Search NASA⌕ Search

SEARCH · Search NASA

Results for “system verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Non-Nuclear Test Facility Development to Support Verification and Validation Needs

This study focuses on developing a non-nuclear test facility to help meet the verification and validation (V&V) requirements of a water-cooled small modular reactor (SMR) system. The scaling analysis necessary for reactor system experimentation and assessment model V&V considers various reactor system accident scenarios such as main steam line break (MSLB), steam generator tube rupture (SGTR), and containment condensation and heat transfer. The goal is to identify key physics based phenomena of interest (POI), specific figures of merit (FOMs), and the state of knowledge (SOK) by employing phenomena identification and ranking table (PIRT) studies. Important physics phenomena such as heat transfer, fluid dynamics, structural integrity, and material selection must be addressed when scaling a thermal-hydraulics system. Alongside these considerations, modifications to the facility may be needed to align the scaled system with the available footprint (height and space) of the facility. These modifications may include infrastructure upgrades, changes to the piping layout, implementation of safety measures, and installation of new instrumentation and control systems. The test facility aims to provide a scaled-down version of prototypic facilities for comprehensive V&V activities by overcoming these challenges and making the necessary modifications. This approach minimizes scaling distortion, simulates prototypic plant conditions, and accurately models accident event progressions. Thus, the facility will be capable of adequately modeling a scaled SMR system to support the design, development and licensing needs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of a Portable In Situ Phosphorous Sensor

While phosphorus is a critical nutrient for all forms of life, runoff leads to phosphorus accumulation in surface water where it can cause a variety of health, environmental, and economic problems. The Department of Energy is interested in conducting long-term field experiments to monitor the impact of phosphorus in terrestrial and aquatic environments, and to better understand a cost vs. benefit analysis of reducing phosphorus pollution. Performing such long-term experiments requires affordable sensors capable of monitoring low-level phosphorus concentrations under challenging environmental conditions. However, such sensors are currently not available. The goal of this proposed project is to develop and demonstrate a low-cost portable phosphorus sensor suitable for in situ measurements. We will determine the technical requirements for a Raman-based sensor system, design and build a signal amplifier, integrate it with a Raman-based sensor, and demonstrate a proof-of-concept level sensor system. The expected accomplishments for Phase I include the identification of the technical requirements of a combined Raman laser/spectrometer and cavity enhancement system, building a proof-of-concept level sensor system capable of detecting orthophosphate compounds at the desired level of 0.25 mg P/L and organic P compounds, and verification of the sensor performance under laboratory and field conditions. In addition, we will identify initial hardening requirements that will need to be implemented during Phase II. While we plan to develop an integrated sensor system for monitoring phosphorus, the cavity-based enhancement system can also be used in combination with other (non-phosphorus) Raman sensors that we plan to develop or that are already commercially available. A recent market report highlights the increasing demand for such environmental monitoring applications, with the market for chemical detection anticipated to grow at a compound annual growth rate of 6.5% (2020-2025). Wide-spread monitoring of phosphorus could reduce the damage from eutrophication in freshwater, which is estimated to be $2.2 billion annually, thereby increasing biodiversity, reducing costs required for drinking water treatment, and decreasing economic losses related to recreation and angling and lake property values.

