Synthesis of Butyl-Exchanged Polyoxymethylene Ethers as Renewable Diesel Blendstocks with Improved Fuel Properties

Methyl-terminated polyoxymethylene ethers (MM-POMEs), having the formula CH3O–(CH2O)n–CH3 (n = 3–5), are a high-cetane, low-sooting group of oxygenates that have recently attracted attention as potential diesel blendstocks. Despite these attractive fuel properties, MM-POMEs have shortcomings due to their low energy density and high water solubility. Guided by a computational fuel property assessment for POMEs with longer end-groups, the most promising improvements in the desired compression ignition fuel properties were observed for butyl-terminated POMEs. Here, an acid-catalyzed transacetalization reaction was developed to exchange the methyl end-groups of MM-POMEs (n = 3–6) with butyl end-groups. The reaction utilizes an ion-exchange resin as the acid catalyst at mild reaction conditions of 60 °C and atmospheric pressure. Approximately 100 mL of butyl-exchanged POMEs in the diesel boiling range were produced, enabling laboratory-scale fuel property testing. The butyl-terminated POME mixture possesses the advantaged fuel properties of the parent MM-POMEs (low-soot, high-cetane) while exhibiting improved energy density (lower heating value (LHV) of 30 MJ/kg) and substantially reduced water solubility (7.3 g/L) compared to the parent MM-POME mixture (LHV of 19 MJ/kg , water solubility of 258 g/L).

09 BIOMASS FUELS↗

The effect of tropospheric fluctuations on the accuracy of water vapor radiometry

Line-of-sight path delay calibration accuracies of 1 mm are needed to improve both angular and Doppler tracking capabilities. Fluctuations in the refractivity of tropospheric water vapor limit the present accuracies to about 1 nrad for the angular position and to a delay rate of 3x10(exp -13) sec/sec over a 100-sec time interval for Doppler tracking. This article describes progress in evaluating the limitations of the technique of water vapor radiometry at the 1-mm level. The two effects evaluated here are: (1) errors arising from tip-curve calibration of WVR's in the presence of tropospheric fluctuations and (2) errors due to the use of nonzero beamwidths for water vapor radiometer (WVR) horns. The error caused by tropospheric water vapor fluctuations during instrument calibration from a single tip curve is 0.26 percent in the estimated gain for a tip-curve duration of several minutes or less. This gain error causes a 3-mm bias and a 1-mm scale factor error in the estimated path delay at a 10-deg elevation per 1 g/cm(sup 2) of zenith water vapor column density present in the troposphere during the astrometric observation. The error caused by WVR beam averaging of tropospheric fluctuations is 3 mm at a 10-deg elevation per 1 g/cm(sup 2) of zenith water vapor (and is proportionally higher for higher water vapor content) for current WVR beamwidths (full width at half maximum of approximately 6 deg). This is a stochastic error (which cannot be calibrated) and which can be reduced to about half of its instantaneous value by time averaging the radio signal over several minutes. The results presented here suggest two improvements to WVR design: first, the gain of the instruments should be stabilized to 4 parts in 10(exp 4) over a calibration period lasting 5 hours, and second, the WVR antenna beamwidth should be reduced to about 0.2 deg. This will reduce the error induced by water vapor fluctuations in the estimated path delays to less than 1 mm for the elevation range from zenith to 6 deg for most observation weather conditions.

Wilcox, J. Z.↗

Spatial patterns in occupancy and density of larval lampreys in freshwater habitats restored to a Stage 0 condition

