Search NASA⌕ Search

SEARCH · Search NASA

Results for “tracking ranging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Ultrasonic ranging for the oculometer

Ultrasonic tracking techniques are investigated for an oculometer. Two methods are reported in detail. The first is based on measurements of time from the start of a transmit burst to a received echo. Knowing the sound velocity, distance can be calculated. In the second method, a continuous signal is transmitted. Target movement causes phase shifting of the echo. By accumulating these phase shifts, tracking from a set point can be achieved. Both systems have problems with contoured targets, but work well on flat plates and the back of a human head. Also briefly reported is an evaluation of an ultrasonic ranging system. Interface circuits make this system compatible with the echo time design. While the system is consistently accurate, it has a beam too narrow for oculometer use. Finally, comments are provided on a tracking system using the Doppler frequency shift to give range data.

Guy, W. J.↗

Large-scale waves in the ionosphere observed by the AE satellite

Atmospheric Explorer (AE) satellite data were used to establish whether coherent waves in the gravity wave range are present in both neutral and ionized media in the thermosphere. The AE-C data in particular are shown. Data consist of the in situ argon, helium, nitrogen, and oxygen densities, plasma density, and ion and electron temperatures. Filtering provides the fluctuation signals for each which are spectrum analyzed for power and cross spectra. The observed frequencies are essentially proportional to the spatial wavenumbers along the satellite track. Scale sizes range from thousands to tens of kilometers.

Gross, S. H.↗

Laser Doppler velocimeter system simulation for sensing aircraft wake vortices. Part 2: Processing and analysis of LDV data (for runs 1023 and 2023)

A data analysis program constructed to assess LDV system performance, to validate the simulation model, and to test various vortex location algorithms is presented. Real or simulated Doppler spectra versus range and elevation is used and the spatial distributions of various spectral moments or other spectral characteristics are calculated and displayed. Each of the real or simulated scans can be processed by one of three different procedures: simple frequency or wavenumber filtering, matched filtering, and deconvolution filtering. The final output is displayed as contour plots in an x-y coordinate system, as well as in the form of vortex tracks deduced from the maxima of the processed data. A detailed analysis of run number 1023 and run number 2023 is presented to demonstrate the data analysis procedure. Vortex tracks and system range resolutions are compared with theoretical predictions.

Meng, J. C. S.↗

Lunar Node 1 and Beyond

Lunar Node 1 (LN-1) is an S-band Navigation beacon for lunar applications that was recently designed and built at MSFC. As part of NASA's Commercial Lunar Payload Services initiative, this beacon will be delivered to the moon's surface on Intuitive Machine's NOVA-C lunar lander in November 2021. During this mission, LN-1’s goal will be to demonstrate navigation technologies that can support local surface and orbital operations around the moon, enabling autonomy which would decrease dependency on heavily utilized Earth based assets like the Deep Space Network. To do this, LN-1’s design leverages Cubesat components as well as the Multi-spacecraft Autonomous Positioning System (MAPS) algorithms, which enable the autonomous spacecraft positioning through communication-integrated navigation measurements. In addition to demonstrating the MAPS payload, the radio will also be used in standard tone-based non-coherent ranging and Doppler tracking to provide an alternate approaches and comparisons for navigation performance. LN-1 will represent a single node in a potential greater MAPS network of assets. While LN-1 awaits launch to demonstrate this initial use of one-way navigation, designs are already under way for proposed subsequent missions like LN-2 to enable expanded capability. The next steps in these missions seek to include a receive capability to allow two-way ranging support with other operational spacecraft in the lunar vicinity, and to provide some component upgrades related to the radio, power, and thermal systems that will improve the longevity of the payload in the harsh lunar environment. The LN-1 design details, status, and potential forward work with mission like LN-2 will be outlined in this presentation.