54 ENVIRONMENTAL SCIENCES↗

Pre-Commercial Scale-Up of a Gas-Fired Absorption Heat Pump

The project sought to advance the maturity of SMTI’s 80 kBTU/hr residential space and water heating GAHP from the engineering prototype stage (TRL-7) to pre-production readiness by addressing manufacturing, balance of system design and installation, cost, reliability, and field application questions. As part of this project, the project team has: (1) Matured the design package for a commercially ready product (2) Demonstrated compliance with relevant ANSI standards (3) Completed manufacturing and assembly process specifications (4) Completed total production cost estimates and capital equipment requirements (5) Initiated component and system level reliability assessments (6) Completed a small field demonstration including measured performance, installation requirements and expected costs, and customer/key stakeholder feedback. (7) Completed a Techno-economic analysis for representative applications and climate zones, including justification for utility incentive programs. (8) Completed a market intelligence report. Scope of Work: A multi-faceted project was completed that included: (a) design for manufacturing tasks for both the sealed system and balance of system, (b) development and trial of key manufacturing processes and techniques, (c) evaluation of component and system level reliability, (d) exploration of make/buy decisions including impact on cost and required capital. Additionally, (e) installation and monitoring of a small number of field test units was completed to demonstrate energy savings and collect customer/installer feedback, and (f) a focused market research task was completed to explore potential barriers and improve market introduction plans. These tasks addressed many of the remaining technical risks regarding long-term reliability, verification of manufacturing cost estimates and identification of cost concerns, identify installation and balance of system design criteria necessary to achieve energy savings and installed cost goals, and identify market barriers and strategies prior to product market introduction.

03 NATURAL GAS↗

Evaluation of integrated daylighting and electric lighting design projects: Lessons learned from international case studies

This article presents and discusses the lessons learned from the monitoring of 25 integrated daylighting and electric lighting international case study projects. The case studies consist of real occupied buildings that have been monitored as part of the International Energy Agency (IEA) SHC Task 61/EBC Annex 77 Programme. The general goal of the case studies was to balance lighting energy use with occupants’ visual and non-visual requirements. This was achieved using innovative solutions for daylighting and electric lighting with advanced controls, but also implementing simple and out-of-the-box strategies. The findings suggest that energy demands for lighting can significantly be reduced by combining sensible daylight provision, efficient lighting sources, and advances in controls. Yet, the effective achievement of project goals requires adequate monitoring, fine-tuning, and verification. The findings also suggest that the adoption of “integrative” lighting – that is, lighting systems that address both visual and non-visual responses – is getting increasingly popular. Catering to non-visual requirements will likely drive further innovation in lighting technology. Currently, there is limited investment available for developing daylighting systems for integrative lighting, and the current related electric strategies often come at the risk of energy rebound effects. Overall, providing daylighting and understanding user requirements are fundamental steps towards achieving quality projects, with potential benefits beyond saving energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Controller Verification of a Smart-Grid Compatible 200 kHz Single-stage Photovoltaic Microinverter

This paper presents control system design, implementation, and experimental validation of a single-stage 400 W, 200 kHz solar photovoltaic (PV) microinverter using hardware-in-the-loop (HIL) and hardware testing. The selected circuit topology is based on a Gallium Nitride (GaN) direct-matrix based dual active bridge (DAB) converter with a low voltage active power decoupler (APD) circuit. Control performance is verified, smart-grid compatibility is tested, and circuit operation is confirmed. Controller HIL (CHIL) is shown to aid in a complex power electronics system design by 1) enabling detailed control development prior to hardware implementation, 2) expanding the use of automated testing, and 3) increasing confidence in control performance prior to prototype testing. Altogether, these factors make HIL a valuable tool in complex power electronic designs.

14 SOLAR ENERGY↗

Energy-Efficient Driving in Connected Corridors via Minimum Principle Control: Vehicle-in-the-Loop Experimental Verification in Mixed Fleets

Connected and automated vehicles (CAVs) can plan and actuate control that explicitly considers performance, system safety, and actuation constraints in a manner more efficient than their human-driven counterparts. In particular, eco-driving is enabled through connected exchange of information from signalized corridors that share their upcoming signal phase and timing (SPaT). This is accomplished in the proposed control approach, which follows first principles to plan a free-flow acceleration-optimal trajectory through green traffic light intervals by Pontryagin's Minimum Principle in a feedback manner. Urban conditions are then imposed from exogeneous traffic comprised of a mixture of human-driven vehicles (HVs) - as well as other CAVs. As such, safe disturbance compensation is achieved by implementing a model predictive controller (MPC) to anticipate and avoid collisions by issuing braking commands as necessary. The control strategy is experimentally vetted through vehicle-in-the-loop (VIL) of a prototype CAV that is embedded into a virtual traffic corridor realized through microsimulation. Up to 36% fuel savings are measured with the proposed control approach over a human-modelled driver, and it was found connectivity in the automation approach improved fuel economy by up to 26% over automation without. Additionally, the passive energy benefits realizable for human drivers when driving behind downstream CAVs are measured, showing up to 22% fuel savings in a HV when driving behind a small penetration of connectivity-enabled automated vehicles.