Abstract We examined occupancy and density of larval lampreys ( Entosphenus tridentatus and Lampetra spp.) in two rivers in Oregon (USA) restored to a Stage 0 condition 1–5 years prior, using a multiscale occupancy model and a zero‐inflated Poisson mixture model. We sampled lampreys using backpack electrofishing in randomly distributed, paired, 1‐m 2 quadrats and recorded environmental data. Probabilities of occupancy and density were higher when water velocity was low, the substrate was noncompacted, and sediment was dominated by fines (<4 mm). At mean water depth (0.34 m) and velocity (0.09 m/s), estimated densities in occupied quadrats were 4.8 lampreys/m 2 (95%: 3.4–6.9) when the substrate was compacted, and fines were not dominant, and 21.1 lampreys/m 2 (95%: 17.7–25.3) when the substrate was noncompacted and fines were dominant. Probabilities of detecting occupancy in a 1‐m 2 quadrat sampled by backpack electrofishing were 0.76 (95%: 0.64–0.87) when captured after visual observation and 0.80 (95%: 0.71–0.88) with blind sweeps (i.e., constantly moving the net regardless of observation). The probability of capturing a single lamprey in a quadrat sampled by blind sweeps was 0.32 (95%: 0.27–0.37). Sampling in paired 1‐m 2 quadrats facilitated concurrent examination of patterns in occupancy and density while accounting for capture probability, which could aid temporal monitoring of restored habitats. To the best of our knowledge, this is the first study to document occupancy and estimate densities of larval lampreys in habitats that underwent valley floor restoration to Stage 0. We observed both lamprey genera within 5 years of restoration. Aquatic restoration that increases low‐velocity, noncompacted, fine sediment habitats could benefit lampreys.

Harris, Julianne E.↗

Determination of Water Content in Bio-Oils by Volumetric Karl Fischer Titration: Laboratory Analytical Procedure (LAP)

The water content of bio-oils is a key metric for several reasons. Water is typically the most concentrated single component of fast pyrolysis oils, though this will be much lower in catalytic fast pyrolysis and upgraded products. Reduced water content is preferable in bio-oil as water can contribute to phase separation, corrosivity, and instability. Additionally, lower water is beneficial for physical properties such as energy density. The percentage of water can also be used to correct the calculation for organic oxygen when determining total oxygen content of bio-oils via combustion-based ultimate analysis. The procedure described here is specifically written for the analysis of bio-oils, and is based on ASTM E203, Standard Test Method for Water Using Volumetric Karl Fischer Titration. This standard test method is specified for measuring the mass % water in pyrolysis liquid biofuels in ASTM D7544, Standard Specification for Pyrolysis Liquid Biofuel. Although the standard method is prescribed for the analysis of pyrolysis liquids for use in industrial and commercial burners, the method is not specifically written for this product. The method described with this Laboratory Analytical Procedure (LAP) provides specific guidance for the analysis of bio-oils. Both organic and aqueous phases can be measured with this technique.

09 BIOMASS FUELS↗

Effect of Biochar and Biochar Particle Size on Plant-Available Water of Sand, Silt Loam, and Clay Soil

Biochar is being used as a soil amendment to improve soil hydraulic properties. It has been reported that biochar increases plant-available water, particularly in coarse-textured soils; however, effects on fine-textured soils are less pronounced. Here, we quantified the effects of biochar particle size on plant-available water in sand, silt loam, and clay soils. We amended these soils with a hydrophilic biochar, and packed soil-biochar mixtures into columns of 5.35-cm diameter and 3.0-cm height. Biochar was produced by gasification of woody forest residues. We applied the biochar at two different rates (0.5\% and 2\% by weight of C) and with four different biochar particle-size fractions ($<$4.75, $<$2.0, $<$1.0 and $<$0.5 mm). Our results show that biochar amendments increased the plant-available water (when expressed gravimetrically) of all three soils, particularly at the highest biochar application rate. Although the absolute increase in plant-available water was largest for the silt loam soil, the relative increase of plant-available water was greater for the sand than for the silt loam and clay. When expressed in volumetric terms, however, the effects on water retention were less pronounced: the sand showed a small increase in plant-available water with biochar amendment, and no change was observed with the silt loam and clay. Particle size of biochar had little effect on plant-available water (when expressed in gravimetric terms) in the three soils, but silt loam and clay showed increased plant-available water (when expressed in volumetric terms) with decreasing biochar particle size, while no effect was observed for the sand. While our findings corroborate many of the previously reported effects of biochar on soil-water retention, we show that the effects and their magnitude depend on whether the results are reported in terms of gravimetric or volumetric water contents. Because bulk density tends to decrease with increasing biochar application, so will the volumetric water content, and thus the magnitude of the effect on plant-available water will be smaller when expressed in volumetric water content.

hydraulic properties, water holding capacity, soil↗

Investigation of ventilation-coupled high energy density sensible thermal energy storage

