Search NASA⌕ Search

SEARCH · Search NASA

Results for “texturization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Texture analysis of small renal cell carcinomas at MDCT for predicting relevant histologic and protein biomarkers

Purpose: To assess CT texture features of small renal cell carcinomas (≤ 4cm) for association with key pathologic features including protein biomarkers. Methods: Quantitative CT texture analysis (CTTA) of small renal cancers (≤ 4cm) was performed on non-contrast and portal venous phase abdominal MDCT scans with an ROI drawn at the largest cross-sectional diameter of the tumor using commercially available software. Texture parameters including mean pixel attenuation, the standard deviation (SD) of the pixel distribution histogram, entropy, the mean of positive pixels, the skewness (i.e., asymmetry) of the pixel histogram, kurtosis (i.e., peakness) of the pixel histogram, and the percentage of positive pixels were correlated with pathologic data from surgical resection, including histology and nuclear grade, as well as microarray analysis in a subset (n = 40) including Ki67 index, CRP, and neovascularization (CD105/CD31). Results: Portal venous phase images were available in 249 patients (105 women, 144 men; mean age, 56.7 years) with tumors ≤ 4cm (mean, median, range, ± SD; 2.66, 2.60, 0.3–4.0 ± 0.85 cm). CT texture features of standard deviation, mean of the positive pixels, and entropy of the pixel histogram were significantly associated with histologic cell type (clear vs. non-clear; p < 0.001). Entropy and mean of the positive pixels also showed an association with nuclear grade, although not statistically significant. In the microarray analysis subset, kurtosis of the pixel histogram was associated with CD105/CD31 (p = 0.05). SD also showed some association with CD 105 positivity (p = 0.02) and CAIX expression (p = 0.01). Non-contrast CT images were available in 174 patients (72 women, 102 men; mean age, 57.5 years). Although the association with histology was not as strong as on the portal venous phase, in the subset of patients with microarray data, SD was found to correlate with CRP (p = 0.08), kurtosis with CRP (p = 0.004), CD105/CD31 (p = 0.002), and with Ki 67 index (p < 0.001). Conclusion: CT texture features were significantly associated with important histopathologic features in small renal cancers. These non-invasive measures can be performed retrospectively and may provide useful information when determining follow-up and treatment of small renal cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MRI of pancreatic ductal adenocarcinoma: texture analysis of T2-weighted images for predicting long-term outcome

Purpose: To assess the association between T2-weighted imaging (T2WI) texture-analysis parameters and the pathological aggressiveness or long-term outcomes in pancreatic ductal adenocarcinoma (PDAC) patients. Methods: A total of 66 patients (mean age 65.3 ± 9.0 years) who underwent preoperative MRI followed by pancreatectomy for PDAC between 2013 and 2015 were included in this study. A radiologist performed a texture analysis twice on one axial image using commercial software. Differences in the tex parameters, according to pathological factors, were analyzed using a Student’s t test or an ANOVA with Tukey’s test. Univariate and multivariate Cox proportional hazards regression analyses were used to evaluate the association between tex parameters and recurrence-free survival (RFS) or overall survival (OS). Results: The mean follow-up time was 18.5 months, and there were 58 recurrences and 39 deaths. The mean of the positive pixel (MPP)-related factors was significantly lower in poorly differentiated tumors than in well-differentiated tumors as well as in cases with perineural invasion. The univariate Cox proportional hazards analysis showed a significant association between the tex parameters and RFS or OS. However, only tumor size was statistically significant after the multivariate analysis. Only tumor size and entropy with medium texture were significantly associated with OS after the multivariate analysis. Conclusions: Tumor size was a significant predictive factor for RFS and OS in PDAC patients. Although entropy with medium texture analysis was significantly associated with OS, there were also limitations in the texture analysis; thus, further study is necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tribological Properties of Surface-Textured and Plasma-Nitrided Pure Titanium Under Oil Lubrication Condition

Plasma nitriding was conducted as post-treatment for surface texture on pure titanium to obtain a continuous nitriding layer. Supersonic fine particles bombarding (SFPB) was carried out to prepare surface texture. The surface morphologies and chemical composition were analyzed using scanning electron microscope and energy disperse spectroscopy. The microstructures of modified layers were characterized by transmission electron microscope. The tribological properties of surface-textured and duplex-treated pure titanium under oil lubrication condition were systematically investigated in the ball-on-plate reciprocating mode. The effects of applied load and sliding velocity on the tribological behavior were analyzed. The results show that after duplex treatments, the grains size in modified layer becomes slightly larger, and hardness is obviously improved. Wear resistance of duplex-treated pure titanium is significantly improved referenced to untreated and surface-textured pure titanium, which is 3.22 times as much as untreated pure titanium and 2.15 times of that for surface-textured pure titanium, respectively.

