Search NASA⌕ Search

SEARCH · Search NASA

Results for “wall systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Continuum Correlations from CFD-DEM Modeling of Conduction Heat Transfer in Granular Flows

Heat transfer between a surface and flowing particles is analyzed to improve the accuracy of continuum models for wall-to-bed heat transfer in a fluidized bed. Discrete element modeling (DEM) is used to model a fluidized bed heat exchanger where heat enters the system through a heated wall. The DEM heat transfer predictions are validated against published experimental work (Brewster et al., 2024) with less than 15% error. In previous work by Morris et al. (2015), a continuum model was developed using data from high-fidelity DEM simulations of chute flows. In the current study, the continuum model is extended and validated for fluidized beds. The sensitivity of the continuum heat transfer model parameters, which was not quantified in previous studies, is also investigated. It is observed that for a given particle with specific properties, e.g. the particle size, roughness, and conduction lens radius, the continuum correlation developed for heat transfer from a heated boundary to the particle bed depends mainly on the solid fraction or porosity of the particle bed for a given fluid. The new continuum heat transfer model is then validated over a wide range of superficial velocities via comparisons to both discrete element and experimental data. It is shown that this correlation is valid for a large range of particle flow conditions from chute flows to fluidized beds with less than 10% error as compared to DEM predictions.

14 SOLAR ENERGY↗

Resonance sound absorber with yielding wall

A single-sheet resonance system for normal incidence of sound was investigated to study in detail the effect of sympathetic vibration of the resonator front wall on sound absorption.

INSTRUMENTS - RESONATORS↗

Low-Cost, Portable, Multi-Wall Virtual Reality

Virtual reality systems make compelling outreach displays, but some such systems, like the CAVE, have design features that make their use for that purpose inconvenient. In the case of the CAVE, the equipment is difficult to disassemble, transport, and reassemble, and typically CAVEs can only be afforded by large-budget research facilities. We implemented a system like the CAVE that costs less than $30,000, weighs about 500 pounds, and fits into a fifteen-passenger van. A team of six people have unpacked, assembled, and calibrated the system in less than two hours. This cost reduction versus similar virtual-reality systems stems from the unique approach we took to stereoscopic projection. We used an assembly of optical chopper wheels and commodity LCD projectors to create true active stereo at less than a fifth of the cost of comparable active-stereo technologies. The screen and frame design also optimized portability; the frame assembles in minutes with only two fasteners, and both it and the screen pack into small bundles for easy and secure shipment.

Miller, Samuel A.↗

Efficacy of Antimicrobials on Bacteria Cultured in a Spaceflight Analogue

As humans travel in space, they will interact with microbial flora from themselves, other crewmembers, their food, and the environment. While evaluations of microbial ecology aboard the Mir and ISS suggest a predominance of common environmental flora, the presence of (and potential for) infectious agents has been well documented. Likewise, pathogens have been detected during preflight monitoring of spaceflight food, resulting in the disqualification of that production lot from flight. These environmental and food organisms range from the obligate pathogen, Salmonella enterica serovar Typhimurium (S. Typhimurium), which has been responsible for disqualification and removal of food destined for ISS and has previously been reported from Shuttle crew refuse, to the opportunistic pathogen Staphylococcus aureus, isolated numerous times from ISS habitable compartments and the crew. Infectious disease events have affected spaceflight missions, including an upper respiratory infection that delayed the launch of STS-36 and an incapacitating Pseudomonas aeruginosa urinary tract infection of a crewmember during Apollo 13. These observations indicate that the crew has the potential to be exposed to obligate and opportunistic pathogens. This risk of exposure is expected to increase with longer mission durations and increased use of regenerative life support systems. As antibiotics are the primary countermeasure after infection, determining if their efficacy during spaceflight missions is comparable to terrestrial application is of critical importance. The NASA Rotating Wall Vessel (RWV) culture system has been successfully used as a spaceflight culture analogue to identify potential alterations in several key microbial characteristics, such as virulence and gene regulation, in response to spaceflight culture. We hypothesized that bacteria cultured in the low fluid shear RWV environment would demonstrate changes in efficacy of antibiotics compared to higher fluid shear controls. This study investigated the response of three medically significant microorganisms grown in the RWV to antibiotics that could be used on spaceflight missions. Our findings suggest potential alterations in antibiotic efficacy during spaceflight and indicate that future studies on the antibiotic response require additional basic research using the RWV and/or true spaceflight. However, while this analogue has reinforced these potential alterations, the results suggest the best approach for applied forward work is evaluating an in vivo system during spaceflight, including human and rodent studies. The complex nature of the analysis for many antibiotics and organism suggests the best approach to determine in vivo responses during pharmaceutical treatment is evaluating an in vivo system during spaceflight.