33 ADVANCED PROPULSION SYSTEMS↗

Verification and Validation of Spectral Element Code for Supercritical CO2 Flow in Vertical Heated Tubes

The investigation of heat transfer in supercritical CO2 (sCO2) has garnered considerable attention in recent decades, given sCO2's potential as a promising working fluid for advanced power conversion cycles. Despite previous research efforts, there are still gaps in our understanding of sCO2 heat transfer, particularly in conditions associated with heat transfer deterioration. To delve into sCO2 heat transfer more comprehensively, we propose employing the high-fidelity computational fluid dynamics code NekRS to simulate sCO2 flow using the large eddy simulation technique. Through graphics processing unit acceleration, NekRS achieves a higher computational speed than traditional CPU-based systems. However, before using NekRS in practical applications involving sCO2, it is imperative to perform verification and validation. Here, this paper presents our efforts to verify and validate the NekRS code's capability for simulating sCO2 using heated vertical tubes, where heat transfer deterioration usually happens. To accommodate the unique properties of sCO2, we have modified the NekRS code by integrating third-party property modules, such as REFPROP and PROPATH. Our simulations are compared with experimental and numerical data from the literature, instilling confidence in leveraging NekRS for future engineering applications. Our simulations also reveal that the accuracy of the property module significantly impacts the results, with REFPROP outperforming PROPATH for sCO2 properties. Additionally, we observed that, depending on the flow direction, buoyancy can either enhance or suppress turbulence in sCO2 flow. In upward flow, under certain conditions, the suppressed turbulence leads to heat transfer deterioration, resulting in elevated wall temperatures.

NekRS↗

Theorems in Service of Sound Composition, Rapid Modeling and Scalable Analysis

This project extends the state of the art in formal verification modeling with modules and automatically checkable data-sharing patterns such that component modules can retain their assurance case when composed within a larger system. For users, smaller models make reasoning easier and help to ensure they accurately reflect text specifications. For automated methods, smaller models give exponential benefits for verification algorithm execution time.

97 MATHEMATICS AND COMPUTING↗

FAST-1.2 User Installation and Verification Guide: Developed Under NQA-1-2017

The purpose of this document is to provide the user information about the installation of Fuel Analysis for Steady state and Transient (FAST)-1.2 on their computers or servers. General information about the code and supported operating systems is described in Section 1.0. Self-service oriented FAST-1.2 software licensing steps are described in Section 2.0. An installation verification test suite is provided with FAST-1.2 and described in Section 3.0. A convenience script for converting Fuel Rod Analysis Program – Constant (FRAPCON) to FAST inputs is discussed in Section 4.0. FAST-1.2 was developed and released under a software quality assurance program based upon NQA-1-2017 at Pacific Northwest National Laboratory (PNNL). FAST-1.2 is the latest baseline code. The installation verification test suite contains both steady state and transient Anticipated Operation Occurrences (AOOs), accident conditions, such as Reactivity Initiated Accidents (RIAs) and Loss of Coolant Accidents (LOCAs).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Portable and Cost-Effective Device for Reliable Detection of Counterfeit and Non-compliant Refrigerants in Diverse Applications