36 MATERIALS SCIENCE↗

Influence of Laser Surface Texturing on Tribological Performance of Tool Steels

This paper deals with the influence of laser surface texturing on tribological performance of two different tool steels: (a) Böhler K100 produced by conventional production technology and (b) Böhler K390 Microclean{sup ®} produced by powder metallurgy. The surface of heat-treated tool steels was modified using three different texture patterns. Impact of laser surface texturing was analyzed after different treatments. Furthermore, selected samples were borided to evaluate the combined influence of laser surface texturing and boriding on tribological performance of surface-treated samples. The results show that boriding was not beneficial for wavy surface type, and the steel production technology had a certain influence on the spinning tool. The laser surface texturing had an effect on decreasing the coefficient of friction on the K100 tool steel; however, it did not influence the tribological performance of the K390 Microclean{sup ®} tool steel. Boriding process was efficient in decreasing the coefficient of friction for both steels. The low coefficient of friction values did not have a positive influence on the wear depth.

36 MATERIALS SCIENCE↗

Manipulating topological states by imprinting non-collinear spin textures

Topological magnetic states, such as chiral skyrmions, are of great scientific interest and show huge potential for novel spintronics applications, provided their topological charges can be fully controlled. So far skyrmionic textures have been observed in noncentrosymmetric crystalline materials with low symmetry and at low temperatures. We propose theoretically and demonstrate experimentally the design of spin textures with topological charge densities that can be tailored at ambient temperatures. Tuning the interlayer coupling in vertically stacked nanopatterned magnetic heterostructures, such as a model system of a Co/Pd multilayer coupled to Permalloy, the in-plane non-collinear spin texture of one layer can be imprinted into the out-of-plane magnetised material. We observe distinct spin textures, e.g. vortices, magnetic swirls with tunable opening angle, donut states and skyrmion core configurations. We show that applying a small magnetic field, a reliable switching between topologically distinct textures can be achieved at remanence

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Are you using the right probe molecules for assessing the textural properties of metal–organic frameworks?

Textural properties—such as the surface area, pore size distribution, and pore volume—are at the forefront of characterization for porous materials. Therefore, it is essential to accurately and reproducibly report a material's textural properties as they could ultimately dictate its applicability. This work aims to provide insightful and comprehensive studies of textural properties for a set of metal–organic frameworks (MOFs), a class of porous materials, using various gases to equip researchers in the field with a helpful guide and reference. Here, we selected a series of nine MOFs with different surface areas, pore sizes, shapes, and chemical environments to represent a wide range of materials. We probed the textural properties of these MOFs using traditional and distinctive gases: N 2 , Kr and O 2 at 77 K, Ar at 87 K, and CO 2 at 195 and 273 K. With regard to surface area, we discuss the validity and challenges associated with the current BET method, the importance of utilizing the Rouquerol et al. consistency criteria to ensure accuracy and reproducibility, and the recommended gas probes for certain materials. For pore size distribution, we discuss the efficacy of each probe for determining the pore sizes within a porous material relative to the calculated distribution from its crystal structure, the limitations of current computational kernels used to calculate pore size distributions, and the need for advanced kernels to envelope the diversity of porous materials. Finally, for pore volume, we discuss the use of the Gurvich rule to obtain the total pore volume in comparison with calculated values from crystal structures and its consistency as a metric for porous materials. Ultimately, we hope that this article will aid researchers in characterizing the textural properties of porous materials and encourage the development of new kernels capable of encompassing the complexity of MOFs and other porous materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correlation of critical current density to quasi-biaxial texture and grain boundary cleanliness in fully dense Bi-2212 wires

