Search NASA⌕ Search

SEARCH · Search NASA

Results for “two phase flow boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

VUSAT - A VERA-CS Uncertainty and Sensitivity Analysis Toolkit

VERA-CS (the Virtual Environment for Reactor Applications, Core Simulator) is a high-fidelity multiphysics core simulator under development by the Consortium for Advanced Simulation of Light Water Reactors (CASL). VERA-CS includes three main components: MPACT for reactor physics and neutron transport, COBRA-TF for thermal-hydraulics, and ORIGEN for isotopic depletion. VERA-CS has been applied to an array of problems including core physics analysis, and the modeling for all of the fuel cycles of Watts Bar Nuclear Unit 1 (WBN1). MPACT is a 3D pin-resolved reactor transport code developed by Oak Ridge National Laboratory (ORNL) and the University of Michigan. COBRA-TF (CTF) is a three-field two-phase flow subchannel analysis code developed by ORNL and North Carolina State University. CTF solves the mass, momentum, and energy equations for the liquid, vapor, and droplet phases for each subchannel in the core and captures the axial flow within each channel as well as cross-flow between channels. Direct coupling between neutronics (MPACT) and thermal-hydraulics (CTF) in VERA-CS provides temperature and density feedback. CTF includes a number of models important for LWR safety and design analysis including flow regime dependent two-phase wall heat transfer, inter-phase heat transfer and drag, droplet breakup, and quench-front tracking. ORIGEN is developed by ORNL and released through the SCALE package. ORIGEN is directly integrated in MPACT through its API to calculate the changes in nuclides for every depletable cross-section region. Uncertainties exist in safety calculations with computer codes for nuclear reactor modeling and simulation, and they come from code limitations, scaling inaccuracies embedded in the experimental data, and uncertainties associated with the state of the reactor at the initiation of the transient. Consequently, for applications of high fidelity calculations using VERA-CS, proper uncertainty quantification (UQ) and sensitivity analysis (SA) of the computing models of reactor neutronics and thermal-hydraulics are important to comprehensively understand the results. New methods in UQ and SA have to be developed in multi-physics calculations using VERA-CS. Toward this end, a software package called VUSAT which stands for VERA-CS Uncertainty and Sensitivity Analysis Toolkit has been developed to facilitate the applications of VERA-CS within the context of best estimate plus uncertainty (BEPU) analysis framework. In this work, the VUSAT application to analyze departure from nucleate boiling (DNB) is presented.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal-hydraulic Performance of Emerging Low GWP Refrigerant Mixture under Flow Boiling in Brazed Plate Heat Exchangers

The hydrofluorocarbon (HFC) refrigerants used in the current refrigeration systems are facing a phase-down due to their higher greenhouse effect resulting in global warming, and thus HVAC&R industry has undergone a transition to low Global Warming Potential (GWP) refrigerants. Refrigerant mixtures are attractive alternatives since their composition can be tailored to comply with environmental regulations while preserving favorable thermophysical properties. However, the new low-GWP zeotropic mixture refrigerants have two or more components with different saturation temperatures at the same pressure level, known as temperature glide, which can cause the degradation of the overall heat transfer performance. The brazed plate heat exchangers (BPHX) provide excellent heat transfer performance due to a compact design and are used in several air-conditioning and refrigeration applications. In this study, flow boiling heat transfer and the associated pressure drop of the refrigerant mixture in a vertical BPHX were experimentally investigated. The single-phase water-to-water experiments were conducted in the tested heat exchanger with a counter-flow configuration. The flow boiling experiments charged with R-134a and R-454C were then performed in a pumped refrigerant loop to evaluate its thermal-hydraulic performance. Furthermore, parametric studies of various heat fluxes, mass fluxes, vapor qualities, and saturation temperatures were also conducted.

