Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage loss analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A Call To Action To Engage The Community To Meet The Challenges That Must Be Tackled To Make Electrified Aircraft Propulsion Real

Technology risk reduction is essential, as it is necessary to demonstrate the potential of Electrified Aircraft Propulsion (EAP). However, more is needed for implementation. The industry is leading EAP by developing a diverse community of novel vehicles from short-haul, small, urban-focused electric vertical takeoff and landing (eVTOL) to regional air mobility (RAM) and hybrid-electric, single-aisle transport category airplanes. There are a variety of novel EAP technologies for each of these novel vehicles. And the industry is not only looking at novel technology to advance the state of the art. Instead, the industry is looking to certify these novel aircraft through their regulatory authorities, such as the US Federal Aviation Administration (FAA), the European Union Aviation Safety Authority (EASA), Transport Canada Civil Aviation (TCCA), and Brazil’s Agência Nacional de Aviação Civil (National Civil Aviation Agency, ANAC), as well as other regulatory authorities. The NASA Electrified Powertrain Flight Demonstration (EPFD) project has partnered with two industry partners to advance integrated MW-class powertrain system technology demonstration that includes an assessment of their regulatory and standards gaps in their technology. The EPFD has conducted a generic regulatory gap analysis of hybrid electric engines that aligns with the industry partners’ efforts. The EPFD regulations and standards team is integrated into the industry standards community. The international industry standards community is wrestling with critical key challenges to certification. While some certification elements are proprietary, several technology elements cut across company propriety in aircraft engines (US 14 CFR Part 33 and EASA CS-E, regulations that only reflect reciprocating and turbine engines). The approach that several of these regulatory authorities have taken is to collaborate to address their challenges. The Certification Management Team (CMT) consists of the EASA, FAA, TCCA, and ANAC, and they have begun to address common questions, such as the Loss of Power Control (LOPC) for electric engines. They have reached out to the standards community to seek answers. The industry standards development organizations (SDO) have also looked ahead to address current regulations and standards gaps. The ASTM has built key committees in its ASTM F44 General Aviation Committee and F39 Aircraft Systems Committee. The SAE has established the E-40 Electric Propulsion and AE-10 High Voltage committees.

Standards↗

Exploring Electrode-Level State-of-Charge and State-of-Health Dynamics in Lithium-Ion Battery Cells: Modeling and Experimental Identification

A computationally efficient model serves as a critical prerequisite for battery performance analysis and advanced battery management algorithm design. Although battery models that capture cell-level behavior have been widely explored in existing literature, electrode-level battery models have received much lesser attention till to date. However, such electrode-level models can significantly increase battery performance and life by enabling electrode-level health-conscious control. Such electrode-level control can effectively expand usable energy and power limits of the battery cells by utilizing the knowledge of individual electrodes' charge and health. In this context, this paper presents a comprehensive battery model developed with a reference electrode insertion that captures (i) electrode-level charge/discharge dynamics, (ii) stoichiometric and temporal dependencies of electrode-level resistances, (iii) solid electrolyte interface (SEI) layer growth as key degradation phenomenon, and (iv) capacity fade and resistance rise in each electrode due to nominal battery aging. The proposed model is identified, and a preliminary validation is performed utilizing terminal voltage and negative electrode potential data collected from a pouch cell under one continuous cycling and accelerated aging conditions where the cell experienced 14% capacity loss.

aging↗

In-situ hydrogen microstructural characterization of Si heterojunction passivation: Addressing V OC degradation and mitigation pathways

