Vulcan Test Platform: Demonstrating the Data Center as a Flexible Grid Asset

Explosive data center demand is outpacing grid infrastructure development. AI workloads and hyperscale cloud growth are creating unprecedented power requirements, while traditional grid expansion faces multi-year development timelines, regulatory hurdles, and decarbonization challenges. Sidewalk Infrastructure Partners recognized this impending crisis years ago and founded Verrus to develop an innovative solution: data centers that function as grid assets rather than passive loads. The Verrus approach integrates proprietary grid-aware controls with battery energy storage systems (BESS) in a medium-voltage architecture that delivers three critical capabilities: Fast-responding demand flexibility that can service requests from the utility within 10 seconds, Uninterrupted transition to islanded operation during grid disturbances, Continuous uptime assurance while maintaining all customer service level commitments Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), we validated these capabilities on Vulcan, a 70 MW utility-scale test platform powered by NREL's ARIES Virtual Emulation Environment. This deployment-ready technology has successfully demonstrated that Verrus data centers can deliver meaningful grid services while maintaining mission-critical reliability. This technical report outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can play a pivotal role in enhancing grid flexibility and reliability, without sacrificing service level guarantees.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EGS Collab Experiment 2: Microseismic Monitoring

This dataset contains continuous seismic waveform data recorded during stimulation and thermal circulation tests for the Enhanced Geothermal Systems (EGS) Collab Experiment #2, conducted from February to September 2022 at the Sanford Underground Research Facility in Lead, South Dakota. This experiment aimed to study and validate models of geothermal systems by injecting high-pressure fluids into rock formations 1200-1500 meters below the surface, inducing microseismic events. The seismic monitoring system included 16 three-component accelerometers and a 24-channel hydrophone array, installed in boreholes surrounding the test area. Data were recorded at high sampling rates using a continuous waveform recording system to monitor seismic activity in real time. The dataset contains the raw data stored in binary format, with files named based on timestamps, and includes calibration certificates for some sensors to facilitate corrections to real units. Users are strongly advised to consult the accompanying detailed report, which outlines the experimental setup, sensor specifications, installation procedures, and data processing methods. The report also describes important nuances, such as the hardware filters on hydrophones, sensor calibration details, and the naming conventions for the recorded data. Proper use of this dataset may require familiarity with seismic data analysis tools, such as the Obspy Python package, and an understanding of the SEED naming conventions used for channel identification.

15 GEOTHERMAL ENERGY↗

CMB lensing and Ly⁢ α forest cross bispectrum from DESI’s first-year quasar sample

The squeezed cross-bispectrum B κ,Ly α between the gravitational lensing in the cosmic microwave background and the 1D Ly α forest power spectrum can constrain bias parameters and break degeneracies between σ8 and other cosmological parameters. We detect B κ,Ly ⁢α with 4.8⁢σ significance at an effective redshift z eff =2.4 using Planck PR3 lensing map and over 280,000 quasar spectra from the Dark Energy Spectroscopic Instrument’s first-year data. We test our measurement against metal contamination and foregrounds such as Galactic extinction and clusters of galaxies by deprojecting the thermal Sunyaev-Zeldovich effect. Finally, we compare our results to a tree-level perturbation theory calculation and find reasonable agreement between the model and measurement.

79 ASTRONOMY AND ASTROPHYSICS↗

Building a Simplistic Automatic Extruder: Instrument Development Opportunities for the Laboratory

This work presents an automatic extruder as a research experience for undergraduate students. The system offers a user-friendly approach to preparing vesicles, such as liposomes or polymersomes, with a defined size and polydispersity properties crucial for research in biology and macromolecules. It comprises two syringe pumps connected by a membrane filter. The setup is controlled by software. Compared to manual extrusion, this automated system provides advantages, such as precisely controlled variables. The project describes a tool to enhance undergraduate learning in science and engineering laboratories. Building an automatic extruder serves as a simplified model of a complex industrial process. It offers a clear advantage: automating a well-understood manual extrusion process. To make this project accessible, it is broken down into three manageable tasks: software development, hardware assembly, and testing procedures. This breakdown describes the software created, the hardware components used, and the testing procedures conducted for this project. All project data, including software code, testing data, and procedures, are freely available online. This allows undergraduate students to not only begin their own projects but also contribute to this educational instrument’s ongoing development.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Burnup Spent Fuel Data Project Sibling Pin Test Campaign Closeout Summary

