Search NASA⌕ Search

SEARCH · Search NASA

Results for “AIR FLOW - AIRFOILS - OSCILLATING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Wickability-optimized textured liquid-desiccant air dehumidifiers for independent moisture management in energy-efficient buildings

Liquid-desiccant-based air conditioning systems are envisioned to enable independent humidity management, thereby improving the energy efficiency of future buildings. Existing liquid-desiccant-based air conditioning concepts, however, suffer from a poor liquid flow distribution deteriorating moisture removal rate. They are consequently flooded with the liquid-desiccant solution, which significantly degrades the energy efficiency of the dehumidification process. Here, in this work, the capillary forces and wickability effect of textured air dehumidifier surfaces are altered to minimize the liquid-desiccant flow rate of the fully wetted state, thereby transforming the physics of interfacial desiccant flow distribution. Consequently, the wickability-optimized air dehumidifier surface maximizes both moisture removal rate and dehumidification energy efficiency. It was interestingly found that the length scale of a textured air dehumidifier surface concept is optimized at an intermediate pattern density. Dry solid-air menisci appear at length scales exceeding the optimum pattern distance while the effective liquid–air interfacial area is reduced at smaller length scales, both of which degrade the moisture removal rate. At the optimum pattern density, the effective liquid–air interfacial area increases with the solution flow rate, thereby increasing the dehumidification rate. At a water vapor pressure potential of 3 kPa and a solution flow rate of 2.8 g/s, experimental results indicated a moisture removal rate of 0.16 g/m2-s for a textured surface concept with a capillary length scale of 3 mm, a 28% improvement compared with that of smooth-plate dehumidifier surfaces. A high moisture removal rate of the textured surface at a low desiccant flow rate led to a high thermal efficiency of 0.75 at a water vapor pressure potential of 5.6 kPa and a LiBr flow rate of 2.8 g/s. The insights gained from the present study accelerate the development of advanced textured surface concepts for next-generation liquid-desiccant-based air dehumidification systems offering independent humidity management for future energy-efficient buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A nudged hybrid analysis and modeling approach for realtime wake-vortex transport and decay prediction

Here, we put forth a long short-term memory (LSTM) nudging framework for the enhancement of reduced order models (ROMs) of fluid flows utilizing noisy measurements for air traffic improvements. Toward emerging applications of digital twins in aviation, the proposed approach allows for constructing a realtime predictive tool for wake-vortex transport and decay systems. We build on the fact that in realistic application, there are uncertainties in initial and boundary conditions, model parameters, as well as measurements. Moreover, conventional nonlinear ROMs based on Galerkin projection (GROMs) suffer from imperfection and solution instabilities, especially for advection-dominated flows with slow decay in the Kolmogorov n-width. In the presented LSTM nudging (LSTM-N) approach, we fuse forecasts from a combination of imperfect GROM and uncertain state estimates, with sparse Eulerian sensor measurements to provide more reliable predictions in a dynamical data assimilation framework. We illustrate our concept by solving the two-dimensional vorticity transport equation. We investigate the effects of measurements noise and state estimate uncertainty on the performance of the LSTM-N behavior. We also demonstrate that it can sufficiently handle different levels of temporal and spatial measurement sparsity, and offer a huge potential in developing next-generation digital twin technologies for aerospace applications.

42 ENGINEERING↗

Adsorption-based membranes for air separation using transition metal oxides

In this work, we use computational modeling to examine the viability of adsorption-based pore-flow membranes for separating gases when a purely size-based separation strategy is ineffective. Using molecular dynamics simulations of O 2 and N 2 , we model permeation through a nanoporous graphene membrane. Permeation is assumed to follow a five-step adsorption-based pathway, with desorption being the rate-limiting step. Using this model, we observe increased selectivity between O 2 and N 2 , resulting from increased adsorption energy differences. We explore the limits of this strategy, providing an initial set of constraints that need to be satisfied to allow for selectivity. Finally, we provide a preliminary exploration of some transition metal oxides that appear to satisfy those conditions. Using density functional theory calculations, we confirm that these oxides possess adsorption energies needed to operate as adsorption-based pore-flow membranes. These adsorption energies provide a suitable motivation to examine adsorption-based pore-flow membranes as a viable option for air separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling ammonia-fueled co-flow dual-channel protonic-ceramic fuel cells

