Search NASA⌕ Search

SEARCH · Search NASA

Results for “volume visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

DETERMINATION OF HLW GLASS MELT RATE USING X-RAY COMPUTED TOMOGRAPHY

The purpose of the high-level waste (HLW) glass melt rate study is two-fold: (1) to gain a better understanding of the impact of feed chemistry on melt rate through bench-scale testing, and (2) to develop a predictive tool for melt rate in support of the on-going frit development efforts for the Defense Waste Processing Facility (DWPF). In particular, the focus is on predicting relative melt rates, not the absolute melt rates, of various HLW glass formulations solely based on feed chemistry, i.e., the chemistry of both waste and glass-forming frit for DWPF. Critical to the successful melt rate modeling is the accurate determination of the melting rates of various HLW glass formulations. The baseline procedure being used at the Savannah River National Laboratory (SRNL) is to; (1) heat a 4 inch-diameter stainless steel beaker containing a mixture of dried sludge and frit in a furnace for a preset period of time, (2) section the cooled beaker along its diameter, and (3) measure the average glass height across the sectioned face using a ruler. As illustrated in Figure 1-1, the glass height is measured for each of the 16 horizontal segments up to the red lines where relatively large-sized bubbles begin to appear. The linear melt rate (LMR) is determined as the average of all 16 glass height readings divided by the time during which the sample was kept in the furnace. This 'visual' method has proved useful in identifying melting accelerants such as alkalis and sulfate and further ranking the relative melt rates of candidate frits for a given sludge batch. However, one of the inherent technical difficulties of this method is to determine the glass height in the presence of numerous gas bubbles of varying sizes, which is prevalent especially for the higher-waste-loading glasses. That is, how the red lines are drawn in Figure 1-1 can be subjective and, therefore, may influence the resulting melt rates significantly. For example, if the red lines are drawn too low, a significant amount of glassy material interspersed among the gas bubbles will be excluded, thus underestimating the melt rate. Likewise, if they are drawn too high, many large voids will be counted as glass, thus overestimating the melt rate. As will be shown later in this report, there is also no guarantee that a given distribution of glass and gas bubbles along a particular sectioned plane will always be representative of the entire sample volume. Poor reproducibility seen in some LMR data may be related to these difficulties of the visual method. In addition, further improvement of the existing melt rate model requires that the overall impact of feed chemistry on melt rate be reflected on measured data at a greater quantitative resolution on a more consistent basis than the visual method can provide. An alternate method being pursued is X-ray computed tomography (CT). It involves X-ray scanning of glass samples, performing CT on the 2-D X-ray images to build 3-D volumetric data, and adaptive segmentation analysis of CT results to not only identify but quantify the distinct regions within each sample based on material density and morphologies. The main advantage of this new method is that it can determine the relative local density of the material remaining in the beaker after the heat treatment regardless of its morphological conditions by selectively excluding all the voids greater than a given volumetric pixel (voxel) size, thus eliminating much of the subjectivity involved in the visual method. As a result, the melt rate data obtained from CT scan will give quantitative descriptions not only on the fully-melted glass, but partially-melted and unmelted feed materials. Therefore, the CT data are presumed to be more reflective of the actual melt rate trends in continuously-fed melters than the visual data. In order to test the applicability of X-ray CT scan to the HLW glass melt rate study, several new series of HLW simulant/frit mixtures were melted in the Melt Rate Furnace (MRF) and the contents of each cooled but un-sectioned beaker were CT scanned and analyzed. For comparison purposes, a cross-sectional X-ray image of each sample was used to estimate the melt rate using the visual method. In order to see the impact of feed chemistry on melt rate more clearly, a total of ten frit-only glasses (i.e., no waste) were also made, CT scanned and analyzed. In addition, two historical glass series which were previously sectioned were re-joined and CT scanned; the results were then compared to the visual data obtained earlier. All the work performed on these historical samples will be documented separately in another report. This report describes the methodologies used to interpret and apply the results of X-ray CT scans to the HLW melt rate study and further highlights some of the key results on the compositional dependence of melt rate and the cross-comparison of the visual and CT results.

