Search NASA⌕ Search

SEARCH · Search NASA

Results for “water consumption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Parametric Studies of Heat Pump Water Heater Using Low GWP Refrigerants

A storage heat pump water heater (HPWH) comprises a vapor compression system and a hot water tank. It can lead to more than 70% energy saving, compared with electric resistance heating. HPWH usually uses a wrapped-tank coil as the water heater. The wrapped coil has a strong interaction with the water tank and impose a new challenge for the engineering design and simulation study. Based on the US DOE/ORNL Heat Pump Design Model (HPDM), i.e., a public-domain, component-based thermal system modelling platform, a segment-to-segment wrapped-tank coil model coupled with a one-dimensional stratified water tank model were developed, which facilitates modeling and design HPWHs having various configurations and components. Additionally, the hardware-based design model was used to evaluate refrigerants having lower global warming potentials to replace R-134a, including R-1234yf, R-1234ze, R-290, R-513A and R-450A, when effects of compressor size, refrigerant charge on 24-hour uniform energy factor (UEF) and first-hour rating (FHR) were investigated.In the drop-in replacements, R-1234ze achieved the best UEF, and R-290 resulted in the lowest UEF. When downsizing the compressor to maximize the UEFs, the UEFs of R-134a, R-290, R1234yf, R-450A and R-513A ascended to the range of 4.4 to 4.53, with R-513A having the highest UEF. The R-1234ze ended up having the lowest UEF of 4.27. Refrigerants having larger volumetric vaporization heat led to higher FHRs if using the fixed-size compressor, that R-290 resulted in the highest FHR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Invited Review Paper in Commemoration of Over 50 Years of Oxidation of Metals: Addressing the Role of Water Vapor on Long-Term Stainless Steel Oxidation Behavior

In the past 20 years, it has become clear that the long-term exposure of chromia-forming austenitic stainless steels to air containing ~ 10 vol% water vapor at 650–800 °C significantly increases the Cr consumption rate compared to laboratory air. However, a similar acceleration does not occur in 100% steam because O 2 is not available to form volatile CrO 2 (OH) 2 . As the research has shown, this accelerated Cr loss is particularly important for thin-walled components like gas turbine recuperators. Typically, conventional austenitic stainless steels exhibit accelerated attack (i.e., rapid formation of Fe-rich oxide nodules), while higher alloyed steels resist this type of degradation until the alloy surface becomes Cr depleted. The development of strategies and solutions for this issue are reviewed. Model Fe–Cr–Ni alloys have been used to study composition effects on this behavior. For example, increasing the Mn content up to ~ 4 wt% was not beneficial, but increasing the Ni content improved oxidation resistance in this environment. However, at 650–700 °C even highly alloyed steels showed surface Cr depletion at alloy grain boundaries resulting in Fe-rich oxide nodule formation. The path forward for this issue will require more refined mechanistic understanding and increased used of modeling to develop better application-specific lifetime models to identify the most cost-effective alloy solutions.

36 MATERIALS SCIENCE↗

Understanding the Dissolution and Passivation of an Aluminum Electrode during Electrocoagulation of Groundwater Using Neutron and X-ray Reflectometry

An aluminum (Al)-based electrocoagulation (EC) system can effectively remove dissolved silica and hardness in groundwater. The effectiveness of Al-EC in terms of pollutant removal, Faradaic efficiency, and energy consumption depends on the interfacial electrolysis or passivation of the electrode in water. Thus, understanding the electrolysis reaction at the liquid/electrode interface during operation is important for sustainable EC deployment. Here, a continuous flow-through Al-EC system was tested with various groundwater simulants, i.e., chloride (Cl – )-based, sulfate (SO 4 2– )-based, and mixed solutions. High pollutant removal with low energy consumption was observed in Cl – -based groundwater treatment, while low pollutant removal with high energy consumption was observed in SO 4 2– -based groundwater. For example, the required energy per unit mass of Al dosing in SO 4 2– -based groundwater is three times higher than that in Cl – -based groundwater at 10 mA/cm 2 . However, increasing the Cl – concentration significantly reduces this energy demand. In SO 4 2– -based groundwater, the silicate removal efficiency drops from 85.1% to 24.0% compared to that for Cl – -based groundwater, while Mg 2+ and Ca 2+ removal efficiencies decrease to 0.6% from 15.8% and 5.7% from 44.8%, respectively. To better understand this EC performance, we used in situ neutron reflectometry (NR) to examine the interfacial dynamics of Al dissolution and passivation at a 100 nm scale occurring on the surface of the sacrificial Al electrodes during EC. Ex situ X-ray reflectometry (XRR) was also used to support the in situ NR results. Both NR and XRR results revealed that Al dissolution is influenced by the presence of Cl – in the simulants, while a passivating layer forms on the electrode in a SO 4 2– -based solution. In the Cl – -based solution, anodic Al dissolution occurred locally and inhomogeneously across the surface of the Al anode film, resulting in a localized thickness reduction over time. In the SO 4 2– -based solution, no apparent dissolution of the Al anode was identified. Instead, Al underwent oxidation, forming an amorphous Al 2 O 3 surface layer within the Al electrode film that increased in thickness over time. In the mixed solution, both anodic Al dissolution and surface Al 2 O 3 layer formation occurred, indicating that Al dissolution and surface Al 2 O 3 layer formation are attributable to the Cl – and SO 4 2– ions, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Water-soluble saponins accumulate in drought-stressed switchgrass and may inhibit yeast growth during bioethanol production

