Search NASA⌕ Search

SEARCH · Search NASA

Results for “visual recommendation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Progress of the enhanced Hanford single shell tank (SST) integrity project - 15497

To improve understanding of the single-shell tanks (SSTs) integrity, Washington River Protection Solutions, LLC (WRPS), the US DOE Hanford Site tank contractor, developed an enhanced Single-Shell Tank Integrity Project (SSTIP) in 2009. An expert panel on SST integrity, consisting of various subject matter experts in industry and academia, was created to provide recommendations supporting the development of the project. This panel developed 33 recommendations in four main areas of interest: structural integrity, liner degradation, leak integrity and prevention, and mitigation of contamination migration. In late 2010, seventeen of these recommendations were used to develop the basis for the M-45-10-1 Change Package for the Hanford Federal Agreement and Compliance Order, which is also known as the Tri-Party Agreement. The change package identified two phases of work for SST integrity. The initial phase was focused on efforts to envelope the integrity of the tanks. The initial phase was divided into two primary areas of investigation: structural integrity and leak integrity. If necessary, based on the outcome from the initial work, second phase would be focused on further definition of the integrity of the tanks and liners. Combined these two phases are designed to support the formal integrity assessment of the Hanford SSTs in 2018 by an Independent Qualified Registered Engineer. As the initial phase of this work completes in early 2015, this paper summarizes the project formation and status the work of the past few years associated the implementation of the Phase one recommendations. Work in the initial phase to further define the DOE's understanding of the structural integrity SSTs involved preparing a modern Analysis of Record (AOR) using finite element analysis. Structural analyses of the SSTs have been conducted since 1957, but these analyses used analog calculations, less rigorous models, or focused on individual structures. As such, an integrated understanding of all of the SSTs has not been developed to modern expectations. In support of this effort, other activities addressed the visual inspection of tank internal conditions and the collection of concrete core samples from the tanks, including a full height tank sidewall core, for analysis of current mechanics properties. The work on the liner leak integrity has examined leaks from 25 tanks with known liner failures. Individual leak assessments were developed for each tank to identify the leak cause and location and estimate historic leak rates. A common cause/failure analysis study was performed to take data from individual tanks to look for trends in the causes of failure. A separate activity is being conducted to examine the propensity for corrosion in select SSTs with aggressive waste layers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An objective determination of +Gz acceleration tolerance

Until recently, human +Gz acceleration tolerance has relied solely on subjective criteria relating to loss of vision. By use of newly developed noninvasive instrumentation using a transcutaneous Doppler flow system, objective end point criteria have been developed based on measured blood flow to the head. The system consists of miniature 8 MHz Doppler sensors (2 x 1 x 0.5 cm) placed on the forehead over both frontal branches of the temporal arteries to detect blood flow velocity from back scattered ultrasound. Its use has allowed for correlation of altered, decreased and actual reversal of eye level blood flow with subsequent central light loss. Over 100 subjects have now been studied during more than 2,000 centrifuge runs. Objective changes in temporal artery flow velocity consistently preceded visual degradation for each subject during all acceleration profiles. No subject has gone unconscious without first exhibiting a minimum 6 sec of total flow cessation. Retrograde flow followed by complete flow cessation always preceded central light loss. Results indicate that this method can be successfully used with a wide variety of tasks during exposure to +Gz acceleration. It is recommended for use during evaluation of protective maneuvers or devices on the centrifuge or during actual flight in high performance aircraft. It may also serve as a potential safety monitor during space Shuttle re-entry if there is doubt about a passenger's cardiovascular status.

Unconsciousness/prevention & control↗

Flight Test Evaluation of an Unmanned Aircraft System Traffic Management (UTM) Concept for Multiple Beyond-Visual-Line-of-Sight Operations

This study evaluates a traffic management concept designed to enable simultaneous operations of multiple small unmanned aircraft systems (UAS) in the national airspace system (NAS). A five-day flight-test activity is described that examined the feasibility of operating multiple UAS beyond visual line of sight (BVLOS) of their respective operators in the same airspace. Over the five-day campaign, three groups of five flight crews operated a total of eleven different aircraft. Each group participated in four flight scenarios involving five simultaneous missions. Each vehicle was operated BVLOS up to 1.5 miles from the pilot in command. Findings and recommendations are presented to support the feasibility and safety of routine BVLOS operations for small UAS.