36 MATERIALS SCIENCE↗

Parallel streaming between heterogeneous HPC resources for real-time analysis

Performing analysis or generating visualizations concurrently with high performance simulations can yield great benefits compared to post-processing data. Writing and reading large volumes of data can be reduced or eliminated, thereby producing an I/O cost savings. One such method for concurrent simulation and analysis is in transit - streaming data from the resource running the simulation to a separate resource running the analysis. In transit analysis can be beneficial since computational resources may not have certain resources needed for visualization and analysis (e.g. GPUs) and to reduce the impact of performing analysis tasks to the run time of the simulation. When sending and receiving data in transit, data redistribution mechanisms are needed in order to support heterogeneous data layouts that may be required by the simulation and analysis applications. The work described in this paper compares two mechanisms for on-the-fly data redistribution when streaming data in parallel between two distributed memory applications. Finally, our results show that it is often more advantageous to stream data in the same layout as the sender and redistribute data amongst processes on the receiving end than to stream data in the final layout needed by the receiver.

97 MATHEMATICS AND COMPUTING↗

RCSB Protein Data Bank: visualizing groups of experimentally determined PDB structures alongside computed structure models of proteins

Recent advances in Artificial Intelligence and Machine Learning (e.g., AlphaFold, RosettaFold, and ESMFold) enable prediction of three-dimensional (3D) protein structures from amino acid sequences alone at accuracies comparable to lower-resolution experimental methods. These tools have been employed to predict structures across entire proteomes and the results of large-scale metagenomic sequence studies, yielding an exponential increase in available biomolecular 3D structural information. Given the enormous volume of this newly computed biostructure data, there is an urgent need for robust tools to manage, search, cluster, and visualize large collections of structures. Equally important is the capability to efficiently summarize and visualize metadata, biological/biochemical annotations, and structural features, particularly when working with vast numbers of protein structures of both experimental origin from the Protein Data Bank (PDB) and computationally-predicted models. Moreover, researchers require advanced visualization techniques that support interactive exploration of multiple sequences and structural alignments. This paper introduces a suite of tools provided on the RCSB PDB research-focused web portal RCSB. org, tailor-made for efficient management, search, organization, and visualization of this burgeoning corpus of 3D macromolecular structure data.

3D visualization↗

Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography

Purpose: The use of preclinical rodent models of disease continues to grow because these models help elucidate pathogenic mechanisms and provide robust test beds for drug development. Among the major anatomic and physiologic indicators of disease progression and genetic or drug modification of responses are measurements of blood vessel caliber and flow. Moreover, cardiopulmonary blood flow is a critical indicator of gas exchange. Current methods of measuring cardiopulmonary blood flow suffer from some or all of the following limitations--they produce relative values, are limited to global measurements, do not provide vasculature visualization, are not able to measure acute changes, are invasive, or require euthanasia. Methods: In this study, high-spatial and high-temporal resolution x-ray digital subtraction angiography (DSA) was used to obtain vasculature visualization, quantitative blood flow in absolute metrics (ml/min instead of arbitrary units or velocity), and relative blood volume dynamics from discrete regions of interest on a pixel-by-pixel basis (100x100 {mu}m{sup 2}). Results: A series of calibrations linked the DSA flow measurements to standard physiological measurement using thermodilution and Fick's method for cardiac output (CO), which in eight anesthetized Fischer-344 rats was found to be 37.0{+-}5.1 ml/min. Phantom experiments were conducted to calibrate the radiographic density to vessel thickness, allowing a link of DSA cardiac output measurements to cardiopulmonary blood flow measurements in discrete regions of interest. The scaling factor linking relative DSA cardiac output measurements to the Fick's absolute measurements was found to be 18.90xCO{sub DSA}=CO{sub Fick}. Conclusions: This calibrated DSA approach allows repeated simultaneous visualization of vasculature and measurement of blood flow dynamics on a regional level in the living rat.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is Image Registration of Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography for Head-and-Neck Cancer Treatment Planning Necessary?