Si heterojunction (SHJ) solar cells have demonstrated record efficiency >27%, approaching the theoretical limit of ≈ 29%, primarily due to best surface/interface defect passivation provided by deposited thin layers of hydrogenated amorphous silicon (a-Si:H). Such excellent surface/interface passivation reduces recombination loss and result in >100 mV improvement of cell open circuit voltage (V OC ) to ≈ 750 mV, thus the cell efficiency. However, fielded SHJ modules exhibit loss of V OC and hence efficiency over time in years, presumably due to degradation related to a-Si:H layers. This adversely affects the technology’s market acceptance, and levelized cost of energy (LCOE). It is hypothesized that the origin of a-Si:H degradation is somehow related to the presence of weak Si–Si bonds and hydrogen in a-Si:H films. The objective of this project is to test this hypothesis by directly measuring chemical and structural changes occurring within SHJ component layers and solar cells. This is achieved by developing an innovative in-situ Fourier transform infrared (FTIR) spectrometry apparatus to monitor hydrogen microstructural changes occurring within amorphous silicon and decipher hydrogen evolution kinetics over time when samples are exposed to heat and/or light stress. These in-situ measured hydrogen microstructural changes are correlated to the changes in effective minority carrier lifetime (τ eff ), implied V OC (iV OC ), surface recombination velocity (S), and cell V OC . These mechanistic understandings will provide critical guidance to mitigate the V OC -driven degradation of SHJ solar cell performance. Passivation optimization and degradation analysis of individual SHJ component structures were achieved through systematic deposition of three symmetric structures and the completed SHJ solar cell structure. The three symmetric structures used were intrinsic a-Si:H [(i)a-Si:H] layers in a bilayer structure, intrinsic and p-type doped stacked layers [(i-p)a-Si:H] representing the front heterojunction in the SHJ cell, and intrinsic and n-typed doped stacked layers [(i-n)a-Si:H] representing the back-side back surface field (BSF) in the SHJ cell. State-of-the-art passivation qualities are demonstrated by a champion iV OC of 740 mV for the (i)a-Si:H layers, and the (i-n)a-Si:H symmetric structure. A 725 mV iV OC is observed for the (i-p)a-Si:H symmetric structure. These symmetric passivated SHJ component structures were subsequently subjected to different accelerated lifetime (ALT) stressors to identify which conditions contribute the most to iV OC degradation. Degradation of the thin (10 nm) (i)a-Si:H passivation layers without any additional overlying layers is minimal; complexity of this study arises due to unavoidable surface oxidation of (i)a-Si:H layer during most of the stress application, which is likely irrelevant for a full SHJ cell configuration with overlying protective layers. The iV OC degradation of symmetric structures is found to occur primarily at the (i-p)a-Si:H passivation stack under dark heat stress with associated hydrogen loss from the (p)a-Si:H layer. An activation energy for increase in S (defect creation) of 0.65 eV can be correlated to the activation energy of ≈ 0.4 eV for hydrogen loss from the (i-p)a-Si:H stack. This also suggests the presence of weakly bonded hydrogen in the (p)a-Si:H films, which effuses out of the film stack at such low activation energy. When light and heat stress are applied together, similar hydrogen loss from (i-p)a-Si:H stack is observed, however, does not appreciably degrade iV OC or increase S. This is an important result and departure from direct correlation between hydrogen loss and defect creation. This perhaps indicates additional defect chemistries or annealing that might be occurring in the presence of light requiring further detailed defect measurements. The full SHJ cell structure used for this project is depicted in Fig.1(d). SHJ cells with an initial V OC ≈ 700 mV were fabricated and subjected to similar ALT stress conditions. Cell V OC is found to degrade the most under dark heat stress and is confirmed by observed hydrogen migration out of the (i-p)a-Si:H stack. However, hydrogen cannot escape from the cell stack, it accumulates near the (p)a-Si:H/ITO contact interface, where ITO acts as a barrier preventing hydrogen loss. Furthermore, light-heat combined stress does not degrade V OC appreciably, confirming the occurrence of a defect annealing process.

14 SOLAR ENERGY↗

R&D to Ensure a Scientific Basis for Qualification Tests and Standards (Final Report)

Project return on investment in a photovoltaic (PV) system depends increasingly on maintaining high energy yields, and the system lifetime is a major factor in levelized cost of electricity (LCOE). Thus, the rate of PV deployment and the success of these assets depends upon reliable long-term power generation. The overarching objective of this program is to improve photovoltaic (PV) module reliability via development of tests and standards. Where reliability problems or risk are discovered, we can design tests to ensure that these liabilities don't affect future generations of products. Customers can use these tests to understand which products are susceptible to certain degradation mechanisms, and manufacturers can use the tests to design unwanted characteristics out of their products. The work under this program identifies PV reliability needs, performs characterization that provides scientific understanding of targeted degradation mechanisms, and translates those data into practical and predictive test protocols and standards. Major accomplishments include: A model for polarization-type potential induced degradation (PID-p) was developed and validated against experimental data. NREL is currently leading a new edition of IEC 62804-1 for PID detection. PID-p can cause large losses in current and voltage for some module designs on cloudy days. Finite element modeling (FEM) and experiment was used to determine when cells crack in a module. It was shown that cells in landscape orientation are much more likely to crack than those on portrait orientation. Shortly thereafter, the first products with portrait-oriented cells were introduced. Studies of how to test for light and elevated temperature degradation (LeTID) culminated with the publication of IEC TS 63342. Software to predict the progression of LeTID was developed, validated, and made publicly available. Field validated tests and international standards for durability of PV module coatings abrasion, backsheets, and encapsulants were developed. Examples are IEC 62788-1-1, IEC 62788-2 ED2, IEC TS 62788-7-2, IEC 62788-7-3 ED1, IEC 63209-2. NREL led the development a high-temperature testing technical specification, and published guidelines that enable installers to determine whether higher-temperature testing is needed, simply based on location and mounting configuration. In a number of our case studies, variations in the bills of materials or workmanship have been associated with variations in reliability. These observations emphasize the importance of quality assurance to reliability. A framework for criticality (i.e. Pareto) analysis was developed and published. The framework helps us and other researchers determine what problems should be addressed for reliability research to have the biggest industry impact. NREL continues to participate actively in international standards development and stakeholder engagement activities, including organizing an annual PV Reliability Workshop. These activities are important for ensuring we address issues that are relevant and timely, and that we convey our results to those who may benefit.