UTM↗

Flight Test Evaluation of an Unmanned Aircraft System Traffic Management (UTM) Concept for Multiple Beyond-Visual-Line-of-Sight (BVLOS) Operations

This study evaluates a traffic management concept designed to enable simultaneous operations of multiple small unmanned aircraft systems (UAS) in the national airspace system (NAS). A five-day flight-test activity is described that examined the feasibility of operating multiple UAS beyond visual line of sight (BVLOS) of their respective operators in the same airspace. Over the five-day campaign, three groups of five flight crews operated a total of eleven different aircraft. Each group participated in four flight scenarios involving five simultaneous missions. Each vehicle was operated BVLOS up to 1.5 miles from the pilot in command. Findings and recommendations are presented to support the feasibility and safety of routine BVLOS operations for small UAS.

UA↗

Loosely Coupled In Situ Visualization: A Perspective on Why It's Here to Stay

In this position paper, we argue that the loosely coupled in situ processing paradigm will play an important role in high performance computing for the foreseeable future. Loosely coupled in situ is an enabling technique that addresses many of the current issues with tightly coupled in situ, including, ease-of-integration, usability, and fault tolerance. We survey the prominent positives and negatives of both tightly coupled and loosely coupled in situ and present our recommendation as to why loosely coupled in situ is an enabling technique that is here to stay. We then report on some recent experiences with loosely coupled in situ processing, in an effort to explore each of the discussed factors in a real-world environment.

Kress, James M.↗

An open source GIS tool to quantify the visual impact of wind turbines and photovoltaic panels

Although there are clear economic and environmental incentives for producing energy from solar and wind power, there can be local opposition to their installation due to their impact upon the landscape. To date, no international guidelines exist to guide quantitative visual impact assessment of these facilities, making the planning process somewhat subjective. In this paper we demonstrate the development of a method and an Open Source GIS tool to quantitatively assess the visual impact of these facilities using line-of-site techniques. The methods here build upon previous studies by (i) more accurately representing the shape of energy producing facilities, (ii) taking into account the distortion of the perceived shape and size of facilities caused by the location of the observer, (iii) calculating the possible obscuring of facilities caused by terrain morphology and (iv) allowing the combination of various facilities to more accurately represent the landscape. The tool has been applied to real and synthetic case studies and compared to recently published results from other models, and demonstrates an improvement in accuracy of the calculated visual impact of facilities. The tool is named r.wind.sun and is freely available from GRASS GIS AddOns. - Highlights: • We develop a tool to quantify wind turbine and photovoltaic panel visual impact. • The tool is freely available to download and edit as a module of GRASS GIS. • The tool takes into account visual distortion of the shape and size of objects. • The accuracy of calculation of visual impact is improved over previous methods.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Device-level plug load disaggregation in a zero energy office building and opportunities for energy savings

Along with heating, cooling, ventilation, and lighting, plug loads are one of the principal consumers of energy in commercial buildings. Managing ever-changing plug loads is a great challenge given the quantity and variety of devices in commercial buildings and the cost of monitoring equipment. To address this issue, we propose a method for developing a disaggregated model of an office building's plug loads that utilizes power data from a small portion of monitored devices and a device inventory. Using data from metering and control devices in the Research Support Facility at the National Renewable Energy Laboratory, we compared our model to the building's plug load submeters. We found that the model was effective in predicting the shape of the building's average plug loads; however, it did not account for the entire magnitude of the load. With the disaggregated breakdown, we identified devices that contributed significantly to the building's unoccupied load, such as the audio visual equipment as well as devices that contributed significantly at specific times of the day, such as the microwaves at noon. This disaggregated information enables building owners to make more informed decisions with respect to plug load controls and energy efficiency upgrades. Furthermore, we highlight how the plug loads in the Research Support Facility have changed over time and offer recommendations for implementing this disaggregation method in other buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reliable and Efficient Machine Learning (Final Technical Report)

