Search NASA⌕ Search

SEARCH · Search NASA

Results for “wire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Modifying Wire Array Z-pinch Ablation Structure and Implosion Dynamics Using Coiled Arrays

Coiled arrays, a cylindrical array in which each wire is formed into a helix, suppress the modulation of ablation at the fundamental wavelength. Outside the vicinity of the wire cores, ablation flow from coiled arrays is modulated at the coil wavelength and has a 2-stream structure in the r,{theta} plane. Within the vicinity of the helical wires, ablation is concentrated at positions with the greatest azimuthal displacement and plasma is axially transported from these positions such that the streams become aligned with sections of the coil furthest from the array axis. The GORGON MHD code accurately reproduces this observed ablation structure, which can be understood in terms of JxB forces that result from the interaction of the global magnetic field with a helical current path as well as additional current paths suggested by the simulations. With this ability to control where ablation streamers occur, large wavelength coils were constructed such that the breaks that form in the wires had sufficient axial separation to prevent perturbations in the implosion sheath from merging. This produces a new mode of implosion in which the global instability can be controlled and perturbations correlated between all wires in an array. For large wavelength 8-wire coiled arrays, this produced a dramatic increase in x-ray power, equalling that of a 32-wire straight array. These experiments were carried out on the MAGPIE generator (1 MA, 240 ns) at Imperial College, and the COBRA generator (1 MA, 100 ns) at Cornell University.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental study of star-like and small-diameter wire-array z-pinches on the 1-MA Zebra generator

Star-like wire arrays and small-diameter (1-3 mm in diameter) cylindrical loads were tested in the 1-MA Zebra generator. Mitigation of plasma inhomogeneity was observed in the implosions of star-like loads, which consisted of multiple nested, cylindrical arrays aligned azimuthally such that the wires appear as linear array 'rays' extending from the axis of symmetry. The implosion in these loads is directed along the 'rays' of the star and cascades from wire to wire to the center to form moving plasma columns with smooth leading edges. Despite the low azimuthal symmetry, a star-like wire array produces a stable x-ray pulse with a high peak power and a short duration of 8-12-ns. This can be linked to the stabilization of instabilities due to the multiple nesting. X-ray generation and implosion dynamics in wire arrays 1-16 mm in diameter were investigated to find a transition between the regime with prevailing kinetic energy and 'non-kinetic' plasma heating. Loads 3-8 mm in diameter generate the highest x-ray power at the Zebra generator. The fall of x-ray power in 1-2-mm loads can be linked to the lack of kinetic energy. Laser probing diagnostics show the formation of 'necks' on the pinch during the bubble-like implosion. The energy balance provides the evidence of the enhanced plasma heating in z-pinches. Features of the implosions in small-diameter wire-arrays can help to identify the mechanisms of energy dissipation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characteristics of implosion and radiation for aluminum planar wire array z-pinch at 1.5 MA

Planar wire arrays Z pinches were carried out on Qiangguang generator (1.5 MA, 100 ns). Loads with varied row widths (6-24 mm) and wire numbers (10-34) were employed in the experiments. The implosion dynamics of planar wire arrays has been studied. Meanwhile, the changes of the implosion time, radiation yield and power with array mass, inter-wire gap, and array width were investigated. The images of a soft X-ray camera exhibit that the trailing mass, precursor column, and R-T instability exist during the implosion phase, and when m = 0 maybe accompanied with m = 1, instability will rapidly develop after stagnation. The implosion trajectories show that loads will implode by the snowplow mode and about 50% of total initial array mass will participate in the final implosion. The maximum total X-ray energy is 22 kJ with a power of 630 GW, while the maximum K-shell yield is 3.9 kJ with a power of 158 GW. Experiments with different planar wire arrays show that the value of m{sub P}D{sub 0}{sup 2} (the product of line mass and squared width) is the critical factor which affects the implosion time and the X-ray products of the wire arrays. The optimum value of m{sub P}D{sub 0}{sup 2} should be in the range of 200-400 {mu}gcm and the inter-wire gap should be less than 1 mm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ablation dynamics in coiled wire-array Z-pinches