Purpose: To evaluate dosimetry and patterns of failure related to fluorodeoxyglucose-positron emission tomography (FDG-PET)-defined biological tumor volumes (BTVs) for head-and-neck squamous cell carcinoma (HNSCC) treated with definitive radiotherapy (RT). Methods and Materials: We conducted a retrospective study of 91 HNSCC patients who received pretreatment PET/CT scans that were not formally used for target delineation. The median follow-up was 34.5 months. Image registration was performed for PET, planning CT, and post-RT failure CT scans. Previously defined primary (CT{sub PRIMARY}) and nodal (CT{sub NODE}) gross tumor volumes (GTV) were used. The primary BTV (BTV{sub PRIMARY}) and nodal BTV (BTV{sub NODE}) were defined visually (PET{sub vis}). The BTV{sub PRIMARY} was also contoured using 40% and 50% peak PET activity (PET{sub 40,} PET{sub 50}). The recurrent GTVs were contoured on post-RT CT scans. Dosimetry was evaluated on the planning-CT and pretreatment PET scan. PET and CT dosimetric/volumetric data was compared for those with and without local-regional failure (LRF). Results: In all, 29 of 91 (32%) patients experienced LRF: 10 local alone, 7 regional alone, and 12 local and regional. BTVs and CT volumes had less than complete overlap. BTVs were smaller than CT-defined targets. Dosimetric coverage was similar between failed and controlled groups as well as between BTVs and CT-defined volumes. Conclusions: PET and CT-defined tumor volumes received similar RT doses despite having less than complete overlap and the inaccuracies of image registration. LRF correlated with both CT and PET-defined volumes. The dosimetry for PET- and/or CT-based tumor volumes was not significantly inferior in patients with LRF. CT-based delineation alone may be sufficient for treatment planning in patients with HNSCC. Image registration of FDG-PET may not be necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling fuels and fire effects in 3D: Model description and applications

Scientists and managers critically need ways to assess how fuel treatments alter fire behavior, yet few tools currently exist for this purpose. In this work, we present a spatially-explicit-fuel-modeling system, FuelManager, which models fuels, vegetation growth, fire behavior (using a physics-based model, FIRETEC), and fire effects. FuelManager's flexible approach facilitates modeling fuels across a wide range of detail. Large trees or shrubs with specific coordinates are modeled as individual “Plants”, while understory plants are modeled as collections of plants called “LayerSets”. Both Plants and LayerSets contain various fuel particles (leaves, needles, twigs) with various properties including shape, size and surface area to volume ratio. A wide range of vegetation and treatments can be modeled, analyzed quantitatively and visualized in a 3D viewer. We describe the modeling approach and demonstrate fuel modeling at different levels of detail, fuel treatment and fire effects capabilities. Lastly, detailed model equations are provided in the Appendices.

54 ENVIRONMENTAL SCIENCES↗

A Semi-Supervised Learning Method for the Identification of Bad Exposures in Large Imaging Surveys

As the data volume of astronomical imaging surveys rapidly increases, traditional methods for image anomaly detection, such as visual inspection by human experts, are becoming impractical. We introduce a machine-learning-based approach to detect poor-quality exposures in large imaging surveys, with a focus on the DECam Legacy Survey (DECaLS) in regions of low extinction (i.e., E ( B − V ) < 0.04 ). Our semi-supervised pipeline integrates a vision transformer (ViT), trained via self-supervised learning (SSL), with a k-Nearest Neighbor (kNN) classifier. We train and validate our pipeline using a small set of labeled exposures observed by surveys with the Dark Energy Camera (DECam). A clustering-space analysis of where our pipeline places images labeled in good and bad categories suggests that our approach can efficiently and accurately determine the quality of exposures. Applied to new imaging being reduced for DECaLS Data Release 11, our pipeline identifies 780 problematic exposures, which we subsequently verify through visual inspection. Being highly efficient and adaptable, our method offers a scalable solution for quality control in other large imaging surveys.