Counterfeit refrigerants pose significant challenges to safety, system reliability, and operational effectiveness due to their harmful contaminants or incompatible chemical compositions. Utilizing these noncompliant products can lead to reduced efficiency, equipment failures, and expensive repairs. Additionally, heightened demand for alternative refrigerants during the industry's transition has created supply gaps, enabling counterfeit products to proliferate. Accurate detection and analysis tools are therefore essential to verify refrigerant authenticity and ensure system integrity in diverse applications. This paper presents the development of a portable device designed for reliable identification and detailed analysis of refrigerant composition. By integrating precision gas sampling, controlled pressure regulation, and automated sensor technology, the device not only detects deviations from standard refrigerant properties but also provides a comprehensive composition breakdown. Pre-calibrated sensors measure the refrigerant gas to identify specific concentrations and contaminants, with an intuitive LED-based indicator system ensuring quick interpretation of results. The user-friendly interface enables operators to select refrigerant types for targeted testing, further enhancing accuracy and usability for field technicians. Comprehensive testing was conducted on mildly flammable A2L refrigerants, showcasing the device’s robustness and adaptability in analyzing composition and detecting discrepancies. The device demonstrated consistent accuracy across a range of refrigerant samples, affirming its reliability in diverse operational environments. Its design minimizes contamination risks during sampling and provides detailed composition results within 90 seconds, ensuring efficient and precise analysis. With a projected price point under $150, the proposed solution delivers affordability alongside its lightweight portability and straightforward operation. Unlike complex and costly alternatives, such as gas chromatography systems, this device provides an accessible option for technicians, customs personnel, and industry operators in need of quick and effective refrigerant verification. Compatible with both current formulations and emerging refrigerant technologies, the device addresses critical counterfeit detection needs across a range of applications. By delivering accurate composition analysis and counterfeit identification, this innovation enhances system performance, safety, and operational reliability in crucial industries.

Cheekatamarla, Praveen [ORNL] (ORCID:0000000248827↗

Verification, Validation, and Calibration Through a Causal Lens

While typical validation and verification approaches focus on identifying the associations between data elements using statistical and machine learning methods, the novel methods in this paper focus instead on identifying causal relationships between data elements. Statistical and machine-learning-based approaches are strictly data-driven, meaning that they provide quantitative comparison measures between data sets without explicitly considering the hypotheses behind them. This can lead to the erroneous conclusion that, if two data sets are close enough, the models that generated them are similar. In addition, when experimental and simulated data differ to an extent that fails to meet the acceptance criteria, calibration techniques are used to tweak simulation model parameters to reduce the gap between the two types of data. This produces the false expectation that a simulation model will match reality. The methods presented in this paper move away from these strictly data-driven methods for validation and calibration toward more robust, model-driven methods based on causal inference. Causal inference aims to identify the possible mechanisms that might have generated data. Thus, this analysis targets the prediction of the effects when one (or more) of the identified mechanisms are altered. There are many approaches to identify, quantify, and illustrate causal relationships. For the scope of this paper, directed graphs are employed as causal models. If the directed graph lacks cycles, it is known as a directed acyclic graph. A node in such a graph represents an observed data element while a directed edge connecting two nodes represents a causal relationship between two variables. The developed causal methods are designed to extract causal models from simulation models and experimental data. Causal models capture the causal relationships between data elements (e.g., simulated and experimental data). In this context, validation and verification are performed by comparing causal models. The proposed approach does not only inform system analysts on how a simulation model matches real-world data, but also identifies elements of the simulation model that should be revised when discrepancies between simulation and experimental data are observed. Through these causal methods, analysts can identify the portion of the model equation(s) that are behind an edge connecting two variables. Hence, once the structural differences between causal models have been determined, model calibration can occur by changing only those model parameters that impact the identified causal relationships.