Nickerson, CA↗

Nanopolysaccharide Builder: A User-Friendly Tool for Atomistic Models of Polysaccharide-Based Nanostructures

Here, we introduce Nanopolysaccharide Builder (NPB), a user-friendly software tool designed to construct polysaccharide nanostructures─mainly those based on cellulose, chitin, and chitosan─using experimental data or user-defined parameters. NPB enables the generation of cellulose and chitin allomorphs with customizable biochemical topologies and also facilitates the construction of large bundles that replicate nanostructures found in biological support systems, including plant cell walls and arthropod cuticles. The software outputs atomic Cartesian coordinates in Protein Data Bank (PDB) format and also provides atom connectivity files in PSF and PARM formats, ensuring seamless integration with major molecular dynamics (MD) engines such as NAMD, CHARMM, GROMACS, AMBER, OpenMM, and LAMMPS. Built on an interactive visualization framework, NPB features a graphical user interface (GUI) and supports both macOS and Linux operating systems. By enabling detailed atomic-scale studies of polysaccharide evolution in extracellular matrices and cell walls of algae, bacteria, fungi, and plants, NPB is poised to advance AI-guided research in sustainable chemical development and biomass utilization.

Wan, Zhangmin [Univ. of British Columbia, Vancouve↗

Flow Induced Corrosion in 6061-T6 Aluminum Pipes in De-Ionized Water Environments

Flow induced corrosion/erosion of 6061-T6 aluminum in de-ionized (DI) water environments has not been studied widely. Especially, the long-term effects of corrosion/erosion in seemingly benign flow velocity, temperature, and resistivity ranges of 8 ft/s, 85 oF, 3-5 MOhm-cm, respectively. This study concludes that the flow induced corrosion/erosion in the above parameter ranges is minimal. This is detailed by presenting a literature survey, measuring pipe wall samples from a system that has operated in the above parameter range, predict the loss of material in mm/year at the above velocities and at higher temperatures using electric potential values from other experimental studies coupled with wall shear stress simulated using Computational Fluid Dynamic (CFD) analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Plasma Facing Components with Capillary Porous System and Liquid Metal Coolant Flow

Liquid metal can create a renewable protective surface on plasma facing components (PFC), with an additional advantage of deuterium pumping and the prospect of tritium extraction if liquid lithium (LL) is used and maintained below 450 C, the temperature above which LL vapor pressure begins to contaminate the plasma. LM can also be utilized as an efficient coolant, driven by the Lorentz force created with the help of the magnetic field in fusion devices. Capillary porous systems can serve as a conduit of LM and simultaneously provide stabilization of the LM flow, protecting against spills into the plasma. Recently a combination of a fast-flowing LM cooling system with a porous plasma facing wall (CPSF) was investigated [Khodak and Maingi (2021)]. The system takes an advantage of a magnetohydrodynamics velocity profile, as well as attractive LM properties to promote efficient heat transfer from the plasma to the LL at low pumping energy cost, relative to the incident heat flux on the PFC. In case of a disruption leading to excessive heat flux from the plasma to the LM PFCs, LL evaporation can stabilize the PFC surface temperature, due to high evaporation heat and apparent vapor shielding. The proposed CPSF was optimized analytically for the conditions of a Fusion Nuclear Science Facility [Kessel et al. (2019)]: 10T toroidal field and 10 MW/m2 peak incident heat flux. Computational fluid dynamics analysis confirmed that a CPSF system with 2.5 mm square channels can pump enough LL so that no additional coolant is needed.

High Heat Flux↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution of wall conditions in utility boilers. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of a coal-fired utility boiler in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

42 ENGINEERING↗

High-Temperature Multi-Process Sensor Development and Demonstration at a Full-scale PC Combustion System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution of wall conditions in utility boilers. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of a coal-fired utility boiler in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Reynolds-number scaling of wall-pressure–velocity correlations in wall-bounded turbulence