The distinctive quasi-biaxial texture of Bi 2 Sr 2 CaCu 2 O x (Bi-2212) plays an important role in enabling high critical current density ($J_c$) in Bi-2212 round wires (RWs). Here we studied three over pressure heat treated wires with $J_c$ varying by a factor of ~10, all being fully dense. Using electron backscatter diffraction, we observed the differences in biaxial texture in these three wires. Transmission electron microscopy also revealed differences in grain boundary (GB) cleanliness and connectivity. These analyses showed that high $J_c$ is unambiguously correlated to the best biaxial texture, which is in turn correlated to slow cooling from the liquid melt into solid Bi-2212. However, at 4.2 K, there is a negligible difference in intragrain pinning in the three wires, suggesting that the $J_c$ variation by a factor of ~10 is primarily due to variable filament and intergrain connectivity. In this work, the principal determinants of intergrain connectivity is the quasi-biaxial texture and GB cleanliness. Overall, $J_c$ optimization of the Bi-2212 RW is a complex multi-variable process, but this study shows that maximizing the biaxial texture quality is an important first step in such an optimization process.

36 MATERIALS SCIENCE↗

Texture analysis improves level set segmentation of the anterior abdominal wall

Purpose: The treatment of ventral hernias (VH) has been a challenging problem for medical care. Repair of these hernias is fraught with failure; recurrence rates ranging from 24% to 43% have been reported, even with the use of biocompatible mesh. Currently, computed tomography (CT) is used to guide intervention through expert, but qualitative, clinical judgments, notably, quantitative metrics based on image-processing are not used. The authors propose that image segmentation methods to capture the three-dimensional structure of the abdominal wall and its abnormalities will provide a foundation on which to measure geometric properties of hernias and surrounding tissues and, therefore, to optimize intervention.Methods: In this study with 20 clinically acquired CT scans on postoperative patients, the authors demonstrated a novel approach to geometric classification of the abdominal. The authors’ approach uses a texture analysis based on Gabor filters to extract feature vectors and follows a fuzzy c-means clustering method to estimate voxelwise probability memberships for eight clusters. The memberships estimated from the texture analysis are helpful to identify anatomical structures with inhomogeneous intensities. The membership was used to guide the level set evolution, as well as to derive an initial start close to the abdominal wall.Results: Segmentation results on abdominal walls were both quantitatively and qualitatively validated with surface errors based on manually labeled ground truth. Using texture, mean surface errors for the outer surface of the abdominal wall were less than 2 mm, with 91% of the outer surface less than 5 mm away from the manual tracings; errors were significantly greater (2–5 mm) for methods that did not use the texture.Conclusions: The authors’ approach establishes a baseline for characterizing the abdominal wall for improving VH care. Inherent texture patterns in CT scans are helpful to the tissue classification, and texture analysis can improve the level set segmentation around the abdominal region.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantum noise properties of CT images with anatomical textured backgrounds across reconstruction algorithms: FBP and SAFIRE

Purpose: Quantum noise properties of CT images are generally assessed using simple geometric phantoms with uniform backgrounds. Such phantoms may be inadequate when assessing nonlinear reconstruction or postprocessing algorithms. The purpose of this study was to design anatomically informed textured phantoms and use the phantoms to assess quantum noise properties across two clinically available reconstruction algorithms, filtered back projection (FBP) and sinogram affirmed iterative reconstruction (SAFIRE). Methods: Two phantoms were designed to represent lung and soft-tissue textures. The lung phantom included intricate vessel-like structures along with embedded nodules (spherical, lobulated, and spiculated). The soft tissue phantom was designed based on a three-dimensional clustered lumpy background with included low-contrast lesions (spherical and anthropomorphic). The phantoms were built using rapid prototyping (3D printing) technology and, along with a uniform phantom of similar size, were imaged on a Siemens SOMATOM Definition Flash CT scanner and reconstructed with FBP and SAFIRE. Fifty repeated acquisitions were acquired for each background type and noise was assessed by estimating pixel-value statistics, such as standard deviation (i.e., noise magnitude), autocorrelation, and noise power spectrum. Noise stationarity was also assessed by examining the spatial distribution of noise magnitude. The noise properties were compared across background types and between the two reconstruction algorithms. Results: In FBP and SAFIRE images, noise was globally nonstationary for all phantoms. In FBP images of all phantoms, and in SAFIRE images of the uniform phantom, noise appeared to be locally stationary (within a reasonably small region of interest). Noise was locally nonstationary in SAFIRE images of the textured phantoms with edge pixels showing higher noise magnitude compared to pixels in more homogenous regions. For pixels in uniform regions, noise magnitude was reduced by an average of 60% in SAFIRE images compared to FBP. However, for edge pixels, noise magnitude ranged from 20% higher to 40% lower in SAFIRE images compared to FBP. SAFIRE images of the lung phantom exhibited distinct regions with varying noise texture (i.e., noise autocorrelation/power spectra). Conclusions: Quantum noise properties observed in uniform phantoms may not be representative of those in actual patients for nonlinear reconstruction algorithms. Anatomical texture should be considered when evaluating the performance of CT systems that use such nonlinear algorithms.