97 MATHEMATICS AND COMPUTING↗

VALIDATION, VERIFICATION, AND CALIBRATION THROUGH A CAUSAL LENS

This paper presents an alternative method based on causal inference to perform validation, verification, and calibration of simulation models. While classical validation and verification approaches focus on the identification of the associations between data elements using statistical and machine learning methods, the novel methods in this paper focus instead on the identification of causal relationships between data elements. Statistical and machine learning-based approaches are strictly data-driven, meaning that they provide quantitative comparison measures between datasets without explicitly considering the hypotheses behind them. This can lead to the erroneous conclusion that, if two data sets are close enough, then the models that generated them are similar. In addition, when experimental and simulated data differ to an extent that fails to meet the acceptance criteria, calibration techniques are used to tweak simulation model parameters to reduce the gap between the two types of data. This produces the false expectation that a simulation model will match reality. The methods presented in this paper move away from these strictly data-driven methods for validation and calibration toward more robust, model-driven methods based on causal inference. Causal inference aims to identify the possible mechanisms that might have generated data. Thus, this analysis targets the prediction of the effects when one (or more) of the identified mechanisms are altered. There are many approaches to identify, quantify and illustrate causal relationships. For the scope of this paper, directed graphs are employed as causal models. If the directed graph lacks cycles it is known as a directed acyclic graph (DAG). A node in such a graph represents an observed data element while a directed edge connecting two nodes represents a causal relationship between two variables. The developed causal methods are designed to extract causal models from simulation models and from experimental data. Causal models capture the causal relationships between data elements (e.g., simulated and experimental data). In this context, validation and verification are performed by comparing causal models. The proposed approach does not only inform system analysts on how a simulation model matches real-world data, but also identifies elements of the simulation model that should be revised when discrepancies between simulation and experimental data are observed. Through these causal methods, analysts have a means to identify the portion of the model equation(s) that are behind an edge connecting two variables. Hence, once the structural differences between causal models have been determined, model calibration can occur by changing only those model parameters that impact the identified causal relationships.

97 MATHEMATICS AND COMPUTING↗

Crossover from 2D Ferromagnetic Insulator to Wide Band Gap Quantum Anomalous Hall Insulator in Ultrathin MnBi 2 Te 4

Intrinsic magnetic topological insulators offer low disorder and large magnetic band gaps for robust magnetic topological phases operating at higher temperatures. By controlling the layer thickness, emergent phenomena such as the quantum anomalous Hall (QAH) effect and axion insulator phases have been realized. Furthermore, these observations occur at temperatures significantly lower than the Néel temperature of bulk MnBi 2 Te 4 , and measurement of the magnetic energy gap at the Dirac point in ultrathin MnBi 2 Te 4 has yet to be achieved. Critical to achieving the promise of this system is a direct measurement of the layer-dependent energy gap and verification of a temperature-dependent topological phase transition from a large band gap QAH insulator to a gapless TI paramagnetic phase. Here we utilize temperature-dependent angle-resolved photoemission spectroscopy to study epitaxial ultrathin MnBi 2 Te 4 . We directly observe a layer-dependent crossover from a 2D ferromagnetic insulator with a band gap greater than 780 meV in one septuple layer (1 SL) to a QAH insulator with a large energy gap (>70 meV) at 8 K in 3 and 5 SL MnBi 2 Te 4 . The QAH gap is confirmed to be magnetic in origin, as it becomes gapless with increasing temperature above 8 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Revisiting “Additional Carbon”: Tracking Atmosphere–Ecosystem Carbon Exchange to Establish Mitigation and Negative Emissions From Bio-Based Systems

