Search NASA⌕ Search

SEARCH · Search NASA

Results for “x-ray mirror”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

The Einstein Observatory and future X-ray telescopes

A history of the events leading to the development and flight of the Einstein Observatory is given. The advantages of using grazing-incidence telescopes for solar and extrasolar X-ray astronomy is first discussed and followed by a description of the HEAO program. The Einstein Observatory marks a departure from the manner in which X-ray investigations are carried out, from individual experiments to the shared use of large facilities. The Observatory has achieved a sensitivity to point sources of 10 to the -14th erg/sq cm-sec in the 1-3 keV band, a flux 500 times smaller than previously detected and about 10 million times smaller than that of the first extrasolar source detected in 1962. The design philosophy of the Observatory entails three principles: (1) the unified scientific approach, (2) the establishment of spacecraft requirements at lowest acceptable levels that still allow operating flexibility, and (3) the idea of 'soft' rather than 'hard' failure. The mirror design, including the high resolution imager, the imaging proportional counter, and the solid-state and focal plane crystal spectrometers, is also given. An account of the struggle to gain acceptance by the scientific community and the funding agencies of the need for the Einstein Observatory mission is discussed. Finally, results of observations made by the Observatory are presented in detail, along with plans for future observation experiments.

Giacconi, R.↗

The ALEXIS data processing package: An IDL based system

The Array of Low Energy X-ray Imaging Sensors (ALEXIS) experiment consists of a mini-satellite containing six wide angle EUV/ultrasoft x-ray telescopes. Its purpose is to map out the sky in three narrow (approximately 5 percent) bandpasses around 66, 71, and 93 eV. The 66 and 71 eV bandpasses are centered on intense Fe emission lines which are characteristic of million degree plasmas such as the one thought to produce the soft x-ray background. The 93 eV bandpass is not near any strong emission lines and is more sensitive to continuum sources. The mission will be launched on the Pegasus Air Launched Vehicle in the second half of 1992 into a 400-nautical-mile, high inclination orbit and will be controlled entirely from a small ground station located at Los Alamos. The project is a collaborative effort between Los Alamos National Laboratory, Sandia National Laboratory, and the University of California-Berkeley Space Sciences Laboratory. The six telescopes are arranged in three pairs. As the satellite spins twice a minute they scan the entire anti-solar hemisphere. Each f/1 telescope consists of a spherical, multilayer-coated mirror with a curved, microchannel plate detector located at the prime focus. The multilayer coatings determine the bandpasses of the telescopes. The field of view of each telescope is 30 degrees with a spatial resolution of 0.5 degree, limited by spherical aberration. The data processing requirements for ALEXIS are large. Each event is one of the six telescopes is telemetered to the ground with its time of arrival and position on the detector. This information must be folded with the aspect solution for the satellite to reconstruct the direction on the sky from which the photon came. Because of the way the six telescopes scan the sky, the effective exposure calculation is also very computationally intensive. ALEXIS may generate up to 100 megabytes of raw data per day, which are converted into a gigabyte per day of processed data. While the processing job for ALEXIS is sizable, the programming staff is small. To maximize programming efficiency, and to make the best use of tools available in the public domain, we chose IDL as our software development platform. IDL was used from the start of instrument development through flight. We use IDL as a top-level executive for the processing tasks (replacing Unix shell scripts), as a device independent graphics engine, as a database manager, and as a final data manipulator. IDL routines spawn special purpose C programs to perform detailed telemetry deconvolution and other specialized functions. We discuss the use of IDL and C within the processing and archiving strategy for the ALEXIS data anlaysis system as implemented on a SPARCstation platform. We also show results from our End-to-End software simulation capability as processed by our analysis codes.

Bloch, J. J.↗

Optimal grazing incidence optics and its application to wide-field X-ray imaging

A class of high-resolution, efficient, and wide-field grazing incidence optics is discussed. Optical designs for searching efficiently for distant X-ray clusters are developed. It is shown that a rather general procedure exists for the design of an optical mission if well-defined scientific goals can be provided. Clusters of galaxies with an angular diameter of about 5 arcsec over a field of about 1 deg are resolved so that a comprehensive deep search is possible with a payload of 1/10 the linear dimensions of AXAF. By dropping the requirement for perfect on-axis imagery, searching within a suitably general class of telescope design, and optimizing a quantity directly related to the scientific requirement, it is shown that satisfactory designs do exist. The resulting telescope is shown to be no more difficult to fabricate than existing mirrors, and it can be nested.