14 SOLAR ENERGY↗

Analysis and Characterization of Four-quadrant Switches based Commutation Cell

A four-quadrant switch (FQS) blocks either polarity voltage and controls current flow in both directions. Unlike voltage-source converters, in which two-quadrant switches operate over a narrow voltage range, four-quadrant switches are required to operate over a wide range of both voltage and current in applications such as matrix converters and current-source converters. Furthermore, matrix converters require multi-step commutation schemes compared to two-step schemes for current-bidirectional switch based voltage-source converters and voltage-bidirectional switch based current-source converters. This paper provides a generalized overview of commutation schemes used for two and four quadrant switches based two-level commutation cells, identifies comparison indices for FQS commutation schemes, and discusses the need for adaptive commutation-step times for wide voltage and current variation applications. Also, the static and dynamic characteristics of 1.2 kV rated FQS implementations utilizing commercial SiC MOSFETs from four different manufacturers and novel monolithic SiC BiDirectional Field Effect Transistor (BiDFET) have been reported.

Commutation cell, four quadrant switch, SiC Bidire↗

A New Configuration of Paralleled Modular ANPC Multilevel Converter Controlled by an Improved Modulation Method for 1 MHz, 1 MW EV Charger

In this work, a new configuration of the modular multilevel converter (MLC) based on the parallel connection of three-level active-neutral-point-clamped (3L-ANPC) cells as well as its improved modulation method is proposed for 1 MHz, 1 MW electric vehicle (EV) megacharger. In the proposed paralleled modular ANPC-MLC, only six high-frequency silicon carbide (SiC) power switches operating at 333 kHz are required to generate 1 MHz switching frequency spectrum. Moreover, the operating voltage of all power devices is halved, the magnitude of the first switching frequency harmonic cluster is decreased by the factor of five, and the load current is equally distributed between the 3L-ANPC legs by employing the proposed improved modulation method. Hence, the modularity, efficiency, and power density of the proposed converter are notably increased, whereas the value of passive components and the overall switching loss are remarkably decreased. In addition, an optimized design of the one 3L-ANPC cell of the proposed paralleled modular ANPC-MLC for 1 MHz, 1MW EV megacharger using Ansys SIwave, Icepak, and Q3D finite element method platforms is presented and analyzed in detail. The provided experimental results of the down-scaled setup verify the feasibility and viability of the proposed configuration as well as its improved switching pattern.

42 ENGINEERING↗

Photostability of Ambient-Processed, Conjugated Polymer Electrochromic Devices Encapsulated by Bioderived Barrier Films

Polymer-based electrochromic devices (ECDs) are a promising technology for enabling low-voltage, disposable displays, yet are currently limited by photo-oxidative bleaching of the active materials. Here, renewable barrier films composed of cellulose and chitin are presented as an alternative to poly(ethylene terephthalate) (PET) for encapsulating ECDs. To assess barrier film effectiveness, lateral ECDs composed of poly(3,4-propylenedioxythiophene-(CH 2 OEtHx) 2 ) (P(ProDOT)) active layers were constructed and encapsulated with a multilayer barrier consisting of chitin nanofibers and cellulose nanocrystals spray cast onto a cellulose acetate substrate (oxygen transmission rate (OTR) = 29 cm 3 m –2 day –1 ), a commercially available PET film (OTR = 8.5 cm 3 m –2 day –1 ), and a high-performance PET-Al 2 O 3 multilayer barrier film (OTR < 1 cm 3 m –2 day –1 ). The photodegradation of the P(ProDOT) active layer was determined by measuring the evolution of the colorimetric contrast (ΔE*) and switching speeds as a function of light exposure (100 mW cm –2 , AM 1.5 G light). Photodegradation was found to proceed at a similar rate for all encapsulated devices (roughly 10 times more slowly than unencapsulated devices), highlighting the opportunity for replacing petroleum packaging with bioderived barrier films. Analysis of the switching kinetics, the shifts in optical absorbance, and evidence of chemical degradation indicate that both photochemical breakdown of the electrolyte and cross-linking of the P(ProDOT) active material are key drivers for loss of device performance when oxygen flux to the active material is limited. Furthermore, pathways toward better understanding photodegradation are then proposed with sustainability in mind for future ECD design.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scientific Highlights and Status of the Mars Science Laboratory Mission, Years 9 through 12

