Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Simultaneous Temperature/Pressure Monitoring in Compressible Flows using Hybrid fs/ps Pure-Rotational CARS

We demonstrate simultaneous monitoring of temperature and pressure using a hybrid femtosecond/picosecond pure-rotational CARS technique in a one-dimensional line-imaging configuration. The method employs two detection channels and two 60-ps-duration probe laser beams with independently adjustable time delays from the broadband 35-fs pump/Stokes pulse. Simultaneous temperature and pressure monitoring is demonstrated along the centerline of a canonical under expanded compressible air jet flow emanating from a choked, sonic nozzle. Temperature is measured almost independently of pressure by analyzing CARS spectra obtained with a probe pulse near zero time delay for nearly collision-free acquisition. Pressure is obtained from spectra acquired with long probe time delays to sample the impact of gas-phase collisions. The CARS measurements were obtained in both time-averaged and single-laser-shot mode with 67 μm spatial resolution along the jet axis along a nominally 6-mm line. The measurements span a temperature and pressure range of T= 70-300 K and P= 0.05-1.2atm.

Sean P Kearney↗

A metal-ceramic coaxial cable with multipoint Fabry-Pérot interferometers for monitoring distributed high temperature

A metal ceramic coaxial cable (MCCC) sensor containing multiple Fabry-Pérot interferometers (FPIs) has been designed, fabricated, and evaluated for measuring distributed high temperatures. The MCCC sensor demonstrated here consists of stainless steel tube and wire conductors, alumina tube insulator, and three pairs of air gap reflectors distributed along the cable. The multipoint sensor operation is realized by the joint time-frequency domain technique, which combines the functions of time-domain reflectometry and frequency division multiplexing to enable the measurement of spatially distributed temperature. The 3-point MCCC-FPI sensor has been demonstrated for distributed temperature measurements between 250 and 550 °C and operability up to 1000 °C. The sensor offers high sensitivity of >0.18 MHz/°C with a measurement resolution of 1 Hz and reasonably small high temperature measurement error range of ±3 °C.

42 ENGINEERING↗

Enhanced Design of Radiation Tolerant High-Temperature Structural Health Monitoring Sensors

Acoustic emission sensors are vital in the nuclear industry for real-time structural health monitoring and early detection of material degradation. By capturing high-frequency stress waves emitted from defects like cracks, corrosion, or fatigue, acoustic emission sensors enable non-invasive monitoring of critical components such as reactor vessels, piping, and containment structures. This technology supports predictive maintenance, enhances safety, and ensures regulatory compliance by providing early warnings of potential failures. It is also instrumental in research, particularly in material testing reactors, where it is used to monitor the behavior of fuels and materials under irradiation, by allowing the detection of cracking or other acoustic signals in real time. This enables the evaluation of performance and accident behavior of advanced fuel concepts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Temperature controller for hyperthermia devices

Temperature controller monitors and controls temperature in local region of tumor. Medical grade thermocouples are inserted in or near tumor, controller pulse modulates radio frequency diathermy power source to maintain temperature within 0.2 C. System may be extended to control diathermy of more than one tumor or patient.

Couch, R. H.↗

Tire Temperature and Pressure Monitor

Wheel-mounted miniature transmitter would signal dangerous conditions to the driver or pilot. Monitor would include a sensor and a radio transmitter mounted so as not to imbalance the wheel. Sensor and batteries are enclosed in a plastic housing on the rim. Also has possibilities as a research tool for experiements on vehicle safety.

Macconochie, I. O.↗

Precise monitoring of global temperature trends from satellites

Passive microwave radiometry from satellites provides more precise atmospheric temperature information than that obtained from the relatively sparse distribution of thermometers over the earth's surface. Accurate global atmospheric temperature estimates are needed for detection of possible greenhouse warming, evaluation of computer models of climate change, and for understanding important factors in the climate system. Analysis of the first 10 years (1979 to 1988) of satellite measurements of lower atmospheric temperature changes reveals a monthly precision of 0.01 C, large temperature variability on time scales from weeks to several years, but no obvious trend for the 10-year period. The warmest years, in descending order, were 1987, 1988, 1983, and 1980. The years 1984, 1985, and 1986 were the coolest.