Yang, Cheng-Min↗

Numerical Simulation of No-Vent Chill and Fill of a Large Liquid Hydrogen Tank

To enable the design of future in-space cryogenic propellant transfer vehicles, high accuracy models of the cryogenic propellant transfer process are desired. For in-space refueling applications, accurate simulations are desired of the propellant tank chilldown and no-vent fill (NVF) process in order to estimate the amount of propellant required, to determine the maximum sustainable flow rate to fill the tank, and to establish a timeline for the filling process. NVF is a complex process that involves numerous two-phase heat and mass transfer phenomena, such as boiling at the wall and evaporation and condensation at the liquid/vapor interface. In recent years, progress has been made in developing a numerical modeling technique using the Generalized Fluid System Simulation Program (GFSSP) that has been validated against several small-scale liquid nitrogen NVF tests. This paper presents GFSSP numerical model validation against three liquid hydrogen NVF tests on a large-scale propellant tank. Comparing the GFSSP model to the data for pressure, fill level, and wall temperature, the mean absolute percentage error is below 20% across the range of simulated conditions, indicating very good predictive agreement for this large-scale hydrogen NVF test series.

Alok Majumdar↗

Numerical Simulation of No-Vent Chill and Fill of a Large Liquid Hydrogen Tank

To enable the design of future in-space cryogenic propellant transfer vehicles, high accuracy models of the cryogenic propellant transfer process are desired. For in-space refueling applications, accurate simulations are desired of the propellant tank chilldown and no-vent fill (NVF) process in order to estimate the amount of propellant required, to determine the maximum sustainable flow rate to fill the tank, and to establish a timeline for the filling process. NVF is a complex process that involves numerous two-phase heat and mass transfer phenomena, such as boiling at the wall and evaporation and condensation at the liquid/vapor interface. In recent years, progress has been made in developing a numerical modeling technique using the Generalized Fluid System Simulation Program (GFSSP) that has been validated against several small-scale liquid nitrogen NVF tests. This paper presents GFSSP numerical model validation against three liquid hydrogen NVF tests on a large-scale propellant tank. Comparing the GFSSP model to the data for pressure, fill level, and wall temperature, the mean absolute percentage error is below 20% across the range of simulated conditions, indicating very good predictive agreement for this large-scale hydrogen NVF test series.

Alok Majumdar↗

Validation of CTF Droplet Entrainment and Annular/Mist Closure Models using Riso Steam/Water Experiments

This document summarizes the work to validate the droplet entrainment and de-entrainment models, as well as two-phase closure models in the CTF (Coolant Boiling in Rod Arrays - Two Fluids) code by comparison with experimental data obtained at Risoe National Laboratory. CTF is the modernized version of the subchannel code, COBRA-TF, being jointly developed by Oak Ridge National Laboratory and North Carolina State University for applications in the Consortium for Advanced Simulation of Light Water Reactors (CASL). The Risoe data included a series of more than 250 steam/water experiments that were performed in both tube and annulus geometries over a range of various pressures and outlet qualities. Experimental conditions were set so that the majority of cases was in the annular/mist flow regime. Measurements included liquid film flow rate, droplet flow rate, film thickness, and two-phase pressure drop. CTF was used to model 180 of the tubular geometry cases, matching experimental geometry, outlet pressure, and outlet flow quality to experimental values. CTF results were compared to the experimental data at the outlet of the test section in terms of vapor flow fractions, and entrained liquid flow fractions, and pressure drop per unit length.

42 ENGINEERING↗

Newton trust-region methods with primary variable switching for simulating high temperature multiphase porous media flow