Abstract Background Developing economically viable pathways to produce renewable energy has become an important research theme in recent years. Lignocellulosic biomass is a promising feedstock that can be converted into second-generation biofuels and bioproducts. Global warming has adversely affected climate change causing many environmental changes that have impacted earth surface temperature and rainfall patterns. Recent research has shown that environmental growth conditions altered the composition of drought-stressed switchgrass and directly influenced the extent of biomass conversion to fuels by completely inhibiting yeast growth during fermentation. Our goal in this project was to find a way to overcome the microbial inhibition and characterize specific compounds that led to this inhibition. Additionally, we also determined if these microbial inhibitors were plant-generated compounds, by-products of the pretreatment process, or a combination of both. Results Switchgrass harvested in drought (2012) and non-drought (2010) years were pretreated using Ammonia Fiber Expansion (AFEX). Untreated and AFEX processed samples were then extracted using solvents (i.e., water, ethanol, and ethyl acetate) to selectively remove potential inhibitory compounds and determine whether pretreatment affects the inhibition. High solids loading enzymatic hydrolysis was performed on all samples, followed by fermentation using engineered Saccharomyces cerevisiae . Fermentation rate, cell growth, sugar consumption, and ethanol production were used to evaluate fermentation performance. We found that water extraction of drought-year switchgrass before AFEX pretreatment reduced the inhibition of yeast fermentation. The extracts were analyzed using liquid chromatography–mass spectrometry (LC–MS) to detect compounds enriched in the extracted fractions. Saponins, a class of plant-generated triterpene or steroidal glycosides, were found to be significantly more abundant in the water extracts from drought-year (inhibitory) switchgrass. The inhibitory nature of the saponins in switchgrass hydrolysate was validated by spiking commercially available saponin standard (protodioscin) in non-inhibitory switchgrass hydrolysate harvested in normal year. Conclusions Adding a water extraction step prior to AFEX-pretreatment of drought-stressed switchgrass effectively overcame inhibition of yeast growth during bioethanol production. Saponins appear to be generated by the plant as a response to drought as they were significantly more abundant in the drought-stressed switchgrass water extracts and may contribute toward yeast inhibition in drought-stressed switchgrass hydrolysates.

59 BASIC BIOLOGICAL SCIENCES↗

Emerging Technologies Review: Water Reuse Systems for Cooling Tower Applications

This report explores the concept of water reuse systems for cooling tower water makeup, specifically focusing on the use of alternative water sources, and the viability of these systems for Air Force installations and operations. Cooling is a critical requirement for DAF operations, and alternative water supplies that enable cooling tower use during a disruption of utility-supplied water increase Air Force resilience. The components of a water reuse system for cooling towers include alternative water supplies, storage, treatment, and distribution in addition to the cooling tower itself. Alternative water sources are not derived from fresh surface water or groundwater and can provide a redundant water supply to utility supply or to fresh water produced on site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Crossing the Finish Line: Integration of Data-Driven Process Control for Maximization of Energy and Resource Efficiency in Advanced Water Resource Recovery Facilities