Luo, Yufeng (ORCID:0000000246230683)↗

TU-F-17A-01: BEST IN PHYSICS (JOINT IMAGING-THERAPY) - An Automatic Toolkit for Efficient and Robust Analysis of 4D Respiratory Motion

Purpose: To provide an automatic image analysis toolkit to process thoracic 4-dimensional computed tomography (4DCT) and extract patient-specific motion information to facilitate investigational or clinical use of 4DCT. Methods: We developed an automatic toolkit in MATLAB to overcome the extra workload from the time dimension in 4DCT. This toolkit employs image/signal processing, computer vision, and machine learning methods to visualize, segment, register, and characterize lung 4DCT automatically or interactively. A fully-automated 3D lung segmentation algorithm was designed and 4D lung segmentation was achieved in batch mode. Voxel counting was used to calculate volume variations of the torso, lung and its air component, and local volume changes at the diaphragm and chest wall to characterize breathing pattern. Segmented lung volumes in 12 patients are compared with those from a treatment planning system (TPS). Voxel conversion was introduced from CT# to other physical parameters, such as gravity-induced pressure, to create a secondary 4D image. A demon algorithm was applied in deformable image registration and motion trajectories were extracted automatically. Calculated motion parameters were plotted with various templates. Machine learning algorithms, such as Naive Bayes and random forests, were implemented to study respiratory motion. This toolkit is complementary to and will be integrated with the Computational Environment for Radiotherapy Research (CERR). Results: The automatic 4D image/data processing toolkit provides a platform for analysis of 4D images and datasets. It processes 4D data automatically in batch mode and provides interactive visual verification for manual adjustments. The discrepancy in lung volume calculation between this and the TPS is <±2% and the time saving is by 1–2 orders of magnitude. Conclusion: A framework of 4D toolkit has been developed to analyze thoracic 4DCT automatically or interactively, facilitating both investigational and clinical use. More software tools are under development for automatic analysis of other 4D imaging modalities. This research is in part supported by NIH (U54CA137788/132378) and City Seed FY13(Grant No. 93348-14 01). AY would like to thank MSKCC summer medical student research program supported by National Cancer Institute and hosted by Department of Medical Physics at MSKCC.

60 APPLIED LIFE SCIENCES↗

THE RELATION BETWEEN GAS AND DUST IN THE TAURUS MOLECULAR CLOUD

We report a study of the relation between dust and gas over a 100 deg{sup 2} area in the Taurus molecular cloud. We compare the H{sub 2} column density derived from dust extinction with the CO column density derived from the {sup 12}CO and {sup 13}CO J = 1 {yields} 0 lines. We derive the visual extinction from reddening determined from 2MASS data. The comparison is done at an angular size of 200'' corresponding to 0.14 pc at a distance of 140 pc. We find that the relation between visual extinction A{sub V} and N(CO) is linear between A{sub V} {approx_equal} 3 and 10 mag in the region associated with the B213-L1495 filament. In other regions, the linear relation is flattened for A{sub V{approx}}> 4 mag. We find that the presence of temperature gradients in the molecular gas affects the determination of N(CO) by {approx}30%-70% with the largest difference occurring at large column densities. Adding a correction for this effect and accounting for the observed relation between the column density of CO and CO{sub 2} ices and A{sub V}, we find a linear relationship between the column of carbon monoxide and dust for observed visual extinctions up to the maximum value in our data {approx_equal}23 mag. We have used these data to study a sample of dense cores in Taurus. Fitting an analytical column density profile to these cores we derive an average volume density of about 1.4 x 10{sup 4} cm{sup -3} and a CO depletion age of about 4.2 x 10{sup 5} yr. At visual extinctions smaller than {approx}3 mag, we find that the CO fractional abundance is reduced by up to two orders of magnitude. The data show a large scatter suggesting a range of physical conditions of the gas. We estimate the H{sub 2} mass of Taurus to be about 1.5 x 10{sup 4} M{sub sun}, independently derived from the A{sub V} and N(CO) maps. We derive a CO integrated intensity to H{sub 2} conversion factor of about 2.1 x 10{sup 20} cm{sup -2} (K km s{sup -1}){sup -1}, which applies even in the region where the [CO]/[H{sub 2}] ratio is reduced by up to two orders of magnitude. The distribution of column densities in our Taurus maps resembles a log-normal function but shows tails at large and low column densities. The length scale at which the high column density tail starts to be noticeable is about 0.4 pc.