Experiments to study the ablation dynamics of coiled wire arrays were performed on the MAGPIE generator (1 MA, 240 ns) at Imperial College, and on the COBRA generator at Cornell University's Laboratory of Plasma Studies (1 MA, 100 ns). The MAGPIE generator was used to drive coiled wires in an inverse array configuration to study the distribution of ablated plasma. Using interferometry to study the plasma distribution during the ablation phase, absolute quantitative measurements of electron line density demonstrated very high density contrasts between coiled ablation streams and inter-stream regions many millimetres from the wire. The measured density contrasts for a coiled array were many times greater than that observed for a conventional array with straight wires, indicating that a much greater axial modulation of the ablated plasma may be responsible for the unique implosion dynamics of coiled arrays. Experiments on the COBRA generator were used to study the complex redirection of plasma around a coiled wire that gives rise to the ablation structure exhibited by coiled arrays. Observations of this complex 3D plasma structure were used to validate the current model of coiled array ablation dynamics [Hall et al., Phys. Rev. Lett. 100, 065003 (2008)], demonstrating irrefutably that plasma flow from the wires behaves as predicted. Coiled wires were observed to ablate and implode in the same manner on both machines, indicating that current rise time should not be an issue for the scaling of coiled arrays to larger machines with fast current rise times.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Growth and characterization of horizontal GaN wires on silicon

We report the growth of in-plane GaN wires on silicon by metalorganic chemical vapor deposition. Triangular-shaped GaN microwires with semi-polar sidewalls are observed to grow on top of a GaN/Si template patterned with nano-porous SiO{sub 2}. With a length-to-thickness ratio ∼200, the GaN wires are well aligned along the three equivalent 〈 112{sup ¯}0 〉 directions. Micro-Raman measurements indicate negligible stress and a low defect density inside the wires. Stacking faults were found to be the only defect type in the GaN wire by cross-sectional transmission electron microscopy. The GaN wires exhibited high conductivity, and the resistivity was 20–30 mΩ cm, regardless of the wire thickness. With proper heterostructure and doping design, these highly aligned GaN wires are promising for photonic and electronic applications monolithically integrated on silicon.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of composition and substrate miscut on the evolution of (105)-terminated in-plane Si{sub 1−x}Ge{sub x} quantum wires on Si(001)

Isolated in-plane wires on Si(001) are promising nanostructures for quantum transport applications. They can be fabricated in a catalyst-free process by thermal annealing of self-organized Si{sub 1−x}Ge{sub x} hut clusters. Here, we report on the influence of composition and small substrate miscuts on the unilateral wire growth during annealing at 570 °C. The addition of up to 20% of Si mainly affects the growth kinetics in the presence of energetically favorable sinks for diffusing Ge atoms, but does not significantly change the wire base width. For the investigated substrate miscuts of <0.12°, we find geometry-induced wire tapering, but no strong influence on the wire lengths. Miscuts <0.02° lead to almost perfect quantum wires terminated by virtually step-free (105) and (001) facets over lengths of several 100 nm. Generally, the investigated Si{sub 1−x}Ge{sub x} wires are metastable: Annealing at ≥600 °C under otherwise identical conditions leads to the well-known coexistence of Si{sub 1−x}Ge{sub x} pyramids and domes.

36 MATERIALS SCIENCE↗

Transport properties of partially equilibrated quantum wires.

We study the effect of thermal equilibration on the transport properties of a weakly interacting one-dimensional electron system. Although equilibration is severely suppressed due to phase-space restrictions and conservation laws, it can lead to intriguing signatures in partially equilibrated quantum wires. We consider an ideal homogeneous quantum wire. At finite temperature we find a correction to the quantized conductance, which for a short wire scales with its length, but saturates in the limit of an infinitely long wire. We also discuss thermoelectric properties of long quantum wires. We show that the uniform quantum wire is a perfect thermoelectric refrigerator, approaching Carnot efficiency with increasing wire length.

30 DIRECT ENERGY CONVERSION↗

ac susceptibility studies of intra- and intergrain properties of high-$J_c$ Bi-2212 wires

Bi 2 Sr 2 CaCu 2 O x (Bi-2212) is the only high-$T_c$ superconductor (HTS) available as a multifilamentary round wire with multiple architectures and it is a very promising conductor for the realization of high-field applications. Despite their relatively simple wire fabrication by the powder-in-tube technique, Bi-2212 wires require a tightly controlled overpressure heat treatment (HT) with a multi-parameter time-temperature schedule to achieve high critical current density, $J_c$. Further, the variation of these HT parameters, changes in the wire design, wire diameter and powder quality can lead to variations in both the microstructure and the superconducting performance. Particularly noticeable are variations in $J_c$ performance and degree of filament bridging. In this work, we focus on the use of different magnetic characterization techniques to estimate the bridging level and assess the balance of INTER-grain and intra-grain superconducting properties including the irreversibility field ($H_{\text{irr}}$) and the pinning energy ($U_0$) in differently processed wires. Regardless of the actual bridging level, we find that the supercurrent flows at the filament bundle level, not just at the individual filament level. Moreover, using AC susceptibility we identify two distinct supercurrent contributions, one related to the intra-grain and one to the INTER-grain properties, whose irreversibility fields are different but without large sample-to-sample variation. Moreover, an additional component of intra-grain pinning mechanism becomes effective at low temperatures with positive effects also on the INTER-grain performance. The work clearly shows that detailed magnetic characterizations can become valuable tools to investigate the performance of differently processed Bi-2212 wires, correlating their microstructure and overall transport $J_c$, to obtain a deeper understanding of the causes of performance variation and paths to achieve further improvement.