60 APPLIED LIFE SCIENCES↗

SU-D-BRA-06: Dual-Energy Chest CT: The Effects of Virtual Monochromatic Reconstructions On Texture Analysis Features

Purpose: To characterize the effect of virtual monochromatic reconstructions on several commonly used texture analysis features in DECT of the chest. Further, to assess the effect of monochromatic energy levels on the ability of these textural features to identify tissue types. Methods: 20 consecutive patients underwent chest CTs for evaluation of lung nodules using Siemens Somatom Definition Flash DECT. Virtual monochromatic images were constructed at 10keV intervals from 40–190keV. For each patient, an ROI delineated the lesion under investigation, and cylindrical ROI’s were placed within 5 different healthy tissues (blood, fat, muscle, lung, and liver). Several histogram- and Grey Level Cooccurrence Matrix (GLCM)-based texture features were then evaluated in each ROI at each energy level. As a means of validation, these feature values were then used in a random forest classifier to attempt to identify the tissue types present within each ROI. Their predictive accuracy at each energy level was recorded. Results: All textural features changed considerably with virtual monochromatic energy, particularly below 70keV. Most features exhibited a global minimum or maximum around 80keV, and while feature values changed with energy above this, patient ranking was generally unaffected. As expected, blood demonstrated the lowest inter-patient variability, for all features, while lung lesions (encompassing many different pathologies) exhibited the highest. The accuracy of these features in identifying tissues (76% accuracy) was highest at 80keV, but no clear relationship between energy and classification accuracy was found. Two common misclassifications (blood vs liver and muscle vs fat) accounted for the majority (24 of the 28) errors observed. Conclusion: All textural features were highly dependent on virtual monochromatic energy level, especially below 80keV, and were more stable above this energy. However, in a random forest model, these commonly used features were able to reliably differentiate between most tissues types regardless of energy level. Dr Godoy has received a dual-energy CT research grant from Siemens Healthcare. That grant did not directly fund this research.

60 APPLIED LIFE SCIENCES↗

TU-G-204-05: The Effects of CT Acquisition and Reconstruction Conditions On Computed Texture Feature Values of Lung Lesions

Purpose: Texture features have been investigated as a biomarker of response and malignancy. Because these features reflect local differences in density, they may be influenced by acquisition and reconstruction parameters. The purpose of this study was to investigate the effects of radiation dose level and reconstruction method on features derived from lung lesions. Methods: With IRB approval, 33 lung tumor cases were identified from clinically indicated thoracic CT scans in which the raw projection (sinogram) data were available. Based on a previously-published technique, noise was added to the raw data to simulate reduced-dose versions of each case at 25%, 10% and 3% of the original dose. Original and simulated reduced dose projection data were reconstructed with conventional and two iterative-reconstruction settings, yielding 12 combinations of dose/recon conditions. One lesion from each case was contoured. At the reference condition (full dose, conventional recon), 17 lesions were randomly selected for repeat contouring (repeatability). For each lesion at each dose/recon condition, 151 texture measures were calculated. A paired differences approach was employed to compare feature variation from repeat contours at the reference condition to the variation observed in other dose/recon conditions (reproducibility). The ratio of standard deviation of the reproducibility to repeatability was used as the variation measure for each feature. Results: The mean variation (standard deviation) across dose levels and kernel was significantly different with a ratio of 2.24 (±5.85) across texture features (p=0.01). The mean variation (standard deviation) across dose levels with conventional recon was also significantly different with 2.30 (7.11) (p=0.025). The mean variation across reconstruction settings of original dose has a trend in showing difference with 1.35 (2.60) among all features (p=0.09). Conclusion: Texture features varied considerably with variations in dose and reconstruction condition. Care should be taken to standardize these conditions when using texture as a quantitative feature. This effort supported in part by a grant from the National Cancer Institute’s Quantitative Imaging Network (QIN): U01 CA181156; The UCLA Department of Radiology has a Master Research Agreement with Siemens Healthcare; Dr. McNitt-Gray has previously received research support from Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