Modern scientific experiments generate massive amounts of data at a pace much faster than humans can manually analyze. While machine learning has revolutionized commercial data analysis (such as recommending movies or recognizing faces), applying these tools to complex scientific discovery is challenging because scientific answers must be precise, interpretable, and adhere to physical laws. The research under this project aims to develop new mathematical tools and computer algorithms specifically designed for scientific applications. Major progress has been made in automatically cleaning and deconstructing messy experimental data, analyzing the visual information of physical phenomena, determining the underlying physical variables, and providing rig orous mathematical analysis of interesting algorithms and concepts widely used in machine learning. This project addressed the critical gap between our ability to generate massive scientific data and our ability to extract interpretable information from it. We established mathematical foundations for Scientific Machine Learning (SciML) aimed at effective data analytics and automated discovery. Our work focused on three core objectives: (1) developing reliable feature extraction methods for dynamic high-dimensional data, (2) establishing mathematical foundations for discovering dynamics via neural networks, and (3) creating rigorous optimization techniques for these models. Key outcomes come from two fronts. On the practical side, they include the development of algorithms that significantly enhance the extraction of signals from field data, as well as the capability to handle situations that exhibit smooth variations or physical stretching due to temperature changes. They also include the creation of an automated framework for discovering fundamental state variables from raw experimental data, demonstrating the ability to identify intrinsic physical dimensions without prior knowledge of the governing laws. On the theoretical front, the research results in theoretical advances in Optimal Transport, a widely used notion in SciML, specifically regarding functions with fixed-size nodal sets, provide sharp bounds relevant to uncertainty quantification. Meanwhile, the outcomes also include the establishment of convergence theories for nonlocal gradient descent methods, enabling robust optimization with noisy data in high-dimensional settings commonly encountered in scientific modeling. The project also helps creating opportunities to train the next generation of researchers, equipping them with the necessary technical skills for today’s workplace and preparing them for future advances.

97 MATHEMATICS AND COMPUTING↗

Transparent materials processing system

A zero gravity processing furnace system was designed that will allow acquisition of photographic or other visual information while the sample is being processed. A low temperature (30 to 400 C) test model with a flat specimen heated by quartz-halide lamps was constructed. A high temperature (400 to 1000 C) test model heated by resistance heaters, utilizing a cylindrical specimen and optics, was also built. Each of the test models is discussed in detail. Recommendations are given.

Hetherington, J. S.↗

Effects of the 8 psia / 32% O2 Atmosphere on the Human in the Spaceflight Environment

Extravehicular activity (EVA) is at the core of a manned space exploration program. There are elements of exploration that may be safely and effectively performed by robots, but there are critical elements of exploration that will require the trained, assertive, and reasoning mind of a human crewmember. To effectively use these skills, NASA needs a safe, effective, and efficient EVA component integrated into the human exploration program. The EVA preparation time should be minimized and the suit pressure should be low to accommodate EVA tasks without undue fatigue, physical discomfort, or suit-related trauma. Commissioned in 2005, the Exploration Atmospheres Working Group (EAWG) had the primary goal of recommending to NASA an internal environment that allowed efficient and repetitive EVAs for missions that were to be enabled by the former Constellation Program. At the conclusion of the EAWG meeting, the 8.0 psia and 32% oxygen (O2) environment were recommended for EVA intensive phases of missions. As a result of selecting this internal environment, NASA gains the capability for efficient EVA with low risk of decompression sickness (DCS), but not without incurring additional negative stimulus of hypobaric hypoxia to the already physiologically challenging spaceflight environment. This paper provides a literature review of the human health and performance risks associated with the 8 psia/32% O2 environment. Of most concern are the potential effects on the central nervous system including increased intracranial pressure, visual impairment, sensorimotor dysfunction, and oxidative damage. Other areas of focus include validation of the DCS mitigation strategy, incidence and treatment of acute mountain sickness (AMS), development of new exercise countermeasures protocols, effective food preparation at 8 psia, assurance of quality sleep, and prevention of suit-induced injury. As a first effort, the trade space originally considered in the EAWG was re-evaluated looking for ways to decrease the hypoxic dose by further enriching the O2% or increasing the pressure. After discussion with the NASA engineering and materials community, it was determined that the O2 could be enriched from 32% to 34% and the pressure increased from 8.0 to 8.2 psia without significant penalty. These two small changes increase alveolar O2 pressure by 11 mmHg, which is expected to significantly benefit crewmembers. The 8.2/34 environment (inspired O2 pressure = 128 mmHg) is also physiologically equivalent to the staged decompression atmosphere of 10.2 psia / 26.5% O2 (inspired O2 pressure = 127 mmHg) used on 34 different shuttle missions for approximately a week each flight. Once decided, the proposed internal environment, if different than current experience, should be evaluated through appropriately simulated research studies. In many cases, the human physiologic concerns can be investigated effectively through integrated multi-discipline ground-based studies. Although missions proposing to use an 8.2/34 environment are still years away, it is recommended that these studies begin early enough to ensure that the correct decisions pertaining to vehicle design, mission operational concepts, and human health countermeasures are appropriately informed.