79 ASTRONOMY AND ASTROPHYSICS↗

Topological Cacti: Visualizing Contour-based Statistics

Contours, the connected components of level sets, play an important role in understanding the global structure of a scalar field. In particular their nestingbehavior and topology-often represented in form of a contour tree-have been used extensively for visualization and analysis. However, traditional contour trees onlyencode structural properties like number of contours or the nesting of contours, but little quantitative information such as volume or other statistics. Here we use thesegmentation implied by a contour tree to compute a large number of per-contour (interval) based statistics of both the function defining the contour tree as well asother co-located functions. We introduce a new visual metaphor for contour trees, called topological cacti, that extends the traditional toporrery display of acontour tree to display additional quantitative information as width of the cactus trunk and length of its spikes. We apply the new technique to scalar fields ofvarying dimension and different measures to demonstrate the effectiveness of the approach.

97 MATHEMATICS AND COMPUTING↗

Volumetric Density-Equalizing Reference Map with Applications

The density-equalizing map, a technique developed for cartogram creation, has been widely applied to data visualization but only for 2D applications. Here, we propose a novel method called the volumetric density-equalizing reference map (VDERM) for computing density-equalizing map for volumetric domains. Given a prescribed density distribution in a volumetric domain in $\mathbb{R}^3$, the proposed method continuously deforms the domain, with different volume elements enlarged or shrunk according to the density distribution. With the aid of the proposed method, medical and sociological data can be visualized via deformations of 3D objects. The method can also be applied to adaptive remeshing and shape modeling. Furthermore, by exploiting the time-dependent nature of the proposed method, applications to shape morphing can be easily achieved. Experimental results are presented to demonstrate the effectiveness of the proposed method.

97 MATHEMATICS AND COMPUTING↗

Predictive Parameters of CyberKnife Fiducial-less (XSight Lung) Applicability for Treatment of Early Non-Small Cell Lung Cancer: A Single-Center Experience

Purpose: To determine which parameters allow for CyberKnife fiducial-less tumor tracking in stereotactic body radiation therapy (SBRT) for early-stage non-small cell lung cancer. Methods and Materials: A total of 133 lung SBRT patients were preselected for direct soft-tissue tracking based on manufacturer recommendations (peripherally located tumors ≥1.5 cm with a dense appearance) and staff experience. Patients underwent a tumor visualization test to verify adequate detection by the tracking system (orthogonal radiographs). An analysis of potential predictors of successful tumor tracking was conducted looking at: tumor stage, size, histology, tumor projection on the vertebral column or mediastinum, distance to the diaphragm, lung-to-soft tissue ratio, and patient body mass index. Results: Tumor visualization was satisfactory for 88 patients (66%) and unsatisfactory for 45 patients (34%). Median time to treatment start was 6 days in the success group (range, 2-18 days) and 15 days (range, 3-63 days) in the failure group. A stage T2 (P=.04), larger tumor size (volume of 15.3 cm{sup 3} vs 6.5 cm{sup 3} in success and failure group, respectively) (P<.0001), and higher tumor density (0.86 g/cm{sup 3} vs 0.79 g/cm{sup 3}) were predictive of adequate detection. There was a 63% decrease in failure risk with every 1-cm increase in maximum tumor dimension (relative risk for failure = 0.37, CI=0.23-0.60, P=.001). A diameter of 3.6 cm predicted a success probability of 80%. Histology, lung-to-soft tissue ratio, distance to diaphragm, patient's body mass index, and tumor projection on vertebral column and mediastinum were not found to be predictive of success. Conclusions: Tumor size, volume, and density were the most predictive factors of a successful XSight Lung tumor tracking. Tumors >3.5 cm have ≥80% chance of being adequately visualized and therefore should all be considered for direct tumor tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-time data-intensive computing

Today users visit synchrotrons as sources of understanding and discovery—not as sources of just light, and not as sources of data. To achieve this, the synchrotron facilities frequently provide not just light but often the entire end station and increasingly, advanced computational facilities that can reduce terabytes of data into a form that can reveal a new key insight. The Advanced Light Source (ALS) has partnered with high performance computing, fast networking, and applied mathematics groups to create a “super-facility”, giving users simultaneous access to the experimental, computational, and algorithmic resources to make this possible. This combination forms an efficient closed loop, where data—despite its high rate and volume—is transferred and processed immediately and automatically on appropriate computing resources, and results are extracted, visualized, and presented to users or to the experimental control system, both to provide immediate insight and to guide decisions about subsequent experiments during beamtime. We will describe our work at the ALS ptychography, scattering, micro-diffraction, and micro-tomography beamlines.

