Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermistor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

244 records · Page 14

PAssive Thermal Coating Observatory Operating in Low Earth Orbit (PATCOOL)

The PATCOOL is a NASA sponsored, University of Florida developed 3U CubeSat meant to investigate the feasibility of using a cryogenic selective surface coating as a new, more efficient way of passively cooling components in space. Initial tests on the ground demonstrate that this coating should provide a much higher reflectance of the Sun's irradiant power than any existing coating, while still providing far-infrared power emission. The ultimate validation of this technology requires on-orbit testing. PATCOOL hosts a 4-sample housing, with the samples shaped as thin cylinders (coin-like). Two samples are coated with state-of-the-art material, while the other pair uses the new coating to be evaluated. The temperatures of all samples during the mission (minimum 72 hours of data collection) are measured via thermistors. The samples are connected via thin Kevlar strings to the housing, to minimize heat transfer. The housing is designed to shield the samples from Earth's thermal radiation, and the CubeSat is attitude stabilized and controlled via a gravity gradient boom, magnetorquers and a reaction wheel set. Thermal Desktop simulations show PATCOOL's ability to thermally isolate the samples from heat exchanges other than with Sun and deep space, thanks to its thermal design and the chosen attitude profile

Ojeda, Carlos↗

Updates to the Absolute Radiometric Accuracy of the AIRS on Aqua

The Atmospheric Infrared Sounder (AIRS) on the EOS Aqua Spacecraft was launched on May 4, 2002. The AIRS was designed to measure small changes in the global hydro-thermodynamic cycle and has demonstrated exceptional radiometric and spectral stability and accuracy in-orbit. This accuracy is achieved by transferring the calibration from a Large Area Blackbody (LABB) to the On-Board Calibrator (OBC) blackbody during preflight testing. The LABB theoretical emissivity is in excess of 0.9999 and temperature uncertainty is less than 50 mK. The LABB emitted radiance is NIST traceable through thermistors located on the internal surfaces. The AIRS also provides a full aperture space view every scan for offset calibration. AIRS nonlinearity and polarization calibration coefficients were based on pre-flight testing and have been amongst the highest uncertainty sources in the calibration. A recent method using on-board space view data has reduced the uncertainty of the polarization coefficients and use of separate A side and B side data from preflight testing has reduced the uncertainty of the nonlinearity estimates. An update to the system radiometric uncertainty is made based on the new data and is presented in this paper.

Weiler, Margaret H.↗

Estimation of Thermodynamic and Dynamic Contributions to Sea Ice Growth in the Central Arctic Using ICESat-2 and MOSAiC SIMBA Buoy Data

The fine spatial resolution of the ICESat-2 (IS2) satellite altimeter allows monitoring the evolution of sea ice thickness with detailed dynamic information (e.g. ridges and leads). In this study, we first assess the ability of IS2 to estimate thermodynamic ice growth and dynamic thickening during the ice-growing season in the central Arctic Ocean. As an indicator of the thermodynamic ice growth, we use 10 thermistor string-based sea ice mass balance array (SIMBA) buoys deployed at a scale of ~ 50 km from the Icebreaker Polarstern during the Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) expedition. We collect IS2 data within 20 km buffer distance from the individual buoys, and calculate the mode, median, and mean of the IS2-derived ice thickness. The IS2 modal thickness shows the least bias (−0.169 m) with the buoy ice thickness, representing level ice thickness. In addition, the increasing rate of the IS2 modal thickness is close to the thermodynamic ice growth with a small bias of −0.054 cm/day. However, the increasing rates of the IS2 median and mean thickness are greater than the thermodynamic ice growth by about 0.114 cm/day and 0.198 cm/day, respectively, because they also include ice growth caused by thickness redistribution during dynamic deformation. The dynamic contributions may account for 26.1 ± 10.3% and 34.4 ± 10.1% of the total increase of the IS2 median and mean thickness, respectively. Within a ~ 50 km radius area from the MOSAiC Central Observatory, IS2 measurements exhibit that the ridge fraction increased from <2% in November to ~ 4% in March (~0.029%/day of average increasing rate) and ridge height increased about 0.047 cm/day during the same period. However, lead formation does not show significant contributions to the dynamic ice thickening because leads are temporary features lasting only 2–3 days. Although there are considerable uncertainties in IS2 ice thickness estimation and IS2-buoy thickness comparison, this study emphasizes the importance of combining measurements by IS2 and SIMBA buoys to explain the regional sea ice mass balance with separating the thermodynamic and dynamic contributions.