This paper reports the model development for a dual-channel protonic-ceramic fuel cell (PCFC) operating on ammonia fuel. The model considers the coupled interactions of several physical and chemical processes, including three-dimensional heat conduction within the bipolar plates and the membrane-electrode assembly (MEA), one-dimensional flow within the fuel and air channels, detailed heterogeneous catalytic reactions within the porous composite anode structure, Butler–Volmer representation of the charge-transfer chemistry, and Nernst–Planck transport of three charged defects (protons, oxygen vacancies, and small polarons) within the dense electrolyte membrane. The membrane-electrode assembly is composed of a Ni-BCZYYb (BaCe 0.7 Zr 0.1 Y 0.1 Yb 0.1 O 3-δ ) anode, a BCZYYb electrolyte membrane, and a BCFZY (BaCo 0.4 Fe 0.4 Zr 0.1 Y 0.1 O 3-δ ) cathode. Chemical and physical parameters for the MEA model are established using previously published button-cell data. One aspect of the study is to investigate the partial ammonia decomposition upstream of the fuel cell. Such fuel cracking increases the H 2 content of the fuel entering the PCFC, which may have benefits. However, endothermic ammonia pyrolysis within the composite anode structure assists with thermal control of the cell. The dual-channel model can be considered as the unit cell of a full fuel-cell stack.

25 ENERGY STORAGE↗

Measurements of He-Ar, He-N 2 , and He-air thermal creep slip and accommodation coefficients at high temperatures

Understanding gas flows in capillaries has many applications in modeling the transport of gases in nano-structured, porous, or fractured media. A network of capillaries can often approximate these media, and also information on gas-surface interactions obtained from capillary experiments can be used for modeling flows in these media. Experimental data on flows of different mixtures of He-Ar, He-N 2 , and He-air in the slip regime and in stainless steel capillaries at high temperatures were obtained by using a two-bulb apparatus. An accurate expression for the thermal creep slip coefficients with the Lennard-Jones potential parameters and diffuse-specular reflection gas-surface interaction conditions were then used to obtain the accommodation coefficients for the different gases. The experimental data are best described with values of accommodation coefficients in the range of 0.1–0.3 for He and 0.5–1.0 for Ar, N 2 , and air. Further, the use of values in this range is suggested for modeling gaseous flows in capillaries and nano-structured, porous, or fractured media if other direct measured values for a particular medium are unavailable.

42 ENGINEERING↗

Integration and validation of some modules for modelling of high-speed chemically reactive flows in two-phase gas-droplet mixtures

Three modules are integrated into the built-in OpenFOAM rhoCentralFoam solver towards accurate and efficient modelling of high-speed chemically reactive flows in two-phase gas-droplet mixtures within the OpenFOAM 10.0 framework. The first module is the mixture-averaged diffusion model. The second module is the built-in OpenFOAM Lagrangian solver coupled with optimised droplet drag coefficient and convective heat transfer coefficient sub-models. The last module is a sparse stiff chemistry solver based on dynamic adaptive hybrid integration (AHI-S). The optimised droplet sub-models are first verified in correct implementation for subsequent simulations in this work. Further, they show good accuracy against experimental and analytical data in the modelling of ammonia droplet acceleration and cooling in the flowing and/or low-temperature air. The accuracy and efficiency gains related to the mixture-averaged diffusion model and the AHI-S chemistry solver are examined by simulating 1-D detonation propagation in ammonia droplet-free/laden ammoniaoxygen mixtures. Numerical results of detonation propagation speed, gaseous temperature, density, and species distributions around the induction zone show good agreement with experimental data and analytical solutions. Compared to the built-in OpenFOAM diffusion model, the mixture-averaged diffusion model provides different numerical predictions of pulsating instabilities in detonation propagation. It shows better accuracy in depicting the detonation structure within the droplet-free section attributed to improved multi-component diffusion modelling. Compared to the built-in OpenFOAM solver EulerImplicit (backward Euler), the AHI-S chemistry solver reduces the computational cost by around 50%. It achieves satisfactory accuracy in calculating detonation propagation speed within the droplet-free section with the optimal efficiency when the safety factor, β, equals 0.5.