43 PARTICLE ACCELERATORS↗

SU-E-J-109: Evaluation of Deformable Accumulated Parotid Doses Using Different Registration Algorithms in Adaptive Head and Neck Radiotherapy

Purpose: Three deformable image registration (DIR) algorithms are utilized to perform deformable dose accumulation for head and neck tomotherapy treatment, and the differences of the accumulated doses are evaluated. Methods: Daily MVCT data for 10 patients with pathologically proven nasopharyngeal cancers were analyzed. The data were acquired using tomotherapy (TomoTherapy, Accuray) at the PLA General Hospital. The prescription dose to the primary target was 70Gy in 33 fractions.Three DIR methods (B-spline, Diffeomorphic Demons and MIMvista) were used to propagate parotid structures from planning CTs to the daily CTs and accumulate fractionated dose on the planning CTs. The mean accumulated doses of parotids were quantitatively compared and the uncertainties of the propagated parotid contours were evaluated using Dice similarity index (DSI). Results: The planned mean dose of the ipsilateral parotids (32.42±3.13Gy) was slightly higher than those of the contralateral parotids (31.38±3.19Gy)in 10 patients. The difference between the accumulated mean doses of the ipsilateral parotids in the B-spline, Demons and MIMvista deformation algorithms (36.40±5.78Gy, 34.08±6.72Gy and 33.72±2.63Gy ) were statistically significant (B-spline vs Demons, P<0.0001, B-spline vs MIMvista, p =0.002). And The difference between those of the contralateral parotids in the B-spline, Demons and MIMvista deformation algorithms (34.08±4.82Gy, 32.42±4.80Gy and 33.92±4.65Gy ) were also significant (B-spline vs Demons, p =0.009, B-spline vs MIMvista, p =0.074). For the DSI analysis, the scores of B-spline, Demons and MIMvista DIRs were 0.90, 0.89 and 0.76. Conclusion: Shrinkage of parotid volumes results in the dose increase to the parotid glands in adaptive head and neck radiotherapy. The accumulated doses of parotids show significant difference using the different DIR algorithms between kVCT and MVCT. Therefore, the volume-based criterion (i.e. DSI) as a quantitative evaluation of registration accuracy is essential besides the visual assessment by the treating physician. This work was supported in part by the grant from Chinese Natural Science Foundation (Grant No. 11105225)

60 APPLIED LIFE SCIENCES↗

Turbulent Processes that Influence Boundary-Layer Cloud Structure (Final Technical Report)

Many models of the atmosphere simulate vertical profiles of observable fields, such as temperature, moisture, and vertical velocity. To assess the realism of such model output, it is important to evaluate the modeled profiles against observations. However, many extant evaluations consist of comparing time averaged profiles from the model and the observations. Such time averages can smooth out unrealistic features that appear in instantaneous profiles. In this way, the time averages may obscure certain model errors from detection. For instance, many models misrepresent turbulent processes, leading to profiles that are too smoothed out or too noisy. E.g., if a model has coarse vertical resolution and overly strong diffusion, then the model may be unable to produce observed sharp peaks. On the other hand, a model may have artificial approximations that produce spurious jumps in the vertical. Much can be learned by browsing through instantaneous snapshots of model output. But the volume of output produced by a global model is far too great to rely purely on visual inspection. In addition, we need a way to statistically characterize the profiles, so that anomalies can be detected more conveniently.

54 ENVIRONMENTAL SCIENCES↗

What is Data-Intensive Science?