The Used Fuel Disposition Campaign (UFDC) was established within the United States (U.S.) Department of Energy (DOE) Office of Nuclear Energy (NE) to conduct research and development (R&D) activities associated with storage, transportation, and disposal of used or spent nuclear fuel (UNF or SNF) and high-level radioactive waste.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Recent Metallic Fuel Data Recovery in FIPD

The Metallic Fuels Irradiation and Physics Database (FIPD) [1] is an organized collection of metallic fuel test pin data (U-xPu-yZr, = 0 ~ 28; y = 2 ~ 10) and documentation available to industry. FIPD mainly contains three types of data: (1) Fuel pin fabrication data, including fuel slug diameter, fuel slug length, cladding diameter, smear density, etc. (2) Fuel pin operation conditions, including axial distributions for power, temperatures, fluences, burnup, and isotopic densities, etc. and (3) Fuel pin post-irradiation examination (PIE) data, including fission gas release and gas chemistry, profilometry, and neutron radiography, etc. The operating conditions for pins with PIE data available in FIPD span significant ranges across key parameters. The fuel peak burnup extends from less than 5% up to 20 at%. The cladding peak temperature varies from about 490°C to 660°C. Finally, the cladding peak DPA shows a wide range from less than 5 to 120. These broad ranges reflect the diverse testing conditions and operational parameters captured in the available PIE data. More detail about FIPD can be found in ref. [2]. The database development is an ongoing effort covering metallic fuel experiments from the Experimental Breeder Reactor II (EBR-II) and the Fast Flux Test Facility (FFTF). As reported in the ref. [3, 4], most of the PIE data generated during the IFR program [5] has been collected, reviewed, processed, and integrated into FIPD. The most recently added PIE data can be found in ref. [4], which shows the collection of over 95% of the PIE data by the time of this paper. The recent improvements to the database are summarized in this paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Developing ML/AI Methods for High-Throughput Characterization of Multiple-Sensor Streams of Tokamak Dynamics for High-Speed Control (Final Report)

This project evaluated and developed new mathematical and algorithmic techniques capable of handling (in real-time) the growing amounts of data generated by modern fusion research. While existing numerical linear algebra (NLA) methods provide the backbone to classical data analysis and algorithms, these methods fundamentally do not port to distributed architectures nor do they allow low-latency data reduction for control. Motivated by the needs for modern fusion reactors, this project explored and implemented new numerical methods to characterize plasma dynamics, respond in real-time to discharge evolution, and to process massive-scale data accurately and rapidly more fully. This project links expertise in multiple-sensor diagnostics of tokamak plasma dynamics from Columbia University’s Plasma Physics Laboratory with expertise in massive-scale data reduction and extreme data control algorithms at Columbia University’s Data Science Institute. This interdisciplinary project (i) applied machine learning methods, (ii) implemented a properly-trained neural-network for very fast processing of high-speed plasma videography, and (ii) developed the applied mathematical methods, based on randomized-NLA (rNLA) routines, for data analysis, reduction, and real-time control. The Columbia University High Beta Tokamak-Extended Pulse (HBT-EP) facility provided data to test new algorithms and partnership with Columbia University's Data Sciences Institute evaluated the broader use of new algorithms for many challenging control applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TEAMER: Twin Ocean Power Wave Energy Converter Comprehensive Overview

These files collectively provide a comprehensive overview of the testing process, data analysis, and validation for the Twin Ocean Power device tested at the O.H. Hinsdale Wave Research Laboratory, supported by TEAMER funding. This resource includes an overview of power results for a series of 7 trials. The files included in this comprehensive overview include a comprehensive log sheet for each trial, a summary of all trials, and processing scripts for the raw data. It includes all raw data in .tsv and MATLAB compatible formats, an average power chart, angular velocity charts for each trial, trial metrics, and power output files. This resource includes images of the Twin Ocean Power Wave Energy Converter device components and movement during testing and video recordings of each trial.