TU-G-204-06: Correlation Between Texture Analysis-Based Model Observer and Human Observer in Diagnosis of Ischemic Infarct in Non-Contrast Head CT of Adults

Purpose: To investigate the correlation between texture analysis-based model observer and human observer in the task of diagnosis of ischemic infarct in non-contrast head CT of adults. Methods: Non-contrast head CTs of five patients (2 M, 3 F; 58–83 y) with ischemic infarcts were retro-reconstructed using FBP and Adaptive Statistical Iterative Reconstruction (ASIR) of various levels (10–100%). Six neuro -radiologists reviewed each image and scored image quality for diagnosing acute infarcts by a 9-point Likert scale in a blinded test. These scores were averaged across the observers to produce the average human observer responses. The chief neuro-radiologist placed multiple ROIs over the infarcts. These ROIs were entered into a texture analysis software package. Forty-two features per image, including 11 GLRL, 5 GLCM, 4 GLGM, 9 Laws, and 13 2-D features, were computed and averaged over the images per dataset. The Fisher-coefficient (ratio of between-class variance to in-class variance) was calculated for each feature to identify the most discriminating features from each matrix that separate the different confidence scores most efficiently. The 15 features with the highest Fisher -coefficient were entered into linear multivariate regression for iterative modeling. Results: Multivariate regression analysis resulted in the best prediction model of the confidence scores after three iterations (df=11, F=11.7, p-value<0.0001). The model predicted scores and human observers were highly correlated (R=0.88, R-sq=0.77). The root-mean-square and maximal residual were 0.21 and 0.44, respectively. The residual scatter plot appeared random, symmetric, and unbiased. Conclusion: For diagnosis of ischemic infarct in non-contrast head CT in adults, the predicted image quality scores from texture analysis-based model observer was highly correlated with that of human observers for various noise levels. Texture-based model observer can characterize image quality of low contrast, subtle texture changes in addition to human observers.

60 APPLIED LIFE SCIENCES↗

SU-F-R-13: Decoding 18F-FDG Uptake Heterogeneity for Primary and Lymphoma Tumors by Using Texture Analysis in PET Images

Purpose: To explore 18F-FDG uptake heterogeneity of primary tumor and lymphoma tumor by texture features of PET image and quantify the heterogeneity difference between primary tumor and lymphoma tumor. Methods: 18 patients with primary tumor and lymphoma tumor in lung cancer were enrolled. All patients underwent whole-body 18F-FDG PET/CT scans before treatment. Texture features, based on Gray-level Co-occurrence Matrix, second and high order matrices are extracted from code using MATLAB software to quantify 18F-FDG uptake heterogeneity. The relationships of volume between energy, entropy, correlation, homogeneity and contrast were analyzed. Results: For different cases, tumor heterogeneity was not the same. Texture parameters (contrast, entropy, and correlation) of lymphoma were lower than primary tumor. On the contrast, the texture parameters (energy, homogeneity and inverse different moment) of lymphoma were higher than primary tumor. Significantly, correlations were observed between volume and energy (primary, r=−0.194, p=0.441; lymphoma, r=−0.339, p=0.582), homogeneity (primary, r=−0.146, p=0.382; lymphoma, r=−0.193, p=0.44), inverse difference moment (primary, r=−0.14, p=0.374; lymphoma, r=−0.172, p=0.414) and a positive correlation between volume and entropy (primary, r=0.233, p=0.483; lymphoma, r=0.462, p=0.680), contrast (primary, r=0.159, p=0.399; lymphoma, r=0.341, p=0.584), correlation (primary, r=0.027, p=0.165; lymphoma, r=0.046, p=0.215). For the same patient, energy for primary and lymphoma tumor is equal. The volume of lymphoma is smaller than primary tumor, but the homogeneity were higher than primary tumor. Conclusion: This study showed that there were effective heterogeneity differences between primary and lymphoma tumor by FDG-PET image texture analysis.