Environmental control↗

The Importance of the Conformality, Heterogeneity, and Gradient Indices in Evaluating Gamma Knife Radiosurgery Treatment Plans for Intracranial Meningiomas

Purpose: To investigate the relationship between the conformality index (CIn), heterogeneity index (HIn), and gradient index (GIn) and the development of toxicity in patients treated with Gamma Knife radiosurgery (GKRS) for intracranial meningiomas. Methods and Materials: Treatment records of patients treated from 1997 to 2009 with at least 6 months of follow-up were reviewed. The following parameters were collected: CIn, HIn, GIn (ratio of the volume receiving half the prescription isodose to the volume receiving the full prescription isodose), brainstem (BS) maximum dose (MD), BS volume receiving {>=}12 Gy (V12), optic apparatus (OA) MD, OA V8 Gy, OA V10, number of isocenters, number of isocenters outside target volume, and the occurrence of six toxicities. Univariate and multivariate logistic regression modeling were used for analysis. Results: This study included 145 patients (148 meningiomas) with a median follow-up time of 27 months (range, 6-113.9 months). The majority of meningiomas were located in the skull base (53%). The median prescription dose was 13 Gy (range, 10-24 Gy) to the 51.50% (range, 50-92%) isodose. A lower HIn was correlated with a higher GIn (p = 0.007). CIn was not associated with any toxicity. Higher HIn was associated with the development of dizziness (odds ratio [OR] 1.9; p = 0.02), whereas a lower GIn was associated with motor deficits (OR 0.38; p = 0.04) and auditory changes (OR 0.59; p = 0.04). The OA MD, V8, and V12 were not associated with visual changes, but visual changes were associated with a higher number of isocenters outside the target volume (OR 1.93; p = 0.07). BS V12 was correlated with the development of auditory changes (OR 1.05; p = 0.05), whereas patients with higher BS MD tended to have increased toxicity. Conclusions: Close attention must be paid to all three indices (CIn, HIn, GIn) when optimal treatment plans are determined. We recommend that the target CIn should be {<=}2.0, the HIn {<=}2.0, and the GIn {>=}3.0 for intracranial meningiomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Studies of Alternative Ventilation Configurations to Mitigate Airborne Exposure Risks in Office Spaces

The objective of this study was to evaluate the impact of alternative ventilation configurations on airflow patterns and potential exposure risks in office spaces. Two existing conference rooms at Sandia NM were modeled using Computational Fluid Dynamics (CFD) simulations to characterize airflow patterns and potential airborne exposure risks in well-mixed and once-through (through-flow) ventilation conditions. Multiple scenarios were studied to evaluate the impact of occupancy, Plexiglass barriers, and a modified-return airflow configuration. Experimental and visualization tests were also conducted to validate the well-mixed and through-flow models and findings. The simulations demonstrated that the modified-return airflow configuration that promoted through-flow conditions reduced pathogen concentrations within the space compared to the well-mixed airflow configuration; occupancy reduction only reduced the number of exposed individuals, and Plexiglass barriers had almost no effect. The experimentally measured air speeds at nine anemometer locations generally matched the simulated airflow velocities, and a fog-purge visualization test was also consistent with simulated results of plume movement and dissipation. The visualization tests demonstrated improvements in air change rate with the modified return, which promoted through-flow conditions, versus the original well-mixed ventilation configuration. The results of this study demonstrate that minor modifications to a space that promote through-flow conditions can improve air quality and reduce pathogen concentrations. Additional airflow modeling and testing of alternative occupied space configurations are recommended to further inform room designs that mitigate airborne exposure risks for occupants.

42 ENGINEERING↗

A rate-controlled teleoperator task with simulated transport delays

A teleoperator-system simulation was used to examine the effects of two control modes (joint-by-joint and resolved-rate), a proximity-display method, and time delays (up to 2 sec) on the control of a five-degree-of-freedom manipulator performing a probe-in-hole alignment task. Four subjects used proportional rotational control and discrete (on-off) translation control with computer-generated visual displays. The proximity display enabled subjects to separate rotational errors from displacement (translation) errors; thus, when the proximity display was used with resolved-rate control, the simulated task was trivial. The time required to perform the simulated task increased linearly with time delay, but time delays had no effect on alignment accuracy. Based on the results of this simulation, several future studies are recommended.