satellite altimeter↗

Electrical Ground Support Equipment for the Sampling Caching System of the Mars 2020 Rover

In this work we describe in detail the architecture, design, testing and operation of the Electrical Ground Support Equipment (EGSE) “Blue Box” used to test and validate the Sampling Caching System (SCS) of the Mars 2020 Perseverance rover. The Blue Box architecture is centered around COTS motor controllers and COTS input-output modules communicating over an EtherCAT bus. A custom, low-level safety subsystem ensures no harm can be done to the flight articles. The modular architecture of the EGSE reduces cost and complexity while expediting assembly time. The Blue Box drives the 19 actuators of the SCS which span the main robotic arm, the corer system, the internal sample handling arm, the sample tube sealing system and the gas dust removal tool; mimicking the Rover Motor Control Assembly (RMCA). Due to the limited availability of RMCA’s, the EGSE enabled and performed the bulk of testing activities for SCS. The majority of the SCS actuators are composed of a 3-phase DC brushless motors, hall sensors for commutation, dual resolvers for output angular measurement, brakes, heaters and platinum thermistors. Additionally, the EGSE read 12 strain gauges forming part of a force torque sensor, and switches used for external positioning references. Over the 3-year span of the V&V campaign for the SCS, over 32 EGSE systems were built, tested and deployed to test venues at JPL and externally. The EGSE tested several families of the SCS subsystem, ranging from engineering units, life test units and two flight units. Test venues that this EGSE supported included lab benches, ultra-clean cleanrooms, ATLO facilities, and thermal vacuum chambers. Together with the test software systems, SSDEV and SSDEV-ECAT, the Blue Box EGSE enabled the team to efficiently test flight hardware and flight software together. We go over the safety features and fault management techniques employed to protect flight hardware. The effects of the long, 50-feet, EGSE harnesses on motor performance, EMI, electrical noise, and motor control performance are explained. Mitigations to these unwanted effects, including shielding strategy and inductance compensation, are summarized. We go over an excerpt of notable anomalies that this EGSE suffered through its operation, along with investigations and resolutions. Lessons learned, areas of improvement as part of future work, and recommendations for future implementations for similar EGSE’s, are shared.

Levine, Dan↗

Operational Correction for the Temperature Dependence of A Class of Hyperspectral Radiometers

The correction for temperature response of optical radiometers implies access to their working temperature (i.e., either the internal or ambient one with the radiometers in thermal equilibrium). With specific reference to a class of widely used hyperspectral radiometers lacking a thermistor to measure the internal temperature, this work investigated the potential for operational corrections relying on the ambient temperature derived from the radiometer dark digital counts. With the objective to keep within approximately 1% the uncertainty for radiometric corrections in the 400–800-nm spectral range, findings showed the applicability of the method for ambient temperatures higher than approximately 30°C. The alternative use of an ambient temperature proxy, determined from the air temperature incremented by a few degrees Celsius, was shown a valid solution to constrain the uncertainty of radiometric corrections to within 1% over the entire 0°–40°C interval.