Improvements in process monitoring and control at water resource recovery facilities (WRRFs) could result in reductions in electricity consumption, chemical inputs, and greenhouse gas emissions, as well as improved energy recovery. Many current WRRF data collection, monitoring, and control approaches use 20th century process monitoring and control systems, which require large design safety factors to ensure reliability in the absence of more advanced, precise controls. Implementation of more modern data-driven control tools could lead to more efficient operations that provide intrinsic reliability with better overall process performance at full-scale. This presentation provides an overview of a recently initiated project "Crossing the Finish Line: Integration of Data-Driven Process Control for Maximization of Energy and Resource Efficiency in Advanced Water Resource Recovery Facilities" which will (1) develop and demonstrate data-driven process controls at full-scale facilities for five promising WRRF Applications (i.e., process technologies) that provide whole-plant approaches and offer substantial energy and resource recovery benefits, and (2) create a toolbox of new process control approaches and an implementation guide including five examples for application at utilities. The presentation also provides a detailed overview of the research approach and progress being made on one of the five Applications, namely Application 2: Biological Nutrient Removal (BNR): ammonium-based aeration control (ABAC) / ammonia vs. NOx (AvN) + partial denitration with anammox (PdNA), which is being implemented at Hampton Roads Sanitation District. This project is a collaboration of work being conducted by DC Water, Hampton Roads Sanitation District, Metro Water Recovery, University of Michigan, Northwestern University, US Military Academy - West Point, Black & Veatch, and Oak Ridge National Laboratory. Research partner: U.S. Department of Energy.

54 ENVIRONMENTAL SCIENCES↗

Process intensification of CO 2 capture by low-aqueous solvent

Low-energy solvent-based CO 2 absorption processes have drawn attention as a next-generation post-combustion CO 2 capture technology to reduce CO2 emissions from fossil fuel– or biomass-fired power generation and industrial flue gas streams. A low-aqueous (or water-lean) solvent process may substantially reduce the thermal energy consumption for solvent regeneration. Low-aqueous solvent–based processes are thermally sensitive, requiring a delicate temperature control within the absorber because of the fast exothermic amine-CO 2 reaction and low heat capacity organic diluent. This reaction may result in heat accumulation in a packed absorption column and undesirable CO 2 desorption occurring as the solvent moves through the column, reducing the solvent’s CO 2 capture efficiency if its temperature is not controlled. Using a 3D printed intensified packing device, enhanced heat and mass transfer were demonstrated in an amine-CO 2 scrubbing process using low-aqueous solvent. The multifunctional intensified device facilitates contact of the reactive solvent and gas phases in a single stage and heat removal by a cooling fluid flowing through channels in the interior of the corrugated plates of the device. These functionalities led to effective thermal management along the column via intrastage cooling and significant improvement in CO 2 uptake under a wide range of operating conditions. Intrastage cooling effectively reduced the solvent average temperature along the column by ~10 °C and, as a result, the solvent’s capture efficiency improved by up to 25%.

42 ENGINEERING↗

The cost savings potential of controlling solar thermal collectors with storage for time-of-use electricity rates

Homes and commercial buildings account for roughly 40% of U.S. energy consumption. A significant portion of this energy consumption, and therefore utility cost, comes from domestic hot-water use. Solar collectors such as flat plate collectors, evacuated tubes, and combined photovoltaic/thermal panels, are renewable options that collect thermal energy and could help reduce utility costs. Hot water is generated by pumping a working fluid through the solar collector, where the fluid captures thermal energy via absorbed solar radiation incident on the collector surface. The collection of heat coincides with the availability of solar radiation, but the best time to use this thermal energy depends on the utility rate at a given time, which often changes throughout the day. In this work, we implement and simulate a control strategy using Transient System Simulation Tool (TRNSYS) that reduces utility costs by controlling when the system stores and uses thermal energy based on solar availability and time-of-use electricity rates. Our modeled results show that the control strategy can reduce utility costs associated with using hot water between 3% and 30%. Here, we also show how the on-peak utility rates, the size and type of the solar collectors, and the location's climate impact the results.