Burrows, Christopher J.↗

Soft X-Ray Telescope (SXRT)

The soft X-ray telescope (SXRT) will provide direct images of the solar corona with spatial resolution of about 1 arcsecond. These images will show the global structure of the corona, the location and area of coronal holes, and the presence of even the smallest active regions and flares. The good spatial resolution will show the fine scale magnetic structure and changes in these phenomena. These observations are essential for monitoring, predicting, and understanding the solar magnetic cycle, coronal heating, solar flares, coronal mass ejections, and the solar wind. These observations complement those of the White Light Coronagraph and Ultra-Violet Coronal Spectrometer; the SXRT will detect active regions and coronal holes near the east limb, thereby giving a week or more of advanced warning for disturbed geomagnetic conditions at Earth. The instrument consists of a grazing incidence collecting mirror with a full disk film camera at the primary focus, and a secondary relay optic that feeds a CCD camera with a field of view about the size of an average active region.

Moore, R. L.↗

Soft X-ray telescope (SXRT)

The soft X-ray telescope (SXRT) will provide direct images of the solar corona with spatial resolution of about 1 arcsecond. These images will show the global structure of the corona, the location and area of coronal holes, and the presence of even the smallest active regions and flares. The good spatial resolution will show the fine scale magnetic structure and changes in these phenomena. These observations are essential for monitoring, predicting, and understanding the solar magnetic cycle, coronal heating, solar flares, coronal mass ejections, and the solar wind. These observations complement those of the White Light Coronagraph and Ultra-Violet Coronal Spectrometer; the SXRT will detect active regions and coronal holes near the east limb, thereby giving a week or more of advanced warning for disturbed geomagnetic conditions at Earth. The instrument consists of a grazing incidence collecting mirror with a full-disk film camera at the primary focus, and a secondary relay optic that feeds a CCD camera with a field of view about the size of an average active region.

Moore, R.↗

X-ray satellite (Rosat)

An overview of the current status of the ROSAT X-Ray satellite project is given. Areas discussed include an overview of problem areas, systems and mechanical subsystems, the electrical subsystem, power supply, data processing and transmission, the wide field camera, ground support equipment and the production scheduling. It is shown that the project is proceeding according to schedule, including the hardware production and costs. However, it is stated that estimated additional costs will exceed the plan. The previous schedule for production of the flight model will no longer be met. A modified milestone plan has been worked out with Dornier Systems. The current working schedule calls for a launch data of December 21, 1987; however, this does not take into account a 4-week buffer prior to transporting the flight model to the launch site. As of the date of this report, milestone M5 has been met. Previous problems with the gold vapor deposition on the flight model mirror due to contamination have been eliminated.

Source record↗

Vignetting characteristics of the S-056 X-ray telescope

A ray trace analysis of the vignetting characteristics of the S-056 X ray telescope is presented. The relative energy is calculated in the spot formed in the focal plane of the S-056 X ray telescope by an off axis point source at infinity for off axis angles of 0, 1, 2, ..., 35 arc minutes. At each off axis angle, the relative energies are evaluated using theoretical X ray reflectivity curves for wavelengths of 8.34 A, 17.57 A, and 27.39 A, and also using an experimental X ray reflectivity curve for 8.34 A. The effects of vignetting due purely to the geometry of the S-056 optical system are evaluated separately, as well as jointly with the effects of mirror reflectivity.

Foreman, J. W., Jr.↗

Proposal to National Aeronautics and Space Administration for continuation of a grazing incidence imaging telescope for X-ray astronomy using sounding rockets

The construction of a high resolution imaging telescope experiment payload suitable for launch on an Astrobee F sounding rocket was proposed. Also integration, launch, and subsequent data analysis effort were included. The payload utilizes major component subassemblies from the HEAO-B satellite program which were nonflight development units for that program. These were the X ray mirror and high resolution imager brassboard detector. The properties of the mirror and detector were discussed. The availability of these items for a sounding rocket experiment were explored with the HEAO-B project office.