Low-cost energy storage will play an important role in supporting the decarbonization of the energy sector. Here, a novel approach to thermal energy storage for buildings is proposed, in which a tank of antifreeze liquid can be used to heat outdoor air in mechanical ventilation systems. If heated to a high enough temperature, the fluid can potentially undergo temperature swings of nearly 100°C during discharge in cold climates. Because the energy density of sensible storage systems scales proportionally to the system temperature change, this concept has the potential to offer higher energy densities than other liquid-based sensible storage devices used in building applications. A one-dimensional numerical model of the storage system was developed and experimentally validated using 30 wt% (wt%) potassium acetate as an aqueous antifreeze solution. Using a commercial hot water tank, energy densities of 47.0 kW-hour per cubic meter (kWh/m 3 ) were demonstrated in a laboratory setting. Material energy densities of approximately 74.7 (kWh/m 3 ) were measured. Design improvements may boost this energy storage density even further. Because of the system's relative simplicity, ventilation-coupled sensible storage has the potential to be an easily deployable, low-cost energy storage solution for building systems.

25 ENERGY STORAGE↗

Diesel fuel properties of renewable polyoxymethylene ethers with structural diversity

Polyoxymethylene ethers (POMEs) are a class of low-soot and high-cetane oxygenate oligomers of structure RO-(CH 2 O-) $n$ -R, with different chain lengths ($n$) and end-groups (R) that determine their diesel-like fuel properties. Commercial POMEs with methyl end-groups (MM-POME 3-6 ) exhibit undesirably low energy density and high-water solubility. A previous computational assessment indicated that the lower heating value (LHV) and water solubility for MM-POME 3-6 both improve upon end-group exchange with larger butyl, $iso$-butyl and $iso$-pentyl end-groups. Here, we expanded upon our initial trans-acetalization reaction that employed 1-butanol to install butyl end-groups to also include branched, higher carbon-number end-groups using $iso$-butanol and fusel oil as reagents. Additionally, these new products are termed $i$B*POME 1-6 , and FOil*POME 1-5 , respectively, and collectively referred to as R*POMEs. They possess the advantaged properties of the parent MM-POME 3-6 while exhibiting higher LHV (31 MJ kg -1 and 28 MJ kg -1 for $i$B*POME 1-6 , and FOil*POME 1-5 , respectively) and much reduced water solubility (2.7 g L -1 and 1 g L -1 for $i$B*POME 1-6 , and FOil*POME 1-5 , respectively). Additional fuel property analyses were performed using 20 vol% blends of the R*POMEs with a base diesel fuel. Overall, the greater energy density and decreased water solubility of the R*POMEs, as well as their synergistic blending with diesel at moderate blend levels, provide the greatest benefits to consumers and position this group of products as an environmentally friendlier blendstock alternative to the commercially available MM-POME 3-6 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ir(hkl) Surface Electrochemistry in a Nonadsorbing Acidic Medium

The fundamental properties of electrochemical materials depend on the multiple and often complex interactions between electrode surface sites and electrolyte species at the electrochemical interface. Despite Iridium use in electrolyzer systems, much of its surface electrochemistry remains underexplored. This study investigates the surface electrochemistry of Ir(111), Ir(100), and Ir(110) surfaces in acidic media. Using cyclic voltammetry and CO charge displacement experiments, we establish the charge states and adsorbate coverages as a function of the electrode potential, revealing the presence of hydrogen and hydroxyl co-adsorption at low potentials on (111), and almost no coverage of H ad on (110) facet. In situ Shell Isolated Nanoparticle Enhanced Raman Spectroscopy experiments provide direct evidence of the formation of key adsorbate species, such as hydrogen, hydroxyl, and oxygen, but most importantly, their interactions with interfacial water, confirmed by Density Functional Theory calculations. Our findings highlight the role of co-adsorption and interspecies interactions, with microkinetic adsorption voltammetry simulations corroborating the influence of lateral interactions on adsorption dynamics, particularly for Ir(100) where the OHad formation occurs as a sharp adsorption/desorption current. Our results underscores the importance of interfacial water and hydrogen bonding networks in shaping the electrochemical behavior on Ir surfaces, refining our baseline understanding of the Ir surface electrochemistry necessary for the development of advanced Ir-based electrochemical materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temporal relationships between spectral response and agronomic variables of a corn canopy