60 APPLIED LIFE SCIENCES↗

SU-F-R-20: Image Texture Features Correlate with Time to Local Failure in Lung SBRT Patients

Purpose: To explore possible correlation between CT image-based texture and histogram features and time-to-local-failure in early stage non-small cell lung cancer (NSCLC) patients treated with stereotactic body radiotherapy (SBRT).Methods and Materials: From an IRB-approved lung SBRT registry for patients treated between 2009–2013 we selected 48 (20 male, 28 female) patients with local failure. Median patient age was 72.3±10.3 years. Mean time to local failure was 15 ± 7.1 months. Physician-contoured gross tumor volumes (GTV) on the planning CT images were processed and 3D gray-level co-occurrence matrix (GLCM) based texture and histogram features were calculated in Matlab. Data were exported to R and a multiple linear regression model was used to examine the relationship between texture features and time-to-local-failure. Results: Multiple linear regression revealed that entropy (p=0.0233, multiple R2=0.60) from GLCM-based texture analysis and the standard deviation (p=0.0194, multiple R2=0.60) from the histogram-based features were statistically significantly correlated with the time-to-local-failure. Conclusion: Image-based texture analysis can be used to predict certain aspects of treatment outcomes of NSCLC patients treated with SBRT. We found entropy and standard deviation calculated for the GTV on the CT images displayed a statistically significant correlation with and time-to-local-failure in lung SBRT patients.

60 APPLIED LIFE SCIENCES↗

SU-F-R-28: Correction of FCh-PET Bladder Uptake Using Virtual Sinograms and Investigation of Its Impact On the Quantification of Prostate Textural Characteristics

Purpose: Textural biomarkers as a tool for quantifying intratumoral heterogeneity hold great promise for diagnosis and early assessment of treatment response in prostate cancer. However, spill-in counts from the bladder uptake are suspected to have an impact on the textural measurements of the prostate volume. This work proposes a correction method for the FCh-PET bladder uptake and investigates its impact on intraprostatic textural properties. Methods: Two patients with PC received pre-treatment dynamic FCh-PET scans reconstructed at four time points (interval: 2 min), for which prostate and bladder contours were obtained. Projection bins affected by bladder uptake were determined by forward-projection. For each time point and axial position, virtual sinograms were obtained and affected bins replaced by a weighted combination of original values and values interpolated using cubic spline from non-affected bins of the current and adjacent projection angles. The process was optimized using a genetic algorithm in terms of minimization of the root-mean-square error (RMSE) within the bladder between the corrected dynamic time point volume and a reference initial uptake volume. Finally, the impact of the bladder uptake correction on the prostate region was investigated using two standard SUV metrics (1) and three texture metrics (2): 1) SUVmax, SUVmean; 2) Contrast, Homogeneity, Coarseness. Results: Without bladder uptake correction, SUVmax and SUVmean were on average overestimated in the prostate by 0%, 0%, 33.2%, 51.2%, and 3.6%, 6.0%, 2.9%, 3.2%, for each time point respectively. Contrast varied by −9.1%, −6.7%, +40.4%, +107.7%, and Homogeneity and Coarseness by +4.5%, +1.8%, −8.8%, −14.8% and +1.0%, +0.5%, −9.5%, +0.9%. Conclusion: We proposed a method for FCh-PET bladder uptake correction and showed an impact on the quantification of the prostate signal. This method achieved a large reduction of intra-prostatic SUVmax while minimizing the impact on SUVmean. Further investigation is necessary to interpret changes in textural features. SL acknowledges partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council (Grant number: 432290).