42 ENGINEERING↗

Sensitivity Analysis of an Electrospray Dehumidification System

Electrically enhanced condensation achieved by an electrospray system can enhance dehumidification in HVAC applications if successfully scaled up. The first step towards scale-up is identifying critical design and operating parameters that significantly impact dehumidification for the electrospray system. Sensitivity analysis is one approach for identifying critical parameters. This paper presents a methodology that can efficiently perform quantitative sensitivity analysis on a computationally expensive high fidelity simulation model, which is a computational fluid dynamics (CFD) model of the electrospray system. The methodology employs surrogate modeling and Sobol sensitivity analysis. We estimate the main and total effect Sobol sensitivity indices of four operating parameters of the electrospray system. The results reveal that the most important parameter is the size of the sprayed droplets, followed by the volumetric flow rate of the bulk air and injected water in the system. The water injection velocity of the spray was found to have little to no impact on dehumidification.

Young, David↗

Selective Electrocatalysis Imparted by Metal-Insulator Transition for Durability Enhancement of Automotive Fuel Cells.

Repetitive start-up and shut-down events in polymer electrolyte membrane fuel cells for automotive applications lead to serious corrosion of the cathode due to an instantaneous potential jump that results from unintended air leakage into the anodic flow field followed by a parasitic oxygen reduction reaction (ORR) on the anode. Here we report a solution to the cathode corrosion issue during the start-up/shut-down events whereby intelligent catalyst design is used to selectively promote the hydrogen oxidation reaction (HOR) while concomitantly suppressing the ORR on the anode. Platinum thin layers supported on hydrogen tungsten bronze (Pt/HxWO3) suppressed the ORR by converting themselves into an insulator following exposure to oxygen, while selectively promoting the HOR by regaining metallic conductivity following subsequent exposure to hydrogen. The HOR-selective electrocatalysis imparted by a metal-insulator transition in Pt/HxWO3 demonstrated a remarkably enhanced durability of membrane electrode assemblies compared to those with commercial Pt/C catalysts.

Jung, Sang-Mun↗

An Experimental Comparison of Cyclic Variations in Diesel–Natural Gas and POMDME–Natural Gas Dual Fuel Combustion