Coupling multiphase flow with energy transport due to high temperature heat sources introduces significant new challenges since boiling and condensation processes can lead to dry-out conditions with subsequent re-wetting. The transition between two-phase and single-phase behavior can require changes to the primary dependent variables adding discontinuities as well as extending constitutive nonlinear relations to extreme physical conditions. Practical simulations of large-scale engineered domains lead to Jacobian systems with a very large number of unknowns that must be solved efficiently using iterative methods in parallel on high-performance computers. Performance assessment of potential nuclear repositories, carbon sequestration sites and geothermal reservoirs can require numerous Monte-Carlo simulations to explore uncertainty in material properties, boundary conditions, and failure scenarios. Due to the numerical challenges, standard NR iteration may not converge over the range of required simulations and require more sophisticated optimization method like trust-region. In this study, we use the open-source simulator PFLOTRAN for the important practical problem of the safety assessment of future nuclear waste repositories in the U.S. DOE geologic disposal safety assessment Framework. The simulator applies the PETSc parallel framework and a backward Euler, finite volume discretization. We demonstrate failure of the conventional NR method and the success of trust-region modifications to Newton’s method for a series of test problems of increasing complexity. Trust-region methods essentially modify the Newton step size and direction under some circumstances where the standard NR iteration can cause the solution to diverge or oscillate. Furthermore, we show how the Newton Trust-Region method can be adapted for Primary Variable Switching (PVS) when the multiphase state changes due to boiling or condensation. The simulations with high-temperature heat sources which led to extreme nonlinear processes with many state changes in the domain did not converge with NR, but they do complete successfully with the trust-region methods modified for PVS. This implementation effectively decreased weeks of simulation time needing manual adjustments to complete a simulation down to a day. Finally, we show the strong scalability of the methods on a single node and multiple nodes in an HPC cluster.

54 ENVIRONMENTAL SCIENCES↗

Implicitly solving phase appearance and disappearance problems using two-fluid six-equation model

Phase appearance and disappearance issue presents serious numerical challenges in two-phase flow simulations using the two-fluid six-equation model. Numerical challenges arise from the singular equation system when one phase is absent, as well as from the discontinuity in the solution space when one phase appears or disappears. In this work, a high-resolution spatial discretization scheme on staggered grids and fully implicit methods were applied for the simulation of two-phase flow problems using the two-fluid six-equation model. A Jacobian-free Newton-Krylov (JFNK) method was used to solve the discretized nonlinear problem. An improved numerical treatment was proposed and proved to be effective to handle the numerical challenges. The treatment scheme is conceptually simple, easy to implement, and does not require explicit truncations on solutions, which is essential to conserve mass and energy. Various types of phase appearance and disappearance problems relevant to thermal-hydraulics analysis have been investigated, including a sedimentation problem, an oscillating manometer problem, a non-condensable gas injection problem, a single-phase flow with heat addition problem and a subcooled flow boiling problem. Successful simulations of these problems demonstrate the capability and robustness of the proposed numerical methods and numerical treatments. As a result, volume fraction of the absent phase can be calculated effectively as zero.

42 ENGINEERING↗

Low-Pressure Long-Term Xenon Storage for Electric Propulsion

This Phase 2 effort demonstrated an alternative Xe storage and regulation system using activated carbon (AC) as a secondary storage media (ACSFR). This regulator system is nonmechanical, simple, inexpensive, and lighter. The ACSFR system isolates the thruster from the compressed gas tank, and allows independent multiple setpoint thruster operation. The flow using an ACSFR can also be throttled by applying increments in electrical power. Primary storage of Xe by AC is not superior to compressed gas storage with regard to weight, but AC storage can provide volume reduction, lower pressures in space, and potentially in situ Xe purification. With partial fill designs, a primary AC storage vessel for Xe could also eliminate problems with two-phase storage and regulate pressure. AC could also be utilized in long-term large quantity storage of Xe serving as a compact capture site for boil-off. Several Xe delivery ACSFR protocols between 2 and 45 sccm, and 15 min to 7 hr, were tested with an average flow variance of 1.2 percent, average power requirements of 5 W, and repeatability s of about 0.4 percent. Power requirements are affected by ACSFR bed sizing and flow rate/ duration design points, and these flow variances can be reduced by optimizing PID controller parameters.