Attention is given to an experiment in which spectral radiance data collected in three spectral regions are related to corn canopy variables. The study extends the work of Tucker et al. (1979) in that more detailed measurements of corn canopy variables were made using quantitative techniques. Wet and dry green leaf biomass is considered along with the green leaf area index, chlorotic leaf biomass, chlorotic leaf area, and leaf water content. In addition, spectral data were collected with a hand-held radiometer having Landsat-D Thematic Mapper (TM) bands TM3 (0.63-0.69 micrometers), TM4 (0.76-0.90 micrometers), and TM5 (1.55-1.75 micrometers). TM3, TM4, and TM5 seem to be well situated spectrally for making remotely sensed measurements related to chlorophyll concentration, leaf density, and leaf water content.

Kimes, D. S.↗

Electrostatic limits on charge selectivity in ultrahigh charge density polymer membranes

Ion-exchange membranes (IEMs) with ultrahigh charge densities offer the promise of enhanced ion transport for electrochemical technologies, yet the fundamental limits of this membrane design strategy are not yet understood. In this work, we present a systematic study of bis(1-vinyl-3-imidazolium) cross-linked polymer membranes with fixed charge contents ranging from 6 to 9 mol/L[dry polymer], synthesized to isolate the effects of charge density at constant membrane water content. While ionic conductivity increases monotonically with increasing charge density, a sharp decline in charge selectivity is observed for the most densely charged membranes, defying conventional expectations. Structural, thermal, and mechanical analyses reveal a critical onset of network disruption and anomalous ion partitioning behavior in these densely charged membranes. With proper consideration of cross-linker geometry, these results are interpreted using Manning's counter-ion condensation theory, which suggests that closely packed charged cross-linkers amplify inter-chain electrostatic interactions and trigger excess counter-ion condensation. Our findings suggest that, beyond a threshold spacing between fixed charges, increased functionalization may harm rather than help charge selectivity of IEMs.

36 MATERIALS SCIENCE↗

Study of self-interaction errors in density functional predictions of dipole polarizabilities and ionization energies of water clusters using Perdew-Zunger and locally scaled self-interaction corrected methods

Here, we studied the effects of self-interaction error (SIE) on the static dipole polarizabilities of water clusters modelled with three increasingly sophisticated, non-empirical density functional approximations (DFAs), viz. the local spin density approximation (LDA), the Perdew-Burke-Ernzherof (PBE) generalized-gradient approximation (GGA), and the strongly constrained and appropriately normed (SCAN) meta-GGA, using the Perdew-Zunger self-interaction-correction (PZ-SIC) energy functional in the Fermi-Lowdin orbital SIC (FLO-SIC) framework. Our results show that while all three DFAs overestimate the cluster polarizabilities, the description systematically improves from LDA to PBE to SCAN. The self-correlation free SCAN predicts polarizabilities quite accurately with a mean absolute error (MAE) of 0.58 Bohr 3 with respect to coupled cluster singles and doubles (CCSD) values. Removing SIE using PZ-SIC correctly reduces the DFA polarizabilities, but over-corrects, resulting in underestimated polarizabilities in SIC-LDA, -PBE, and -SCAN. Finally, we applied a recently proposed local-scaling SIC (LSIC) method using a quasi self-consistent scheme and using the kinetic energy density ratio as an iso-orbital indicator. The results show that the LSIC polarizabilities are in excellent agreement with mean absolute error of 0.08 Bohr 3 for LSIC-LDA and 0.06 Bohr 3 for LSIC-PBE with most recent CCSD polarizabilities. Likewise, the ionization energy estimates as an absolute of highest occupied energy eigenvalue predicted by LSIC are also in excellent agreement with CCSD(T) ionization energies with MAE of 0.4 eV for LSIC-LDA and 0.04 eV for LSIC-PBE. The LSIC-LDA predictions of ionization energies are comparable to the reported GW ionization energies while the LSIC-PBE ionization energies are more accurate than reported GW results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

