will be incorporated into the dual-source heat pump system for evaluating the overall system performance of demand side management in the long term.

25 ENERGY STORAGE↗

Developing NDE Techniques for Large Cryogenic Tanks - Year 2 Report

The Shuttle Program requires very large cryogenic ground storage tanks in which to store liquid oxygen and hydrogen. The existing Launch Complex-39 Pad tanks, which will be passed onto future launch programs, are over 40 years old and have received minimal refurbishment and only external inspections over the years. The majority of the structure is inaccessible without a full system drain of cryogenic liquid and insulation in the annular region. It was previously thought that there was a limit to the number of temperature cycles that the tanks could handle due to possible insulation compaction before undergoing a costly and time consuming complete overhaul; therefore the tanks were not drained and performance issues with these tanks, specifically the Pad B LH2 tank, were accepted. There is a need and an opportunity, as the Shuttle program ends and work to upgrade the launch pad progresses, to develop innovative non-destructive evaluation (NDE) techniques to analyze the current tanks. Techniques are desired that can aid in determining the extent of refurbishment required to keep the tanks in service for another 20+ years. A non-destructive technique would also be a significant aid in acceptance testing of new and refurbished tanks, saving significant time and money, if corrective actions can be taken before cryogen is introduced to the systems. Year one of this project concentrated on analysis of the current tanks located at LC-39 while cryogen was present. Year two of this project concentrated on analysis of detectable thermal variations on the outer surface of the tanks as the cryogen was drained and the inner vessel warmed to ambient conditions. Two techniques have been deployed in the field to monitor the tank. The first consisted of a displacement sensor to monitor for any expansions at the base of the tank during warm-up that could indicate a compaction issue with the insulation. The second technique was continued thermal monitoring of the tank through and after warm up. The indications noted in the thermal images were compared to bore-scope images of the annular region taken once the tank was inert and warmed to ambient conditions. Similar thermal imaging was performed on a smaller tank where an insulation void was induced to compare the effectiveness of thermal imagining on a different tank geometry.

Arens, Ellen↗

Helium Conservation by Diffusion Limited Purging of Liquid Hydrogen Tanks

Recently, the new 1.2-million-gallon liquid hydrogen (LH 2 ) storage tank at the Kennedy Space Center Launch Complex 39 was purged, replacing nitrogen with helium, using a piston purge process. This purging approach had been used on Space Shuttle External Tanks (ET) in the past, but not on one of the large LH 2 tanks. The result was a huge success, potentially saving more than 1 million cubic feet of helium and significant labor. To better understand this result, a diffusion-based purge model was developed. The model predictions accurately match the helium concentration data, providing understanding of the helium savings and suggesting how to better optimize the purging of this large tank for future operations. The model was then applied to the piston purging of the Space Shuttle ETs, showing that these purges were not optimal, but that the amount of wasted helium was not excessive and that additional helium might have been saved by small changes to the process. The Space Shuttle Program (SSP) has ended, but these results are applicable to the purging of future large cylindrical LH 2 tanks. Finally, data have been obtained on inerting the Space Launch System (SLS) Core Stage (CS) LH 2 tank, replacing hydrogen with helium after an aborted launch. This is a more complicated case, but the model predicts that substantial helium might be saved by modifying the current purging process.

Helium Conservation↗

Modeling Droplet Heat and Mass Transfer during Spray Bar Pressure Control of the Multipurpose Hydrogen Test Bed (MHTB) Tank in Normal Gravity

A CFD model for simulating pressure control in cryogenic storage tanks through the injection of a subcooled liquid into the ullage is presented and applied to the 1g MHTB spray bar cooling experiments. An Eulerian-Lagrangian approach is utilized to track the spray droplets and capture the interaction between the discrete droplets and the continuous ullage phase. The spray model is coupled with the VOF model by performing particle tracking in the ullage, removing particles from the ullage when they reach the interface, and then adding their contributions to the liquid. A new model for calculating the droplet-ullage heat and mass transfer is developed. In this model, a droplet is allowed to warm up to the saturation temperature corresponding to the ullage vapor pressure, after which it evaporates while remaining at the saturation temperature. The droplet model is validated against the results of the MHTB spray-bar cooling experiments with 50% and 90% tank fill ratios. The predictions of the present T-sat based model are compared with those of a previously developed kinetic-based droplet mass transfer model. The predictions of the two models regarding the evolving tank pressure and temperature distributions, as well as the droplets' trajectories and temperatures, are examined and compared in detail. Finally, the ullage pressure and local vapor and liquid temperature evolutions are validated against the corresponding data provided by the MHTB spray bar mixing experiment.

mass transfer↗

CFD Modeling of Tank Pressurization and Axial Jet Mixing Experiments with and without Non-Condensable Gas in the Ullage

A two-phase CFD model for tank pressurization and following jet mixing of a cryogenic storage tank is presented using VOF approach for representing the phase boundary and the associated interfacial heat, mass and momentum transfer between the liquid and vapor regions. The CFD model was validated against pressurization and liquid jet mixing data for a 110-inch diameter tank provided by Bullard1. Cases with like-gas and non-condensable gas pressurization are studied. The results of the cases with like-gas pressurization and following mixing are presented first, focusing on the effects of turbulence at the vapor-liquid interface on the tank pressure and phase change rates predictions. The second part of this paper is devoted to testing and validating the CFD model against non-condensable gas pressurization and following mixing. Tank pressures predicted in both cases are compared with each other and with the experimental data.