Wall-pressure fluctuations are a practically robust input for real-time control systems aimed at modifying wall-bounded turbulence. The scaling behaviour of the wall-pressure–velocity coupling requires investigation to properly design a controller with such input data so that it can actuate upon the desired turbulent structures. A comprehensive database from direct numerical simulations (DNS) of turbulent channel flow is used for this purpose, spanning a Reynolds-number range$Re_\tau \approx 550\unicode{x2013}5200$. Spectral analysis reveals that the streamwise velocity is most strongly coupled to the linear term of the wall pressure, at a Reynolds-number invariant distance-from-the-wall scaling of$\lambda _x/y \approx 14$(and$\lambda _x/y \approx 8$for the wall-normal velocity). When extending the analysis to both homogeneous directions in$x$and$y$, the peak coherence is centred at$\lambda _x/\lambda _z \approx 2$and$\lambda _x/\lambda _z \approx 1$for$p_w$and$u$, and$p_w$and$v$, respectively. A stronger coherence is retrieved when the quadratic term of the wall pressure is concerned, but there is only little evidence for a wall-attached-eddy type of scaling. An experimental dataset comprising simultaneous measurements of wall pressure and velocity complements the DNS-based findings at one value of$Re_\tau \approx 2$k, with ample evidence that the DNS-inferred correlations can be replicated with experimental pressure data subject to significant levels of (acoustic) facility noise. It is furthermore shown that velocity-state estimations can be achieved with good accuracy by including both the linear and quadratic terms of the wall pressure. An accuracy of up to 72 % in the binary state of the streamwise velocity fluctuations in the logarithmic region is achieved; this corresponds to a correlation coefficient of$\approx$0.6. This thus demonstrates that wall-pressure sensing for velocity-state estimation – e.g. for use in real-time control of wall-bounded turbulence – has merit in terms of its realization at a range of Reynolds numbers.

Mechanics↗

Development and Demonstration of Active Noise Control Concepts

This report details design methods for and feasibility of an Active Noise Control (ANC) system using flush-wall-mounted sensors and actuators to reduce turbofan engine rotor-stator interaction noise. ANC concepts capable of suppressing discrete-tone spinning modes containing several cut-on radial mode were identified, developed analytically, and evaluated. Separate ANC systems that suppressed at least three radial modes in a cylindrical inlet duct and three radial modes in an exhaust annulus were developed. These designs resulted in inlet duct and exhaust duct tests that were performed at NASA on the 4-ft ANC Fan in the NASA Glenn AAPL facility. Effective suppression of 2-BPF spinning mode m = 2 tone noise was achieved over a range of fan speeds 1800 to 2450 rpm, where up to 4 radials were present. In the inlet duct, up to 12 dB reduction was obtained for 3 radial modes, and up to 4 dB was obtained with 4 radial modes. In the exhaust duct, up to 15 dB PWL reduction was obtained with either two or three radial modes present. Thus, the ability to suppress multiple radial modes for tones in both the inlet and exhaust ducts has been successfully demonstrated. Implications of ANC system design requirements on installation and system integration issues for ANC systems capable of suppressing higher order radial mode content when applied to a 767 using twin CF6 engines were evaluated analytically. The analytical results indicated an ANC system must be part of an integrated design to be effective.

Kraft, R.↗

MELCOR Accident Progression and Source Term Demonstration Calculations for a FHR

MELCOR is an integrated thermal hydraulics, accident progression, and source term code for reactor safety analysis that has been developed at Sandia National Laboratories for the United States Nuclear Regulatory Commission (NRC) since the early 1980s. Though MELCOR originated as a light water reactor (LWR) code, development and modernization efforts have expanded its application scope to include non-LWR reactor concepts. Current MELCOR development efforts include providing the NRC with the analytical capabilities to support regulatory readiness for licensing non-LWR technologies under Strategy 2 of the NRC's near- term Implementation Action Plans. Beginning with the Next Generation Nuclear Project (NGNP), MELCOR has undergone a range of enhancements to provide analytical capabilities for modeling the spectrum of advanced non-LWR concepts. This report describes the generic plant model developed to demonstrate MELCOR capabilities to perform fluoride-salt-cooled high-temperature reactor (FHR) safety evaluations. The generic plant model is based on publicly-available FHR design information. For plant aspects (e.g., reactor building leak rate and details of the cover-gas system) that are not described in the FHR references, the analysts made assumptions needed to construct a MELCOR full-plant model. The FHR model uses a TRi-structural ISOtropic (TRISO)-particle fuel pebble-bed reactor with a primary system rejecting heat to two coiled tube air heat ex changers. Three passive direct reactor auxiliary cooling systems provide heat removal to supplement or replace the emergency secondary system heat removal during accident conditions. Surrounding the reactor vessel is a low volume reactor cavity that insulates the reactor with fire bricks and thick concrete walls. A refractory reactor liner system provides water cooling to reduce the concrete wall temperatures. Example calculations are performed to show the plant response and MELCOR capabilities to characterize a range of accident conditions. The accidents selected for evaluation consider a range of degraded and failed modes of operation for key safety functions providing reactivity control, the primary system decay heat removal and also a piping leak of the line to the coolant drain tank.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Hematopoietic Stem Cell Therapy for Exploration of Deep Space