BOREAS HYD-3 Snow Measurements

The Boreal Ecosystem-Atmosphere Study (BOREAS) Hydrology (HYD)-3 team collected several data sets related to the hydrology of forested areas. This data set contains measurements of snow depth, snow density in three cm intervals, an integrated snow pack density and snow water equivalent (SWE), and snow pack physical properties from snow pit evaluation taken in 1994 and 1996. The data were collected from several sites in both the southern study area (SSA) and the northern study area (NSA). A variety of standard tools were used to measure the snow pack properties, including a meter stick (snow depth), a 100 cc snow density cutter, a dial stem thermometer, and the Canadian snow sampler as used by HYD-4 to obtain a snow pack-integrated measure of SWE. This study was undertaken to predict spatial distributions of snow properties important to the hydrology, remote sensing signatures, and the transmissivity of gases through the snow. The data are available in tabular ASCII files. The snow measurement data are available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC). The data files are available on a CD-ROM (see document number 20010000884).

Hardy, Janet P.↗

Accessing Icy Worlds using Lattice Confinement Fusion (LCF) Fast Fission

NASA proposed the Ocean Worlds Exploration Program to search for extraterrestrial life. The challenge is that up to 40 kilometer-thick ice must first be broken through to reach sub-surface oceans. These icy ocean worlds include Ceres, Europa, Enceladus, and Pluto. Each world may have a liquid water ocean beneath their ice crust. These oceans are likely heated by the parent planet’s tidal forces, or in the case of Pluto or Ceres, by residual radioactive decay. A robotic probe exploring the oceans beneath must either melt or bore through the ice crust first. Consequently, the proposed probe needs to contend with hydrostatic ice pressure, ice phase and density changes, then water pressure. Such a mission requires a small, but robust and long lived, electrical energy and heat source. Instead, we propose a novel, compact, scalable nuclear energy source using neither highly enriched uranium (HEU) nor 238Pu similar to the hybrid fusion-fission generator described by Forsley and Mosier-Boss. This nuclear energy source uses Lattice Confinement Fusion (LCF) neutrons to fast-fission thorium or depleted uranium where neither 232Th nor 238U isotopes are fissile

Theresa L Benyo↗

Using a Multiwavelength Suite of Microwave Instruments to Investigate the Microphysical Structure of Deep Convective Cores

Due to the large natural variability of its microphysical properties, the characterization of solid precipitation is a longstanding problem. Since in situ observations are unavailable in severe convective systems, innovative remote sensing retrievals are needed to extend our understanding of such systems. This study presents a novel technique able to retrieve the density, mass, and effective diameter of graupel and hail in severe convection through the combination of airborne microwave remote sensing instruments. The retrieval is applied to measure solid precipitation properties within two convective cells observed on 2324 May 2014 over North Carolina during the IPHEx campaign by the NASA ER-2 instrument suite. Between 30 and 40 degrees of freedom of signal are associated with the measurements, which is insufficient to provide full microphysics profiling. The measurements have the largest impact on the retrieval of ice particle sizes, followed by ice water contents. Ice densities are mainly driven by a priori assumptions, though low relative errors in ice densities suggest that in extensive regions of the convective system, only particles with densities larger than 0.4 gcm3 are compatible with the observations. This is in agreement with reports of large hail on the ground and with hydrometeor classification derived from ground-based polarimetric radars observations. This work confirms that multiple scattering generated by large ice hydrometeors in deep convection is relevant for airborne radar systems already at Ku band. A fortiori, multiple scattering will play a pivotal role in such conditions also for Ku band spaceborne radars (e.g., the GPM Dual Precipitation Radar).

remote sensing retrievals↗

Quantifying the hydration structure of sodium and potassium ions: taking additional steps on Jacob's Ladder

The ability to reproduce the experimental structure of water around the sodium and potassium ions is a key test of the quality of interaction potentials due to the central importance of these ions in a wide range of important phenomena. In this study, we simulate the Na + and K + ions in bulk water using three density functional theory functionals: (1) the generalized gradient approximation (GGA) based dispersion corrected revised Perdew, Burke, and Ernzerhof functional (revPBE-D3) (2) the recently developed strongly constrained and appropriately normed (SCAN) functional (3) the random phase approximation (RPA) functional for potassium. We compare with experimental X-ray diffraction (XRD) and X-ray absorption fine structure (EXAFS) measurements to demonstrate that SCAN accurately reproduces key structural details of the hydration structure around the sodium and potassium cations, whereas revPBE-D3 fails to do so. However, we show that SCAN provides a worse description of pure water in comparison with revPBE-D3. RPA also shows an improvement for K + , but slow convergence prevents rigorous comparison. Finally, we analyse cluster energetics to show SCAN and RPA have smaller fluctuations of the mean error of ion–water cluster binding energies compared with revPBE-D3.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced space power PEM fuel cell systems