Computational Fluid Dynamics↗

CFD Modeling of Tank Pressurization and Axial Jet Mixing Experiments with and without Non-Condensable Gas in the Ullage

A two-phase CFD model for tank pressurization and following jet mixing of a cryogenic storage tank is presented using VOF approach for representing the phase boundary and the associated interfacial heat, mass and momentum transfer between the liquid and vapor regions. The CFD model was validated against pressurization and liquid jet mixing data for a 110-inch diameter tank provided by Bullard. Cases with like-gas and non-condensable gas pressurization are studied. The results of the cases with like-gas pressurization and following mixing are presented first, focusing on the effects of turbulence at the vapor-liquid interface on the tank pressure and phase change rates predictions. The second part of this paper is devoted to testing and validating the CFD model against non-condensable gas pressurization and following mixing. Tank pressures predicted in both cases are compared with each other and with the experimental data.

Computational Fluid Dynamics↗

Validation of a Two-Phase CFD Model for Autogenous Pressurization and Expulsion

This paper presents a two-phase CFD model for tank pressurization and expulsion in a liquid hydrogen cryogenic storage tank. The model uses a Volume-of-Fluid approach combined with the Kinetics-based Schrage equation to capture the phase boundary and the associated interfacial heat, mass, and momentum transfer between the liquid and vapor regions. The CFD model is validated against expulsion data from the NASA K-Site tank experiment. Predicted tank pressures, temperatures, and pressurant requirements are compared with the experimental data to demonstrate the model’s accuracy.

Autogenous Pressurization↗

Thermography to Inspect Insulation of Large Cryogenic Tanks

Thermography has been used in the past to monitor active, large, cryogenic storage tanks. This approach proposes to use thermography to monitor new or refurbished tanks, prior to filling with cryogenic liquid, to look for insulation voids. Thermography may provide significant cost and schedule savings if voids can be detected early before a tank is returned to service.

Arens, Ellen↗

Hanford Tank Vapors in Worker Breathing Zones - Source, Dispersion, and Receptor Data - 20373

A wide range of organic and inorganic chemicals from historical Hanford Site processes are now stored in 177 underground storage tanks at the Hanford tank farms. Workers at the Hanford tank farms have expressed concerns about chemical vapor exposures for many years. During the spring of 2014, worker reports of chemical odors and/or symptoms prompted the development of the Savannah River National Laboratory Hanford Tank Vapor Assessment Team (TVAT) and their resulting independent assessment and recommendations concerning tank farm worker reports of vapors. The Tank Vapor Assessment report included a hypothesis that 'vapors coming out of tanks in high concentration (bolus) plumes sporadically intersected with the breathing zones of workers, resulting in brief but intense exposures to some workers.' The focus of this effort is to present current knowledge to describe the mechanisms by which workers may experience short duration vapor concentrations above background in the tank farms environment. The TVAT hypothesis that workers have experienced concentrations approaching 80% of the tank headspace up to 3 meters (10 feet) from tank sources is not supported by sampling data or modeling results. Modeling indicates that concentrations are quickly reduced from the source, and that the upper end of predicted concentrations at worker breathing zones are a factor of 10 or more lower than source concentrations. Area measurements corroborate the fact that worker breathing zone concentrations are 10 to 100 times lower than source concentrations, and events with elevated concentrations are rare. These reduced vapor concentration levels may result in detectable odors or irritation, depending on a worker's specific odor threshold and sensitivity to the chemical species. Short-duration vapor events may be mitigated by evaluating daily atmospheric conditions in conjunction with planned tank farm activities. Monitoring changing conditions related to tank vapors concentrations at the source and within worker breathing zone is also an important step to protect workers from short duration elevated concentration events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stabilizing the Grid and Reducing Utility Bills Through Price-Responsive Controls for Heat Pump Water Heaters

The electricity grid is facing increasing challenges in cost-effectively balancing supply and demand. These challenges are exacerbated by increased penetration of photovoltaics, which causes mid-day overproduction, and electrification of gas appliances, which increases peak-period electricity demand. Decarbonization requires shifting building loads from fossil-intensive high-cost times to renewable-intensive low-cost times while maintaining quality of service to occupants. Utilities and ISO’s are investigating new ways of incentivizing this load shifting. One promising method is the use of Highly Dynamic Prices (HDPs). HDPs feature continuously changing prices that reflect real-time grid generation and distribution costs and capacity constraints, and thus incentivize consumers to shift their loads. California’s CPUC CalFUSE proposal and Hawaii’s recent changes demonstrate that electricity tariffs are moving towards this model. For this to work however, loads must have the capability to respond to these prices. Heat pump water heaters (HPWHs) are an ideal device for this purpose because their storage tanks decouple delivery of domestic hot water from electricity consumption. The storage enables control strategies that consume midday solar power to increase the energy stored in the tank, then provide evening peak domestic hot water services using the stored energy. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls for many flexible loads - including HPWHs - in response to HDP. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of the on-board controller in a residential, integrated HPWH . The price-responsive controls a) shift load in ways that consume additional midday solar power to help stabilize the grid and reduce overall emissions, b) ensure that occupants receive equal or better hot water delivery service, and c) minimize the operating cost for each home in the fleet. On the grid level, the resulting shift will reduce utility operating costs and emissions, and can avoid expensive system capacity expansions. The control approach is customized to each home based on typical hot water consumption patterns. HPWH controllers, whether on the device or remotely, will receive a schedule of CTA-2045-B signals or set temperature adjustments customized to the current HDP price schedule and home. Simulation results for a fleet of 148 HPWHs on a summer day in Berkeley, California show cost savings of 29% and high price electricity consumption reductions of 80%, while maintaining full quality of service.

24 POWER TRANSMISSION AND DISTRIBUTION↗