2212↗

Finite-element analysis of transverse compressive and thermal loads on Nb 3 Sn wires with voids

High-field superconducting magnets play a very important role in many large-scale physics experiments, particularly particle colliders and fusion confinement devices such as Large Hadron Collider (LHC) and International Thermonuclear Experimental Reactor (ITER). The two most common superconductors used in these applications are NbTi and Nb 3 Sn. Nb 3 Sn wires are favored because of their significantly higher J c (critical current density) for higher field applications. The main disadvantage of Nb 3 Sn is that the superconducting performance of the wire is highly strain sensitive and it is very brittle. This strain sensitivity is strongly influenced by two factors: plasticity and cracked filaments. Cracks are induced by large stress concentrators that can be traced to the presence of voids in the wire. We develop detailed 2-D and 3-D finite-element models containing wire filaments and different possible distributions of voids in a bronze-route Nb 3 Sn wire. We apply compressive transverse loads for various cases of void distributions to simulate the stress and strain response of a Nb 3 Sn wire under the Lorentz force. Furthermore, this paper improves our understanding of the effect voids have on the Nb 3 Sn wire's mechanical properties, and in so, the connection between the distribution of voids and performance degradation such as the correlation between irreversible strain limit and the void-induced local stress concentrations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Voltage-Current Behavior of a Superconducting STAR ® Wire in a 6-Around-1 Cable Configuration

A 6-around-1 transposed cable using superconducting STAR® wires can be useful for future circular collider applications. We made three cable samples using single STAR® wires with a diameter of 1.3 mm. The first two samples, made with a cabling machine, used STAR® wires consisting of a 0.7 mm diameter Nb-Ti core. The third cable sample was manually wound and used a STAR® wire made with a 0.81 mm diameter Cu core. The first sample showed severe degradation after the cable was bent to a 75 mm radius. The current-carrying capability of the innermost and outermost REBCO tapes in the STAR® wire degraded by 42% to 98% and the middle REBCO tapes remained intact. This was also the case for the second and straight cable sample. After fabrication of the third cable sample, we observed only about 5% reduction in the current along the wire, measured at different locations inside the terminations. Finally, the results indicate that the differences in architecture or fabrication of the STAR® wires could have caused differences in critical current retention after cabling.

6-around-1 cable↗

Anisotropic Thermal Response of Packed Copper Wire

The apparent thermal conductivity of packed copper wire test specimens was measured parallel and perpendicular to the axis of the wire using laser flash, transient plane source, and transmittance test methods. Approximately 50% wire packing efficiency was produced in the specimens using either 670- or 925-μm-diameter copper wires that both had an insulation coating thickness of 37 μm. The interstices were filled with a conventional varnish material and also contained some remnant porosity. The apparent thermal conductivity perpendicular to the wire axis was about 0.5–1 W/mK, whereas it was over 200 W/mK in the parallel direction. The Kanzaki model and an finite element analysis (FEA) model were found to reasonably predict the apparent thermal conductivity perpendicular to the wires but thermal conductivity percolation from nonideal wire-packing may result in their underestimation of it.

30 DIRECT ENERGY CONVERSION↗

Analysis Background & Noise in Stretched Wire Alignment Technique Measurements

The Stretched-Wire Alignment Technique (SWAT) is one method of magnet alignment for linear induction accelerators. The applications of SWAT have been implemented for aligning solenoid magnets on the Scorpius linear induction accelerator which will be sited at the Nevada National Security Site and the Flash X-Ray (FXR) linear induction accelerator at Lawrence Livermore National Laboratory’s Contained Firing Facility. This article describes both systematic (repeatable) and random sources of background and noise as well as practical ways to eliminate or reduce them to acceptable levels. Systematic sources include reflections from wire ends, rapid sag due to ohmic heating of the wire, magnetic materials, and shot rate. Random sources include air currents, vibration of nearby equipment, mechanical stability of test equipment, and the instruments used to measure the wire motion. Mitigations include curve fitting and adaptive noise signal cancellation, and mechanical damping. Finite Element Analysis (FEA) was used to identify and resolve a repeatable wire vibration frequency interfering with the signal resolution. Two stretched wire alignment technique set ups from Sandia National Labs and Lawrence Livermore National Lab have shown background noise sources and ways of mitigating them by either analysis methods or change of mechanical configuration. Conclusions that were drawn included the severe sensitivity of the deflection to even small external interferences of the SWAT wire such that it requires attention to detail in mechanical set up and analysis.