Evan John Anzalone↗

Precise Orbit Determination for GEOSAT Follow-On Using Satellite Laser Ranging Data and Intermission Altimeter Crossovers

The U.S. Navy's GEOSAT Follow-On Spacecraft was launched on February 10, 1998 and the primary objective of the mission was to map the oceans using a radar altimeter. Following an extensive set of calibration campaigns in 1999 and 2000, the US Navy formally accepted delivery of the satellite on November 29, 2000. The spacecraft is tracked by satellite laser ranging (SLR) and Doppler (Tranet-style) beacons. Although a limited amount of GPS data were obtained, the primary mode of tracking remains satellite laser ranging. In this paper, we report on progress in orbit determination for GFO using GFO/GFO and TOPEX/GFO altimeter crossovers. We have tuned the nonconservative force model for GFO and the gravity model using SLR, Doppler and altimeter crossover data spanning over one year. Preliminary results show that the predicted radial orbit error from the gravity field covariance to 70x70 on GEOSAT was reduced from 2.6 cm in EGM96 to 1.9 cm with the addition of only five months of the GFO SLR and GFO/GFO crossover data. Further progress is possible with the addition of more data, particularly the TOPEX/GFO crossovers. We will evaluate the tuned GFO gravity model (a derivative of EGM96) using altimeter data from the GEOSAT mission. In January 2000, a limited quantity of GPS data were obtained. We will use these GPS data in conjunction with the SLR and altimeter crossover data obtained over the same time span to compute quasi-reduced dynamic orbits which will also aid in the evaluation of the tuned GFO geopotential model.

Lemoine, F. G.↗

A vacuum (10(exp -9) Torr) friction apparatus for determining friction and endurance life of MoSx films

The first part of this paper describes an ultrahigh vacuum friction apparatus (tribometer). The tribometer can be used in a ball-on-disk configuration and is specifically designed to measure the friction and endurance life of solid lubricating films such as MoS(x) in vacuum at a pressure of 10 exp -7 Pa. The sliding mode is typically unidirectional at a constant rotating speed. The second part of this paper presents some representative friction and endurance life data for magnetron sputtered MoS(x) films (110 nm thick) deposited on sputter-cleaned 440 C stainless-steel disk substrates, which were slid against a 6-mm-diameter 440 C stainless-steel bearing ball. All experiments were conducted with loads of 0.49 to 3.6 N (average Hertzian contact pressure, 0.33 to 0.69 GPa), at a constant rotating speed of 120 rpm (sliding velocity ranging from 31 to 107 mm/s due to the range of wear track radii involved in the experiments), in a vacuum of 7 x 10 exp -7 Pa and at room temperature. The results indicate that there are similarities in friction behavior of MoS(x) films overs their life cycles regardless of load applied. The coefficient of friction (mu) decreases as load W increases according to mu = kW exp -1/3. The endurance life E of MoS(x) films decreases as the load W increases according to E = KW exp -1.4 for the load range. The load- (or contract-pressure-) dependent endurance life allows us to reduce the time for wear experiments and to accelerate endurance life testing of MoS(x) films. For the magnetron-sputtered MoS(x) films deposited on 440 C stainless-steel disks: the specific wear rate normalized to the load and the number of revolutions was 3 x 10 exp -8 mm exp 3/N-revolution; the specific wear rate normalized to the load and the total sliding distance was 8 x 10 exp -7 mm exp 3/N-m; and the nondimensional wear coefficient of was approximately 5 x 10 exp -6. The values are almost independent of load in the range 0.49 to 3.6 N (average Hertzian contact pressures of 0.33 to 0.69 GPa).