Back, Dwight D.↗

Validation and Benchmarking of CTF For Single- And Two-Phase Flow Using VIPRE-01

As part of the Consortium for Advanced Simulation of Light Water Reactors (CASL), the subchannel code CTF is being used for single- and two-phase flow analysis under light water reactor operating conditions. Accurate determination of flow distribution, pressure drop, and void content is crucial for prediction of margins to thermal crisis and neutronic feedback, and therefore more efficient plant performance. In preparation for the intended applications, CTF has been validated against experimental facilities comprising the General Electric (GE) 3×3 bundle, the BWR Full-size Fine-mesh Bundle Tests (BFBT), the RISO tube, and the PWR Subchannel and Bundle Tests (PSBT). Meanwhile, the licensed and industrially well-recognized subchannel code VIPRE-01 is used to generate a baseline set of simulations for the targeted tests, and solution parameters are compared to CTF results. The flow split verification problem and single-phase GE 3×3 result in essentially perfect agreement between CTF and VIPRE-01. For two-phase GE 3×3 cases, flow and quality discrepancies arise in the annular-mist flow regime, yet significant improvement is observed in CTF when void drift and two-phase turbulent mixing enhancement are considered. BFBT pressure drop benchmark shows close agreement between predicted and measured results in general, although considerable over-prediction of CTF is observed at relatively high void locations of the facility. This over-estimation tendency is confirmed by RISO cases. While overall statistics are satisfactory, the BFBT bubbly/slug/churn-turbulent flow void contents are markedly over-predicted by CTF, the latter being consistent with PSBT results. Such two-phase closure terms in CTF as turbulent mixing, interfacial and wall friction, and subcooled boiling heat transfer need further improvement using more mechanistic models and high-to-low calibration techniques

Zhao, X↗

Integrated modeling of CO2 storage and leakage scenarios including transitions between super- and sub-critical conditions, and phase change between liquid and gaseous CO2

Storage of CO{sub 2} in saline aquifers is intended to be at supercritical pressure and temperature conditions, but CO{sub 2} leaking from a geologic storage reservoir and migrating toward the land surface (through faults, fractures, or improperly abandoned wells) would reach subcritical conditions at depths shallower than 500-750 m. At these and shallower depths, subcritical CO{sub 2} can form two-phase mixtures of liquid and gaseous CO{sub 2}, with significant latent heat effects during boiling and condensation. Additional strongly non-isothermal effects can arise from decompression of gas-like subcritical CO{sub 2}, the so-called Joule-Thomson effect. Integrated modeling of CO{sub 2} storage and leakage requires the ability to model non-isothermal flows of brine and CO{sub 2} at conditions that range from supercritical to subcritical, including three-phase flow of aqueous phase, and both liquid and gaseous CO{sub 2}. In this paper, we describe and demonstrate comprehensive simulation capabilities that can cope with all possible phase conditions in brine-CO{sub 2} systems. Our model formulation includes: (1) an accurate description of thermophysical properties of aqueous and CO{sub 2}-rich phases as functions of temperature, pressure, salinity and CO{sub 2} content, including the mutual dissolution of CO{sub 2} and H{sub 2}O; (2) transitions between super- and subcritical conditions, including phase change between liquid and gaseous CO{sub 2}; (3) one-, two-, and three-phase flow of brine-CO{sub 2} mixtures, including heat flow; (4) non-isothermal effects associated with phase change, mutual dissolution of CO{sub 2} and water, and (de-) compression effects; and (5) the effects of dissolved NaCl, and the possibility of precipitating solid halite, with associated porosity and permeability change. Applications to specific leakage scenarios demonstrate that the peculiar thermophysical properties of CO{sub 2} provide a potential for positive as well as negative feedbacks on leakage rates, with a combination of self-enhancing and self-limiting effects. Lower viscosity and density of CO{sub 2} as compared to aqueous fluids provides a potential for self-enhancing effects during leakage, while strong cooling effects from liquid CO{sub 2} boiling into gas, and from expansion of gas rising towards the land surface, act to self-limit discharges. Strong interference between fluid phases under three-phase conditions (aqueous - liquid CO{sub 2} - gaseous CO{sub 2}) also tends to reduce CO{sub 2} fluxes. Feedback on different space and time scales can induce non-monotonic behavior of CO{sub 2} flow rates.