What is Data Intensive Science? Today we are living in a digital world, where scientists often no longer interact directly with the physical object of their research, but do so via digitally captured, reduced, calibrated, analyzed, synthesized and, at times, visualized data. Advances in experimental and computational technologies have lead to an exponential growth in the volumes, variety and complexity of this data and while the deluge is not happening everywhere in an absolute sense, it is in a relative one. Science today is data intensive. Data intensive science has the potential to transform not only how we do science, but how quickly we can translate scientific progress into complete solutions, policies, decisions and ultimately economic success. Critically, data intensive science touches some of the most important challenges we are facing. Consider a few of the grand challenges outlined by the U.S. National Academy of Engineering: make solar energy economical, provide energy from fusion, develop carbon sequestration methods, advance health informatics, engineer better medicines, secure cyberspace, and engineer the tools of scientific discovery. Arguably, meeting any of these challenges requires the collaborative effort of trans-disciplinary teams, but also significant contributions from enabling data intensive technologies. Indeed for many of them, advances in data intensive research will be the single most important factor in developing successful and timely solutions. Simple extrapolations of how we currently interact with and utilize data and knowledge are not sufficient to meet this need. Given the importance of these challenges, a new, bold vision for the role of data in science, and indeed how research will be conducted in a data intensive environment is evolving.

Data Intensive Science↗

Performance characterization of microtomography with complementary metal-oxide-semiconductor detectors for computer-aided defect inspection

We developed a computer-aided defect inspection system based on computed tomography (CT). The system consists of a homemade small cone-beam CT (CBCT) system and a graphical toolbox, which is used to extract a computer-aided design (CAD) model from the CT data. In the small CBCT system, the x-ray imaging detector is based on a complementary metal-oxide-semiconductor photodiode array in conjunction with a scintillator. Imaging performance of the detector was evaluated in terms of modulation-transfer function, noise-power spectrum, and detective quantum efficiency. The tomographic imaging performance of the small CBCT system was evaluated in terms of signal-to-noise ratio and contrast-to-noise ratio. The graphical toolbox to support defect inspection incorporates various functional tools such as volume rendering, segmentation, triangular-mesh data generation, and data reduction. All the tools have been integrated in a graphical-user interface form. The developed system can provide rapid visual inspection as well as quantitative evaluation of defects by comparing the extracted CAD file with the original file, if available, of an object. The performance of the developed system is demonstrated with experimental CT volume data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Audio-Visual Biofeedback Does Not Improve the Reliability of Target Delineation Using Maximum Intensity Projection in 4-Dimensional Computed Tomography Radiation Therapy Planning

Purpose: To investigate whether coaching patients' breathing would improve the match between ITV{sub MIP} (internal target volume generated by contouring in the maximum intensity projection scan) and ITV{sub 10} (generated by combining the gross tumor volumes contoured in 10 phases of a 4-dimensional CT [4DCT] scan). Methods and Materials: Eight patients with a thoracic tumor and 5 patients with an abdominal tumor were included in an institutional review board-approved prospective study. Patients underwent 3 4DCT scans with: (1) free breathing (FB); (2) coaching using audio-visual (AV) biofeedback via the Real-Time Position Management system; and (3) coaching via a spirometer system (Active Breathing Coordinator or ABC). One physician contoured all scans to generate the ITV{sub 10} and ITV{sub MIP}. The match between ITV{sub MIP} and ITV{sub 10} was quantitatively assessed with volume ratio, centroid distance, root mean squared distance, and overlap/Dice coefficient. We investigated whether coaching (AV or ABC) or uniform expansions (1, 2, 3, or 5 mm) of ITV{sub MIP} improved the match. Results: Although both AV and ABC coaching techniques improved frequency reproducibility and ABC improved displacement regularity, neither improved the match between ITV{sub MIP} and ITV{sub 10} over FB. On average, ITV{sub MIP} underestimated ITV{sub 10} by 19%, 19%, and 21%, with centroid distance of 1.9, 2.3, and 1.7 mm and Dice coefficient of 0.87, 0.86, and 0.88 for FB, AV, and ABC, respectively. Separate analyses indicated a better match for lung cancers or tumors not adjacent to high-intensity tissues. Uniform expansions of ITV{sub MIP} did not correct for the mismatch between ITV{sub MIP} and ITV{sub 10}. Conclusions: In this pilot study, audio-visual biofeedback did not improve the match between ITV{sub MIP} and ITV{sub 10}. In general, ITV{sub MIP} should be limited to lung cancers, and modification of ITV{sub MIP} in each phase of the 4DCT data set is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