Abstract Cyclic variations in internal combustion engines are caused by various factors, including combustion mixture stratification, in-cylinder flows, local fluctuations in air-fuel ratio, etc. Cyclic variations have a profound impact on engine performance and emissions. In this study, cyclic variations in dual fuel combustion are analyzed, comparing diesel–natural gas (NG) and polyoxymethylene dimethyl ether (POMDME)-NG dual fuel combustion. Cyclic variability was initially quantified using the coefficient of variation of gross indicated mean effective pressure (IMEPg) computed from experimental cylinder pressure data. The cases analyzed in this study had a coefficient of variation (COV) of IMEPg greater than or around 5%, which was the lower limit of onset of instability for this engine. Experiments were performed at two fixed start of injection (SOI) of high-cetane fuel: 310 CAD and 350 CAD. For all experiments, a constant load of 5 bar IMEPg was maintained, and the intake boost pressure and rail pressure were fixed at 1.5 bar and 500 bar, respectively. For each case, 1000 cycles of cylinder pressure data were recorded, filtered, and processed using an in-house heat release analysis code for each cycle. A comparison between individual cycles and the “ensemble averaged cycle” was made for both diesel–NG and POMDME–NG combustion. For the early SOI of 310 CAD, the peak cylinder pressure fluctuations of individual cycle were found to be ± 15 bar for both fuel combinations, compared to the ensemble averaged cycle, and < 1/10th of the cycles had an IMEPg lower than 0.05 bar of the ensemble averaged cycle. However, the peak pressure fluctuations were found to be lower for POMDME–NG (±3 bar) than diesel–NG dual fuel combustion at 350 CAD SOI, indicating lower cyclic variations. The higher reactivity of POMDME helped reduce fluctuations in combustion phasing at the retarded SOI. The presence of cycles of deterioration and cycles of recovery were also observed with diesel–NG combustion for 310 CAD SOI, and the scatter in the IMEPg return map was similar for both fuel combinations. The IMEPg return map for POMDME–NG combustion was less scattered at the 350 CAD SOI.

Engineering↗

C-FOG: Life of Coastal Fog

C-FOG is a comprehensive bi-national project dealing with the formation, persistence, and dissipation (life cycle) of fog in coastal areas (coastal fog) controlled by land, marine, and atmospheric processes. Given its inherent complexity, coastal-fog literature has mainly focused on case studies, and there is a continuing need for research that integrates across processes (e.g., air–sea–land interactions, environmental flow, aerosol transport, and chemistry), dynamics (two-phase flow and turbulence), microphysics (nucleation, droplet characterization), and thermodynamics (heat transfer and phase changes) through field observations and modeling. Central to C-FOG was a field campaign in eastern Canada from 1 September to 8 October 2018, covering four land sites in Newfoundland and Nova Scotia and an adjacent coastal strip transected by the Research Vessel Hugh R. Sharp . An array of in situ, path-integrating, and remote sensing instruments gathered data across a swath of space–time scales relevant to fog life cycle. Satellite and reanalysis products, routine meteorological observations, numerical weather prediction model (WRF and COAMPS) outputs, large-eddy simulations, and phenomenological modeling underpin the interpretation of field observations in a multiscale and multiplatform framework that helps identify and remedy numerical model deficiencies. An overview of the C-FOG field campaign and some preliminary analysis/findings are presented in this paper.

58 GEOSCIENCES↗

Hestia-SWIFL: hourly anthropogenic fossil fuel CO2 and heat on the 2km WRF grid, version 1.1

The Hestia-SWIFL version 1.1 anthropogenic heat (AH) and fossil fuel CO2 (FFCO2) emissions data product represent emissions due to the combustion of fossil fuel and cement production within the state of Arizona from 2019 to 2022. This product was developed as part of the Southwest Urban Corridor Integrated Field Laboratory (SW-IFL) project, which aims to provide new knowledge and tools that address extreme heat, air quality, climate change and related urban environmental issues by integrating high-resolution observations, modeling, and civic engagement. The emissions are generated using a bottom-up/engineering approach and are tied to results generated by the Vulcan Project version 4, an effort to quantify space/time-resolved FFCO2 & AH emissions for the entire United States landscape. A large number of data sources are combined to best estimate the emissions at fine scales such as air quality emissions data, traffic flow data, building information, sociodemographic information, and fuel statistics. The AH product provides emissions for two emissions sources (transportation and point source emissions) in units of Watts per hour per square meter (W/m2) per year (annual files) or per hour (hourly files). The FFCO2 product provides emissions from nine individual emission sectors as well as the total, and in units of tons of carbon (tC) per grid cell per year or per hour. The output made available here places the native spatial resolution of the Hestia FFCO2 & AH emissions data product (points, lines, and polygons) into a regularized 2km x 2km grid at hourly and annual temporal resolutions, and stored in netCDF files. The exact spatial extent is defined by the ASU Weather Research Forecast (WRF) simulation grid. All data are processed using R/Python pm high-performance computing system. 2-27-2026 updates: Bugs in airport hourly profile (both AH and FFCO2) and building spatial patterns (FFCO2 only) were fixed. Hourly emissions are reprocessed for all years to reflect those changes.