16 TIDAL AND WAVE POWER↗

Validation and Verification of Python based Neutron Spectrum Unfolding Software

To validate and verify the python-based code (PySL), designed to replicate the programs used by STAYSL for Beam Correction Factor (BCF) and Self-Shielding Factor (SHIELD), a series of tests were performed. To test BCF a python script was written to generate a random flux history file and both versions of the code processed the data. The test verified matching values up to at least one decimal place, approximately 10,000 tests where run and each one passed. Isotopes began to fail the tests once neutron saturation was reached. To verify this the total time of exposure was varied the isotopes that failed were compared to a list of their half-lives. The test process for SHIELD was very similar but, in this case, the code began by producing an input file with varying thickness and device type/environment for the SHIELD input. The failure condition for this test was if any of the data points for an isotope had a difference above 3%. Approximately 40 of these tests were run and there were only 3 isotopes that had reoccurring failures but only 2% of their points were above the 3% difference. A visual comparison was conducted by plotting the results from both programs. Although the test failed, the differences between their values were minuscule, and the self-shielding factor’s shape was preserved when plotted. Next steps for this project will be validating and verifying the python-based SigPhi code and then reproducing and testing the least squares unfolding performed by STAYSL.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Solar Panel Anti-Soiling Evaluation (CRADA Final Report)

NREL and Pellucere Technologies, Inc. will cooperate to leverage NREL’s existing testing and data analysis capability to evaluate solar panel anti-soiling coating in both laboratory testing conditions and from actual solar array field data.

14 SOLAR ENERGY↗

Validation of Pronghorn for Natural-Circulation Molten Salt Loops

This paper presents the development and validation of a high-fidelity thermal-hydraulic model of a molten salt natural circulation flow loop, designed for integration within a digital twin framework. The study evaluates the performance of Idaho National Laboratory’s Pronghorn against experimental data from Texas A&M University Molten Salt Flow Loop (MSFL) four Hitec-salt test benchmark data. Natural circulation of high-Prandtl-number fluids exhibits complex, counter-intuitive flow patterns that make pointwise thermocouple readings unreliable. Experimental work at TAMU’s MSFL provides benchmark data, including flow visualization at a test-section and centerline steady-state temperature measurements along the loop. Validation includes four single-phase natural circulation test cases with Hitec salt. Key metrics include flow profile agreement and steady-state temperature accuracy. Pronghorn results for two-dimensional single-phase agree qualitatively with the experimental flow profile. This paper illustrates the importance of Computational Fluid Dynamics (CFD) in elucidating the behavior of high-Prandtl-number thermal-hydraulics, along with how misleading centerline temperature measurements can be. Pronghorn reproduces the axial and radial stratification that makes single thermocouple readings unreliable. Future research will focus on reduced-order modeling techniques to enable rapid simulation suitable for real-time digital twin applications. The validated cases provide a basis for developing reduced-order surrogates aimed at real-time digital-twin applications.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Value of Information App (Value of Information App for Binary Geothermal Decisions and Binary Geothermal Possibilities) (Negative/Positive) [SWR-25-15]

Code base to run Streamlit Value of Information App for binary decision with geothermal techno economics. An open-source VOI app that models binary decisions (e.g. do something (drill) or walk away (do nothing)) and binary geothermal scenarios (positive or negative) has been developed. Users can input their anticipated economic values (profits or losses) directly into the value matrix to represent all four combinations of these actions and geothermal possibilities. VOI in general requires probabilities to be assigned for “probability of success”, or probability of experiencing a positive geothermal scenario versus negative. The users of the App can toggle this probability of success both in the demo problem and in the Value of Imperfect Information problem. The VOI App allows users to upload their own labeled data to evaluate how well it allows them to distinguish between positive versus negative sites. We have been using IGNENIOUS data to test and demonstrate; industry members have prepared their own labeled data, and have present their examples from diverse use cases at a conference workshop. The VOI App is open to the public at: https://voigeothermalrising.streamlit.app

Trainor-Guitton, Whitney [National Renewable Energ↗

Descriptor: High Temporal Resolution Meteorological Data at Oak Ridge Reservation (ORR-HiResMet)