Murray, B.↗

Cygnus X-3 observed at photon energies above 500 GeV

High-energy gamma rays from Cyg X-3 have been observed with the twin 11-m mirrors of NASA JPL's solar energy facility, using the atmospheric Cerenkov technique, resulting in data from about 100,000 air shower events with an approximate threshold energy of 500 GeV for the August 29 to September 6, 1981 period. A positive signal whose amplitude is 10.9 + or - 2.5% of the background cosmic ray rate appears near phase 0.6 of the 4.8-hour cycle, where phase 0.0 corresponds to minimum X-ray emission. This, together with previous Cerenkov detections, indicates that the high energy emission from Cyg X-3 is evolving on a time scale of a few years and suggests that the present form of the system has a recent origin.

Lamb, R. C.↗

Fast variations in high-energy X-rays from solar flares and their constraints on nonthermal models

The results of a quantitatve analysis of quantitative the temporal properties of over 7000 hard X-ray solar flares are presented. The data were obtained with the Hard X-ray Burst Spectrometer of the SMM satellite. The data reveal examples of hundreds of fast spikes with durations of less than 1 s. The spectra of a well-observed fast spike were compared with the predicted spectra of a detailed nonthermal electron beam model, in order to determine upper limits for electron beam parameters and path lengths. The theoretical spectra were found to be consistent with the observed spectra when the separation of between the accretion site and the thick target was greater than 10 to the 8th cm. It is shown that if the separation is much greater than 3 x 10 to the 9th cm, the electrons with high pitch angles (greater than 60 deg) are either not emitted or are mirrored before they reach the footpoints.

Kiplinger, A. L.↗

Soft X-ray/extreme ultraviolet images of the solar atmosphere with normal incidence multilayer optics

High-resolution images of the sun in the soft-X-ray/XUV range have been obtained with normal-incidence multilayer coated optics (MCOs) during a sounding-rocket flight on October 23, 1987 from White Sands. MCOs were used in two Cassegrain telescopes, as off-axis primary mirrors, and as tertiary mirrors operating with a Wolter-Schwarzschild (WS) grazing-incidence mirror. The inherent energy-selective property of MCOs allowed distinct groups of emission lines to be isolated in the solar corona and the transition region. Images were recorded at 173 and 256 A with the Cassegrain telescopes, at 256 A with a Herschelian telescope, and at 44, 173, and 256 A with the WS hybrid telescope. In addition, soft-X-ray images in the 8-18-A bandpass were obtained at the prime focus of the WS optics. The images show many features of the solar corona and transition region, including magnetically confined loops of hot solar plasma, coronal plumes, polar coronal holes, supergranulation, and features associated with overlying cool prominences.

Lindblom, Joakim F.↗

Normal-incidence soft X-ray telescopes

Photos obtained during 5 min of observation time from the flight of a 25-cm-diameter normal-incidence soft-X-ray (63.5 A) telescope on September 11, 1989, are analyzed, and the data are compared to the results expected from tests of the mirror surfaces. These tests cover a range of spatial periods from 25 cm to 1 A. The photos demonstrate a resolution close to the photon shot-noise limit and a reduction in the scattering of the multilayer mirror compared to a single surface for scattering angles above 1 arcmin, corrresponding to surface irregularities with spatial periods below 10 microns. These results are used to predict the possible performance of future telescopes. Sounding rocket observations might be able to reach a resolution around 0.1 arcsec.

Spiller, Eberhard↗

Advanced water window x-ray microscope design and analysis

The project was focused on the design and analysis of an advanced water window soft-x-ray microscope. The activities were accomplished by completing three tasks contained in the statement of work of this contract. The new results confirm that in order to achieve resolutions greater than three times the wavelength of the incident radiation, it will be necessary to use aspherical mirror surfaces and to use graded multilayer coatings on the secondary (to accommodate the large variations of the angle of incidence over the secondary when operating the microscope at numerical apertures of 0.35 or greater). The results are included in a manuscript which is enclosed in the Appendix.