Spencer, Roy W.↗

Modulated FT- Raman Fiber-Optic Spectroscopy: A technique for Remotely Monitoring High-Temperature Reactions in Real-Time

A modification to a commercial FT-Raman spectrometer is presented for the elimination of thermal backgrounds in FT-Raman spectra. The modification involves the use of a mechanical chopper to modulate the CW laser, remote collection of the signal via fiber optics, and connection of a dual-phase digital signal processor lock-in amplifier between the detector and the spectrometer's collection electronics to demodulate and filter the optical signals. The resulting modulated FT-Raman fiber-optic spectrometer is capable of completely eliminating thermal backgrounds at temperatures exceeding 370 C. In addition, the signal/noise of generated Raman spectra is greater than for spectra collected with the conventional FT-Raman under identical conditions and incident laser power. This is true for both room-temperature and hot samples. The method allows collection of data using preexisting spectrometer software. The total cost of the modification (excluding fiber optics) is approximately $3000 and requires less than 2 h to implement. This is the first report of Fr-Raman spectra collected at temperatures in excess of 300 C in the absence of thermal backgrounds.

Cooper, John B.↗

Method of making a distributed optical fiber sensor having enhanced Rayleigh scattering and enhanced temperature stability, and monitoring systems employing same

A method of making an optical fiber sensor device for distributed sensing includes generating a laser beam comprising a plurality of ultrafast pulses, and focusing the laser beam into a core of an optical fiber to form a nanograting structure within the core, wherein the nanograting structure includes a plurality of spaced nanograting elements each extending substantially parallel to a longitudinal axis of optical fiber. Also, an optical fiber sensor device for distributed sensing includes an optical fiber having a longitudinal axis, a core, and a nanograting structure within the core, wherein the nanograting structure includes a plurality of spaced nanograting elements each extending substantially parallel to the longitudinal axis of the optical fiber. Also, a distributed sensing method and system and an energy production system that employs such an optical fiber sensor device.

42 ENGINEERING↗

Method of making a distributed optical fiber sensor having enhanced Rayleigh scattering and enhanced temperature stability, and monitoring systems employing same

A method of making an optical fiber sensor device for distributed sensing includes generating a laser beam comprising a plurality of ultrafast pulses, and focusing the laser beam into a core of an optical fiber to form a nanograting structure within the core, wherein the nanograting structure includes a plurality of spaced nanograting elements each extending substantially parallel to a longitudinal axis of optical fiber. Also, an optical fiber sensor device for distributed sensing includes an optical fiber having a longitudinal axis, a core, and a nanograting structure within the core, wherein the nanograting structure includes a plurality of spaced nanograting elements each extending substantially parallel to the longitudinal axis of the optical fiber. Also, a distributed sensing method and system and an energy production system that employs such an optical fiber sensor device.

Chen, Peng Kevin↗

Tracking the harmonic response of magnetically-soft sensors for wireless temperature, stress, and corrosive monitoring

This paper describes the application of magnetically-soft ribbon-like sensors for measurement of temperature and stress, as well as corrosive monitoring, based upon changes in the amplitudes of the higher-order harmonics generated by the sensors in response to a magnetic interrogation signal. The sensors operate independently of mass loading, and so can be placed or rigidly embedded inside nonmetallic, opaque structures such as concrete or plastic. The passive harmonic-based sensor is remotely monitored through a single coplanar interrogation and detection coil. Effects due to the relative location of the sensor are eliminated by tracking harmonic amplitude ratios, thereby, enabling wide area monitoring. The wireless, passive, mass loading independent nature of the described sensor platform makes it ideally suited for long-term structural monitoring applications, such as measurement of temperature and stress inside concrete structures. A theoretical model is presented to explain the origin and behavior of the higher-order harmonics in response to temperature and stress. c2002 Elsevier Science B.V. All rights reserved.

Non-NASA Center↗