54 ENVIRONMENTAL SCIENCES↗

Nuclear Safety [Vol. 29, No. 1, January-March 1988]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. THE CHERNOBYL ACCIDENT: 1 Core History and Nuclide Inventory of the Chernobyl Core at the Time of Accident by Gerald Kirchner and Cornelius C. Noack; GENERAL SAFETY CONSIDERATIONS: 6 Nonprescriptive Nuclear Safety Regulation: The Example of Loss of Offsite Power by M. W. Golay, V. P. Manno, and C. Vlahoplus, Jr., 20 Nuclear Power Safety Goals in Light of the Chernobyl Accident by C. Whipple and C. Starr; ACCIDENT ANALYSIS: 29 Containment Loads from Severe Accidents—U.S. Program by W. Kerr and M. K. Dey; PLANT SAFETY FEATURES: 36 Safety Characteristics of Modern High-Temperature Reactors: Focus on German Designs by W. Kröger, H. Nickel, and R. Schulten; ENVIRONMENTAL EFFECTS: 49 Radiation Hormesis and Nuclear Safety by C. C. Congdon; OPERATING EXPERIENCES: 58 Evaluation of Nonradiological Water Chemistry at Power Reactors by Harvey Zibulsky, James J. Kottan, Walter J. Pasciak, Mary Ann Castrogivanni, and Sujit Banerjee, 64 Reactor Shutdown Experience Compiled by J. W. Cletcher, 67 Operating U.S. Power Reactors Compiled by E. G. Silver; RECENT DEVELOPMENTS: 85 General Administrative Activities Compiled by E. G. Silver, 94 Reports, Standards, and Safety Guides by D. S. Queener, 100 Status of Power-Reactor Projects Undergoing Licensing Review Compiled by E. G. Silver, 103 Proposed Rule Changes as of Sept. 30, 1987; ANNOUNCEMENTS: 5 Northwestern University Short Course on Radiation Safety, 28 International Approach to Nuclear Safety (After Three-Mile Island and Chernobyl), 57 RPI Short Course on Modern Developments in Boiling Heat Transfer and Two-Phase Flow, 107 20th DOE/NRC Nuclear Air Cleaning Conference, 110 Third International Topical Meeting on Nuclear Power Plant Thermal Hydraulics and Operations, 108 The Authors, 111 Indexes to Nuclear Safety, Volume 28.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear Safety [Vol. 29, No. 1, January-March 1988]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. THE CHERNOBYL ACCIDENT: 1 Core History and Nuclide Inventory of the Chernobyl Core at the Time of Accident by Gerald Kirchner and Cornelius C. Noack; GENERAL SAFETY CONSIDERATIONS: 6 Nonprescriptive Nuclear Safety Regulation: The Example of Loss of Offsite Power by M. W. Golay, V. P. Manno, and C. Vlahoplus, Jr., 20 Nuclear Power Safety Goals in Light of the Chernobyl Accident by C. Whipple and C. Starr; ACCIDENT ANALYSIS: 29 Containment Loads from Severe Accidents—U.S. Program by W. Kerr and M. K. Dey; PLANT SAFETY FEATURES: 36 Safety Characteristics of Modern High-Temperature Reactors: Focus on German Designs by W. Kröger, H. Nickel, and R. Schulten; ENVIRONMENTAL EFFECTS: 49 Radiation Hormesis and Nuclear Safety by C. C. Congdon; OPERATING EXPERIENCES: 58 Evaluation of Nonradiological Water Chemistry at Power Reactors by Harvey Zibulsky, James J. Kottan, Walter J. Pasciak, Mary Ann Castrogivanni, and Sujit Banerjee, 64 Reactor Shutdown Experience Compiled by J. W. Cletcher, 67 Operating U.S. Power Reactors Compiled by E. G. Silver; RECENT DEVELOPMENTS: 85 General Administrative Activities Compiled by E. G. Silver, 94 Reports, Standards, and Safety Guides by D. S. Queener, 100 Status of Power-Reactor Projects Undergoing Licensing Review Compiled by E. G. Silver, 103 Proposed Rule Changes as of Sept. 30, 1987; ANNOUNCEMENTS: 5 Northwestern University Short Course on Radiation Safety, 28 International Approach to Nuclear Safety (After Three-Mile Island and Chernobyl), 57 RPI Short Course on Modern Developments in Boiling Heat Transfer and Two-Phase Flow, 107 20th DOE/NRC Nuclear Air Cleaning Conference, 110 Third International Topical Meeting on Nuclear Power Plant Thermal Hydraulics and Operations, 108 The Authors, 111 Indexes to Nuclear Safety, Volume 28.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Operation and performance of VRF systems: Mining a large-scale dataset