Miyoshi, Kazuhisa↗

Radar Interferometer for Topographic Mapping of Glaciers and Ice Sheets

A report discusses Ka-band (35-GHz) radar for mapping the surface topography of glaciers and ice sheets at high spatial resolution and high vertical accuracy, independent of cloud cover, with a swath-width of 70 km. The system is a single- pass, single-platform interferometric synthetic aperture radar (InSAR) with an 8-mm wavelength, which minimizes snow penetration while remaining relatively impervious to atmospheric attenuation. As exhibited by the lower frequency SRTM (Shuttle Radar Topography Mission) AirSAR and GeoSAR systems, an InSAR measures topography using two antennas separated by a baseline in the cross-track direction, to view the same region on the ground. The interferometric combination of data received allows the system to resolve the pathlength difference from the illuminated area to the antennas to a fraction of a wavelength. From the interferometric phase, the height of the target area can be estimated. This means an InSAR system is capable of providing not only the position of each image point in along-track and slant range as with a traditional SAR but also the height of that point through interferometry. Although the evolution of InSAR to a millimeter-wave center frequency maximizes the interferometric accuracy from a given baseline length, the high frequency also creates a fundamental problem of swath coverage versus signal-to-noise ratio. While the length of SAR antennas is typically fixed by mass and stowage or deployment constraints, the width is constrained by the desired illuminated swath width. As the across-track beam width which sets the swath size is proportional to the wavelength, a fixed swath size equates to a smaller antenna as the frequency is increased. This loss of antenna size reduces the two-way antenna gain to the second power, drastically reducing the signal-to-noise ratio of the SAR system. This fundamental constraint of high-frequency SAR systems is addressed by applying digital beam-forming (DBF) techniques to synthesize multiple simultaneous receive beams in elevation while maintaining a broad transmit illumination. Through this technique, a high antenna gain on receive is preserved, thereby reducing the required transmit power and thus enabling high-frequency SARs and high-precision InSAR from a single spacecraft.

Moller, Delwyn K.↗

Implementation of a Model Predictive Control Strategy to Regulate Temperature Inside Plug-Flow Solar Reactor With Countercurrent Flow

Abstract Solar-driven thermochemical energy storage systems are proven to be promising energy carriers (solar fuels) to utilize solar energy by using reactive solid-state pellets. However, the production of solar fuel requires a quasi-steady-state process temperature, which represents the main challenge due to the transient nature of solar power. In this work, an adaptive model predictive controller (MPC) is presented to regulate the temperature inside a tubular solar reactor to produce solid-state solar fuel for long-term thermal storage systems. The solar reactor system consists of a vertical tube heated circumferentially over a segment of its length by concentrated solar power, and the reactive pellets (MgMn2O4) are fed from the top end and flow downwards through the heated tube. A countercurrent flowing gas supplied from the lower end interacts with flowing pellets to reduce it thermochemically at a temperature range of 1000—1500 °C. A low-order physical model was developed to simulate the dynamics of the solar reactor including the reaction kinetics, and the proposed model was validated numerically by using a 7-kW electric furnace. The numerical model then was utilized to design the MPC controller, where the control system consists of an MPC code linked to an adaptive system identification code that updates system parameters online to ensure system robustness against external disturbances (sudden change in the flow inside the reactor), model mismatches, and uncertainty. The MPC controller parameters are tuned to enhance the system performance with minimum steady-state error and overshoot. The controller is tested to track different temperature ranges between 500 °C and 1400 °C with different particles/gas mass flowrates and ramping temperature profiles. Results show that the MPC controller successfully regulated the reactor temperature within ± 1 °C of its setpoint and maintained robust performance with minimum input effort when subjected to sudden changes in the amount of flowing media and the presence of chemical reaction.

Engineering↗

Advances in image compression and automatic target recognition; Proceedings of the Meeting, Orlando, FL, Mar. 30, 31, 1989

Various papers on image compression and automatic target recognition are presented. Individual topics addressed include: target cluster detection in cluttered SAR imagery, model-based target recognition using laser radar imagery, Smart Sensor front-end processor for feature extraction of images, object attitude estimation and tracking from a single video sensor, symmetry detection in human vision, analysis of high resolution aerial images for object detection, obscured object recognition for an ATR application, neural networks for adaptive shape tracking, statistical mechanics and pattern recognition, detection of cylinders in aerial range images, moving object tracking using local windows, new transform method for image data compression, quad-tree product vector quantization of images, predictive trellis encoding of imagery, reduced generalized chain code for contour description, compact architecture for a real-time vision system, use of human visibility functions in segmentation coding, color texture analysis and synthesis using Gibbs random fields.