60 APPLIED LIFE SCIENCES↗

SU-F-R-38: Impact of Smoothing and Noise On Robustness of CBCT Textural Features for Prediction of Response to Radiotherapy Treatment of Head and Neck Cancers

Purpose: To examine the impact of image smoothing and noise on the robustness of textural information extracted from CBCT images for prediction of radiotherapy response for patients with head/neck (H/N) cancers. Methods: CBCT image datasets for 14 patients with H/N cancer treated with radiation (70 Gy in 35 fractions) were investigated. A deformable registration algorithm was used to fuse planning CT’s to CBCT’s. Tumor volume was automatically segmented on each CBCT image dataset. Local control at 1-year was used to classify 8 patients as responders (R), and 6 as non-responders (NR). A smoothing filter [2D Adaptive Weiner (2DAW) with 3 different windows (ψ=3, 5, and 7)], and two noise models (Poisson and Gaussian, SNR=25) were implemented, and independently applied to CBCT images. Twenty-two textural features, describing the spatial arrangement of voxel intensities calculated from gray-level co-occurrence matrices, were extracted for all tumor volumes. Results: Relative to CBCT images without smoothing, none of 22 textural features extracted showed any significant differences when smoothing was applied (using the 2DAW with filtering parameters of ψ=3 and 5), in the responder and non-responder groups. When smoothing, 2DAW with ψ=7 was applied, one textural feature, Information Measure of Correlation, was significantly different relative to no smoothing. Only 4 features (Energy, Entropy, Homogeneity, and Maximum-Probability) were found to be statistically different between the R and NR groups (Table 1). These features remained statistically significant discriminators for R and NR groups in presence of noise and smoothing. Conclusion: This preliminary work suggests that textural classifiers for response prediction, extracted from H&N CBCT images, are robust to low-power noise and low-pass filtering. While other types of filters will alter the spatial frequencies differently, these results are promising. The current study is subject to Type II errors. A much larger cohort of patients is needed to confirm these results. This work was supported in part by a grant from Varian Medical Systems (Palo Alto, CA)

60 APPLIED LIFE SCIENCES↗

Texture development during rolling of α+β dual-phase ZrNb alloys - 2016-0070

The texture evolution during high-temperature rolling (800 deg. C) of two model zirconium-niobium alloys was studied using electron backscatter diffraction. The aim was to decouple the relative importance of deformation and phase transformation on the final texture in an effort to elucidate the origin of the strong α-transverse basal texture commonly found in the hot-rolled product. The analysis uses a reconstruction software based on the Burgers relation to reconstruct the high-temperature β orientations, with the indexed α as input. In the low niobium content alloy, the texture evolution of the {11 2-bar 0}<10 1-bar 0> component was consistent with deformation in both α and β phases, along with a variant selection mechanism that occurred during the β → α phase transformation. Variant selection was observed to depend on the orientation of the deformed prior β grains. In the high niobium content alloy, a lower α volume fraction during hot rolling gave rise to different β textures and promoted the formation of a Goss component. This contributed to the {11 2-bar 0} <10 1-bar 0> component upon cooling, with variant selection enhanced by anisotropic grain breakup. (authors)

36 MATERIALS SCIENCE↗

Equal channel angular extrusion for bulk processing of Fe–Co–2V soft magnetic alloys, part II: Texture analysis and magnetic properties

In Part I, equal channel angular extrusion (ECAE) was demonstrated as a novel, simple-shear deformation process for producing bulk forms of the low ductility Fe–Co–2V (Hiperco 50A®) soft ferromagnetic alloy with refined grain sizes. Microstructures and mechanical properties were discussed. In this Part II contribution, the crystallographic textures and quasi-static magnetic properties of ECAE-processed Hiperco were characterized. The textures were of a simple-shear character defined by partial {110} and <111> fibers inclined relative to the extrusion direction, in agreement with the expectations for simple-shear deformation textures of BCC metals. These textures were observed throughout all processing conditions and only slightly reduced in intensity by subsequent recrystallization heat treatments. Characterization of the magnetic properties revealed a lower coercivity and higher permeability for ECAE-processed Hiperco specimens relative to the conventionally processed and annealed Hiperco bar. In conclusion, the effects of the resultant microstructure and texture on the coercivity and permeability magnetic properties are discussed.

36 MATERIALS SCIENCE↗