We present the scientific highlights and status from years 9-12 of NASA’s Mars Science Laboratory mission, with its Curiosity rover. A thermochemolysis-based sample analysis revealed a variety of organic molecules preserved in clay mineral-rich lake/lake margin deposits of the Glen Torridon region. The stratigraphically higher clay-sulfate mineral transition on Aeolis Mons was found to be associated with a lithological change from lacustrine to dry aeolian depositional environments. Water intermittently returned to the surface after the increase in aridity, including during the deposition of wave ripple strata which indicate a climate capable of sustaining an ice-free lake in the early Hesperian. The overlying Mg sulfate-bearing unit has both poly- and monohydrated Mg sulfates and is also enriched in iron carbonate of a purity consistent with chemical sedimentation and therefore atmospheric sequestration. A channel-incised canyon within Gediz Vallis and distal alluvial deposits recorded numerous fluvial and debris flow events after the deposition, lithification, and erosion of the clay- and sulfate-bearing units. Bright clasts found in Gediz Vallis canyon are composed of native sulfur. The investigation of the modern atmosphere and environment focused on the influence of the crater and mountain topography and captured high-altitude noctilucent and iridescent clouds. Radiation monitoring now spans an 11-year solar cycle. Rover systems and science instruments remain capable of addressing mission scientific objectives. All ten scientific instruments continue to return high-value data despite degradation of the Chemistry and Camera instrument’s high-voltage system, loss of multispectral imaging capability, and loss of active neutron spectroscopy. The mission has mitigated the loss of redundant brakes on two arm joints, additional wheel wear, and highly reduced capability of the redundant flight computer. Efficiency improvements in rover energy utilization and operations staffing have allowed the mission team to maintain a high level of productivity despite declining rover power generation and funding.

Mars↗

NASA Tech Briefs, December 2007

Topics include: Ka-Band TWT High-Efficiency Power Combiner for High-Rate Data Transmission; Reusable, Extensible High-Level Data-Distribution Concept; Processing Satellite Imagery To Detect Waste Tire Piles; Monitoring by Use of Clusters of Sensor-Data Vectors; Circuit and Method for Communication Over DC Power Line; Switched Band-Pass Filters for Adaptive Transceivers; Noncoherent DTTLs for Symbol Synchronization; High-Voltage Power Supply With Fast Rise and Fall Times; Waveguide Calibrator for Multi-Element Probe Calibration; Four-Way Ka-Band Power Combiner; Loss-of-Control-Inhibitor Systems for Aircraft; Improved Underwater Excitation-Emission Matrix Fluorometer; Metrology Camera System Using Two-Color Interferometry; Design and Fabrication of High-Efficiency CMOS/CCD Imagers; Foam Core Shielding for Spacecraft CHEM-Based Self-Deploying Planetary Storage Tanks Sequestration of Single-Walled Carbon Nanotubes in a Polymer PPC750 Performance Monitor Application-Program-Installer Builder Using Visual Odometry to Estimate Position and Attitude Design and Data Management System Simple, Script-Based Science Processing Archive Automated Rocket Propulsion Test Management Online Remote Sensing Interface Fusing Image Data for Calculating Position of an Object Implementation of a Point Algorithm for Real-Time Convex Optimization Handling Input and Output for COAMPS Modeling and Grid Generation of Iced Airfoils Automated Identification of Nucleotide Sequences Balloon Design Software Rocket Science 101 Interactive Educational Program Creep Forming of Carbon-Reinforced Ceramic-Matrix Composites Dog-Bone Horns for Piezoelectric Ultrasonic/Sonic Actuators Benchtop Detection of Proteins Recombinant Collagenlike Proteins Remote Sensing of Parasitic Nematodes in Plants Direct Coupling From WGM Resonator Disks to Photodetectors Using Digital Radiography To Image Liquid Nitrogen in Voids Multiple-Parameter, Low-False-Alarm Fire-Detection Systems Mosaic-Detector-Based Fluorescence Spectral Imager Plasmoid Thruster for High Specific-Impulse Propulsion Analysis Method for Quantifying Vehicle Design Goals Improved Tracking of Targets by Cameras on a Mars Rover Sample Caching Subsystem Multistage Passive Cooler for Spaceborne Instruments GVIPS Models and Software Stowable Energy-Absorbing Rocker-Bogie Suspensions