54 ENVIRONMENTAL SCIENCES↗

Flow Boiling in Microgap Coolers - Suborbital Flight Results

Flow Boiling in Microgap Coolers (FBMC) is a thermal management technique that provides embedded, on-site heat removal for power dense electronic components and systems. The dielectric coolant undergoes liquid-to-vapor phase change as it passes through channels integrated within or between devices. By facilitating direct contact between the coolant and heat-generating devices and relying on phase change, the system provides tight temperature control, hot spot mitigation, very high heat transfer coefficients, and low pumping power. Ground tests demonstrated removal of high heat fluxes (up to 500 kW/m2), very high coefficients of performance (up to 40 W of heat transferred per W of pumping power), and consistent performance across five evaporator orientations under the appropriate conditions. As a follow-on study and to better assess the role of gravity on such two-phase systems, the FBMC payload was developed and flown twice aboard the Blue Origin New Shepard space vehicle in January and May 2019. Each flight exposed the payload to weightlessness (150 seconds below 0.01 g) and shorter periods of high-g during ascent (up to 3 g) and descent (up to 5 g). The flow boiling performance was consistent independent of the acceleration levels, which provides confidence that such systems will provide consistent performance when tested on the ground, orbiting or traveling through weightlessness, and operating on the surface of the Moon, Mars, and other planetary bodies. Details of the flight results, payload development, flight environment, and planned future testing will be presented.

Flow boiling↗

CFD Jet Mixing Model Validation Against Zero-Boil-Off Tank (ZBOT) Microgravity Experiment

The Zero-Boil-Off Tank (ZBOT) experiments are a series of small scale two-phase fluids physics experiments conducted aboard the International Space Station (ISS) in 2017. A goal of these experiments is to study various fundamental fluid flow, heat and mass transport, and phase change phenomena that control storage tank pressurization and pressure control in microgravity. In this paper, results of a state-of-the-art two-phase CFD (Computational Fluid Dynamics) storage tank model are presented and validated against jet mixing data provided by microgravity ZBOT experiments. Jet-ullage interaction was studied in the experiment for different jet speeds representing different flow regimes, and tank fill levels. Effects of various physical parameters, such as, jet angle, gravitational acceleration and surface tension value were investigated. Computational parameters, such as turbulence and surface tension models and interface capturing scheme, affecting jet-ullage interaction were also studied. Computational results were compared to experimental results for model validation.

Turbulence↗

CFD Jet Mixing Model Validation against Zero-Boil-Off Tank (ZBOT) Microgravity Experiment

The Zero-Boil-Off Tank (ZBOT) experiments are a series of small scale two-phase fluids physics experiments conducted aboard the International Space Station (ISS) in 2017. A goal of these experiments is to study various fundamental fluid flow, heat and mass transport, and phase change phenomena that control storage tank pressurization and pressure control in microgravity. In this paper, results of a state-of-the-art two-phase CFD storage tank model are presented and validated against jet mixing data provided by microgravity ZBOT experiments. Jet-ullage interaction was studied in the experiment for different jet speeds representing different flow regimes, and tank fill levels. Effects of various physical parameters, such as, jet angle, gravitational acceleration and surface tension value were investigated. Computational parameters, such as turbulence and surface tension models and interface capturing scheme, affecting jet-ullage interaction were also studied. Computational results were compared to experimental results for model validation.