Access to continuous, quality assessed meteorological data is critical for understanding the climatology and atmospheric dynamics of a region. Research facilities like Oak Ridge National Laboratory (ORNL) rely on such data to assess site-specific climatology, model potential emissions, establish safety baselines, and prepare for emergency scenarios. To meet these needs, on-site towers at ORNL collect meteorological data at 15-minute and hourly intervals. However, data measurements from meteorological towers are affected by sensor sensitivity, degradation, lightning strikes, power fluctuations, glitching, and sensor failures, all of which can affect data quality. To address these challenges, we conducted a comprehensive quality assessment and processing of five years of meteorological data collected from ORNL at 15-minute intervals, including measurements of temperature, pressure, humidity, wind, and solar radiation. The time series of each variable was pre-processed and gap-filled using established meteorological data collection and cleaning techniques, i.e., the time series were subjected to structural standardization, data integrity testing, automated and manual outlier detection, and gap-filling. The data product and highly generalizable processing workflow developed in Python Jupyter notebooks are publicly accessible online. As a key contribution of this study, the evaluated 5-year data will be used to train atmospheric dispersion models that simulate dispersion dynamics across the complex ridge-and-valley topography of the Oak Ridge Reservation in East Tennessee.

Steckler, Morgan R. [Oak Ridge National Laboratory↗

Characterization of Most Promising Sequestration Formations in the Rocky Mountain Region

The project Characterization of Most Promising Sequestration Formations in the Rocky Mountain Region is one of 9 site characterization projects that were implemented as part of ARRA (American Recovery and Reinvestment Act). Data from this project was used to improve resolution of data in NATCARB in the area of study. Data related to this study has already been incorporated in NATCARB Atlas. The Rocky Mountain Carbon Capture and Storage (RMCCS) project investigated multiple geologic formations and characterized a local site on the Colorado Plateau for future CCS opportunities. The RMCCS project focused on the Cretaceous Dakota, Jurassic Entrada, and Pennsylvanian Weber Sandstones, the three largest regional formations. All formations in this project are potential CO2 storage resources for future power plants, natural gas processing plants, cement plants, and oil shale development projects. The area adjacent to Craig, Colorado, (Sand Wash Basin) was the area selected for detailed geologic characterization on the RMCCS project. The basin was selected in part because the geology can be extrapolated to other sites on the Colorado Plateau. Field mapping and seismic surveys were conducted to identify and evaluate the basin's structural configuration. A 9,745-foot deep characterization well was drilled to collect 131 feet of core and a suite of geophysical well log data. Petrophysical tests on samples of core were used to calibrate geophysical log data, which can be used to obtain storage resource estimates and evaluate associated uncertainty as well as simulate the hydrologic behavior of injected CO2. A detailed analysis of the primary formations (Dakota, Entrada and Weber sandstones) yielded a more accurate CO2 storage resource assessment for these formations within the Colorado Plateau; RMCCS estimates indicate a total CO2 storage resource of more than 38,000 million metric tons. The characterization of the Sand Wash Basin (2-D seismic surveys, multiple well logs and lithological, petrophysical and geochemical analyses) allowed for a detailed 3-D model to be constructed. The model served as the framework for analyses ranging from CO2 storage resource, injectivity, and subsurface flow to uncertainty estimates to evaluation of risk.

2-D seismic↗

Mnemosyne

SAND2024-08570O Mnemosyne is an interactive tool for finding, retrieving, and exploring information about U.S. nuclear tests documented in the National Nuclear Security Administration’s NV-209 report. It also acts as an information architecture and codebase for integrating additional information and computational tools related to these tests at the unclassified and classified levels. Users can search by any number of nuclear test attributes—name, yield range, altitude ranges, purpose of a test—and find all matching tests. Users can also retrieve specific test information published in NV-209. The tool displays geospatial and topological data about test location, and it provides an information architecture for storing additional contextual material, such as photographs. Mnemosyne provides a capability of interfacing with HYCHEM, Sandia's nuclear detonation optical waveform tool. The software is designed for use by government, academia, military, and research institutions. The software will likely be advanced to integrate seismic data and the nuclear detonation optical signal simulation code radCTH. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Fisher, Dustin↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