Linear Inductive Accelerator↗

Set Up and Test Results for a Vibrating Wire System for Quadrupole Fiducialization

Quadrupoles will be placed between the undulator segments in LCLS to keep the electron beam focused as it passes through. The quadrupoles will be assembled with their respective undulator segments prior to being placed into the tunnel. Beam alignment will be used to center the quadrupoles, along with the corresponding undulators, on the beam. If there is any displacement between the undulator and the quadrupole axes in the assemblies, the beam will deviate from the undulator axis. If it deviates by more than 80{micro}m in vertical or 140{micro}m in horizontal directions, the undulator will not perform as required by LCLS. This error is divided between three sources: undulator axis fiducialization, quadrupole magnetic axis fiducialization, and assembly of the two parts. In particular, it was calculated that the quadrupole needs to be fiducialized to within 25{micro}m in both vertical and horizontal directions. A previous study suggested using a vibrating wire system for finding the magnetic axis of a quadrupole. The study showed that the method has high sensitivity (up to 1{micro}m) and laid out guidelines for constructing it. There are 3 steps in fiducializing the quadrupole with the vibrating wire system. They are positioning the wire at the magnet center (step 1), finding the wire with position detectors (step 2), and finding the quadrupole tooling ball positions relative to the position detector tooling balls (step 3). The following break up of error was suggested for the fiducialization steps: 10{micro}m for step 1 (finding the center), 20{micro}m for step 2 (finding the wire), and 10{micro}m for step 3 (tooling ball measurements). The purpose of this study is to investigate whether the vibrating wire system meets the requirements for LCLS. In particular, if it can reliably fiducialize a quadrupole magnetic center to within 25{micro}m in both vertical and horizontal directions. The behavior of individual system components is compared to the expected performance. A vibrating wire system was constructed to fiducialize the quadrupoles between undulator segments in the LCLS. This note studies the ability of the system to fulfill the fiducialization requirements.

43 PARTICLE ACCELERATORS↗

Set Up and Test Results for a Vibrating Wire System for Quadrupole Fiducialization

Quadrupoles will be placed between the undulator segments in LCLS to keep the electron beam focused as it passes through. The quadrupoles will be assembled with their respective undulator segments prior to being placed into the tunnel. Beam alignment will be used to center the quadrupoles, along with the corresponding undulators, on the beam. If there is any displacement between the undulator and the quadrupole axes in the assemblies, the beam will deviate from the undulator axis. If it deviates by more than 80{micro}m in vertical or 140{micro}m in horizontal directions, the undulator will not perform as required by LCLS. This error is divided between three sources: undulator axis fiducialization, quadrupole magnetic axis fiducialization, and assembly of the two parts. In particular, it was calculated that the quadrupole needs to be fiducialized to within 25{micro}m in both vertical and horizontal directions. A previous study suggested using a vibrating wire system for finding the magnetic axis of a quadrupole. The study showed that the method has high sensitivity (up to 1{micro}m) and laid out guidelines for constructing it. There are 3 steps in fiducializing the quadrupole with the vibrating wire system. They are positioning the wire at the magnet center (step 1), finding the wire with position detectors (step 2), and finding the quadrupole tooling ball positions relative to the position detector tooling balls (step 3). The following break up of error was suggested for the fiducialization steps: 10{micro}m for step 1 (finding the center), 20{micro}m for step 2 (finding the wire), and 10{micro}m for step 3 (tooling ball measurements). The purpose of this study is to investigate whether the vibrating wire system meets the requirements for LCLS. In particular, if it can reliably fiducialize a quadrupole magnetic center to within 25{micro}m in both vertical and horizontal directions. The behavior of individual system components is compared to the expected performance. A vibrating wire system was constructed to fiducialize the quadrupoles between undulator segments in the LCLS. This note studies the ability of the system to fulfill the fiducialization requirements.