Climate stabilization plans rely heavily on advanced bioenergy and bioproducts for substitution of fossil-based energy sources and materials, and increasingly, for negative emissions via the direct sequestration of biogenic carbon. Yet, there remain persistent, largely unresolved critiques of bioenergy assessment methodology, particularly in the areas of land use and biogenic carbon accounting. The concept of “additional carbon” calls for evaluating the climate performance of bio-based systems by whether feedstock production creates measurable new local agro-ecosystem uptake of carbon from the atmosphere. This concept is challenging to operationalize for first-generation biofuels, and has largely been advanced as a negative critique. However, carbon additionality is more straightforward to establish—and less critical to overall system mitigation performance—in advanced bioenergy systems. In this Perspective, I review the additional carbon critique, and why it is analytically challenging to address in first-generation biofuel systems based on conventional food crops with large existing markets. Next, I make a case that carbon additionality (1) is more readily achievable with cellulosic feedstocks, (2) is more directly observable for dedicated biomass crops, and (3) is not a strict requirement for achieving net mitigation in carbon-negative bio-based systems. I end by discussing how centering atmosphere–ecosystem carbon exchanges in bio-based system assessment could create new opportunities for enterprise-scale performance monitoring and verification, augmenting and diversifying the current reliance on model-based life-cycle assessment approaches.

54 ENVIRONMENTAL SCIENCES↗

Zero power experiment for molten salt reactor - code verification and validation request

Molten Salt Reactors (MSRs) are one of the six perspective Generation IV nuclear technologies that should fulfil sustainability, economics, safety, and proliferation resistance goals. In recent years these concepts have attracted increased interest in research as well as in industry. In the context of developing new, innovative technology, a zero-power experiment would be an ideal option for improving the understanding of MSR systems under low-risk and low-cost conditions. The given research was focused on cross-verification of the nuclear codes for MSR modelling and simulations as required for the development of the first design of a potential facility and a draft of an experimental programme. The analysis included the evaluation of lattice and Monte Carlo codes. The study showed that all considered nuclear tools were in good agreement with each other. Although this does not mean the results will match the real experimental data, which is essential for the regulatory approval of a novel technology. Currently, experimental data is almost absent for MSR technology. Hence, a zero power experiment is needed to assure we can rely on modelling and simulation studies for further development of MSR technology and deliver real-world experiments to support the licensing of future MSRs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

In anaerobic reactors the microbial community structure depends on feed type, with no “keystone” species tied to COD removal

Two-stage anaerobic digestion (AD) systems provide treatment for high strength wastewater with high stability and performance. Encapsulation technology can intensify AD to facilitate the separation of the solids retention time from the hydraulic retention time (HRT), offering lower HRTs, smaller reactors, and high effluent quality. To support successful deployment, however, the encapsulated community must contain all the needed microorganisms for successful treatment and be flexible enough to treat a variety of wastewaters. Here, a two-stage system was investigated in which microbial cultures were enriched on various high-strength wastewaters in suspended flow-through systems to determine how feed type influenced performance and microbial community structure. The hypothesis was that specific genera, or so-called “keystone species” would positively correlate to organic carbon degradation for a given feed, enabling construction of a well-functioning community for encapsulation. Results showed that the number of total bacteria (as 16S rRNA gene copies) did not correlate to soluble chemical oxygen demand (sCOD) removal, indicating that the community structure and/or members were important for good performance. Results also showed that feed type strongly influenced carbon removal and microbial community structure for 1st-stage fermenting communities, but not 2nd-stage methanogenic communities. In this study, the “core” community members were defined as organisms common to all of either the 1st- or 2nd-stage reactors irrespective of the feed they received and were present in at least 50% of the samples throughout the entire experiment. “Unique” community members were specific to a single feed, and hence, only present in either the 1st- or 2nd-stage reactors receiving that feed. In both 1st- and 2nd-stage communities, only one core genera and no unique genera were positively and significantly correlated to sCOD removal. Verification experiments performed with encapsulated communities showed that organisms identified in flow-through system and correlated with carbon degradation, though not significantly, seemed to be important for performance. Our results suggest that one cannot construct a community containing specific populations in lieu of enrichment. Nevertheless, a single diverse encapsulated anaerobic community should provide good (>80%) carbon removal when fed a variety of influents, if time is provided for enrichment after deployment.

54 ENVIRONMENTAL SCIENCES↗