It is hypothesized that the hematopoietic stem cell therapy (HSCT) might countermeasure various space-caused disorders so as to maintain astronauts' homeostasis. If this were achievable, the HSCT could promote human exploration of deep space. Using animal models of disorders (hindlimb suspension unloading system and beta-thalassemia), the HSCT was tested for muscle loss, immunodeficiency and space anemia. The results indicate feasibility of HSCT for these disorders. To facilitate the HSCT in space, growth of HSCs were optimized in the NASA Rotating Wall Vessel (RWV) culture systems, including Hydrodynamic Focusing Bioreactor (HFB).

Ohi, Seigo↗

Operational experience with the Proto-DUNE NP02 and NP04 large volume liquid argon cryostats and their cryogenic systems at CERN

The far Detector of the Deep Underground Neutrino Experiment (DUNE) will be housed in several large volume (about 12.500 m$^{3}$) liquid argon cryostats. The design principle of these large cryostats, and of the cryogenic system belonging to them, are investigated through the design, construction and operation of a series of prototype installations.The Neutrino Platform 02 (NP02) and 04 (NP04) cryostats, placed at CERN, contain DUNE proto-type detectors, each of them housed in an about 600 m$^{3}$ liquid argon bath. These cryostats, based on the membrane cryostat principle, and their cryogenic systems have been designed according to the DUNE principle. Measurements performed in these test stands shall confirm the foreseen heat loads into the cryostat systems entering via its walls, via detector cabling and via the cold electronics, shall confirm the low temperature gradient over the active detector volume and shall certify the liquid argon purification principle.This paper introduces the requirements for the NP02 and NP04 cryostats and their cryogenic systems, describes the design principle applied to these two systems and gives an overview of the different modes in which the two systems have been operating. The experimental results are presented and discussed, and “lessons learned” for future installations are dawn.

43 PARTICLE ACCELERATORS↗

Residential Photovoltaic/Thermal Energy System

Proposed system supplies house with both heat and electricity. Pair of reports describes concept for self-sufficient heating, cooling, and power-generating system for house. Panels on walls of house provide hot water, space heating, and heat to charge heat-storage system, and generate electricity for circulation pumps and fans. Roof panels generate electricity for household, operate heat pump for summer cooling, and provide supplementary winter heating via heat pump, using solar-cell cooling-fluid loop. Wall and roof panels used independently.

Selcuk, M. K.↗

Maximized lateral inhibition in paired magnetic domain wall racetracks for neuromorphic computing

Lateral inhibition is an important functionality in neuromorphic computing, modeled after the biological neuron behavior that a firing neuron deactivates its neighbors belonging to the same layer and prevents them from firing. In most neuromorphic hardware platforms lateral inhibition is implemented by external circuitry, thereby decreasing the energy efficiency and increasing the area overhead of such systems. Recently, the domain wall—magnetic tunnel junction (DW-MTJ) artificial neuron is demonstrated in modeling to be intrinsically inhibitory. Without peripheral circuitry, lateral inhibition in DW-MTJ neurons results from magnetostatic interaction between neighboring neuron cells. However, the lateral inhibition mechanism in DW-MTJ neurons has not been studied thoroughly, leading to weak inhibition only in very closely-spaced devices. This work approaches these problems by modeling current- and field- driven DW motion in a pair of adjacent DW-MTJ neurons. We maximize the magnitude of lateral inhibition by tuning the magnetic interaction between the neurons. The results are explained by current-driven DW velocity characteristics in response to an external magnetic field and quantified by an analytical model. Dependence of lateral inhibition strength on device parameters is also studied. Finally, lateral inhibition behavior in an array of 1000 DW-MTJ neurons is demonstrated. Our results provide a guideline for the optimization of lateral inhibition implementation in DW-MTJ neurons. Finally, with strong lateral inhibition achieved, a path towards competitive learning algorithms such as the winner-take-all are made possible on such neuromorphic devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Computer analysis of arteriograms

A computer system has been developed to quantify the degree of atherosclerosis in the human femoral artery. The analysis involves first scanning and digitizing angiographic film, then tracking the outline of the arterial image and finally computing the relative amount of roughness or irregularity in the vessel wall. The image processing system and method are described.

Selzer, R. H.↗