43 PARTICLE ACCELERATORS↗

Correlating Electronic Transport to Atomic Structures in Self-Assembled Quantum Wires

Quantum wires, as a smallest electronic conductor, are expected to be a fundamental component in all quantum architectures. The electronic conductance in quantum wires, however, is often dictated by structural instabilities and electron localization at the atomic scale. Here we report on the evolutions of electronic transport as a function of temperature and interwire coupling as the quantum wires of GdSi{sub 2} are self-assembled on Si(100) wire-by-wire. The correlation between structure, electronic properties, and electronic transport are examined by combining nanotransport measurements, scanning tunneling microscopy, and density functional theory calculations. A metal-insulator transition is revealed in isolated nanowires, while a robust metallic state is obtained in wire bundles at low temperature. The atomic defects lead to electron localizations in isolated nanowire, and interwire coupling stabilizes the structure and promotes the metallic states in wire bundles. This illustrates how the conductance nature of a one-dimensional system can be dramatically modified by the environmental change on the atomic scale.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

EVALUATION OF PRESSURE DROP CORRELATIONS FOR THE WIRE-WRAPPED ROD BUNDLES

The accurate prediction of pressure drop in the fuel rod bundle is of importance for the design and thermal-hydraulic analysis of nuclear reactor system. Due to very complex geometry of wire-wrapped fuel rod bundle geometry for the Sodium Fast Reactor (SFR), a simple method using hydraulic (equivalent) diameter is not sufficient to predict the pressure drop of rod bundle accurately. For several decades, many experimental works have been performed to develop an accurate correlation for wire-wrapped fuel bundle friction factor. In these works, the friction factor correlation of wire-wrapped fuel bundle has been developed as a function of Reynolds number of the flow and the design parameters such as fuel pin diameter, wire diameter, rod pitch, and wire lead length. The Cheng and Todreas correlations are well-known and used in many subchannel analysis code, such as CADET, TRIO-U, MATRA-LMW, SE2-ANL, etc. Novendstern model, Rehme model, Baxi and Dalle Donne model are also well-known and widely referred. Computational Fluid Dynamics is another typical approach to predict the pressure drop of wire-wrapped fuel rod bundle, but it requires the model validation because the accuracy of pressure drop prediction by the CFD simulation depends on what turbulence model is employed. The present work aims at evaluating the existing pressure drop correlations for the wire-wrapped fuel rod bundle and evaluating the pressure drop of 217-pin rod bundle by the CFD analysis.

99 GENERAL AND MISCELLANEOUS↗

Highly Densified Cu Wirings Fabricated from Air-Stable Cu Complex Ink with High Conductivity, Enhanced Oxidation Resistance, and Flexibility

The microstructure of printed Cu wirings fabricated from air-stable Cu complex inks is greatly modified by low-temperature curing followed by intense pulsed light densification enhancement treatment. The resulting almost full densification of printed Cu wirings enables them to possess a high electrical conductivity of 50% bulk Cu. The dense structure also largely prevents the permeation of oxygen and water into the inner side of the Cu wirings, thereby improving their oxidation resistance and maintaining a stable resistance (R/R0 < 1.5) even after 1000 h aging at 85 °C-85% RH. In addition, the dense and robust structure can improve the resistance to crack generation and propagation in Cu wirings during the bending, so as to improve their flexibility. The relative resistance of Cu wirings can be kept below 1.2 after 1000 bending cycles. All the results indicate that these highly densified Cu wirings fabricated from air-stable Cu complex inks can be used to replace the noble metallic Au and Ag wirings for practical application in flexible electronics.

Li, Wanli↗

Electronic Structure of HgBa{sub 2}CuO{sub 4+δ} with Self-organized Interstitial Oxygen Wires in the Hg Spacer Planes

While recent experiments have found that at optimum doping for the highest critical temperature in HgBa{sub 2}CuO{sub 4+y} (Hg1201) the oxygen interstitials (O-i) are not homogeneously distributed but form one-dimensional atomic wires, there are no available information of its electronic structure considering self-organized O-i atomic wires. Here we report the calculated electronic structure of HgBa{sub 2}CuO{sub 4+y} where oxygen interstitials form atomic wires along (1,0,0) crystal direction in the Hg layer. We find that at optimum doping for superconductivity the chemical potential is tuned near an electronic topological Lifshitz transition for the appearing of a second quasi 1D Fermi surface. A first large Fermi surface coexists with a second incipient quasi one-dimensional (1D) Fermi surface related with atomic wires of oxygen interstitials. Increasing oxygen doping the chemical potential is driven to the band edge of the second 1D-band giving a peak in the density-of-states. The new 1D electronic states are confined near the oxygen interstitial wires with a small spread only on nearby sites. Spin-polarized calculations show that the magnetic response is confined in the oxygen-poor domains free of oxygen interstitials wires and it is quite insensitive to the density of O-i wires.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