Tescher, Andrew G.↗

Impairment of Human Ocular Tracking with Low-Dose Alcohol

Previous studies have documented adverse effects of alcohol on oculomotor performance. For example, moderate-dose alcohol (yielding a Blood Alcohol Concentration or BAC of 0.04-0.1%) has been shown to decrease steady-state pursuit gain (Fransson et al., 2010, Clin Neurophysiol, 121(12): 2134; Moser et al., 1998, J Neurol, 245(8): 542; Roche & King, 2010, Psychopharmacology, 212(1): 33), to increase saccade latency (Moser et al., 1998, J Neurol, 245(8): 542; Roche & King, 2010, Psychopharmacology, 212(1): 33), to decrease peak saccadic velocity (Fransson et al., 2010, Clin Neurophysiol, 121(12): 2134; Roche & King, 2010, Psychopharmacology, 212(1): 33), and to increase the frequency of catch-up saccades (Moser et al., 1998, J Neurol, 245(8): 542). Here, we administered two doses of ethanol on different days, yielding moderate (0.06%) and low (0.02%) levels of initial BAC, to examine the effects on human ocular tracking over BACs ranging from 0.00 to 0.07%. Twelve subjects (8 females) participated in a 5-day study. Three days of at-home measurements of daily activity and sleep were monitored, followed by two laboratory days where, ~5 hours after awakening, we administered one of the two possible single doses of alcohol. Using a previously published paradigm (Liston & Stone, 2014, J Vis, 14(14): 12), we measured oculomotor performance multiple times throughout the day with three pre-dosing baseline runs and bi-hourly post-dosing test runs until the subject recorded a BAC of 0.00% for two hours. BAC was measured before each run using an Alco-Sensor IV breathalyzer (Intoximeters, Inc., St. Louis, MO). For each of the oculometric measures, for each subject, we computed the within-subject % deviation for each test run from their baseline averaged across their three pre-dosing runs. We then averaged the data across subjects in 0.01% BAC bins. Finally, we used linear regression to compute the slope and x-intercept (threshold) of the mean binned % deviation as a function of BAC. We found that pursuit initiation was impaired at very low BAC levels, with significant (p < 0.002) linear trends in latency (+1.3%/0.01%BAC) and initial acceleration (-4.6%/0.01%BAC) with extrapolated absolute thresholds at or below 0.01% BAC. We also found that steady-state tracking was impaired showing significant (p < 0.002) linear trends in gain (- 3.8%/0.01%BAC) and catch-up saccade amplitude (+9.1%/0.01%BAC), again with extrapolated absolute thresholds around 0.01% BAC. We also found a significant (p < 0.02) increase in pursuit direction noise (+9.8%/0.01%BAC) with an extrapolated absolute threshold below 0.01% BAC. Many aspects of ocular tracking are impaired in a dose-dependent manner beginning at a BAC level around 0.01%, with significant effects at levels lower than previously reported and up to 8-times lower than the legal limit for driving in most states.

human performance↗

Radio tracking with the Deep Space Network

Range and Doppler measurements for the Mariner 6 and 7 spacecraft are described. The Doppler tracking system and the two systems of spacecraft ranging apparatus being used in the Deep Space Network are illustrated. Charged particle calibration is considered. Equipment characteristics are presented for the ranging apparatus.

Martin, W. L.↗

Simultaneous Two-Way Doppler and Ranging for Multiple Spacecraft at Mars: Flight Radio Tracking System Design and Performance Simulations