Mixing↗

Simulation of the passive condensation cooling tank of the PASCAL test facility using the component thermal-hydraulic analysis code CUPID

For the analysis of transient two-phase flows in nuclear reactor components, a three-dimensional thermal hydraulics code, named CUPID, has been being developed. In the present study, the CUPID code was applied for the simulation of the PASCAL (PAFS Condensing Heat Removal Assessment Loop) test facility constructed with an aim of validating the cooling and operational performance of the PAFS (Passive Auxiliary Feedwater System). The PAFS is one of the advanced safety features adopted in the APR+ (Advanced Power Reactor +), which is intended to completely replace the conventional active auxiliary feedwater system. This paper presents the preliminary simulation results of the PASCAL facility performed with the CUPID code in order to verify its applicability to the thermal-hydraulic phenomena inside the system. A standalone calculation for the passive condensation cooling tank was performed by imposing a heat source boundary condition and the transient thermal-hydraulic behaviors inside the system, such as the water level, temperature and velocity, were qualitatively investigated. The simulation results verified that the natural circulation and boiling phenomena in the water pool can be well reproduced by the CUPID code. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application

Previously, we reported two-phase capillary-based cooling using narrow (200 to 1000 ..mu..m) heater bridge copper inverse opal (CIO) wicks with heat flux level of 1400 Wcm -2 and superheat ~ 10 degrees C. Here, we demonstrate the area scaling of the proposed technology to a large-area micro-cooler for high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary-wicking in a 25-..mu..m-thick CIO with an open silicon microchannel 3D-manifold for liquid delivery and vapor extraction, achieving a high heat flux ~ 400 Wcm -2 over a heated area of 10 x 10 mm 2 . For a range of inlet water flowrates from 5 to 60 g(min) -1 , we achieved total thermal resistances and vapor qualities of 0.68 cm 2 degrees CW -1 to 0.2 cm 2 degrees CW -1 and 0.55 to 0.12, respectively. The flowrates are 10x smaller than those of conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances ranges from 0.05 to 0.02 cm 2 degrees CW -1 with temperature superheat of 8 to 6 degrees C, respectively. While the overall performance of the large-area (10 x 10 mm 2 ) capillary-based micro-cooler degraded compared to the previous demonstration of the technology for a heated area of 5 x 5 mm 2 , however, preliminary CFD modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

ASSESSMENT OF MULTIPHASE CFD WITH ZERO CLOSURE MODEL FOR BOILING WATER REACTOR FUEL ASSEMBLIES

Extension of existing boiling closures to the high void fraction conditions of BWRs is one of challenges for M-CFD applications. This paper presents the assessment of an Eulerian M-CFD model with Zero closure model that has been specifically designed for two-phase flow and heat transfer applications in BWR fuel assemblies. The baseline Zero closure aims at including the simplest and most robust representation of the key physical mechanisms, rather than aiming at absolute accuracy of the predictions. The capabilities of M-CFD with Zero were evaluated against the international OECD/NRC BFBT benchmark data through the comparative analyses of local void fraction, sub-channel void fraction error and exit quality. INL high performance computing system has been employed to demonstrate the scalability of the M-CFD application to nuclear reactor fuel assemblies. The M-CFD simulation results show a good agreement with the experimental data for both quantitative and qualitative results, with the highest uncertainty being observed in the prediction of the local void fraction profile at low void fraction condition. This paper presents a recent view of the best practices for M-CFD of BWR fuel assemblies to provide a useful reference to identify and overcome common challenges in the applications of M-CFD tools. We provide recommendations for geometric modeling, mesh generation and solver configurations to optimize the methodology application.

97 MATHEMATICS AND COMPUTING↗

Validation of RELAP-7 for Forced Convective and Natural Circulation Reactor Flows