Pennington, J. E.↗

Leonid Storm Flux Analysis From One Leonid MAC Video AL50R

A detailed meteor flux analysis is presented of a seventeen-minute portion of one videotape, collected on November 18, 1999, during the Leonid Multi-instrument Aircraft Campaign. The data was recorded around the peak of the Leonid meteor storm using an intensified CCD camera pointed towards the low southern horizon. Positions of meteors on the sky were measured. These measured meteor distributions were compared to a Monte Carlo simulation, which is a new approach to parameter estimation for mass ratio and flux. Comparison of simulated flux versus observed flux levels, seen between 1:50:00 and 2:06:41 UT, indicate a magnitude population index of r = 1.8 +/- 0.1 and mass ratio of s = 1.64 +/- 0.06. The average spatial density of the material contributing to the Leonid storm peak is measured at 0.82 +/- 0.19 particles per square kilometer per hour for particles of at least absolute visual magnitude +6.5. Clustering analysis of the arrival times of Leonids impacting the earth's atmosphere over the total observing interval shows no enhancement or clumping down to time scales of the video frame rate. This indicates a uniformly random temporal distribution of particles in the stream encountered during the 1999 epoch. Based on the observed distribution of meteors on the sky and the model distribution, recommendations am made for the optimal pointing directions for video camera meteor counts during future ground and airborne missions.

Gural, Peter S.↗

An isocenter detection and verification device for use in proton therapy

We developed a new device for isocenter detection and verification for use in proton therapy. This device can be used to confirm the isocenters of a room laser, a digital radiography system, and a rotational gantry. Agreement between the isocenters of a room laser and a digital radiography system was examined visually. We used the star-shots method for detecting and verifying the rotational gantry isocenter. The gafchromic film could be irradiated with this method using a 2 mm slitted 200 MeV proton beam. The isocenters of a room laser and digital radiography system were in good agreement. The size distribution of the isocenter by the star-shots method was <2 mm, which is the value recommended by the American Association of Physicists in Medicine Task Group 142. This new device can be used to evaluate comprehensive isocenter detection and verification for related equipment. Subsequent checking using this new device will decrease the uncertainty in measuring an isocenter. When using this device, the working time was significantly reduced to about 30 min, including preparation. These measurements should be useful for high accuracy daily treatments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The reduction of remote sensing data by visual means

Issues likely to be of concern to educators called upon to teach courses involving the reduction (interpretation) of remotely sensed data by visual means are considered. Topics covered include: (1) information requirements of those using remotely-sensed data; (2) educational concepts involved in teaching students how to generate the desired information from a visual analysis of the data; (3) principles and techniques specific to the photointerpretation process; (4) concepts involved in the making of photographic measurements, as dictated by the geometry of remote sensing imagery; (5) the nature of the various kinds of mapping, plotting, and photointerpretation equipment; and (6) some special considerations with respect to the convergence of evidence and other principles involved in the interpretation of photographs. A recommended procedure for determining the usefulness of any given type of aerial or space photography in relation to the inventory of natural resources is included.

Colwell, R. N.↗

OMV mission simulator

The Orbital Maneuvering Vehicle (OMV) will be remotely piloted during rendezvous, docking, or proximity operations with target spacecraft from a ground control console (GCC). The real-time mission simulator and graphics being used to design a console pilot-machine interface are discussed. A real-time orbital dynamics simulator drives the visual displays. The dynamics simulator includes a J2 oblate earth gravity model and a generalized 1962 rotating atmospheric and drag model. The simulator also provides a variable-length communication delay to represent use of the Tracking and Data Relay Satellite System (TDRSS) and NASA Communications (NASCOM). Input parameter files determine the graphics display. This feature allows rapid prototyping since displays can be easily modified from pilot recommendations. A series of pilot reviews are being held to determine an effective pilot-machine interface. Pilots fly missions with nominal to 3-sigma dispersions in translational or rotational axes. Console dimensions, switch type and layout, hand controllers, and graphic interfaces are evaluated by the pilots and the GCC simulator is modified for subsequent runs. Initial results indicate a pilot preference for analog versus digital displays and for two 3-degree-of-freedom hand controllers.

Cok, Keith E.↗

Design of a video system providing optimal visual information for controlling payload and experiment operations with television

A program was conducted which included the design of a set of simplified simulation tasks, design of apparatus and breadboard TV equipment for task performance, and the implementation of a number of simulation tests. Performance measurements were made under controlled conditions and the results analyzed to permit evaluation of the relative merits (effectivity) of various TV systems. Burden factors were subsequently generated for each TV system to permit tradeoff evaluation of system characteristics against performance. For the general remote operation mission, the 2-view system is recommended. This system is characterized and the corresponding equipment specifications were generated.

Source record↗