Shealy, D. L.↗

Single liquid source plasma-enhanced metalorganic chemical vapor deposition of high-quality YBa2Cu3O(7-x) thin films

High quality YBa2Cu3O(7-x) films were grown in-situ on LaAlO3 (100) by a novel single liquid source plasma-enhanced metalorganic chemical vapor deposition process. The metalorganic complexes M(thd) (sub n), (thd = 2,2,6,6-tetramethyl-3,5-heptanedionate; M = Y, Ba, Cu) were dissolved in an organic solution and injected into a vaporizer immediately upstream of the reactor inlet. The single liquid source technique dramatically simplifies current CVD processing and can significantly improve the process reproducibility. X-ray diffraction measurements indicated that single phase, highly c-axis oriented YBa2Cu3O(7-x) was formed in-situ at substrate temperature 680 C. The as-deposited films exhibited a mirror-like surface, had transition temperature T(sub cO) approximately equal to 89 K, Delta T(sub c) less than 1 K, and Jc (77 K) = 10(exp 6) A/sq cm.

Zhang, Jiming↗

The X-ray reflectivity of the AXAF VETA-I optics

The study measures the X-ray reflectivity of the AXAF VETA-I optic and compares it with theoretical predictions. Measurements made at energies of 0.28, 0.9, 1.5, 2.1, and 2.3 keV are compared with predictions based on ray trace calculations. Results on the variation of the reflectivity with energy as well as the absolute value of the reflectivity are presented. A synchrotron reflectivity measurement with a high-energy resolution over the range 0.26 to 1.8 keV on a flat Zerodur sample is also reported. Evidence is found for contamination of the flat by a thin layer of carbon on the surface, and the possibility of alteration of the surface composition of the VETA-I mirror, perhaps by the polishing technique. The overall agreement between the measured and calculated effective area of VETA-I is between 2.6 and 10 percent. Measurements at individual energies deviate from the best-fitting calculation to 0.3 to 0.8 percent, averaging 0.6 percent at energies below the high energy cutoff of the mirror reflectivity, and are as high as 20.7 percent at the cutoff.

Kellogg, E.↗

Organometallic chemical vapor deposition and characterization of ZnGe(1-x)Si(x)P2-Ge alloys on GaP substrates

In this paper, we report the epitaxial growth of ZnGe(1-x)Si(x)P2-Ge alloys on GaP substrates by open tube OMCVD. The chemical composition of the alloys characterized by energy dispersive X-ray spectroscopy shows that alloys with x up to 0.13 can be deposited on (001) GaP. Epitaxial growth with mirror smooth surface morphology has been achieved for x less than or equals to 0.05. Selected area electron diffraction pattern of the alloy shows that the epitaxial layer crystallizes in the chalcopyrite structure with relatively weak superlattice reflections indicating certain degree of randomness in the cation sublattice. Hall measurements show that the alloys are p-type, like the unalloyed films; the carrier concentration, however, dropped about 10 times from 2 x 10 exp 18 to 2 x 10 exp 17/cu cm. Absorption measurements indicate that the band tailing in the absorption spectra of the alloy has been shifted about 0.04 eV towards shorter wavelength as compared to the unalloyed material.

Xing, G. C.↗

Organometallic chemical vapor deposition and characterization of ZnGe(1-x)Si(x)P2-Ge alloys on GaP substrates

The epitaxial growth of ZnGe(1-x)Si(x)P2-Ge alloys on GaP substrates by open tube organometallic chemical vapor deposition (OMCVD) is reported. The chemical composition of the alloys characterized by energy dispersive X-ray spectroscopy shows that alloys with x up to 0.13 can be deposited on (001) GaP. Epitaxial growth with mirror smooth surface morphology was achieved for x less than or equal to 0.05. Transmission electron microscopy (TEM) micrographs of these alloys show specular epitaxy and the absence of microstructural defects indicating a defect density of less than 10(exp 7) cm(sup -2). Selected area electron diffraction pattern of the alloy shows that the epitaxial layer crystallizes in the chalcopyrite structure with relatively weak superlattice reflections indicating certain degree of randomness in the cation sublattice. Hall measurements show that the alloys are p-type, like the unalloyed films; the carrier concentration, however, dropped about 10 times from 2 x 10(exp 18) to 2 x 10(exp 17) cm(sup -3). Absorption measurements indicate that the band tailing in the absorption spectra of the alloy was shifted about 0.04 eV towards shorter wavelength as compared to the unalloyed material. Diodes fabricated from the n(+)-GaP/p-ZnSiP2-ZnGeP2-Ge heterostructure at x = 0.05 have a reverse break-down voltage of -10.8 V and a reverse saturation current density of approximately 6 x 10(exp -8) A/sq cm.

Xing, G. C.↗