14 SOLAR ENERGY↗

The levelized cost of exergy: a technoeconomic framework for energy system comparison

While the levelized costs of electricity and heat have been quantified before, these two metrics cannot be directly compared, due to the different exergy content of heat and work. To address this, we develop a levelized cost of exergy (LCOEx) framework that enables direct comparisons between energy sources and processes. We find that moderate- and high-grade heat have an LCOEx that is comparable to electricity (5–10 ¢ per kWh ex ), while low-grade heat sources have much higher LCOEx values (>50 ¢ per kWh ex ). The LCOEx of a system's output is affected by (i) the LCOEx of the system input, (ii) the CAPEX of the system, and (iii) the exergetic efficiency of the system. We use our framework to identify which processes are already achieved with relatively high cost effectiveness (production of fuels, hydrogen, and ammonia) and which have room for improvement (dehumidification, food production).

08 HYDROGEN↗

Competitiveness Assessment of Decarbonizing Electricity and Process Heat Supply to a Campus with a Small Nuclear Reactor

This paper analyzes the competitiveness of siting a small nuclear reactor to support decarbonization of sites requiring tens of MW of electricity and/or process heat to support centralized heating and cooling system. This paper focuses on campuses as representative of sites with collections of buildings and research facilities with decarbonization needs represented by buildings heating, and electricity consumption by electrical loads which may include cooling via chilled water (e.g., for air conditioning and to cool down computer clusters). A nuclear reactor can be considered to decarbonize a site’s high-temperature steam generation used mostly for building heating needs, climate control, and hot water, by supplying process heat capabilities, while electricity decarbonization would be achieved mostly by the grid. However, a secondary application can be considered to maximize reactor utilization and avoid ramping down the reactor if the steam demand varies significantly throughout the year. Chilled water generation through steam-driven systems was identified as an attractive secondary option for the site analyzed, due to potential for plant design simplification, while electricity generation could be considered as well to reduce electricity purchases for a wider range of site applications. For a campus with peak 60MW thermal power demand, a small nuclear reactor with similar thermal power rating would almost eliminate CO2 emissions from steam generation and reduce electricity imports for chilled water production. A preliminary techno-economic feasibility study shows that a small nuclear reactor design that is optimized to support process heat can represent an economically feasible option when compared with other decarbonization alternatives.

Stauff, Nicolas E.↗

Community and Passenger Survey Responses for Bastrop, Texas Low-Speed Electric Vehicle Mobility Service Project

This document describes the contents of the following data products: 1. ALL-survey_results_NREL_LiveWire_04_14_2023 (Excel file with two worksheets) 2. eCab_DOE_NREL_LiveWire_04_14_2023_results_all_surveys_except_SP_csv (CSV file) 3. eCab_DOE_NREL_LiveWire_04_14_2023_SP_survey_results_only_csv (CSV file). These data products contain the results of the surveys conducted throughout the DOE-funded Electric First-/Last-Mile On-Demand Shuttle Service for Rural Communities in Central Texas project. The Excel file is the original database of all the survey results (contained in two worksheets). The CSV files are those two worksheets saved as individual CSV files.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coastal inundation regime moderates the short-term effects of sediment and soil additions on seawater oxygen and greenhouse gas dynamics: a microcosm experiment

The frequency and persistence of tidal inundation varies along the coastal terrestrial-aquatic interface, from frequently inundated wetlands to rarely inundated upland forests. This inundation gradient controls soil and sediment biogeochemistry and influence the exchange of soils and sediments from terrestrial to aquatic domains. Although a rich literature exist on studies of the influence of tidal waters on the biogeochemistry of coastal ecosystem soils, few studies have experimentally addressed the reverse question: How do soils (or sediments) from different coastal ecosystems influence the biogeochemistry of the tidal waters that inundate them? To better understand initial responses of coastal waters that flood coastal wetlands and uplands, we conducted short-term laboratory experiments where seawater was amended with sediments and soils collected across regional gradients of inundation exposure (i.e., frequently to rarely inundated) for 14 sites across the Mid-Atlantic, USA. Measured changes in dissolved oxygen and greenhouse gas concentrations were used to calculate gas consumption or production rates occurring during seawater exposure to terrestrial materials. We also measured soil and water physical and chemical properties to explore potential drivers. We observed higher oxygen consumption rates for seawater incubated with soils/sediments from frequently inundated locations and higher carbon dioxide production for seawater incubated with soils from rarely inundated transect locations. Incubations with soil from rarely inundated sites produced the highest global warming potential, primarily driven by carbon dioxide and secondarily by nitrous oxide. We also found environmental drivers of gas rates varied notably between transect locations. Our findings indicate that seawater responses to soil and sediment inputs across coastal terrestrial-aquatic interfaces exhibit some consistent patterns and high intra- and inter-site variability, suggesting potential biogeochemical feedback loops as inundation regimes shift inland.