New reactor designs such as small modular reactors and newly proposed passive safety systems rely on natural circulation two-phase flow cooling of the reactor core under accident conditions. Without a pump to drive the flow, the circulation rate is a strong function of void fraction. Under these conditions where the flow rate, pressure drop, and heat transfer are all closely coupled through the mixture density, the accurate prediction of void fraction is pivotal. Furthermore, while these passive systems boast a more reliable cooling option, the sensitivity of the system to two-phase flow instabilities is more likely than in forced convective cooling and can result in dangerous density wave or flow excursion conditions. Improvement of one-dimensional system codes and further development of three-dimensional code capability are all important efforts in addressing these issues. The proposed work is a critical step towards providing confidence through validation of the capability of thermal-hydraulic tools to meet the emerging challenges in reactor simulation. Historically, system analysis codes develop a stiffness over time due to fine-tuning of adjustable code parameters that result in a reluctance or inability to adopt improved models. Therefore, a rigorous effort should be invested in preparation for RELAP-7 to identify required modeling improvements of constitutive relations and validation of the code applicability to the wide range of possible reactor flow conditions. Part of this validation involves the uncertainty quantification which is a critical step in the Code Scaling, Applicability, and Uncertainty (CSAU) methodology and Best-Estimate Plus Uncertainty (BEPU) licensing method. BEPU allows recovery of safety margins and potentially optimizing plant performance, resulting in economic benefit for the reactor operators. Beginning with the collection of past experimental data covering prototypic LWR conditions, this document reviews three critical datasets available for the validation of system codes. The experimental methods, procedures, facilities, instrumentation, and supplementary information are consolidated to aid the validation efforts of this work and future projects. These three datasets (824 conditions) are chosen due to their wide acceptance and demonstrated application for code validation. Two experimental datasets from the Nuclear Power Engineering Corporation (NUPEC) span prototypic conditions of Boiling Water Reactors (BWR) and Pressurized Water Reactors (PWR). These datasets are labeled as the BFBT (BWR Full-size Fine-mesh Bundle Test) and the PSBT (PWR Subchannel and Bundle Test) datasets respectively. The third dataset is taken in an internally heated annulus that is scaled based on a BWR subassembly and includes two-phase flows important to post-blowdown analysis. Together, the datasets consider the full range of pressure and mass flux expected in LWR forced convective flows from steady-state to long term cooling conditions. Recognizing the deficiency of available data under low-pressure, low-flow, a new natural circulation dataset consisting of 107 conditions is obtained. With system pressures ranging between 145 and 950 kPa, natural circulation is driven by a heat flux up to 275 kW/m2 in a 3 m long heated region of the annulus test section which is followed by a 2 m long unheated region before entering a condenser. Stable natural circulation flow rates in this facility were measured to be between 182 and 590 kg/m2-s. Pressure and temperature are measured at ten locations in the facility. In addition, measurements of void fraction, interfacial area concentration, and gas velocity are obtained at five axial locations in the annulus test section. The RELAP5-3D code demonstrates good accuracy for void fraction predictions in BFBT and PSBT benchmarks, but shows relatively large discrepancy in the annulus experiments at lower pressures. In two-phase natural circulation, large oscillations are observed in many system parameters during the simulation of 19 experiment cases which were conducted at low pressures, and the model shows good predictive performance with the remaining 88 experiment cases. However, some discrepancies in void fraction and temperature predictions are found which may require improved constitutive modeling under these low-pressure, low-flow condition. The quantified uncertainty in void fraction predictions in three forced convection benchmarks due to uncertainties in boundary conditions and geometries are relatively small, except for a few cases in the annulus experiment. The output uncertainty of the natural circulation model is quantified by considering the measurement error in boundary conditions, and it is shown that the output uncertainty ranges are relatively small for the range of conditions considered. Through this work, a clear pathway is provided for validation of RELAP7 once the code is available.

42 ENGINEERING↗

Microgravity two-phase flow experiment and test results

A two-phase flow system was tested in the NASA KC-135 reduced gravity test facility. Its innovative flow configuration results in an unusual ease of control and significantly reduced power and heat rejection requirements, while permitting flow regimes, pressure drops, and boiling and condensing heat transfer to be examined. Numerous design features were incorporated that minimize the impact of the KC-135 environment on system condition. Among other results, flight testing indicates no significant effect of gravity on pressure drop for the conditions examined, and that many conditions can be examined definitively only in the long-term reduced gravity afforded by a space experiment.

Hill, Wayne S.↗