The energy consumption of air-conditioning systems has gained increasing attention as it contributes significantly to the global building energy use. The variable refrigerant flow (VRF) system is a common air-conditioning system applied widely in residential and office buildings in China. Understanding the actual operation and performance of VRF systems is fundamental for the energy-efficient design and operation of VRF systems. Previous research on VRF system operation used either limited field data covering certain building types and climate zones or used a questionnaire to obtain a larger dataset. However, they did not capture the wide applications of VRF systems quantitatively across all building types, climate zones, and operating conditions. To fill this gap, statistical and clustering analysis was conducted on the newly proposed key performance indicators of approximately 287,000 VRF systems for residential and commercial buildings in all five climate zones in China. In this work, the main findings are: (1) VRF systems are mainly used for cooling in all climate zones in China; (2) among all building types, the duration of use is lowest in residential buildings and highest in hotels and medical buildings; (3) the distribution of the ideal VRF cooling coefficient of performance (COP) is similar across all climate zones and building types; whereas the COPs of ideal VRF heating in the Severe Cold region and Cold regions are lower than those in other climate zones; and (4) partial load operations for VRF systems are common in residential buildings and office buildings due to the part-time-part-space operation mode. These findings can inform the actual application of VRF systems in China, supporting the design, operation, industry standard development, and performance optimization of VRF systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cloud microphysical response to entrainment and mixing is locally inhomogeneous and globally homogeneous: Evidence from the lab

Entrainment of dry air into clouds strongly influences cloud optical and precipitation properties and the response of clouds to aerosol perturbations. The response of cloud droplet size distributions to entrainment–mixing is examined in the Pi convection-cloud chamber that creates a turbulent, steady-state cloud. The experiments are conducted by injecting dry air with temperature (T e ) and flow rate (Q e ) through a flange in the top boundary, into the otherwise well-mixed cloud, to mimic the entrainment–mixing process. Due to the large-scale circulation, the downwind region is directly affected by entrained dry air, whereas the upwind region is representative of the background conditions. Droplet concentration (Cn) and liquid water content (L) decrease in the downwind region, but the difference in the mean diameter of droplets (D m ) is small. The shape of cloud droplet size distributions relative to the injection point is unchanged, to within statistical uncertainty, resulting in a signature of inhomogeneous mixing, as expected for droplet evaporation times small compared to mixing time scales. As T e and Q e of entrained air increase, however, Cn, L, and D m of the whole cloud system decrease, resulting in a signature of homogeneous mixing. The apparent contradiction is understood as the cloud microphysical responses to entrainment and mixing differing on local and global scales: locally inhomogeneous and globally homogeneous. This implies that global versus local sampling of clouds can lead to seemingly contradictory results for mixing, which informs the long-standing debate about the microphysical response to entrainment and the parameterization of this process for coarse-resolution models.