Source record↗

Prelithiated SiO x /Graphite-NMC811 Cells: Capacity Loss, Impedance Rise and Hidden Degradation Pathways Revealed Using Three-Electrode Diagnostics

Electrodes containing SiO x /graphite (Gr) materials are attractive as anodes for high-energy lithium-ion batteries. However, their mechanical deformation, electrochemical response, and impedance evolution during long-term cycling are strongly coupled, complicating accurate diagnosis of performance fade mechanisms. In this work, the behavior of electrochemically prelithiated SiO x /Gr anodes paired with NMC811 cathodes is systematically investigated using techniques that include in-situ dilatometry, three-electrode electrochemistry, and multiscale post-cycling microscopy. The SiO x /Gr electrode exhibits a maximum expansion of 49% upon lithiation to 10 mV vs Li + /Li, with 84% of the expansion and 91% of the capacity being reversible. In full cells, relatively stable cycling with only 12% capacity fade over 500 cycles is observed. Three-electrode experiments reveal cell-level impedance growth, which is dominated by the NMC811 cathode: the SiO x /Gr anode exhibits minimal net impedance rise and an initial impedance decrease at low potentials. Despite this apparent electrochemical stability, cross-sectional SEM, PFIB tomography, and cryo-STEM reveal irreversible anode thickening caused by the accumulation of an inorganic-rich solid electrolyte interphase (SEI) permeating the anode bulk. Electrode potential-shift analysis further demonstrates that Li + ions released from lithium reservoirs in the prelithiated anode mask true lithium inventory loss during aging. These results demonstrate that low-expansion SiO x /Gr anodes can simultaneously exhibit favorable cycling and impedance metrics while undergoing substantial, hidden degradation, underscoring the importance of electrode-resolved diagnostics for evaluating prelithiated silicon-based anodes.

25 ENERGY STORAGE↗

Operational Parameters, Considerations, and Design Decisions for Resource-Constrained Ion Trap Mass Spectrometers

Mass spectrometers are increasingly finding applications in new and unique areas, often in situations where key operational resources (i.e. power, weight and size) are limited. One such example is the Mars Organic Molecule Analyzer (MOMA). This instrument is a joint venture between NASA and the European Space Agency (ESA) to develop an ion trap mass spectrometer for chemical analysis on Mars. The constraints on such an instrument are significant as are the performance requirements. While the ideal operating parameters for an ion trap are generally well characterized, methods to maintain analytical performance with limited power and system weight need to be investigated and tested. Methods Experiments have been performed on two custom ion trap mass spectrometers developed as prototypes for the MOMA instrument. This hardware consists of quadrupole ion trap electrodes that are 70% the size of common commercial instrumentation. The trapping RF voltage is created with a custom tank circuit that can be tuned over a range of RF frequencies and is driven using laboratory supplies and amplifiers. The entire instrument is controlled with custom Lab VIEW software that allows a high degree of flexibility in the definition of the scan function defining the ion trap experiment. Ions are typically generated via an internal electron ionization source, however, a laser desorption source is also in development for analysis of larger intact molecules. Preliminary Data The main goals in this work have been to reduce the power required to generate the radio frequency trapping field used in an ion trap mass spectrometer. Generally minimizing the power will also reduce the volume and mass of the electronics to support the instrument. In order to achieve optimum performance, commercial instruments typically utilize RF frequencies in the 1 MHz range. Without much concern for power usage, they simply generate the voltage required to access the mass range of interest. In order to reduce the required RF voltage (and power), operation of the ion trap at lower RF frequencies has been investigated. Surprisingly, the performance of the instrument has only been slightly degraded at RF frequencies all the way down to 500 kHz. Mass resolution is relatively stable to this point and depending on the resonant ejection point used, the peak intensity is also quite stable. To date only masses up to m/z 200 have been fully investigated, however, additional studies are planned to verify the performance with higher mass ions. The lower frequency and voltage should reduce the pseudo potential well depth, eventually affecting the trapping efficiency of the instrument -- effect that could manifest itself in significantly limiting the mass range of trapped ions. Other methods to reduce the RF power while maintaining analytical performance are also under investigation. This includes ion ejection at lower q(sub z) values to access a given mass with a lower RF voltage. The loss of mass resolution at lower q(sub eject) points has been measured and current work is underway to leverage scan speed and the use of non-linear resonances in order to counter this trend. The overall trap performance under this range of operating conditions will be presented with a goal of identifying what trade-offs are acceptable.