coastal inundation↗

Electrochemical Nutrient Recovery for the Food–Energy–Water Nexus at Municipal Wastewater Facilities: Multivariate Analyses of Seasonal Sampling and Reactor Performance

Digester-equipped municipal wastewater facilities generate recycle streams with high nutrient loads that increase energy consumption and can cause environmental pollution. The reduction of these loads through electrochemical nutrient recovery (ENR) could enhance the food–energy–water nexus by producing fertilizer (struvite). This study investigated the recovery process through a 1 year sampling of recycle streams and the implementation of nutrient recovery. Time series analyses showed that P (as orthophosphate) concentration was time-variant in digester effluent streams, while N (as ammonia) concentration was time-variant in only the aerobic system. Furthermore, these two nutrient concentrations did not correlate in any of the recycle streams. Subsequent multivariate screening analyses identified anode type, NH 4 + concentration, cathodic potential, P concentration, and temperature as most significant for ENR. Finally, the optimum conditions of cathodic potential, anode area-to-volume ratio, and temperature applied to a real recycle stream resulted in 95% P recovery with 0.03 kWh/kg P. This energy consumption is significantly lower than process energy for conventional P fertilizers (1.1 kWh/kg P) and chemical recovery processes at scale (1.7–12.9 kWh/kg P). Overall, this study recommended specific process controls for nutrient recovery, expanded the variables evaluated for ENR, and demonstrated the ability to significantly impact energy demand associated with P-based fertilizers.

36 MATERIALS SCIENCE↗

Net Zero Energy Model for Wastewater Treatment Plants

The primary objective of this study is to achieve net-zero energy (NZE) wastewater treatment plants (WWTPs) by utilizing energy efficiency opportunities (EEO), combined heat and power (CHP) systems, and other renewable energy (RE) sources, e.g., solar, water, and wind powers. Herein, this study discusses an innovative energy solution for WWTPs in the United States, and one of the WWTPs with a flow capacity of 1.5 million gallons per day (MGD) was selected as a case study. An optimization tool, Hybrid Optimization of Multiple Energy Resources (HOMER) software, is used in this study to find the best energy system configuration to run the system. An energy audit for one WWTP was conducted in early 2020 and the report is used to do this study. The proposed EEOs were able to reduce WWTP energy consumption by about 11%. The excess anaerobic digester gas was utilized in a CHP system to cover about 42% of the facility’s consumption. Also, 3% of the utility energy consumption can be claimed by microturbines in the aeration tanks. Another two renewable energy systems, solar photovoltaic (PV) with 29% and water turbines with 15%, contribute to covering 100% of the WWTP energy consumption and achieving an NZE WWTP.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Controlled-Environment Agriculture and the Geography of Food, Energy and Water Resilience in the United States

USDA guidelines call for an increase in fruit and vegetable consumption in U.S. households to promote healthier diets. Access to fresh fruits and vegetables are especially lacking in food deserts and food swamps (characterized by a prevalence of food that is highly processed and lacking in nutritional value). Adoption of the recommended healthy diet, which more than doubles the consumption of fruits and vegetables, would have a wide variety of health benefits and would reduce the land footprint of U.S diets. However, adopting a healthy diet would increase phosphate and nitrogen impacts associated with fertilizers and pesticides and would significantly increase freshwater consumption and energy use because of the resource intensity of field cultivation of fruits and vegetables. The majority of these crops are grown in just a few states, including California and Arizona, which are increasingly impacted by climate change. In addition, rural communities are rapidly becoming food deserts, while food produced in these areas is transported long distances to market. In recent years, highly intensified controlled environment (CE) agricultural systems, (i.e., vertical farming) have been developed to provide fresh food closer to consumers. Fruits and vegetables, many of which are amenable to CE culture, occupy a uniquely impactful segment of the food supply-chain, including their value in improving nutrition for vulnerable communities. The objective of this work is to elucidate the location dependency of the energy and water impacts of adoption of distributed CE farming for an important portion of the food system.