54 ENVIRONMENTAL SCIENCES↗

Effect of Evaporation on Vapor Space Flammability in DWPF Process Vessels - 20278

The Savannah River Site (SRS) Defense Waste Processing Facility (DWPF) processes liquid high-level waste (HLW) and encapsulates it in glass within stainless-steel containers suitable for safe, long-term storage and disposal. Radiolytic and chemical decomposition of the liquid waste generates hydrogen and other flammable gases creating a hazard. The rate of flammable gas generation increases by an order of magnitude as temperature increases from sub-boiling to boiling. DWPF controls this hazard in process tanks by ensuring a minimum purge flow through each tank's head space. The minimum purge flow rate is established assuming dry air and neglecting evaporation. However, this study determined that steam from boiling in a representative process tank is sufficient to dilute flammable gases and, thereby, preclude flammability. For sub-boiling, water vapor is an insufficient diluent considering hydrogen's lower flammable limit (LFL) in air. However, the upper and lower flammable limits approach each other in a hydrogen-air-water-vapor environment as the water vapor concentration increases. This effect may preclude flammable conditions if water vapor concentration is about 60 volume percent or higher. A saturated, constant-pressure air-water system would achieve 60 volume percent water vapor at 86 deg. C. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Studies of Alternative Ventilation Configurations to Mitigate Airborne Exposure Risks in Office Spaces

The objective of this study was to evaluate the impact of alternative ventilation configurations on airflow patterns and potential exposure risks in office spaces. Two existing conference rooms at Sandia NM were modeled using Computational Fluid Dynamics (CFD) simulations to characterize airflow patterns and potential airborne exposure risks in well-mixed and once-through (through-flow) ventilation conditions. Multiple scenarios were studied to evaluate the impact of occupancy, Plexiglass barriers, and a modified-return airflow configuration. Experimental and visualization tests were also conducted to validate the well-mixed and through-flow models and findings. The simulations demonstrated that the modified-return airflow configuration that promoted through-flow conditions reduced pathogen concentrations within the space compared to the well-mixed airflow configuration; occupancy reduction only reduced the number of exposed individuals, and Plexiglass barriers had almost no effect. The experimentally measured air speeds at nine anemometer locations generally matched the simulated airflow velocities, and a fog-purge visualization test was also consistent with simulated results of plume movement and dissipation. The visualization tests demonstrated improvements in air change rate with the modified return, which promoted through-flow conditions, versus the original well-mixed ventilation configuration. The results of this study demonstrate that minor modifications to a space that promote through-flow conditions can improve air quality and reduce pathogen concentrations. Additional airflow modeling and testing of alternative occupied space configurations are recommended to further inform room designs that mitigate airborne exposure risks for occupants.

42 ENGINEERING↗

Glovebox CFD Analysis: Low-Flow, Laminar CFD Analysis of Glovebox Ventilation and Humidity Transport in Ansys Fluent 2025 R1

There are gloveboxes that frequently exceed the 30% relative humidity level required for operations. These exceedances result in alternative operations needing to be utilized. This report documents a computational fluid dynamics (CFD) analysis performed to characterize airflow and humidity transport within a representative glovebox under nominal, low-flow conditions. The analysis focuses on establishing the flow regime, identifying transport-limited regions, and evaluating the implications of laminar flow on humidity removal. A single-phase, laminar flow model with a species transport model was used to represent air and water vapor mixing. Results demonstrate that, at the nominal flow rates, airflow is laminar with weak mixing, which will result in long residence times, tens of minutes long or more, in low-velocity regions. These conclusions suggests that humidity reduction is transport-limited. This analysis provides qualitative insight into airflow structure and humidity transport trends. In addition to characterization of glovebox airflow and humidity transport, results are intended to inform experimental validation and future transient modeling efforts.

42 ENGINEERING↗