Danell, Ryan M.↗

Effect of electrode rinse solutions on the electrodialysis of concentrated salts

The data presented indicate that modest attention to the chemistry of the electrode rinse solution can yield as much as 56% improvement in process efficiency. When operating electrodialysis (ED) with salt concentrations greater than 10,000 mg/l (as NaCl) the amperage can be relatively high even at low voltages. To maximize the overall rate of ion transport from diluate to concentrate, there is a need to minimize resistances in the electrode cells since these can represent as much as 30% of the total resistances in the entire process and in this particular ED unit, represented resistance roughly equivalent to that within the membrane stack. This work describes the performance of a 10-cell pair, 200 cm 2 (0.02 m 2 ) per membrane, pilot ED unit operated in batch mode at 5 V potential. The feedstock to the stack was varied from 0.5% to 6% NaCl. Results from Volt-amp profiles (2.0–15 V) were used as the rationale for choosing the preferred electrode rinse solution, 90 g/l (kg/m 3 ) disodium sulfate at pH 12.5. The recommended solution of 30 g/l (kg/m 3 ) disodium sulfate at neutral pH was tested against stronger solutions (60, 90, and 120 g/l (kg/m 3 ) disodium sulfate) at neutral pH and with 1 g/l (kg/m 3 ) sodium hydroxide added to yield solutions at pH 12.5. There were stark differences in the performance of the ED unit between the solutions at pH 7 and those at pH 12.5. The slopes of the Volt-amp profiles improved indicating less resistance to ion flow at pH 12.5. Most of the difference can be attributed to the greater conductivity of sodium hydroxide compared to disodium sulfate, where even a modest addition of 1 g/l (kg/m 3 ) sodium hydroxide increased the conductivity of the solution between 8 and 20% depending on the concentration of disodium sulfate. Most notably, the initiation voltage was 2.39 ± 0.08 V with solutions at pH 7 and 1.99 V ± 0.04 V when the rinse solutions were around pH 12.5, a difference of around 0.42 V. Since the full batch runs were performed at 5.0 V, this 0.42 V differential represented a loss of 8% in process efficiency. A series of tests showed a shift in initiation voltage occurred between pH 11.5 and 12.5. Nernst equations for water electrolysis are coupled with a simple flux model that estimates the concentration of hydroxide and hydronium ions at the electrode surfaces. This model indicates that the potential demanded by the electrodes is directly linked to the current. Furthermore, there is a steep drop in the potential demanded by the anode when there is sufficient hydroxide available to generate oxygen from hydroxide as opposed to generation from water. The voltage demand is minimal at pH 12.5 and reflective of the reference standard voltage (just over 1.23 V predicted at 0.1 amps). However, the flux model predicts that the voltage demanded by the electrodes at pH 7 is 1.61 V at 0.1 amps (the lowest amperage measurable with the power pack). In conclusion, comparing this result to the reference standard (E 0 = -1.23 V) yields a satisfactory explanation for the observed difference below reference standard of 0.42 V.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Statistical Analysis of Laser Ablated Ba(Sub 0.50)Sr(Sub 0.50)TiO(Sub 3)/LaAlO(Sub 3) Films for Microwave Applications

The NASA Glenn Research Center is constructing a 616 element scanning phased array antenna using thin film Ba(sub x)Sr(sub 1-x)TiO(sub 3) based phase shifters. A critical milestone is the production of 616 identical phase shifters at 19 GHz with [asymptotically equal to]4 dB insertion loss and at least 337.5 deg phase shift with 3 percent bandwidth. It is well known that there is a direct relationship between dielectric tuning and loss due to the Kramers-Kronig relationship and that film crystallinity and strain, affected by the substrate template, play an important role. Ba(sub 0.50)Sr(sub 0.50)TiO (sub 3) films, nominally 400 nm thick, were deposited on 48 0.25 mm thick, 5 cm diameter LaAlO(sub 3) wafers. Although previous results suggested that Mn-doped films on MgO were intrinsically superior in terms of phase shift per unit loss, for this application phase shift per unit length was more important. The composition was selected as a compromise between tuning and loss for room temperature operation (e.g. crystallinity progressively degrades for Ba concentrations in excess of 30 percent). As a prelude to fabricating the array, it was necessary to process, screen, and inventory a large number of samples. Variable angle ellipsometry was used to characterize refractive index and film thickness across each wafer. Microstructural properties of the thin films were characterized using high resolution X-ray diffractometry. Finally, prototype phase shifters and resonators were patterned on each wafer and RE probed to measure tuning as a function of dc bias voltage as well as peak (0 field) permittivity and unloaded Q. The relationship among film quality and uniformity and performance is analyzed. This work presents the first statistically relevant study of film quality and microwave performance and represents a milestone towards commercialization of thin ferroelectric films for microwave applications.