Giuseppe Zibordi↗

xEMU Spacesuit Boot Lunar South Pole Thermal Vacuum Testing

The Exploration Extravehicular Mobility Unit (xEMU) spacesuit lunar boot was evaluated in the Jet Propulsion Lab (JPL) CITADEL thermal vacuum chamber at lunar South Pole conditions. The JPL CITADEL chamber provides a radiation environment and contact plate temperature of 48K, simulating the temperature of a lunar Permanently Shadowed Region (PSR) at the South Pole of the Moon. The main objectives of the test series are: to evaluate the risk lunar PSRs pose to advanced spacesuit boots, validate the xEMU lunar boot thermal model, and to develop a test methodology to evaluate lunar spacesuit boots. To simulate the thermal effects of a crewmember’s foot inside the boot, a thermal manikin foot was developed to inject heat into the spacesuit boot. Thermal data was collected through a variety of sensors including thermocouples, thermistors, heat flux sensors, and infrared cameras. A test matrix was developed to investigate the variables of foot contact force, simulated skin temperature, external contact plate temperature, and ventilation flowrate. The JPL CITADEL chamber includes a loadlock (airlock) that afforded the ability to simulate the transition of the boot from a thermally neutral IVA condition to a cold EVA condition within seconds. This paper will document the test design, test objectives, success criteria, test support equipment, spacesuit boot to chamber interfaces, and configuration of the test article. Additionally, this paper will document the high-level results of the testing. More detailed test results will be presented in a different paper.

Ben Swartout↗

xEMU Spacesuit Boot Lunar South Pole Thermal Vacuum Testing

The Exploration Extravehicular Mobility Unit (xEMU) spacesuit lunar boot was evaluated in the Jet Propulsion Lab (JPL) CITADEL thermal vacuum chamber at lunar South Pole conditions. The JPL CITADEL chamber provides a radiation environment and contact plate temperature of 48K, simulating the temperature of a lunar Permanently Shadowed Region (PSR) at the South Pole of the Moon. The main objectives of the test series were: to evaluate the risk lunar PSRs pose to advanced spacesuit boots, validate the xEMU lunar boot thermal model, and develop a test methodology to evaluate lunar spacesuit boots. To simulate the thermal effects of a crewmember’s foot inside the boot, a thermal manikin foot was developed to inject heat into the spacesuit boot. Thermal data was collected through a variety of sensors including thermocouples, thermistors, heat flux sensors, and infrared cameras. A test matrix was developed to investigate the variables of foot contact force, simulated skin temperature, external contact plate temperature, and ventilation flowrate. The JPL CITADEL chamber includes a loadlock (airlock) that afforded the ability to simulate the transition of the boot from a thermally neutral IVA condition to a cold EVA condition within seconds. This paper will document the test design, test objectives, success criteria, test support equipment, spacesuit boot to chamber interfaces, and configuration of the test article. Additionally, this paper will document the high-level results of the testing. More detailed test results will be presented in a different paper.

TVAC↗

High Temperature Thick Film Sensor Development Based on Refractory Oxide Semiconductors

Solid-state, high-temperature sensing devices are required for accurate temperature, strain/stress, and failure monitoring for a range of advanced manufacturing, transportation, and military applications. High temperature conditions limit sensing strategies, where typically traditional metal and semiconductor materials are unstable, and the sensing options are limited to optical spectroscopy methods. In addition, strategies to embed the sensors directly within active components and protective thermal refractory are of interest that permit near-environment sensing which is not possible with the traditional electronic materials and components. Rare-earth chromite semiconductors exhibit some properties of interest for high temperature sensing technologies, such as: high microstructure and chemical stability, relatively high electronic conductivity at high temperatures, and relative thermal expansion coefficient matching to refractory thermal protective insulation (such as high-zirconia and -alumina ceramics). In this work, n-type and p-type doped lanthanum chromites compositions were computationally modelled and prepared, and the electrical, thermoelectric, and thermomechanical properties were measured for the obtained material systems. A few compositions were then processed into thick film health and temperature sensors and tested at high temperatures. To establish relative stability under harsh environment conditions, post- mortem microstructure and chemical composition was characterized after extended and cycle testing at high temperatures.

20 FOSSIL-FUELED POWER PLANTS↗

Low Temperature Microcalorimeters for Decay Energy Spectroscopy

Low Temperature Detectors have been used to measure embedded radioisotopes in a measurement mode known as Decay Energy Spectroscopy (DES) since 1992. DES microcalorimeter measurements have been used for applications ranging from neutrino mass measurements to metrology to measurements for safeguards and medical nuclides. While the low temperature detectors have extremely high intrinsic energy resolution (several times better than semiconductor detectors), the energy resolution achieved in practice is strongly dependent on factors such as sample preparation method. This review seeks to present the literature consensus on what has been learned by looking at the energy resolution as a function of various choices of detector, absorber, and sample preparation methods.

47 OTHER INSTRUMENTATION↗