A model showing mass and heat transfer in proton exchange membrane (PEM) single cells is presented. For space applications, stack operation requiring combined water and thermal management is needed. Advanced hardware designs able to combine these two techniques are available. Test results are shown for membrane materials which can operate with sufficiently fast diffusive water transport to sustain current densities of 300 ma per square centimeter. Higher power density levels are predicted to require active water removal.

Vanderborgh, N. E.↗

AmeriFlux US-GL1 Stannard Rock

This is the AmeriFlux version of the carbon flux data for the site US-GL1 Stannard Rock. Site Description - Stannard Rock is located 39 km from the nearest shore (Keweenaw Peninsula) in Lake Superior, 44 miles NNE of Marquette, Michigan, and 24 miles ESE of Manitou Island. The site is located on the historic Stannard Rock Lighthouse, which was completed in 1882. Eddy covariance instrumentation was installed in 2008 by a network of scientists from both US and Canada, eventually to be called the Great Lakes Evaporation Network (GLEN). The intent of GLEN has been to provide observations of over-lake meteorology and evaporation, improve forecasting of Great Lakes water levels, and support a wide variety of stakeholders, including the National Weather Service (NWS), Environment and Climate Change Canada, National Oceanic and Atmospheric Administration, U.S. Coast Guard, recreational boaters and commercial shipping, emergency management officials, and the Great Lakes research community. The eddy covariance station along with other ancillary meteorological instrumentation is located at an approximate elevation of 39.2 meters above mean lake water level. Meteorological data from the lighthouse are sent to the National Data Buoy Center, where they can be viewed in real-time at http://www.ndbc.noaa.gov/station_page.php?station=stdm4 Uncorrected half-hour fluxes were computed directly on the logger using a 30-minute block averaging period as high-frequency data were not available. The half hour flux measurements downloaded from the datalogger were post-processed with the following filters and corrections. Latent and sensible heat and carbon dioxide fluxes were corrected with 2-D coordinate rotation. Although the primary objective of data collection at Stannard Rock was to quantify the evaporative flux, additional preliminary measurements of the carbon dioxide concentration and flux from the LI-7500 are also included in this dataset but it is advised to use the carbon data with caution. Carbon data reported in this dataset includes turbulent fluxes of CO2 with no storage correction (FC, µmol m-2 s-1) and CO2 density in mole fraction of wet air (CO2), which was originally output on the datalogger as average CO2 density (mg m-2 s-1) and converted into µmol mol-1 using air temperature and pressure in post-processing. Webb, Pearman, and Leuning terms were applied to account for density fluctuations for water vapor and CO2. Sonic path length, high-frequency attenuation and sensor separation were accounted for according to Horst and Massman, and the oxygen absorption correction for the KH2O hygrometer was also applied. Latent and sensible heat fluxes were assumed to be unrealistic above an absolute value of 1000 W m-2 and were removed. Both carbon flux (FC) and carbon dioxide mole fraction in wet air (CO2) and were assumed to be unrealistic above 1000 µmol m-2 s-1 and 1000 µmol mol-1 respectively. Spikes in latent and sensible heat and carbon fluxes and densities (often due to periods of precipitation) were identified by computing the mean and standard deviation over a moving, overlapping window of 336 half-hours (7 days), similar to Shao et al., and were removed when the flux was more than 1.5 standard deviations from the moving window’s mean. While Vickers and Mahrt use a threshold of 3.5 standard deviations from the mean, a conservative value of 1.5 was chosen due to the noisy nature of over-lake data at this particular site. This process was repeated twice for latent and sensible heat, and carbon dioxide fluxes and densities and therefore it is possible that some real, realistic data was filtered out in this process. No detrending was performed. As per AmeriFlux standards, no friction velocity (USTAR, m s-1) filtering was performed.

Spence, Chris↗