Ferroelectric thin films↗

Thermal Hydraulic Experimental Test Article (FY2020 Status Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed. Since the FY19 THETA status report, the THETA primary system components have been assembled and tested using de-ionized water. Some results of this testing at select Richardson and Reynolds numbers are included herein. The custom THETA sodium flowmeter (permanent magnet submersible sodium flowmeter) has been built and calibrated using sodium in an auxiliary facility against a NIST traceable vortex shedder type flowmeter. The permanent magnet flowmeter showed excellent performance, following the theoretical equation for measured voltage quite well, with an error < 3.5% at flow rates ranging from 3-24 GPM at temperatures up to 400 °C. The secondary sodium system for heat rejection from intermediate heat exchanger has been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger have been procured.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effect of Head-Down Bed Rest and Artificial Gravity Countermeasure on Cardiac Autonomic and Advanced Electrocardiographic Function

To study the effects of 21 days of head-down bed rest (HDBR), with versus without an artificial gravity (AG) countermeasure, on cardiac autonomic and advanced electrocardiographic function. Fourteen healthy men participated in the study: seven experienced 21 days of HDBR alone ("HDBR controls") and seven the same degree and duration of HDBR but with approximately 1hr daily short-arm centrifugation as an AG countermeasure ("AG-treated"). Five minute supine high-fidelity 12-lead ECGs were obtained in all subjects: 1) 4 days before HDBR; 2) on the last day of HDBR; and 3) 7 days after HDBR. Besides conventional 12-lead ECG intervals and voltages, all of the following advanced ECG parameters were studied: 1) both stochastic (time and frequency domain) and deterministic heart rate variability (HRV); 2) beat-to-beat QT interval variability (QTV); 3) T-wave morphology, including signal-averaged T-wave residua (TWR) and principal component analysis ratios; 4) other SAECG-related parameters including high frequency QRS ECG and late potentials; and 5) several advanced ECG estimates of left ventricular (LV) mass. The most important results by repeated measures ANOVA were that: 1) Heart rates, Bazett-corrected QTc intervals, TWR, LF/HF power and the alpha 1 of HRV were significantly increased in both groups (i.e., by HDBR), but with no relevant HDBR*group differences; 2) All purely "vagally-mediated" parameters of HRV (e.g., RMSSD, HF power, Poincare SD1, etc.), PR intervals, and also several parameters of LV mass (Cornell and Sokolow-Lyon voltages, spatial ventricular activation times, ventricular gradients) were all significantly decreased in both groups (i.e., by HDBR), but again with no relevant HDBR*group differences); 3) All "generalized" or "vagal plus sympathetic" parameters of stochastic HRV (i.e., SDNN, total power, LF power) were significantly more decreased in the AG-treated group than in the HDBR-only group (i.e., here there was a relevant HDBR*group difference); and 4) QTV index was also significantly more changed (increased) in the AG-treated group than in the HDBR-only group, although this was clearly due to a greater decrease in generalized HRV and not to a greater increase in QTV proper because there was no relevant HDBR*group effect for either the SDNN or the RMSSD of QTV. Brief daily AG treatment by short-arm centrifuge during each of 21 days of HDBR does not appear to protect against HDBR-related losses of cardiac autonomic function or of LV mass as estimated by ECG.

Schlegel, T. T.↗

As‐Doped Polycrystalline CdSeTe: Localized Defects, Carrier Mobility and Lifetimes, and Impact on High‐Efficiency Solar Cells

Abstract The efficiency potential for single‐junction photovoltaics (PV) is described by the detailed balance model, which requires the elimination of nonradiative recombination and perfect minority carrier collection. Improvements in GaAs, Si, and perovskite PV follow this model. It might be more complex for CdTe, a leading thin‐film PV technology. While lifetime, passivation, and doping goals for 25% efficient CdTe solar cells are largely reached, voltage is ≈20% below the detailed balance limit. Why is that? In Se‐alloyed CdSe x Te 1‐x (Se is required for >20% efficiency) additional losses can occur due to electrostatic and bandgap fluctuations and due to electronic trap states. To understand mechanisms limiting CdSeTe solar cell performance and to suggest improvements, carrier dynamics, and transport in CdSe x Te 1‐x with variation in Se composition and as doping is analyzed. It is shown that trapping, likely due to anion‐site defects and their complexes, is correlated with low charge carrier mobility of 0.1–0.6 cm 2 (Vs) −1 . Even with 1000 ns charge carrier lifetimes, carrier diffusion length is less than the absorber thickness, reducing efficiency to ≈23%. Device simulations are used to analyze the performance of CdSe x Te 1‐x solar cells; thermodynamic models are not sufficient for absorbers with electronic disorder and trapping.