controlled environment agriculture↗

Consequence Analysis of Residual Water in a Storage Canister - 20484

Recent observations from projects sponsored under the DOE-Nuclear Energy Spent Fuel and Waste Disposition campaign show that residual free water, well above the 0.4 gm-moles that correspond to a 3 torr rebound pressure after a 30-minute hold following prototypic drying, may remain within SNF canisters used for long-term dry storage. Specifically, experimental observations in an Integrated Research Project showed subzero temperatures and a local pocket of frozen water in a mockup fuel assembly subjected to an industry practiced drying process. In gas sampling and analysis from the High Burnup (HBU) Demonstration project, using a fully loaded and dried SNF canister, indicated presence of 100 g of residual water had remained in the canister. The effects of residual water in terms of potential adverse impacts on the condition of the SNF and the canister internals during long-term dry storage has been rigorously evaluated to address inadvertent residual water contents. The impact of residual water on the fuel and canister internals, with a focus on the oxidation of the cladding and of postulated exposed (breached-clad) fuel, were evaluated using an integrated set of time-dependent environmental conditions with semi-empirical materials oxidation models. An 'integration model,' with coupled sub-models, developed and previously used by the Center for Nuclear Waste Regulatory Analysis (CNWRA), was applied and expanded with improved sub-models for water radiolysis, and for cladding and fuel oxidations. Cladding oxidation models for various alloys were developed using the rate constants for various cladding alloys in the dry storage temperature range. A burnup-dependent fuel oxidation model was developed; it accounted for inhibition effect of fission products on fuel oxidation rates. The potential for extension of the initial breach flaw (1 mm hole) was evaluated by two separate mechanics criteria. In the first case, a critical cladding strain criterion was used. In the second case, a critical stress intensity was used to evaluate stability of a planar axial flaw postulate. A failure condition exists when a sufficient amount of fuel oxidation (at the postulated breached-clad location) causes fuel pellet swelling to load the cladding to meet a mechanics criterion for flaw extension. The integration model's results provide the following insights. The radiolysis-generated oxygen is consumed with a partitioning between the cladding and the fuel. The extent of cladding oxidation is no more than 2 μm additional consumption of the cladding metal even with 10 moles of residual water, indicating that changes in cladding conditions due to water are expected to be negligible. The conditions for cladding failure (breach opening size extension) directly correlates with the extent of fuel oxidation. Fuel oxidation significant to extend the breach could occur even with 5.5 moles of residual water. The results indicate that fuel oxidation vis-a-vis cladding oxidation is more likely under a higher radiation field, i.e., when radiolytic decomposition of the residual water occurs in few years compared to several decades, and that the conditions to cause failure are increased with fuel and cladding temperatures approaching the peak storage temperature limit of 400 deg. C. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Flume and single-pass washing systems for fresh-cut produce processing: Disinfection by-products evaluation

Free chlorine is widely used in fresh-cut produce washing to minimize microbial cross-contamination, but its application can also lead to the formation of harmful disinfection byproducts (DBPs). This study compared DBPs in process water and washed produce during commercial operation. Samples of shredded lettuce and diced cabbages washed in chlorinated water in the traditional double-flume wash and novel immersion-free single-pass wash systems were collected at multiple time points and locations from the processing lines. A suite of 33 conventional and emerging DBPs, including 4 trihalomethanes (THMs), 9 haloacetic acids (HAAs), 9 nitrogenous DBPs (N-DBPs), and 11 carbonaceous DBPs (C-DBPs), were investigated. Overall, N-DBPs and HAAs dominated the concentration of detected DBPs. Wash water in the flumes contained 7–111 folds higher DBP levels compared to that in the single-pass system, with the abundance of DBPs following the order of N-DBPs > HAAs > C-DBPs > THMs. DBPs were detected on washed produce, presenting primarily in the forms of N-DBPs and HAAs followed by C-DBPs and THMs. While higher levels of DBPs were detected in flume-washed produce, the final potable water rinse significantly reduced the DBP concentration in these products. The concentrations of THMs and HAAs on these washed products were used to estimate potential exposure via consumption of fresh-cut produce and the levels were below the daily allowable exposure for drinking water standard established by the U.S. Environmental Protection Agency. The detected high concentration and potential toxicity of N-DBPs indicate the need for further research. Here, the findings of this study advance the understanding of the formation and removal of DBPs during wash processes, and identify additional research opportunities for further reduction in DBPs and food safety improvement.

59 BASIC BIOLOGICAL SCIENCES↗