Temperature Fluctuations and Boundary Layer Turbulence as seen by Mars Exploration Rovers Miniature Thermal Emission Spectrometer

The Mini-TES spectrometer carried by Spirit and Opportunity is a unique instrument that enabled vertical temperature profiles to be retrieved at high frequency (every 2 s, or “ICK”). Observations obtained from this instrument provide information on boundary layer activity. As an extension of previous work, we have retrieved ICK-by-ICK vertical temperature profiles to characterize turbulent behavior at each rover site for up to two Mars Years. We have also retrieved ICK-by-ICK near-surface (1.1 m) atmospheric temperatures and surface temperatures from dedicated atmospheric observations as well as geologic observations that extend the coverage of near-surface observations. The extension and increased frequency of retrievals as well as the additional observations provide a more complete view of the vertical and temporal variation of temperature fluctuations within the PBL. Temperature fluctuations are assessed using detrended temperature time-series data. The results show fluctuations can be as large as 10 K at the surface and 8 K aloft with timescales on the order of minutes. We have calculated the peak-to-peak amplitudes of temperature fluctuations and the corresponding timescales over which they occur. Spirit and Opportunity temperature fluctuation amplitudes decrease in magnitude vertically, where higher atmospheric levels show smaller fluctuations in amplitudes than at the surface. The magnitude of temperature fluctuations changes with the difference in surface and air temperature. This difference varies little as a function of season at both rover sites. Fluctuations are observed to quickly decrease in the late afternoon reaching a minimum near 17:00 LTST followed by moderately increased activity near sunset caused by forced convection. There is no significant change in the observed convective activity as a function of dust optical depth during regional dust storms. The few large temperature fluctuations that are concurrent with dust events are likely the result of large-scale systems.

Mars, atmosphere↗

SNPP and N20 VIIRS Thermal Emissive Bands Calibration Comparison Using the GEO-LEO Double Difference Method

The VIIRS instruments onboard the SNPP and NOAA-20 satellites have identical spatial resolutions and the same spectral bands. Similar prelaunch tests and identical on-orbit calibration algorithms established the foundation for their consistent Earth measurements. Calibration assessment and consistency comparisons are useful to maintain their performance and measurement accuracy. Simultaneous nadir overpasses (SNO) between two satellites are commonly used for a direct calibration comparison between sensors. However, there are no SNO between SNPP and NOAA20. Hence, a reference sensor or Earth measurements are normally used to bridge the comparison. As a reference, we focus on the Advanced Baseline Imager (ABI) onboard the GOES-R series spacecraft and its application to the SNPP and NOAA-20 VIIRS comparison. GOES16 and GOES17are the first two satellites of the GOES-R series and were launched on November 19, 2016, and March 12, 2018, respectively. Their operational positions are on the equator with longitudes of 75.2° West over land and 137.2° West over ocean, respectively. The ABI is the primary imaging instrument of these spacecrafts for the Earth’s weather, oceans, and environment, with observations (every 10 minutes) that provide vast data for GEO-Low Earth orbit (LEO)and LEO-LEO comparisons utilizing it as an intermediate reference sensor. VIIRS and ABI have spectrally matched bands and can have simultaneous measurements over any selected site every day. The simultaneous measurements over the same site also have various scan angles. These features provide advantages for a VIIRS-to-ABI comparison. The spectral response function difference between instruments, sites selected, and view angles will have effects on the instrument measurements. Their impacts on the calibration comparison, including the use of double differences, will be discussed. By collecting VIIRS measurements over a large range of view angles, the view angle effect will also be investigated. The collection of an ample amount of data provides an advantage for statistical analyses and potential big data applications to sensor calibration assessments. This method can also be applied to other sensor calibration comparison and performance assessments, such as GOES16 and GOES17 ABI, and Terra and Aqua MODIS.

Tiejun Chang↗