14 SOLAR ENERGY↗

Calibration, Data Acquisition, and Post Analysis of Turbulent Fluid Flow in a Calibration Jet Using Hot-wire Anemometry

The Turbine Branch concentrates on the following areas: Computational Fluid Dynamics (CFD), and implementing experimental procedures to obtain physical modeling data. Hot-wire Anemometry is a valuable tool for obtaining physical modeling data. Hot-wire Anemometry is likely to remain the principal research tool for most turbulent air/gas flow studies. The Hot-wire anemometer consists of a fine wire heated by electric current. When placed in a fluid stream, the hot-wire loses heat to the fluid by forced convection. In forced convection, energy transfer is due to molecular motion imposed by an extraneous force moving fluid parcels. When the hot-wire is in "equilibrium", the rate of heat input to the wire is equal to the rate of heat loss at the wire ends. The equality between heat input and heat loss is the basis for King s equation, which relates the electrical parameters of the hot-wire to the flow parameters of the fluid. Hot-wire anemometry is based on convective heat transfer from a heated wire element placed in a fluid flow. Any change in the fluid flow condition that affects the heat transfer from the heated element will be detected virtually instantaneously by a constant-temperature Hot-wire anemometry system. The system implemented for this research is the IFA 300. The system is a fully-integrated, thermal anemometer-based system that measures mean and fluctuating velocity components in air, water, and other fluids. It also measures turbulence and makes localized temperature measurements. A constant-temperature anemometer is a bridge and amplifier circuit that controls a tiny wire at constant temperature. As a fluid flow passes over the heated sensor, the amplifier senses the bridge off-balance and adjusts the voltage to the top of the bridge, keeping the bridge in balance. The voltage on top of the bridge can then be related to the velocity of the flow. The bridge voltage is sensitive to temperature as well as velocity and so the built-in thermocouple circuit can be attached to a thermocouple that can measure the fluid temperature. Additional information is included in the original extended abstract.

Moreno, Michelle↗

Analysis of Advanced Thermoelectric Materials and Their Functional Limits

The world's demand for energy is increasing dramatically, but the best energy conversion systems operate at approximately 30% efficiency. One way to decrease energy loss is in the recovery of waste heat using thermoelectric (TE) generators. A TE generator is device that generates electricity by exploiting heat flow across a thermal gradient. The efficiency of a TE material for power generation and cooling is determined by the dimensionless Figure of Merit (ZT): ZT = S(exp. 2)sigmaT/κ: where S is the Seebeck coefficient, sigma is the electrical conductivity, T is the absolute temperature, and κ is the thermal conductivity. The parameters are not physically independent, but intrinsically coupled since they are a function of the transport properties of electrons. Traditional research on TE materials has focused on synthesizing bulk semiconductor-type materials that have low thermal conductivity and high electrical conductivity affording ZT values of 1. The optimization of the σ/κ ratio is difficult to achieve using current material formats, as these material constants are complementary. Recent areas of research are focusing on using nanostructural artifacts that introduce specific dislocations and boundary conditions that scatter the phonons. This disrupts the physical link between thermal (phonon) and electrical (electron) transport. The result is that κ is decreased without decreasing σ. These material formats give ZT values of up to 2 which represent approximately 18% energy gain from waste heat recovery. The next challenge in developing the next generation of TE materials with superior performance is to tailor the interconnected thermoelectric physical parameters of the material system. In order to approach this problem, the fundamental physics of each parameter S, sigma, and κ need to be physically understood in their context of electron/phonon interaction for the construction of new high ZT thermoelectric devices. Is it possible to overcome the physical limit imposed by of the effect of phonon lattice oscillation and energetic electrons towards thermal conductivity? Is the Seebeck coefficient, based on the difference in voltage over temperature gradient ( deltaV/deltaT), an intrinsic parameter of each material? All these parameters were manipulated using nano-bridge and twin-lattice structural concepts at the NASA Langley Research Center. This talk will review the current trend of TE research to optimize the ZT and discuss about new approaches on increasing ZT within functional limits of each parameter.

Kim, Hyun Jung↗