Mars exploration requires multiple orbiters and surface infrastructures on Mars. Location determination is essential to support various human and robotic activities on the Mars surface and in orbits. Robust communication coverage is required for data transmission between assets on Mars surface and orbiters in addition to the communication between orbiters and Earth. We proposed a notional Mars Regional Navigation Satellite System (MRNSS) that provides continuous or near-continuous in-situ navigation and timing services for the robotic and human missions in the vicinity of a Mars landing site. For such a system, the Earth’s deep space stations have to perform orbit determination (OD) for the Mars orbiters so that their locations are known to a reasonable degree of accuracy. This provides the surface and orbiting user vehicles the ability to estimate their locations using the orbiter-vehicle range measurements. Two important inputs for accurate OD are 2-way Doppler and ranging measurements derived from the transmitted and received radio signals. We also introduced a new flight-ground collaborative architecture that provides simultaneous Doppler and ranging measurements for multiple spacecraft in the Mars vicinity, using an example of the Mars landing site Utopia Planitia and four Mars orbiters, all communicating with Earth via twoway communications in the X-band frequency range. One key component of this architecture is that each spacecraft uses a smart frequency sweeping algorithm that acquires and tracks the uplink signals with high Doppler and Doppler rate residuals. In this paper, we simulate the Doppler and Doppler rate profiles of the Mars orbiters of the MRNSS and assessed the acquisition and tracking performances.

Divsalar, Dariush↗

Optical Durability of Contemporary PV Encapsulants Through Artificial UV Weathering

Modern c-Si photovoltaic (PV) cells provide high performance but can be vulnerable to ultraviolet light induced degradation (UV-ID). Encapsulants, if chosen correctly, can mitigate UV-ID of the PV cell. Here, we explore performance and durability of 14 commercial encapsulant materials before, during, and after irradiation with UV-containing light. Materials include contemporary, polymer-based encapsulants with a base polymer of poly (ethylene co-vinyl acetate) (EVA), polyethylene-..alpha..-olefin (POE), or their composite (EPE). Polymers contain additives that induce UV-blocking, UV-transmitting, or UV-downshifting properties. We use test coupons to study degradation in a chamber held at 65 degrees C under a xenon light source for up to 4000 h of exposure, corresponding to a cumulative dose of 11.5 MJ/m2 at 340 nm. We examine optical properties including spectral transmittance, yellowness index and spectral fluorescence, considering changes to both the encapsulant and glass as a function of weathering time. Degradation modes identified include discoloration, changes to UV cutoff wavelength, changes to solar-weighted transmittance, and most notably a change to the UV-managing properties of some additives. We propose the use of solar-weighted transmittance in the 300- to 400-nm range to better track performance changes in the UV region associated with the UV-related additive. This is especially relevant for the emerging class of UV-downshifting additives, as metrics like UV-cutoff can understate the degree of degradation or change in these materials. While most encapsulants show very little change after weathering, some show significant changes that directly impact how much UV light would reach an underlying cell.

14 SOLAR ENERGY↗

Hydroxy-substituted electron deficient Pd porphyrin cofactors illuminate ultrafast proton transfer reactions

Coordinated electron and proton movement drive bioenergetic functions. Relative to electron transfer reactions, tracking proton transport over fast-to-ultrafast time scales is challenging. Optical resolution of proton transfer dynamics can take advantage of chromophoric photoacids that not only trigger proton migration upon photoexcitation, but produce distinct spectroscopic changes associated with protonation/deprotonation. Here, in this work, we report the design of a hydroxy-substituted electron deficient Pd porphyrin, PPd(C 6 F 5 ) 3 OH; upon photoexcitation, the acidity constant of this weak acid (pKa = 6.49) dramatically drops (pKa* = 0.97). Electronic excitation of PPd(C 6 F 5 ) 3 OH triggers an ultrafast proton transfer reaction (PPd(C 6 F 5 ) 3 OH +:B + hυ → 1[PPd(C 6 F 5 ) 3 OH]* +:B → 1 [PPd(C 6 F 5 ) 3 O]−* + HB + ; τ PT = 342 fs) to a H-bonded base (B) in solution. Both PPd(C 6 F 5 ) 3 OH and its conjugate anion PPd(C 6 F 5 ) 3 O − exhibit distinct vis-NIR spectral features for their respective ground and excited states. Because the electroni-cally excited triplet lifetimes of these species exceed tens of microseconds, the PPd(C 6 F 5 ) 3 OH photoacid defines an ideal cofactor to probe light-triggered proton release and track long-range proton migration in protein environments.

Palladium↗